Tender For Overhauling, Dismantling, Repairing & Reinstallation With Supply Shaft, Sleeve, Bearing Etc Of Hsc Pump No.03(Batch-Iii, Q:2305 M3/Hr, H:28M) And Overhauling, Dismantling, Repairing & Reinstallation With Supply Sleeve, Bearing Etc Of Hsc P
Tender Overview
Project Description
Tender for Overhauling, Dismantling, Repairing & Reinstallation With Supply Shaft, Sleeve, Bearing Etc Of Hsc Pump No.03(Batch-Iii, Q:2305 M3/Hr, H:28M) And Overhauling, Dismantling, Repairing & Reinstallation With Supply Sleeve, Bearing Etc Of Hsc Pump No.01( Batch-I, Q:1320 M³/Hr , H: 37.27M) With Allied Work At Kalyani Clear Water Pumping Station Under Kalyani Municipal Area.
BOQ
| Sl. No. | Item Description |
| 1 | Repairing Work of Pump (Batch-III, Sl.No.03) |
| 2 | Dismantling the coupling from motor and closing the butterfly valve and gate valve of suction side and there aftere dismantling & overhauling of the HSC pump set (Q:2305 M3/hr, H:28m, Make: Flowmore) part by part opening the top cover with proper protection as per direction & satisfaction of EIC. |
| 3 | Transportation of pump materials from Kalyani CWPS to Workshop and sending the pump after work complete with loading and unloading as per direction & satisfaction of EIC. |
| 4 | Draw out of total rotating part including bearing, shaft-coupling, gland pusher, bearing housing etc. as per direction and satisfaction of the EIC. |
| 5 | Supply & delivery the new spare parts and repairing / machining the damage spare parts for reinstallation the Pump (Q=2305 M3/hr & H=28M, Make: Flowmore) as per sample dimention, technical specification and direction of the EIC. |
| 6 | Bearing for driving and non driving end. (Make: SKF, No:- 6315-C3 ) (Deducted salvage value) |
| 7 | Pump Driving Shaft as per sample. ( OD = 87.5 mm, L = 1590 mm, Materil- SS 410 ) (Deducted salvage value) |
| 8 | Shaft Sleeves ( OD = 110 mm, L = 420 mm, Materil-SS 304 ) as per sample. (Deducted salvage value) |
| 9 | Gland Pusher (ID=86mm) as per sample. (Deducted salvage value) |
| 10 | Machining the damage / crack driving impleller after metal deposition and finishing / polishing the same. |
| 11 | Machining the Impeller Neck Ring after metal deposition and finishing / polishing the same. (OD = 445 mm, ID = 412 mm ) |
| 12 | Machining the bearing housing after metal deposition, repairing the supporting body and finishing / polishing the same. |
| 13 | Impeller shaft key, Coupling Kee, Coupling Rubber Bush Nut Bolt, Jam Nut, Lock Nut, water guarder of bearing side and other required nut bolt as per sample and technical specification of EIC. (Deducted salvage value) |
| 14 | Gland Packing, Grease and Ruber Gasket for pump and as per sample. |
| 15 | Fitting-fixing all the item no.5.0 (Item No.5.1 to 5.9) spare parts as per direction and satisfaction of the EIC |
| 16 | Dynamic balancing of Rotating Assemblyas as per standard practice and satisfaction of the EIC |
| 17 | Reinstallation repairing pump on the pump-motor base and make proper allignment of the same as per standard practice and satisfaction of the EIC |
| 18 | Recoupling the pump-motor and opening the gate valve of suction side with proper protection ready the 6.6kV breaker ON position as per direction & satisfaction of EIC. |
| 19 | Repairing Work of Pump (Batch-I, Sl.No.01) |
| 20 | Dismantling the coupling from motor and closing the butterfly valve and gate valve of suction side and there aftere dismantling & overhauling of the HSC pump set (Q:1320 M3/hr, H:37.27m, Make:WPIL) part by part opening the top cover with proper protection as per direction & satisfaction of EIC. |
| 21 | Transportation of pump materials from Kalyani CWPS to Workshop and sending the pump after work complete with loading and unloading as per direction & satisfaction of EIC. |
| 22 | Draw out of total rotating part including bearing, shaft-coupling, gland pusher, bearing housing etc. as per direction and satisfaction of the EIC. |
| 23 | Supply & delivery the new spare parts and repairing / machining the damage spare parts for reinstallation the Pump (Q=1320 M3/hr & H=37.27M, Make:WPIL) as per sample dimention, technical specification and direction of the EIC. |
| 24 | Bearing for driving and non driving end . (Make: SKF, No:- 6212 /C4 ) (Deducted salvage value) |
| 25 | Shaft Sleeves. ( OD = 102 mm, L = 215 mm, Materil-SS 304 ) as per sample. (Deducted salvage value) |
| 26 | Neck Ring. ( OD = 335 mm, ID = 310 mm, W=60 mm, Materil-SS 304 ) as per sample. (Deducted salvage value) |
| 27 | Gland Pusher (ID=82mm) as per sample.(Deducted salvage value) |
| 28 | Machining the damage impeller after metal deposition and finishing / polishing the same. |
| 29 | Machining the impeller seal ring after metal deposition and finishing / polishing the same ( OD = 310 mm, ID = 295 mm ) |
| 30 | Machining the bearing housing after metal deposition and finishing / polishing the same. |
| 31 | Supply and delivery of HT M24 x100L Hex Bolt with Nut as per technical Specification and direction of the EIC (Deducted salvage value) |
| 32 | Gland Packing, Grease and Ruber Gasket for pump and as per sample. |
| 33 | Fitting-fixing all the item no. 14 (from 14.01 to 14.09)spare parts as per direction and satisfaction of the EIC |
| 34 | Dynamic balancing of Rotating Assemblyas as per standard practice and satisfaction of the EIC |
| 35 | Reinstallation repairing pump on the pump-motor base and make proper allignment of the same as per standard practice and satisfaction of the EIC |
| 36 | Recoupling the pump-motor and opening the gate valve of suction side with proper protection and ready the 6.6kV breaker ON position as per direction & satisfaction of EIC. |
| 37 | Pole to Pole Damage Cable Repairing Work. |
| 38 | Supply, delivery at site of 1.1 KV grade 4 core x 16 sq. mm XLPE insulated, PVC outer sheathed, armoured aluminium conductor cable of as per technical specification and direction of EIC.(Make: Polycab/ Gloster) |
| 39 | Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985(Dia) 50mm inner dia HDPE Roll pipes [PE - 63] A. 6 Kg / Sq.Cm. (Working Pressure) 50mm Dia |
| 40 | Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core |
| 41 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a)Depth of excavation not exceeding 1,500 mm. For laying of 50mm inner dia HDPE Roll pipes. |
| 42 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. (xii) 4core 16 sqmm cable. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender