Tender For Repair/Replacement Of Service Connection Of Various Buildings Of Officers Jcos/Ors And Otm Accn Including Bus Bar Chambers Distribution Boards And Allied Works At Lansdowne Under Age(I) Lansdowne
Tender Overview
Project Description
Tender for Repair/Replacement Of Service Connection Of Various Buildings Of Officers Jcos/Ors And Otm Accn Including Bus Bar Chambers Distribution Boards And Allied Works At Lansdowne Under Age(I) Lansdowne
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old unserviceable service cable of any size complete all as specified and directed. |
| 2 | Supply and fixed PVC insulated armoured heavy duty electric cable with aluminium stranded conductor 1100 volts grade of size 25 Sqmm 4 core complete all as specified and as directed. |
| 3 | Supply and fixed PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 1100 volts grade of size 6 Sqmm 3 core cable all as specified and as directed. |
| 4 | Supply and fixed PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 1100 volts grade of size 16 Sqmm 4 core cable all as specified and as directed. |
| 5 | Supply and fixed PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 1100 volts grade of size 16 Sqmm 2 core cable all as specified and as directed. |
| 6 | Supply and fixed PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 1100 volts grade of size 10 Sqmm 4 core cable all as specified and as directed. |
| 7 | Supply and fixed PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 1100 volts grade of size 10 Sqmm 2 core cable all as specified and as directed. |
| 8 | Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. |
| 9 | Taking down old unserviceable DB/VTPN of any size complete all as specified and directed. |
| 10 | S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification. |
| 11 | S&F TPN DB 4 way double door 415 Volt of suitable rated bus bar complete all as specified and directed. |
| 12 | S& F in repair MCB TPN 415 volt of 40 /100 amp capacity 10 KA C series and connection with suitable size of copper lugs complete all as specified and directed. |
| 13 | S& F in repair MCB SPN 240 volt of 40-63 amp capacity 10 KA C series and connection with suitable size of copper lugs complete all as specified and directed. |
| 14 | S& F in repair MCB SP 240 volt of 6-32 amp capacity 10 KA C series and connection with suitable size of copper lugs complete all as specified and directed. |
| 15 | M&L for replacement of existing U/S submain wiring with two single core PVC insulated unsheathed multistranded copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated unsheathed multistranded copper conductor FRLS cable green colour of size 6 sqmm as earth lead in PVC conduit medium grade complete all as specified and directed. |
| 16 | M & L for replacament of existing old unsv earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 17 | S&F in repair Distribution Box VTPN 4 way vertical type with suitable rated bus, suitbale for MCCB as incomer and MCB as outgoing, 415 volts rated in sheet steel enclosure including MCCB of 100 amps thermal megnatic protection double door type complete all as specified and directed. |
| 18 | Supply and fixed in repair “Lithium based Energy Efficient Integrated Solar Street Light 30/32Watt\\" in Single FRP body with duly Polyurethane coating (Customised color), encases with Mono crystalline Solar PV Panel of 65Wp, Lithium Battery 11.1/12.8V, 30AH with inbuilt BMS, IP 66 and IK08, High brightness Warm White -LED(180- 200lm/watt) lamp with Aluminum reflector for better light distribution and, CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-15kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections with Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Supply and installation of 6 meter Hot dip Galvanized Octagonal Pole with 200x 200x 12mm base plate and 16x 600 mm 4 nos foundation bolt. |
| 19 | Supply & fixed in repair in wall mounted BUS BAR chamber 63 Amp 4 way having bus bar of copper materials complete all as specified and directed |
| 20 | Supply & fixed in repair in wall mounted BUS BAR chamber 100 Amp 6 way having bus bar of copper materials complete all as specified and directed |
| 21 | Supply & fixed in repair in wall mounted BUS BAR chamber 63 Amp 6 way having bus bar of copper materials complete all as specified and directed |
| 22 | Supply and fixing in repair rigid non metalic PVC conduit of size 25 mm medium grade inclusive of all tees,bends,albows, reducers,bell mouth tubes and fixing accessories such as couplers,lock nuts,shadles,pipe hooks etc including taking down old unserviceable conduit complete all specified and directed. |
| 23 | Supply and fixing in repair rigid non metalic PVC conduit of size 32 mm medium grade inclusive of all tees,bends,albows, reducers,bell mouth tubes and fixing accessories such as couplers,lock nuts,shadles,pipe hooks etc including taking down old unserviceable conduit complete all specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender