Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58031200

Tender For Special Repair To Bldg No P-16 And T-84 At Mendhar Under Age B/R-I Of Ge 881 Ews

Issued by Statutory Bodies & Commissions/Committees · Poonch, Jammu and Kashmir
Tender Value
36.65 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
8 days left
EMD
73300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg No P-16 And T-84 At Mendhar Under Age B/R-I Of Ge 881 Ews

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-Oct-2026 CORRIGENDUM Date 10-Nov-2026

BOQ

Name of Work:- SPL REPAIR TO BLDG NO P-16 AND T-84 AT MENDHAR UNDER AGE B/R-I OF GE 881 EWS
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: SPL REPAIR TO BLDG NO P-16 AND T-84 AT MENDHAR UNDER AGE B/R-I OF GE 881 EWS Contract No : GE/PNH-72/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
3Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
4Description all as per item no. 02 above but except stone (using old serviceable stone after cleaning) complete all as specified and directed.
5Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
6Demolition of cement concrete (reinforced) of any description and in any position (reinforcement cut as required to facilitate demolition),complete all as specified and directed.
7Demolition of cement concrete (including floor tiles/kota stone flooring) (unreinforced) of any description and in any position ,complete all as specified and directed.
8Formwork to flat sides rough finished of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
9Reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in beams, cantilevers, bresssummers, lintel over 1.5m span etc complete all as specified and directed.
10TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
11All as per Srl item no 09 above but 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders complete all as specified and directed.
12Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. and getting out in any type of soil, complete all as specified and directed.
13Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, in any type of soil, complete all as specified and directed.
14Removing excavated material (soil) exceeding 250m but not exceeding 500m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
15Removing excavated material (soil) exceeding not exceeding 50m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
16Demolition of cement concrete (unreinforced) of any description and in any position,complete all as specified and directed.
17PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete ,complete all as specified and directed
1825 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor, surface finished even and fair, complete all as specified and directed.
19Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
20Vitrified Ceramic tiles 9-10 mm thick area of each tiles light shade not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4,complete all as specified and as directed by Engr-in-Charge
21Description all as per item No 19 above but as in vertical surface in skirtings,dados including 10 mm thick back coat in CM 1:4, complete all as specified and as directed by Engr-in-Charge
22Coloured exterior heavy duty Endura tiles with chemical resistant coating of size 400mmx400mmx10/12mm thick and laid in floors/path etc, set and jointed with neat cement slurry and pointed with coloured cement to match the shade of the tile over and including 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and directed.NOTE: Shade/colour of tile shall be approved by the GE.
23Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
24Glazed ceramic coloured tiles of size 450x300mm x 7/8mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge.
25Description all as per item no 23 above but in skirting, including 10mm thick back coat in CM 1:6 complete all as specified and directed.
26Taking down existing tarfelt including tiles and demolition of concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed.
27PCC type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and finishing surface smooth and even to maintain levelling to existing slab complete all as specified and directed.
2810mm thick screed bed or bedding layers in cement mortar (1:4) on roof slab including parapet and including mixing of liquid water proofing compound @ 200 ml per 50 kg of cement bag complete all as specified and as directed. Note:- WPC shall be measured and paid separately
29Roof surface treated with PU Elastoseal primer to seal the pores and enhance the adhesion of the coating, supplying and applying single component waterproofing liquid membrane based on pure, elastomeric, polythene resin cold applied of spray/brush applied membrane with an elongation of 650+50% and tensile strength not less than 2 Mpa. Crack bridging ability not less than 2 mm. No leakage upto 5 bars of water pressure. Shore hardness > 50 shore. The minimum thickness to be applied shall be 1.5mm (overall) in two layers ( each layer 750 micron) or as per manufacturers instructions so as to acheive thickness not less than 1.5mm including providing and laying of protective Geotextile fabric 150 GSM over the entire area with proper overlaps of 75mm including ponding test with water minimum for 72 hrs complete all as specified and directed by Engineer-in-charge.Note: (i) The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer.(ii) Payment will be made after providing warranty certified from the company and succesfull ponding test with no leakage observed.(iii) Makes of PU primer/ membrane:- SIKA/BASF,BERGER/STP FOSROC/SAINT GIBAIN/PIDILITE,DR FIXIT
30Supply only liquid water proofing compound.
31Taking down cement plaster from brick or stone walls, hacking for keys & scrubbing down with water including raking out joints etc as in patches complete all as specified and directed.
32Rendering 15mm thick on fair faces of brick wall orconcrete surfaces in cement mortar 1:4 including mixing of water proofing compound as per manufacturer's instruction and finished the surface even and smooth without using extra cement, complete all as specified and directed. Note:- Supply only WPC shall be measured and paid for separately.
33Rendering 10mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:6 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
34GI wire chicken mesh of size 25mmx25mm in concrete joints etc in walls, ceiling, stanchions, beams etc including all laps, cutting and waste complete all as specified and directed.
35Rough cast plaster complete all as specified and directed.
36Rendering 5mm thick on fair faces of ceiling using cement mortar 1:3 and finished the surface even and smooth without using extra cement, complete, all as specified and directed.
37Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width or girth including cutting to edges all mitres and stopped ends complete all as specified and directed.
38Preparation of newly plastered or unplastered surface of wall and applying two coats of cement base paint in camouflage pattern over a coat of Primer complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge.
39Applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint in varrious colour of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces in camouflage pattern complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge.
40Preparation of newly plastered or unplastered surface of wall and applying two coats of Oil Bound Distemper (any tint) over a coat of primer including 2mm thick wall care putty complete all as specified and directed
41Preparation of old decorated plastered surface on wall and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint in varrious colour of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over in camouflage pattern complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge.
42Preparation of old decorated wall surfaces of any description and applying two coats of Acrylic emulsion paint complete all as specified and directed.
43Preparing old decorated surface on wall and applying two coat of distemper oil emulsion (OBD) complete all as specified and directed.
44Preparing old decorated surface on ceiling and applying one coat of distemper oil emulsion (OBD) complete all as specified and directed.
45Preparing old decorated surface on wall and applying one coat of cement base paint in camouflage pattern complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge.
46Taking down chowkhats or frames n. exc 1.5 Sqm with shutter (without taking off shutters from frame) complete all as specified and directed.
47Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket [12:19 pm, 13/10/2026] Himanshu JE QSC GE 881 Pratap: etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
48Powder coated anodised aluminium window and ventilator shutter, side hung type without sash aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing anodised aluminium fitting such as peg stay 150mm long (01 No) hinges type B-21 100mm long (02 Nos) suitable handle (01 No) complete all as specified and directed.
49Sheet glass ordinary quality, 5.5mm thick, glazing with rubber neoprene packing to aluminium frame in squares exceeding 0.50Sqm in each pane fixed in repairs, complete all as specified & directed.
50Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
51Factory made solid panel PVC door shutter 30mm thick(Stiles) consisting of frame made out of MS tubes for top and bottom rails. MS frames shall be covered with heat moulded plain coloured PVC,C, channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame with 3 Nos stainless steel hinge 100 mm size, welded/sealed to the stiles rails with suitable PVC sheet beading and jointed together with solvent cement. S&F in the frame as per manufacturer's instructions complete all as specified and directed.
52Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed.
53Factory made pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fasts complete all as specified & directed.
54Factory made pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fasts complete all as specified & directed.
55Plain cement Concrete 1:2:4 type-B0 (using 12.5mm graded crushed stone aggregate) as in holdfast, plinth band, bed blocks, benching and like slightly rounded or chamfered angles including necessary form work, complete all as specified and directed.
56Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide zinc chrome primer to new or previously untreated steel surfaces not exceeding 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
5735mm thick 2nd class hard wood(Sal/Hollock) plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified & directed.
5835mm thick 2nd class hard wood (Sal/Hollock) Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified & directed.
59Preparation of new wooden surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer,complete all as specified & directed.
60Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified & directed.
61Stainless steel wire cloth 0.63 nominal dia of wire and average width of aparture 1.20mm and fixed with tinned tacks or galvanised wire staples, complete all as specified & directed.
62100 mm long, butt hinges , cold rolled mild steel, medium Weight complete all as specified and directed.
63Extruded aluminium alloy handles, fabricated type, anodised of size 150 mm and fixed, complete all as specified and directed.
64Aluminium anodised, barrel tower bolts of extruded section of size 150 and fixed, complete all as specified and directed.
65Aluminium anodised, barrel tower bolts of extruded section of size 200 and fixed, complete all as specified and directed.
66250mm long aluminium alloy anodized sliding door with haps, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed.
67300mm long aluminium alloy anodized sliding door with haps, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed.
68S&F in repair floor door stopper of aluminium alloy body with over all length of cover plate of 140mm and tongue, anodised with hard drawn, steel spring, fixed in floor complete all as specified and directed.
69300mm Mild steel helical door spring stove enamelled black including roller and roller plate complete with screws, fitted to wooden frame work or welded to nsteel frame complete all as specified and directed.
70300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
7150 mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
72Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
73Steel water tubing of 20 mm dia bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed.
74Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
75Steel water tubing of 15mm dia bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and directed.
7615mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified and directed.
7720mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified and directed.
781000 ltr capacity rotational moulded polyethylene water storage tanks, double layer(Cylindrical vertical with threaded close top), ISI marked and fixed in position, all as specified in SSR Part-I, including dismantling of old water tank of any description, complete all as specified and directed.
79Tank nipple suitable for HDPE water tank (Minium weight 15mm-38gms/20mm-45gms/25mm-65gms) complete all as specified and directed.
8020mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) fixed in repairs, complete all as specified and directed.
81Bib taps 15mm bore of cast copper alloy chromium plated, fancy type,long shank, screwed down, high presure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule, fixed, complete all as specified and directed.
82S &F in repair 15mm bore pillar tap, cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule complete, all as specified and directed
8315mm bore Stop valve cast copper alloy chromium plated fancy type with long shank and cup (concealed type) screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified and directed.
84Supply & fixed in repair, 15mm bore angle stop valve of PTMT any colour high pressure screwed for iron pipe or fixed (minimun weight 15mm-90grms), fixed, complete all as specified and directed.
8515mm bore Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed in repair complete all as specified and directed.
86Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed.
87Supply & fixed in repair, Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed.
88Wall mount corner glass shelf assembly consisting of 5.5mm thick sheet glass shelf of 12cm wide with cromium plated bracket guard and railing 60cm long and fixed in position complete in all respect as specified and directed.
89S&F in repairs 18 mm thick vitreous china ware urinal partition white slabs, top curved terminating about 40 cm above from floor of size 310x700mm, inserting in wall complete all as specified and directed.
90S&F in repair 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified and directed.
91S&F in repair 600x450 mm size and 5.5mm thick looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel alround, mounted on 6 mm thick commercial ply or AC building board, fitted to wooden plug with CP screws, complete all as specified and directed
92S&F in repair vitreous china half stall urinal (back or cornerwall type) complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plugs with and including 60mm long brass screw, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe and waste pipe (1st quality) with white grating and unions for discharge pipe complete all as specified and directed.
93S&F in repair vitreous china squatting pan of pattern, long pan, orissa pattern size 580x440mm white with integral foot rests (excl flushing cistern and flush pipe) but including provision of lime concrete complete all as specified and directed.
94S&F in repair vitreous China wash down water closet pan (pedestal pattern),white (excluding fixing bolt,flushing cistern and flushing pipe) complete all as specified & directed.
95S&F in repair Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised or PVC hinging device fixed in repairs, complete all as specified & directed..
96S&F in repair PVC valve less, symphonic action type flushing cistern 10 ltrs capacity low level, with inlet, ball valve float, flush pipe and handle including brackets complete all as specified & directed.
97Vitreous china wash hand basin, white , flat back, size 580 x 450 mm with brackets, including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
98PVC (SWR), Type B, 110mm dia any length single socketed with rubber ring joint, laid in floor/walls as soil pipe(vent pipe), fixed in repair, complete all as specified and directed.
99PVC (SWR) bends/tees suitable for 110mm external dia complete all as specified and directed.
100PVC (SWR) vent cowl for 75mm dia fixed in repair, all as specified and directed.
101PVC (SWR), type B, 75mm dia any length single socketed with rubber ring joint, laid in trenches/floor as soil pipe(vent pipe), fixed in repair, complete all as specified and directed.
10275mm bore PVC (SWR) bends any radius fixed in floor in repair all as specified and directed.
103S & F in repairs flexible waste pipe for wash hand basin fitted to Wash Hand Basin incl all necessary brackets etc all as specified and directed by Engr-in-Charge.
104PVC connection 15mm size with PTMT nuts on both ends of length 450mm fixed, complete all as specified and directed.
105S&F in repair waste coupling 32mm dia of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60gms) complete all as specified and directed.
106PVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75mm diameter of outlet,complete all as specified and directed.
107Stainless steel S-304 grade, heavy duty,decorative curtain rod 25mm dia with decorative head on both end of rod and necessary clamps / fixing brackets, stops, rollers etc complete all as specified and as directed.
108Demolition of stone slab and tiles of any description and thickness in floors, aprons etc laid and pointed in any mortar, complete all as specified and directed.
10918-20mm thick granite (of approved type colour) work (table rubbed & polished) in jambs, pillars, window cills, cooking plateform laid over and including 15mm thick cement screed (1:4) and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the colour of granite stone including cutting and and moulding the edges, complete all as specified and directed.
110Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
111Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'B' complete all as specified and directed.
112Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified & directed.
113Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed by Engineer- in Charge.
114Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws asspecified complete all as specified and directed.
1152mm thick fibre glass reinforced translucent with light colour corrugated sheeting with two corrugation side lap fixed with L type or J type hook and washer in roof, wall, as in ridge covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-charge.
116Plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in surface channels complete all as specified and directed.
117Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
118PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in bed concrete to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested ,complete all as specified and directed
119PVC (SWR), type B, 150mm dia any length single socketed with rubber ring joint, laid in trenches/floor as soil pipe(vent pipe), fixed in repair, complete all as specified and directed.
120Plain cement Concrete 1:2:4 type-B-1 (using 20mm graded crushed stone aggregate) as in copings, roof kerbs;moulds, benching and like slightly rounded or chamfered angles including necessary form work, complete all as specified and directed.
121Dismantling and removal of existing old partition board, including removal of supporting frame, wherever required, carefully taking down the boards, stacking serviceable materials at the designated location, and disposing of unserviceable debris complete all as directed by the Engineer-in-Charge
122Powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and directed.
123EPM particle board 5mm thick, interior grade, prelaminated both side with decorative choice lamination and fixed with screws to timber frame work complete all as specified and directed.
124Chequered cement concrete coloured tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed in white or coloured cement mixed with pigments to match with the colour of tiles, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
125Dismantling of timber scantling 40sqcm and over in section unframed work,as in any position, complete all as specified and directed.
126Preparation of old steel or iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
127Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
1284mm thick non asbestos fiber board of size 600mmx600mm fixed or laid/inserted to power coated GI frame work grid size 605x605mm and including 3mm thick GI wire at every 1200mm c/c of required length fixed in RCC roof/truss and etc and complete all as specified and directed by Engr-in-Charge.
129M&L for Providing and fixing of double rebate openable/fixed windows made of galvanized steel, colour coated/powder coated (base steel as per IS 513 of “D\\" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 mm, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, outer frame section 72 x 55 mm, centre mullion section 72 x 50 mm, shutter section 47 x 20 mm, fly mesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consists rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the sections cut to length mitre joined with corner bracket, centre mullions fixed with mullion cap, stay, handles, latch, 2 Nos of heavy duty stainless steel pivot hinges per shutter and panelled with 5mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self-expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. complete all as specified and directed.
130E/M PORTION:-Taking down carefully copper/ aluminium unserviceable/ perished point wiring with casing caping (light, fan, socket or power complete) including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site and making good disturbed surfaces of wall, floors, complete all as specified and directed.
131Point wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through including PVC casing caping and provisining of 1.5 sqmm FRLSH PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches, sockets outlets,regulators etc complete One light/Fan point controlled by one switch 5 amp one way complete.
132All as per item No.130 but One 3 pin 5 Amps socket point controlled by one switch on same board.
133All as per item No.130 but One 3 pin 5 Amps socket point controlled by one switch on independent board.
134All as per item No.130 but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLSH PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
135Submain wiring with 2 runs of copper conductor FRLSH PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC casing caping 25mm dia ISI marked as per IS specification fixed on wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLSH multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length complete all as specified and directed.
136Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
137Socket outlet multipurpose combination 2 in 1, 3 pin, 5 Amp flush type universal,complete all as specifed and directed.
138Switch piano flush type single pole, one way 15 amp complete all as specified and directed .
139Socket outlet multipurpose combination 2 in 1, 3 pin, 15 Amp flush type universal,complete all as specifed and directed.
140Ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed.
141Step type fan regulator electronic type in 5 step, 100 watt capacity switch/socket type complete all as specified and directed.
142Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
143S&F in repair Inverter LED Lamp, CDL, 9 watt, B22 base all as specified and as directed.
144Inverter LED light fittings, 1x20 w LED, 230 V complete with all accessories internally per wired including lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours and connecting up with PVC insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified directed.
145LED tube light fittings mirror type with high out put diffuser 2 feet , 10 watt 220 volt AC decorative box type with driver and connecting up with three core flexible copper conducor cable of suitable size from ceiling rose complete all as specified and directed.
146Distribution board double door type (for incoming MCCB & outgoing MCBs) TPN 4 way vertical type sheet steel powder painted with bus bar, neutal link & earth bar etc with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed.
147Sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 08 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
148MCCB 100 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
149MCBs SPN 63 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
150MCBs SPN 40 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
151MCBs SPN 5 to 32 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
152Exhaust fan, Steel body AC single Phase. 230V of size 300/380mm sweep with, blades, and frame and louvers complete all as specified and as directed.
153Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades, complete all as specified and directed by Engineer-in-Charge.
154Rewinding the ceiling fan 1200mm Sweep with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to original place all as specified and directed by Engineer-in-Charge.
155Painting of ceiling fans and writing of MES No on fans in situ with synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc, complete all as specified and directed by Engineer-in-Charge.
156Ceiling fans complete with three blade, down rod, accessories 230V, 1200mm sweep, BLDC fan with 5 star rating including fan refulator complete all as specified and as directed.
157Electric water heater,storage type steel body with inner tank and heating element upto 1.5 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
158Bus bar chamber of size 600x600x450mm suitable of 3 phases 433V outdoor type fabricated out of 3.15mm thick MS sheet with 300A rated aluminium bus bar 4 Nos, PVC sleeves (coloured red, yellow, blue and black) with suitable looking arrangements and fourr legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20 mm graded stone aggregates alongwith all necessary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer complete all as specified and directed.
159Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead strip 25 x 4 mm size upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
160Energy efficient LED light fitting, 45W, input voltage 110V to 280VAC, 50Hz with ingress protection IP 66, LM 80, stranded luminries with efficiency 100 lumen/watt, with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70, PF>0.95, with short circuit & reverse circuit protection against 10 kV high surges, minimum 25000 burning hours (life), operating temperature 1 to 50 degree Celcius , rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45W=10%W, rated lumens, 120 degree view angle, constant current type driver having THD<10%, including all fixing arrangement like clamps, nuts, bolts, washers, 45W LED rod lamp (having PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc including bracket complete all as specified and directed.
161Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
162Approved quality clean dry sharp sand as in cushioning to under ground cable laying 15cm thick before laying and 8cm after laying the cable in trenches for cable cushioning, complete all as specified and directed.
163Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
164M&L for cutting to road/cement path/hard standing/Road for providing GI pipe 40mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed.
165GI tubing 40 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position all as specified and directed.
166Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed.
167Ceiling mounting LED light fittings luminaire 600mmx600mm, 35/36 watt, 220 v, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver , holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
168Sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
169Sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 04 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58031200
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36.65 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No P-16 And T-84 At Mendhar Under Age B/R-I Of Ge 881 Ews
Basic Detail
Tender No GE/PNH-72/2026-27
Bidding Type Tender
Location
City Poonch
State Jammu and Kashmir
Key Dates
Publish Date 28 Oct 2026
Submission Date 10 Nov 2026
Open Date 14 Nov 2026
Finance
Tender Value 36.65 Lakhs
Tender Fee 500
EMD 73300
Exemption Available
Document List
e74bf265-ae92-42a3-8367-cc3e0c053862.html
TENDER.pdf
Tendernotice_1.pdf
BOQ_890062.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 10, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

e74bf265-ae92-42a3-8367-cc3e0c053862.html

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_890062.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender