Public Administrative Department Government Departments Closing in 17 days TDR #58032043

Tender For Execution Of Work Under Providing Interpretation Center, M.S. Porta Cabin And Other Development Works At Ancient Mound Agroha, Hisar, Haryana

Issued by Government Departments · Hisar, Haryana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Nov 2026
17 days left
EMD
1.22 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Execution Of Work Under Providing Interpretation Center, M.S. Porta Cabin And Other Development Works At Ancient Mound Agroha, Hisar, Haryana

BOQ

Name of Work:- EXECUTION OF WORK UNDER PROVIDING INTERPRETATION CENTER, M.S. PORTA CABIN AND OTHER DEVELOPMENT WORKS AT ANCIENT MOUND AGROHA, HISAR, HARYANA
Sl. No. Item Description
1Description and specification of items of work to be executed (complete work)
2Provision for earth work in excavation by manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
4Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
5Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
6Provision for providing cement plaster in ratio of 1:4 (1 cement: 4 coarse sand)
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
8Provision for providing M.S. material for construction of interpretation centre 8 nos.of M.S. column of size 150*150*5 mm , 8nos of M.S.base plate 350*350*16mm,64 nos M20 M.S. anchor bolt length 550 mm, 16 stiffner plate 10 mm,4 no. of truss (truss chord size 100*100*3 and bracing 60*60*3),9 purlins of size 80*80*3 and other as per design
9Providing and applying of painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on work over an under coat of suitable shade with ordinary paint of approved brand and manufacture with cleaning of rust and primer complete.
10Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer -in-charge including proper locking system complete. Powder coated aluminium (minimum thickness of powder coating 50 micron) complete in all respects.
11Providing and fixing 4 mm thick ACP sheet in aluminium frame for doors, windows and clerestory windows complete as per the architectural drawings.
12Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows complete as per the architectural drawings and the directions of engineer-in-charge With frost glass panes of 5 mm thickness.
13Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar
14Providing and fixing PUF [Polyurethane Foam) panel of core thickness 50mm having density 40 kg/cum and Thermal Conductivity at LOoC [Mean Temperature) 0.023 W/mk in roof complete fitting with all accessories as per the direction of Engineer-in-charge.
15Providing and fixing of Everest vertical fibre cement boards of thickness 75mm having density not less than 700-800 kg/cum along with GI channels and all accessories in walls of interpretation centre complete fixing as per the direction of Engineer-in-charge.
16Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer- in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
17Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.
18Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
19Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (two or more coats)
20Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (PVC insulated copper single core cable 1.5 sqmm for circuit/submain wiring (RR/ havells/finolex)
21Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (PVC insulated copper single core cable 1 sqmm for circuit/submain wiring (RR/havells/finolex).
22Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (PVC insulated copper single core cable 4 sqmm for circuit/submain wiring (RR/havells/finolex).
23Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (conduit pipe/casing patti 25 mm.
24Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Band)
25Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Junction box )
26Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Clip 25mm)
27Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Box board (8”x6”)
28Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Box board(8”x3”))
29Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Modular Sheet )
30Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Modular switch)
31Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Socket )
32Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Fan regulator)
33Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Round sheet)
34Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Show light in false ceiling 36 watt(600*600mm))
35Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (MCB box)
36Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (MCB 16 amp)
37Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (63 amp. DP isolator)
38Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Tape )
39Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Nut 1.5inch)
40Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Nut 2 inch)
41Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Brass screw 1.5inch)
42Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Brass screw 2.0 inch)
43Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Steel screw)
44Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Power switch)
45Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Power socket)
46Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Exaust fan 230mm (bajaj/havells/crompton))
47Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. {Ceiling fan 1200mm of reputed brand (orient/havells/crompton etc. reputed brand)}
48Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Tube light )
49Providing and fixing of following electrical fittings, drawing of electrical wires and cables in PVC conduits, switch/sockets, LED lights etc. including connections, testing etc. (Labour charges for fixing all electric fitting )
50Supply and installation of 3 star Inverter spilit Air Conditioner of Make-Bluestar, Voltas, Diakin etc. (reputed brand) alongwith supply of outdoor stand with vibration isolation pad and Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units. 1.5 TR - HI-WALL TYPE + Cordless Remote and stabilizer along with fitting of Mcb switches
51Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm
52Provision for providing and laying of brick tile edge in composite mortar 1:4 (1cement, 4 coarse sand) over bed of 20mm thick mortar including filling of joints. Curing all complete
53Provision for providing and fixing of first class tile brick masonry for toe wall in pathway in the ratio 1:4 (1 cement, 4 coursesand ) etc. complete.
54Provision for providing and applying of recess pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand) after raking, cleaning and washing of joints complete.
55Provision for providing and installing M.S. Fiber portable cabin including PUF/wooden panel for heat resistance with one room and washroom for officials visiting during excavation of size 6.00m(L) x 3.00m(W) x 3.00m(H) in white colour as per specifications given below. [Walls, 1.25 mm thick corrugated HR sheet., Inside panel material for sides, end walls & roof consists of 8 mm thick pre-laminated board., Side Panel frame made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick, Roof, One side slop roof with water resistance technique. Roof will be provided so that water cannot come inside the shelter, Roof frame made of MS having stiffner Top 40 mm x 20 mm x 3.2 mm thick, Floor, MS 50x50x3.2mm tube frame with wooden ply of 19mm finish with vinyl flooring on the top and post must be at least 10 inches above ground level, Door, One complete door of size 3’ x 7’ with Hinges, door lock and handle, Window, Two side powder coated aluminium sliding windows with 4 mm tinted Glass of size 3’ x 3’, Electric, One tube light point, two fan point and one power plug and one normal plug point will be provided along with all necessary wiring (concealed) and fittings completed and 20-watt LED light with holder, two mounted wall fan to be provided, Double pole MCB 20A with metal enclosure - continuous earth wires to be provided and also external earth terminal to be provided, Plumbing, Complete necessary internal plumbing and sanitary fitting along with approved brand and quality items given below, 01 No. of PVC water tank 1000 Lt. on MS frame of appropriate size, 01 No. of WC seat, 01 No. of washbasin, 01 No. of Towel stand, 01 No. of soap stand, 01 No. of mirror, 1 no. of 25 lit geyser , 1 No of towel ring, Two coats of synthetic enamel paint to be applied on expose structure and all MS items after installation including construction of platform of cement concrete for porta cabin and laying and fixing of sanitary pipe line to the chamber/ construction of chamber all complete.
56Providing other items for each porta cabin: i) 2 nos of Metal almirah as required for porta cabin as shelf with 3 way bolting system with full length locker inside, ii) 2 nos. of Wooden bed for officials of size 6*4 ft. iii) 2 nos. of wooden Office table of size 3*2 feet iv) 2 nos of Office chair for adjustable dimensions, and breathable material as as directed by the Engineer-in-Charge.
57Providing and fixing Y-angle post/iron arm of size 50×50×5 mm in position for concertina coil. The item includes cutting, hoisting, placing in line, level, and position, slanting/splitting into 'Y' shape, drilling required holes, and fixing/welding with structural steel posts, boundary walls, or embedded base plates/cleats. The work covers all necessary welding, jointing, grinding smooth, and applying a priming coat of approved steel primer (red oxide/zinc chromate) and color paint after thorough surface preparation, complete as per standard specifications, detailed architectural/engineering drawings, and as directed by the Engineer-in-Charges (DSR 2023 item code 10.25.2)
58Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre.(DSR 2023Item no. 16.53) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58032043
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 03-11-2026
Authority
Authority Name Archaeological Survey Of India
Work Description Tender for Execution Of Work Under Providing Interpretation Center, M.S. Porta Cabin And Other Development Works At Ancient Mound Agroha, Hisar, Haryana
Basic Detail
Tender No 3/17/C/SR-2026/CHD
Bidding Type Tender
Location
City Hisar
State Haryana
Key Dates
Publish Date 14 Oct 2026
Submission Date 03 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 1.22 Lakhs
Exemption Available
Document List
7fb5b568-6eef-4e32-9da1-858481f57efe.html
BOQ_977637.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

7fb5b568-6eef-4e32-9da1-858481f57efe.html

xls

BOQ_977637.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender