Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58031152

Tender For Providing Of Certain B/R And E/M Work At Atc Of Af Stn Mohanbari

Issued by Statutory Bodies & Commissions/Committees · Dibrugarh, Assam
Tender Value
43 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
19 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Certain B/R And E/M Work At Atc Of Af Stn Mohanbari

BOQ

Name of Work:- PROVN OF CERTAIN B/R AND E/M WORK AT ATC OF AF STN MOHANBARI
Sl. No. Item Description
1Surface excavtion in soft/ loose soil n.exc 30 cm in depth and averaging 15 cm deep and getting out complete all as specified and directed.
2Excavtion in trenches, n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundations, etc or for shafts,wells, cesspits, manhole, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 mtr in depth in soft/ loose soil and getting out complete all as specified and directed.
3Excavating in trenches, n.exc 1.5 m wide and exc 1.5 mtr depth beyond the first 1.5 mtr depth for foundation etc complete all as specified and directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in depth complete all as specified and directed.
5Removal of excavted soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
6M&L for Portions ordered to be dismantled of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
7M&L for demolition of cement concrete if cement concrete is reinforcement (reinforcement cut as required to facilitate demolition) concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
8M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate crushed stone aggregate as in foundations/ mass concrete complete all as specified and directed.
9M&L for RCC M25 (design mix) as in foundations, footing, plinth beams complete all as specified and directed.
10M&L for RCC M25 (design mix) as in columns and roof beam complete all as specified and directed.
11Use and waste of formwork to sides of concrete foundations, footings, sides and soffits of foundations (if any) of foundation and plinth beams and similar work, verticalor to batter for rough finished surfaces complete all as specified and directed.
12Use and waste of formwork to sides and soffits of floors or roof beams ,beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc splays between floors and beams for flat fair finished surfaces complete all as specified and directed.
13Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor fair finished surfaces complete all as specified and directed.
14M&L for TMT steel bars as in reinforcement, 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and blinding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clipscomplete all as specified and directed.
15All as item no 14 above herein before but 8 mm dia and over upto and including 10 mm dia as in stirrups ,spacers and blinders etc complete all as specified and directed.
16M&L for Fe410-W(Gde-250) quality B roof truss (framed), trussed, prulins, crane gantries, rails and fasteining and heavy bracket framing (beams, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified and directed.
17M&L for girder or single stanchion, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed.
18M&L for mild steel bolts of 20 mm dia purpose made with hexagonal or square head one end and serewed other end or screwed both ends, each serewed end to end fitted with washers and one hexagonal or squarre nut, exc 30 cm long complete all as specified and directed.
19S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet .50 mm thick having tensile strength of 550 mpa as in roof covering /ridge /cladding to wall, fixed with self tapping screw (heavy duty) with in built washers and neoprene and EDPM washers ,in roofs,walls etc complete all as specified and directed.
20S&F for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick having tensile strength of 550 mpa as in ridges, hips, valley gutter, drip or straight fastening etc fixed with self tapping screw etc complete all as specified and directed.
21M&L for brick work with sub class 'B' bricks (old size), straight or curved on plan exceeds 6m mean radius,built in cement mortar 1:4 complete all as specified and directed.
22M&L for Rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete sur faces even and smooth without using extra cement complete all as specified and directed.
23M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete sur faces even and smooth without using extra cement complete all as specified and directed.
24Hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface for plinth protection/ under floor complete all as specified and directed.
25M&L for 75 mm thick plain cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protection complete all as specified and directed.
26M&L for 100 mm thick plain cement concrete TypeD-2 1:4:8 (using 40 mm graded stone aggregate) as in paving/ under floor complete all as specified and directed.
27M&L for Preparation of new steel Surfaces of any description, over 10cm in width or girth,of any description and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed.
28Providing and fixing false ceiling of Non asbestos fiber cement board /designer tile prepainted (high pressure steam cured ) of 4mm thick (as per IS: 14862:2000 type B catagory -3) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on and including inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 24x38 mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 24x38 mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 24x38mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engr-in-charge. Note the exposed/visible surface of metal surface frame work shal be powder coated of mim 40 micron complete all as specified and directed.
29M&L for Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminum Sliding Windows 2-Tracks with 2 Sliding Shutters with Extrusions Aluminum of following Sections including Jointing Cleats, Glazing Clips, Rubber Packaging, Snap Beading and other necessary Aluminium Builders Hardware as required complete all as specified and directed :- (A) FRAME :-(i) Top and Side Member for 2 Track Frame of Size 61.85x31.75x1.5mm (Weighing 0.784 KG/RM), Model No. 20829 of Make : Jindal or equivalent.(ii) Bottom Rail of Frame for Sliding of Size 61.85x31.75x1.5mm (Weighing 0.909 KG/RM), Model No. 20830 of Make : Jindal or equivalent.(B) SHUTTER :-(i) Top and Bottom Rail of Sliding Shutter of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20736 of Make : Jindal or equivalent.(ii) Side of Sliding Shutter with Handle and Self Locking Arrangement, Section of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20738 of Make : Jindal or equivalent.(C) Sliding Shutter to be provided with 5.0mm thick Sheet Glass.(D) Aluminum Diamond Grill 6.5mm thick with Mat Finished fixing on Wall/ Wooden Chowkat/ Aluminium Frame with suitable Size of Aluminum 'U' Channel and Steel Chromium Plated, Screw with Rawel Plug with following Details :-(i) Aperture Size of Aluminum Grill 67x84mm.(ii) Cord Dimension 7.0x5.8mm.(iii) Plate thickness 3.0mm.(E) Stainless Steel Wire Cloth, 0.36mm Nominal Dia of Wire and Average Width of Aperture 1.40mm and fixed with Stainless Steel Wire Staples/ Clip/ Aluminium Flat
30S&F for Mild Steel Curtain Rod/ Harrison Rail 20mm Dia, Chromium Plated with Brackets, Stops, Rollers, fixed on Walls complete all as specified and directed.
31M&L for Green Marble Work 18mm to 20mm thick (Table Rubbed and Polished) in Steps, Jambs, Pillars, Window Cills, Cooking Platforms and like in Cement Mortar 1:4 including Pointing in White Cement 1:2 Using Marble Dust with Admixture of Pigment to Match the Shade of Marble including Grinding and Polishing, Fixing over and including 20mm thick Cement Screed Bed in cement mortar 1:6 complete all as specified and directed.
32M&L for preparation of new plastered surfaces and applying two coats of Oil Bound Disterper over a subsequent coat complete all as specified and directed.
33M&L for preparation of old plastered surfaces with complete removing of existing surfaces and applying two coats of Oil Bound Disterper over a subsequent coat complete all as specified and directed.
34M&L for Preparing Newly Plastered Surfaces of Walls and Applying Two Coats of Acrylic based Weather Coat Exterior grade Emulsion Paint (any Tinted) in Camouflage Pattern Over a Coat of suitable Primer (as specified by Manufacturer of Paint) including Cleaning Drops from Joinery, Glasses, Electrical Fittings and Washing Floors etc complete all as specified and directed.
35M&L for cement concrete 1:2:4 (20 mm graded stone aggregates) in Lintels upto 1.50 mtr clear span, cills, steps, Seismic and other similar bands, plinth courses, String courses, parapets and railings upto 600 mm in Height, Copings, kneelers, Apex stones, Bed plates, water Troughs and the like including Weathering. Slightly Rounded or Chamfered Angles and throating, Finishing all exposed Faces of Concrete including Use and waste of Formworkas required / ordered complete all as specified and directed.
36M&L for Sand filling and/or Sand Cushioning under floor or interlocking Paver blocks, etc. including Watering (if required) and consolidation complete all as specified and directed.
37M&L for Machine pressed Pre-cast concrete Interlocking Paver block 60 MM thk of M-35 Grade, with grey cement and pigment of any shape and size (as ordered), conforming IS-15658-2006 complete all as specified and directed.
38M&L for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed.
39M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed bease laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
40M&L for Screed bed or bedding layer of mortar 10mm thick for laying floor finishes in cement mortar 1:4 complete all as specified and directed.
41M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
42Supply only integral water proofing compound complete all as specified and directed.
43M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
44M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
45M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
46M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
47M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
48S&F for Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed.
49S&F for 1.60 mm thk Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood orsteel framing with plain 40 mm lap joints with riveted or weldedseams, including bending or turning up, mitred angles etc as required complete all as specified and directed.
50S&F for Fe 410-W (Gde E- 250) quality -B Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed.
51S&F for Fe 410-W (Gde E-250) Quality B Stairs (framed) including stringers, treades, landing, balusters, hand rails etc in cluding cleats, brackets etc complete all as specified and directed.
52Taking down existing unserviceable roof treatment of any description including cement plaster, any thickness from roof surface, cleaning of roof surface and preparaing it for further treatment and removing the debries / rubbish material from site complete all as specified and directed.
53M&L for preparation of plastered/concrete surfaces of Bldg roofs & tarraces, parapets, sunshades and exterior walls by brushing/brooming/blowing and applying HS Roof Kool & Seal fibre reinforeced liquid applied elastomeric waterproofing membrane, impregneated with nano-fibre and formulated with PU-Acrylic Hybrid Polymer complete all as specified and directed.(A) Method of Application:-(i) The surface to be applied should be clean & sound ,free from any kind of contamination, dirt, tar/bitumen coating etc. (ii) Oil & Greese must be removed using degreasing solvents.(iii) Any damaged surface must be repaired by using crack fillers or polymer modified repair mortar using ADVANCED LATES PLUS as per Manufacture direction.(iv) Angular fillets-Hampering of junction of any right -angled corner( 50mm x50mm) & repairing the same using polymer modified mortar in1:4 ratio (cement sand) admixed with HS Advanced Latex Plus @3% by weight of cement.(v) Application of Primer:- Providing and applying single coat of HS PU Roof Kool& seal using brush/ roller after diluting the water in 40% ratio by volume (as per manufactures specification ) as the primer coat .Allow the primer to dry for 3-4 hours prior to waterproofing coating application.(vi) Application of HS Roof Kool & Seal :- providing and applying two coats of HS Roof kool & Seal (Non -diluted )up to vertical wall 300 mm. Retention 4-5 hours. One component water based ,high soild, UV resistant hybrid Polyurethane membrane with 300% elongation,as per ASTM D412, for long lasting waterproofing SRI 107.
54HORIZANTAL WATERPROOFING:- ( By using :-HS Roof Kool & Seal Product)Stage Dliution Tool Inter coat period Forced coverage (Composite system)Self priming 40% with Hard brush 3-4 Hrs potable water / RollerWater proofing Undiluted - 4-6 Hrs 1.0-1.1 sqm/ltr 1st coat (for 03 coats application)Water proofing Undiluted - 4-6 Hrs 1.0-1.1 sqm/ltr 2nd coat (for 03coats application)The cured applied system shall achieve a total dry film thickness of 450-500 microns.VERTICAL WATERPROOFING:- ( By using :-HS Roof Kool & Seal Product)Stage Dliution Tool Inter coat period Forced coverage (Composite system)Self priming 50% with Hard brush 3-4 Hrs potable water / RollerWater proofing Undiluted - 4-6 Hrs 1.65-1.85 sqm/ltr 1st coat ( for 02coats application)
55M&L for rendering 20 mm thick plaster on concrete surfaces or on fair faces of brick work in cement mortar 1:3 finished even and smooth with out using extra cement complete all as specified and directed.
56M&L for consealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including modular metal flush box, including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :-
57Description all as per item No 55 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and directed.
58Description all as per item No 55 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed.
59Description all as per item No 55 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed.
60Description all as per item No 55 here in before but using 2.5 Sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 Sqmm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed.
61S&F for ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
62S&F for modular swith 6/10 Amp one module complete all as specified and directed.
63S&F for modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and directed.
64S&F for modular switch 1 way 16 Amps, 1 module, 230 volt complete all as specified and directed.
65S&F for modular socket 1 way 6/16 Amps, 3/3 pin combined, 2 module, 230 volt complete all as specified and directed.
66S&F for white cover plate with frame 3 module complete all as specified and directed.
67S&F for white cover plate with frame 6 module complete all as specified and directed.
68S&F for LED lights fitting 1 X 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make Crompton Cat Part No :-TCS-108-20-65-SL-DP-NWH/Havells cat Part No:- LHEXAZP7IN1W020.
69S&F for recessed mounted 36 Watt (clear white) LED panel light 2x2 feet, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp complete all as specified and directed. Make Crompton Cat Part No :-TCR-145-36-65-SL-NWH/Havells cat Part No:- LHEBAEP7IW1W036.
70S&F for copper wound ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Energy efficient, five star rated, with brushless direct current motor (BLDC) complete with mounting arrangment as per site requirement and connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed.
71S&F for wall fan size 400 sweep, speed 1350 RPM, single phase AC 230Volts complete all as specified and directed.
72M&L for flame proof concealed point wiring with 1.5 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed 1100 V grade multistranded copper conductor single core cable drawn through and including 20 mm dia stove enamelled ERW Steel conduit screwed medium grade with all flame proof fittings and accessories suitable for one light/one fan point controlled by one switch including unsheathed single core standerd copper conductor cable of size 1.5 Sqmm as earth continulty conductor FR-LSH Connected to common earth and earth dolly and to be torminated to boxes as per requirment at site elc. including testing on completion complete all as specified and as directed.
73S&F for LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. Make :-Crompton cat part Number EXTN1LT8-16/20-VE/Sudhir Cat part Number for flame proof light FF/1272/1/20.
74S&F for flame proof exhaust fan size 305 mm (12'') 1440 RPM, CFM 4000, single phase, 230 Volts complete all as specified and directed. Make : Sudhir Cat Part No:- EF/140.
75S&F for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
76S&F for Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/ lsolators complete all as specified and directed.
77S&F for Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete all as specified and directed.
78S&F for MCB SPN 32 Amps, 230 volts, C - curve, 10 kA complete all as specified and directed.
79S&F for MCB SP 10 to 32 Amps, 230 volts, C curve, 10 kA complete all as specified and directed.
80M&L for sub main wiring with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit complete all as specified and directed.Note : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length).
81M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6.3mm thick electrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mir deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to Gl wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board /DB/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm Gl tubing light grade for protection including testing on completion all as shown in Electrical Plate No 3 of SSR Part-l complete all as specified and directed.
82Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and directed.
83Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
84Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and n.exc 1.5 m in depth and getting out for taking up / laying under ground electric cable complete all as specified and directed.
85Supply and laying sub class B bricks of size 23cm x 115 cm x 7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and directed.
86M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed.
87S&F for air termination single pointed, copper rod 12mm dia and 300 mm long fixed on galvanised iron pipes with copper strip for earth conductivity to ground complete all as specified and directed.Note: MS /PCC work shall be measured and paid seperately).
88S&F for copper strip 20mm x 3mm with fixing screws for conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed.
89S&F for saddle/insulator for earth strip with fixing arrangement in roof/ wall conductors of building/ hangar complete all as specified and directed.
90S&F for gun metal black or phosphorus bronze size 75mm x 75mm x 25mm drilled screwed including 3 Nos, 8mm dia and 25mm long neckhead screws including MS box 2mm thick of suitable size for protection of test point terminal complete all as specified and directed.
91M&L for earthing complete with copper plate 600mm x 600mm x 3.15mm thick electrode and 20mm x 3mm copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to copper strip 20 x 3mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed.
92S&F for Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU) of 1.5 TR with 5 Star BEE Rating capacity. Inverter Type complete all as specified and directed.
93Supplying, installing, commissioning of Voltage stabilizer for utomatic operation, single phase neturally air cooled, indoor type & designed for input variation 130-280 V with output voltage stabilized at 230 Volts with accuracy of +/- 2.5% and capacity 5 KVA complete all as specified and directed.
94S&F for single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete all as specified and directed. Note : Enclosure & MCB shall be same manufacturer.
95M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main complete all as specified and directed.Note :- (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii) Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length). Please Enable Macros to View BoQ information
96M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main complete all as specified and directed.Note :- (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii) Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58031152
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Certain B/R And E/M Work At Atc Of Af Stn Mohanbari
Basic Detail
Tender No 8001/841/E8
Bidding Type Tender
Location
City Dibrugarh
State Assam
Key Dates
Publish Date 13 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 43 Lakhs
Tender Fee 500
EMD 86000
Exemption Available
Document List
54308345-46fd-4861-91ec-d0e0978bb566.html
BOQ_890116.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

54308345-46fd-4861-91ec-d0e0978bb566.html

xls

BOQ_890116.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer