Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #58027396

Tender For Provision Of Water Scooter Parking Shed Near Jetty Main Gate At Coast Guard Under Ge Haddo, Sri Vijaya Puram

Issued by Statutory Bodies & Commissions/Committees · South Andamans, Andaman And Nicobar Islands
Tender Value
43.30 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
2 days left
EMD
86600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Water Scooter Parking Shed Near Jetty Main Gate At Coast Guard Under Ge Haddo, Sri Vijaya Puram

BOQ

Name of Work:- PROVISION OF WATER SCOOTER PARKING SHED NEAR JETTY MAIN GATE AT COAST GUARD UNDER GE HADDO, SRI VIJAYA PURAM
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out Soft/loose soil, etc complete all as specified.
2Rough excavation not exceeding 1.5 m deep and getting out in hard / dense soil, cutting by chisel or mechanical plant, etc complete all as specified.
3Excavation in trenches for foundation n.exc 1.5 meter wide and n exc. 1.5 meter depth and not exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
4Returning, filling in approved earth including spreading, levelling watering and well ramming in layers n.exc 25cm in foundation in hard/dense soil complete all as specified and directed.
5Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mm above the starting point complete all as specified and directed.
6Material and labour for broken stone or boulders hardcore of gauge n exc 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled/ rammed to a true surface, etc complete all as specified.
7M&L for Hand packing (any thicknes) at back of walls etc with broken stone or boulders and raising (or lowering) to the required level complete all as specified.
8M&L for cement concrete 1:3:6 type C2, using 40mm graded stone aggregate in foundation filling and mass concrete etc, complete all as specified and as directed.
9M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed
10Material and labour reinforced cement concrete Design Mix M-30 (20mm graded agg) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as spd and directed.
11Material and labour reinforced cement concrete Design Mix M-30 (20mm graded agg ) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses etc complete all as spd and directed.
12M&L for Reinforced cement concrete Type B1,1:2:4 using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc all as specified and directed.
13Material and labour for formwork to sides of rough finished flat concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified.
14Material and labour for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified.
15Material and labour for precast cement concret block masonary 1:3:6 type C1 using 20mm graded stone agg with solid blocks, exc 10cm in width and setting in CM 1:6 etc, complete all as specified and as directed.
16M & L for providing 100 mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors complete all as specified and directed.
17M&L for providing PCC 1:2:4 type B2 (using 40mm graded stone agg) as in floor finished, 50 mm thick etc all as specified and directed.
18Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc, completed all as specified and directed.
19Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips etc, complete all as specified and as directed.
20Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 8 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips etc, complete all as specified and as directed.
21Supply and fix roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde E- 250) quality A etc, complete all as specified and as directed.
22Material and labour mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 etc, complete all as specified and as directed.
23Supply and fix mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm etc, complete all as specified and as directed.
24S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, complete all as specified and as directed.
25S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, complete all as specified and directed.
26M&L for Aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering etc fixed with self tapping screws etc, complete all as specified and as directed.
27S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including all necessary fittings etc, complete all as specified and as directed.
28S&F PVC (SWR) bends any radius, 110mm bore etc, complete all as specified and as directed.
29M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement etc, complete all as specified and as directed.
30Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc, complete all as specified and as directed.
31M&L for preparation of new steel surfaces of any description exc 10 cm width or girth when unconnected with other Painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer etc, complete all as specified and as directed.
32M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces.
33All as per item Sl No.32 above, but, for One light/fan point controlled by one modular switch 6 Amps one way complete all as specified and directed.
34All as per item Sl No.32 above, but , for one modular 3 pin 6 Amp socket out let on independent board complete all as specified and directed.
35All as per item Sl No.32 above, but, for one modular 3 pin 6 Amps socket outlet on same Board complete all as specified and directed.
36All as per item Srl No.32 above, but , point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed.
37S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
38S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed.
39S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
40S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16 Amp , universal complete all as specified and directed.
41S & F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete all as specified and as directed.
42Supply and fix medium bay/high bay light 150 watts made of aluminium die cast having IP 65 rating with high efficacy 100 lmns /watt suitable for working on 230 volts 50 Hz supply complete all as specified and as directed.
43Supply & fix Modular Box With 20A DP MCB \\"C' Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed. Make:- Anchor (Roma) model no 98492 or equivalent to Havells/L&T
44S & F 30/35 watts LED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessary fixing arrangements including brackets 32/40mm for mounting as per site requirements all as specified and directed by Engr In charge.
45S & F Sub main wiring with PVC insulated FRLSH cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/ surface conduit (ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLS copper conductor single core 4.0 sq mm for earth continuity all as directed. Note : 3 length of cable and one length casing & caping shall be measured and paid for one length .
46S&F, installation and testing of electric winch system, ramp type, 12 V DC, minimum 2500 lbs (1134 kg) pulling/line capacity, complete with suitably rated electric motor and reduction gear mechanism, durable steel wire rope/cable, drum, mounting plate/bracket and necessary electrical connections, controls, fasteners and accessories. The winch shall be suitable for outdoor/ramp application, corrosion/weather resistant and capable of safe and smooth pulling operation, complete all as specified and directed by Engineer-in-Charge.
47S & F Triple pole and neutral sheet steel powder coated Distribution board IP -54 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door TP&N DB system 04 ways,and making good to the distrubed surface /walls complete all as specified and as directed.
48Supplying & fixing MCB TPN 63 Amps having current rating 10 KA complete all as specified and directed .
49Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.Note:- All copper conductors should be connected with MCCB/ MCB alongwith copper reducer terminals of suitable size duly crimpled.”
50Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and as directed.
51Supply and laying in trenches or in cable dusts or clamping on wall DWC HDPE pipe of size 50 mm (OD) x 38 mm (ID) along with connected accessories like cpuplers,bend,end caps etc. for LT cable protection all as specified and directed.
52Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / pole and getting out in the hard/dense soil complete all as specified and as directed.
53M&L for Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.00 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32 mm x 6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
54Supply and fix earth continuity conductor 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles complete all as specified and as directed by Engineer-in-charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58027396
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.30 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Water Scooter Parking Shed Near Jetty Main Gate At Coast Guard Under Ge Haddo, Sri Vijaya Puram
Basic Detail
Tender No 8370/E8
Bidding Type Tender
Location
City South Andamans
State Andaman And Nicobar Islands
Key Dates
Publish Date 14 Oct 2026
Submission Date 03 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 43.30 Lakhs
Tender Fee 500
EMD 86600
Exemption Available
Document List
26516027-390b-4f4e-89e9-2a9995e9c852.html
8370Tender.pdf
BOQ_890285.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

26516027-390b-4f4e-89e9-2a9995e9c852.html

pdf

8370Tender.pdf

xls

BOQ_890285.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender