Tender For Additional Electrical Power Points In Various Laboratory Rooms Of Alipurduar Government Engineering And Management College At Chepani In The District Of Alipurduar.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Nov 2026
1 days left
EMD
50000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Additional Electrical Power Points In Various Laboratory Rooms Of Alipurduar Government Engineering And Management College At Chepani In The District Of Alipurduar.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing double door 4 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish inct. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Up to 250A |
| 2 | Supplying and fixing double door 8 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Up to 160A |
| 3 | Supplying and fixing double door Horizontal 8 way ТРN МСВ Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment |
| 4 | Supplying and fixing double door Horizontal 6 way TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish inci. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment |
| 5 | Supplying and fixing double door Horizontal 4 way TPN MCB Distribution board with IP-42/43 protection, concealed In wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment |
| 6 | Supplying and fixing double-door 2+4 way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 7 | Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 8 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy, connection as required 2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC |
| 9 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC Insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy, connection as required 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 10 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC |
| 11 | Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works 20x10mm Size |
| 12 | Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works 25x10mm Size |
| 13 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C-Curve) in SS enclosure fixed on wall and cecessary conection |
| 14 | Supplying and Fixing MCCB SS enclosure with IP. 20/30 profection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutling the wall & mending good the damages to original finish/on flat iron frame incl painting. connection & provision for earthing allachment(L&T) |
| 15 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/enclosure and necessary connection 250 A FP MCCB |
| 16 | 160 A MCCB |
| 17 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 63FP MCB |
| 18 | 63 TP MCB |
| 19 | 32 TP MCB |
| 20 | (6-32) TP MCB |
| 21 | b)out going -(6-32) A SP MCB |
| 22 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by CIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. 5&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 23 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 12 Module |
| 24 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 25 | Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 26 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy connections with PVC Cu wire and earth continuity wire etc |
| 27 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by [IC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 28 | Supply, Transportation, Loading & unloading of following types of 1.1KV grade XLPE 1.1kv grade Al armoured XLPE cable 3.5 CORE 50 sq. mm. |
| 29 | 3.5 CORE 70 sq. mm. |
| 30 | Laying of one No. cableabove 35 sqmm and upto 185 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 31 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: 3.5 CORE 70 sq. mm |
| 32 | 3.5 CORE 50 sq. mm. |
| 33 | Finishing the end of following, XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 3.5 CORE 70 sq. mm |
| 34 | 3.5 CORE 50 sq. mm |
| 35 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to bolts, nuts, washers cable lugs etc. as required and mending good damages Solid GI wire No 8 SWG |
| 36 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 45WG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long Gi bolts, double nuts, double washers incl. S & F 15 men dia Gil pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mis below the ground level as below. By TATA-Medium Gi pipe |
| 37 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 8636 cm x 40 cm deep (belaw Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, Gl reducer including drilling of 46 nos. 12 mm dia holes on the Gl pipe |
| 38 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 39 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolts, nuts, washers, spacing insulators etc. as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender