Tender for Advertized Rate List/bill of q Uantity for Completion of Balance Work of School Building at gms Seelo,gms Zaloora Zone Dangerpora
Tender Value
1.08 Crore
Estimated cost
Bid Submission
30 Oct 2026
7 days left
EMD
2.16 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Advertized Rate List/bill of q Uantity for Completion of Balance Work of School Building at gms Seelo,gms Zaloora Zone Dangerpora
BOQ
| Sl. No. | Item Description |
| 1 | GMS Seelo: Earth work in excavation in all kinds of soil by Manual/mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed by site Engineer incld.cutting of trees, removal of tree stumps and dewatering of trenches during execution of work.. |
| 2 | Supply and filling of dry stone soling in foundation trenches tightly hand packed with hand ramming, dressing ,watering incld. carriage of material from source to site of work complete |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand: 8 grade stone aggregate 40mm nominal size) including all carriages. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level 1:2:4(1 Cement: 2 coarse sand:4grade stone aggregate 20mm nominal size) including all carriages. |
| 5 | Centering and shuttering including strutting propping etc. and removal of form for foundation, footings basses of columns etc . For mass concrete including all carriages. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. including all carriages. |
| 7 | Providing wood work in frames of doors, windows, clesrestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) kd Wood including all carriages. |
| 8 | Providing and fixing 35 mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. First class kail wood including all carriages. |
| 9 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type with carriage. |
| 10 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows,clerestory windows, all complete with . 4.0mm thick glass panes with carriage. |
| 11 | Providing and fixing of 40X5mm flat iron hold fast 40 cm long including fixing to frame with 10mm dia bolts, nuts and wooden plugs and embeddings in cement concrete block 30X10X15 cm 1:3:6 mix ( 1 Cement : 3 Coarse sand :6 graded stone aggregate 20 mm nominal size) including all carriages. |
| 12 | Hardware Items:Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.T.Bolts 100 mm incld all carriages |
| 13 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.T.Bolts 150 mm incld all carriages |
| 14 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.Handles 125 mm incld all carriages |
| 15 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.Handles 150 mm incld all carriages |
| 16 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete with carriage. |
| 17 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.Almunium W indow Hooks incld all carriages |
| 18 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping groundwithin 50 meters lead. |
| 19 | 12mm Cement plaster of mix in 1 : 6 ( 1 cement : 6 coarse sand) including all carriages. |
| 20 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick with carriage complete. |
| 21 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm), including all carriages. |
| 22 | Finishing with Deluxe multi surface paint system for interiors andexteriors using primer as per manufacturers’ specifications.Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm with carriage. |
| 23 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all carriages. |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work including all carriages. |
| 25 | Applying priming coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works including all carriages. |
| 26 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) with carriage. |
| 27 | Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointedwith cement mortar 1:3 (1cement: 3 fine sand) and curing complete with carriage. |
| 28 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, including all carriages. |
| 29 | Providing Color coated Hi RIB GS Sheet Roofing fixed Polymer Coated Jor L Hooks Bolts AND NUTS 8 mm dia with Bitumen and GI Implet Washers upto A Pitch of 60 Degrees Excl of Purlins ,Rafters ,Trusses.0.50 MM Thick including all other fixtures complete Job with carriage. |
| 30 | Providing color ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.0.50 mm thick with zinc coating not less than 275 gram/m2 with carriage. |
| 31 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate with carriage. |
| 32 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) with carriage. |
| 33 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level uoto floor five level including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand ) including all carriages. |
| 34 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area of 3 sqm. and below. |
| 35 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. |
| 36 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge.Second class Kail wood.35mm with carriage. |
| 37 | Carriage of material By Mechanical transport Average Lead 25 Km.Stone Aggregrate. |
| 38 | Seating Arrangement:Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, including all carriages. |
| 39 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws.2nd class kail wood with carriage. |
| 40 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all carriages. |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work including all carriages. |
| 42 | GMS Zaloora: Earth work in excavation in all kinds of soil by Manual/mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed by site Engineer incld.cutting of trees, removal of tree stumps and dewatering of trenches during execution of work.. |
| 43 | Supply and filling of dry stone soling in foundation trenches tightly hand packed with hand ramming, dressing ,watering incld. carriage of material from source to site of work complete |
| 44 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand: 8 grade stone aggregate 40mm nominal size) including all carriages. |
| 45 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work up to plinth level 1:2:4(1 Cement: 2 coarse sand:4grade stone aggregate 20mm nominal size) including all carriages. |
| 46 | Centering and shuttering including strutting propping etc. and removal of form for foundation, footings basses of columns etc . For mass concrete including all carriages. |
| 47 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. including all carriages. |
| 48 | Providing wood work in frames of doors, windows, clesrestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) kd Wood including all carriages. |
| 49 | Providing and fixing 35 mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. First class kail wood including all carriages. |
| 50 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type with carriage. |
| 51 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows,clerestory windows, all complete with . 4.0mm thick glass panes with carriage. |
| 52 | Providing and fixing of 40X5mm flat iron hold fast 40 cm long including fixing to frame with 10mm dia bolts, nuts and wooden plugs and embeddings in cement concrete block 30X10X15 cm 1:3:6 mix ( 1 Cement : 3 Coarse sand :6 graded stone aggregate 20 mm nominal size) including all carriages. |
| 53 | Hardware Items:Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.T.Bolts 100 mm incld all carriages |
| 54 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.T.Bolts 150 mm incld all carriages |
| 55 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.Handles 125 mm incld all carriages |
| 56 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.Handles 150 mm incld all carriages |
| 57 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete with carriage. |
| 58 | Providing and fixing of Hardware Items of ISI Marked of Standard Quality and Make.Almunium W indow Hooks incld all carriages |
| 59 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping groundwithin 50 meters lead. |
| 60 | 12mm Cement plaster of mix in 1 : 6 ( 1 cement : 6 coarse sand) including all carriages. |
| 61 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick with carriage complete. |
| 62 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm), including all carriages. |
| 63 | Finishing with Deluxe multi surface paint system for interiors andexteriors using primer as per manufacturers’ specifications.Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm with carriage. |
| 64 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all carriages. |
| 65 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work including all carriages. |
| 66 | Applying priming coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works including all carriages. |
| 67 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 or richer mix (i/c equivalent design mix) with carriage. |
| 68 | Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointedwith cement mortar 1:3 (1cement: 3 fine sand) and curing complete with carriage. |
| 69 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, including all carriages. |
| 70 | Providing Color coated Hi RIB GS Sheet Roofing fixed Polymer Coated Jor L Hooks Bolts AND NUTS 8 mm dia with Bitumen and GI Implet Washers upto A Pitch of 60 Degrees Excl of Purlins ,Rafters ,Trusses.0.50 MM Thick including all other fixtures complete Job with carriage. |
| 71 | Providing color ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.0.50 mm thick with zinc coating not less than 275 gram/m2 with carriage. |
| 72 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate with carriage. |
| 73 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) with carriage. |
| 74 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area of 3 sqm. and below. |
| 75 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. |
| 76 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge.Second class Kail wood.35mm with carriage. |
| 77 | Carriage of material By Mechanical transport Average Lead 25 Km.Stone Aggregrate. |
| 78 | Saeting Arrangement:Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, including all carriages. |
| 79 | Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws.2nd class kail wood with carriage. |
| 80 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all carriages. |
| 81 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work including all carriages. |
| 82 | Electrification for GMS Seelo:Wiring for light point / exhaust fan point/bell point with (P+N) 3X1.5 sq.mm FRLS-H PVC insulated copper conductor single core cable in surface / recessed Conduits , with 6Amp .Modular switch, Modular plate, cover in front and suitable GI box of approved quality and make ISO/IEC/BIS Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. excluding cost of Conduits(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage. |
| 83 | Supplying and fixing of Two module Stepped type Electronic Fan Regulator on the existing Modular Plate etc as required ISO/IEC certified of Havells /Legrand/Anchor/Schneider/ABB/Eq Make & Shall be approved before execution of work by SDO. |
| 84 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PV C Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit along with 1 x 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. With . 1NO. 16Amp .Modular switch, Modular 1NO.3-PIN . 16 Amp. Socket , Modular plate, cover and suitable GI box etc as required (wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) complete excluding cost of Conduits incld carriage. |
| 85 | Supply and fixing of Suitable size GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 6 Pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular Switch ,connections etc as required ISO/IEC certified /Legrand/Anchor Roma plus/Scheider/ABB/Eq Make & Shall be approved before execution of of work by SDO. |
| 86 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x2.5sq.mm +1x2.5 sqmm earth wire. |
| 87 | Supply and fixing of Suitable Size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos.3 pin 5/6 A modular socket poutlet and 2 nos.5/6 A Modular Switch ,connection etc as required (For Lighting Plugs to be used in non residentail buildings),ISO/IEC certified Hevells /Legrand /Anchor roma Plus/schneider/ABB/Eq.Make & shall be approved before executon of work. |
| 88 | Supply and fixing of Testing and Commissioning of 6 Amp to 32 Amp Rating,240,*C* curve 10 k, Miniature circuit Breaker suitable for inductive load of following poles in existing MCB.DB complete with connection.(L&T /Siemens /Legrand/Havells/ABB/Eq Makr including all carriages. |
| 89 | Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve 10 k, Miniature circuit breaker (MCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. incld carriage.63Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens.40Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens |
| 90 | 63 Amp |
| 91 | 32Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens |
| 92 | Supply and fixing of MCB way 6 -way (4+18) ,horizontal typed sheet steel,double Door Distribution Board,TPN 240 V /415 V on surface recess complete with tinned copper bus bar,neutral bus bar ,earth bar ,Din bar ,interconnection,powder painted including earthing erc as required (L& /Siemens/Legrand/Schneider/ABB/Eq make) including all carriages. |
| 93 | Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havel's or Wipro or Jaguar orBajaj or H.G LUKEER make [Various Locations ] incld carriage. |
| 94 | Providing and fixing of 1k08 IP-66 Protected High Power LED 50 Watt Flood Light system with single piece Pressure diecast Almunium housing, toughened glass diffuser with suitable lenses on LED to achieve various beams angles of High Power LED 3 to 5 watt each intergrated potted driver as a unique BIS R number having effiency more than 85% and in compliance to BIS certified and trade mark certificate. The System Level Luminaire efficiency >=15 Im/wt.LED driver input voltage AC 120 to 270 V AC With High voltage cutt off @>=3000 V AC and Auto resulting safety.Power Factor >0.95,THD(l) <10%,driver current <=750 ma,driver should be phase to phas protection of 440 v for 4 Hrs. Electrical Connector,Surge Protection Minin.>=4kv internal and 10 Kv external but inside driver compartment .System life of 50000 Burning hours with 70% of initial Lumens maintained,CRI>70 and CCT 5700 K,355 k.Manufactirers word Mark /Name Engraved/Embossing /screen Printing on die cast housing to allow traceability/authenticity.Fixtures Shall be IS 10322 complianced.OEM must haave its own in house NABAL lab setup for all testing facilities for LED fixtures (LM79/LM80) certificte /report with liable Warrenty of product / accessories from OEM shall be submitted.All as per pre approved by site Engineer.For additional technical parameters of product /work ,refer BSR -High Power LED Flood Light Minimium Lumen output 6200 IM of Havells /crompton /Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The Job further includes replacement warrenty of fixtures (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successfull commissioning /handling over of site to intending Depertment. |
| 95 | Supply ,Installation,Testing and Commissioning of Decorative 1200 mm Sweep Ceiling Fan with 3 No.Almunium Blades ,30 Cm long down rod, 2 nos.Canopies,Shackle kit, Power factor not less than 0.9, service value including safety Pin,nut bolts,washers ,temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz and including Iron Hook complete.USHA striker /Havells Oyster metalic /Crompton Aura/Equivalent make as directed by Site Engineer. |
| 96 | Supply, Installation/Connecting and Commissioning of 50 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminium Cable. Make of Havells/Polycab/Eq. Make with required size of thimbles duly crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly Ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench. (Material to be approved before execution) |
| 97 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel, duly painted with powder coated paint, dust protected, earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells, L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/L&T/Legrand/Schneider Make.(1) Normal Incoming:a) 250 Amp, 2-Pole, 16kA A.C. CURVE MCCB with extended terminals. Havells/L&T/Legrand/Schneider Make as approved = 01 No.b) 250 Amps TPN All Bus Bar Set = 01 Set, Digital Voltmeter, Ammeter, C.T Coils with Selector Switch & Phase Indicator Set.Outgoing:(1) Normal outgoing for Heating/AC Lighting/Inverter etc. load(a) 63-Amp DP MCB = 02 No. for Heating Sub-main.b) 40-Amp DP MCB = 02 No. for Lighting/Machine Sub-main.(c) 32-Amp DP MCB = 02 No. for Inverter Circuits |
| 98 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x10 sq.mm +1x6 sqmm earth wire. |
| 99 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x6 sq.mm +1x6 sqmm earth wire. |
| 100 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x4 sq.mm +1x4 sqmm earth wire. |
| 101 | Supply/Installation/Testing/Commissioning of Inverter 3750VA/24 V Pure Sinewave Inverter With Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 03 No. of 200Ah, 12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminous/EXIDE/AMRON/Eq. Make |
| 102 | Electrification for GMS Zaloora:Wiring for light point / exhaust fan point/bell point with (P+N) 3X1.5 sq.mm FRLS-H PVC insulated copper conductor single core cable in surface / recessed Conduits , with 6Amp .Modular switch, Modular plate, cover in front and suitable GI box of approved quality and make ISO/IEC/BIS Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. excluding cost of Conduits(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage. |
| 103 | Supplying and fixing of Two module Stepped type Electronic Fan Regulator on the existing Modular Plate etc as required ISO/IEC certified of Havells /Legrand/Anchor/Schneider/ABB/Eq Make & Shall be approved before execution of work by SDO. |
| 104 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PV C Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit along with 1 x 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop Earthing of approved quality and ISI marked as required. With . 1NO. 16Amp .Modular switch, Modular 1NO.3-PIN . 16 Amp. Socket , Modular plate, cover and suitable GI box etc as required (wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) complete excluding cost of Conduits incld carriage. |
| 105 | Supply and fixing of Suitable size GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 6 Pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular Switch ,connections etc as required ISO/IEC certified /Legrand/Anchor Roma plus/Scheider/ABB/Eq Make & Shall be approved before execution of of work by SDO. |
| 106 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x2.5sq.mm +1x2.5 sqmm earth wire. |
| 107 | Supply and fixing of Suitable Size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos.3 pin 5/6 A modular socket poutlet and 2 nos.5/6 A Modular Switch ,connection etc as required (For Lighting Plugs to be used in non residentail buildings),ISO/IEC certified Hevells /Legrand /Anchor roma Plus/schneider/ABB/Eq.Make & shall be approved before executon of work. |
| 108 | Supply and fixing of Testing and Commissioning of 6 Amp to 32 Amp Rating,240,*C* curve 10 k, Miniature circuit Breaker suitable for inductive load of following poles in existing MCB.DB complete with connection.(L&T /Siemens /Legrand/Havells/ABB/Eq Makr including all carriages. |
| 109 | Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve 10 k, Miniature circuit breaker (MCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. incld carriage.63Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens.40Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens |
| 110 | 63 Amp |
| 111 | 32Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens |
| 112 | Supply and fixing of MCB way 6 -way (4+18) ,horizontal typed sheet steel,double Door Distribution Board,TPN 240 V /415 V on surface recess complete with tinned copper bus bar,neutral bus bar ,earth bar ,Din bar ,interconnection,powder painted including earthing erc as required (L& /Siemens/Legrand/Schneider/ABB/Eq make) including all carriages. |
| 113 | Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havel's or Wipro or Jaguar orBajaj or H.G LUKEER make [Various Locations ] incld carriage. |
| 114 | Providing and fixing of 1k08 IP-66 Protected High Power LED 50 Watt Flood Light system with single piece Pressure diecast Almunium housing, toughened glass diffuser with suitable lenses on LED to achieve various beams angles of High Power LED 3 to 5 watt each intergrated potted driver as a unique BIS R number having effiency more than 85% and in compliance to BIS certified and trade mark certificate. The System Level Luminaire efficiency >=15 Im/wt.LED driver input voltage AC 120 to 270 V AC With High voltage cutt off @>=3000 V AC and Auto resulting safety.Power Factor >0.95,THD(l) <10%,driver current <=750 ma,driver should be phase to phas protection of 440 v for 4 Hrs. Electrical Connector,Surge Protection Minin.>=4kv internal and 10 Kv external but inside driver compartment .System life of 50000 Burning hours with 70% of initial Lumens maintained,CRI>70 and CCT 5700 K,355 k.Manufactirers word Mark /Name Engraved/Embossing /screen Printing on die cast housing to allow traceability/authenticity.Fixtures Shall be IS 10322 complianced.OEM must haave its own in house NABAL lab setup for all testing facilities for LED fixtures (LM79/LM80) certificte /report with liable Warrenty of product / accessories from OEM shall be submitted.All as per pre approved by site Engineer.For additional technical parameters of product /work ,refer BSR -High Power LED Flood Light Minimium Lumen output 6200 IM of Havells /crompton /Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The Job further includes replacement warrenty of fixtures (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successfull commissioning /handling over of site to intending Depertment. |
| 115 | Supply ,Installation,Testing and Commissioning of Decorative 1200 mm Sweep Ceiling Fan with 3 No.Almunium Blades ,30 Cm long down rod, 2 nos.Canopies,Shackle kit, Power factor not less than 0.9, service value including safety Pin,nut bolts,washers ,temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz and including Iron Hook complete.USHA striker /Havells Oyster metalic /Crompton Aura/Equivalent make as directed by Site Engineer. |
| 116 | Supply, Installation/Connecting and Commissioning of 50 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminium Cable. Make of Havells/Polycab/Eq. Make with required size of thimbles duly crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly Ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench. (Material to be approved before execution) |
| 117 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel, duly painted with powder coated paint, dust protected, earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells, L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/L&T/Legrand/Schneider Make.(1) Normal Incoming:a) 250 Amp, 2-Pole, 16kA A.C. CURVE MCCB with extended terminals. Havells/L&T/Legrand/Schneider Make as approved = 01 No.b) 250 Amps TPN All Bus Bar Set = 01 Set, Digital Voltmeter, Ammeter, C.T Coils with Selector Switch & Phase Indicator Set.Outgoing:(1) Normal outgoing for Heating/AC Lighting/Inverter etc. load(a) 63-Amp DP MCB = 02 No. for Heating Sub-main.b) 40-Amp DP MCB = 02 No. for Lighting/Machine Sub-main.(c) 32-Amp DP MCB = 02 No. for Inverter Circuits |
| 118 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x10 sq.mm +1x6 sqmm earth wire. |
| 119 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x6 sq.mm +1x6 sqmm earth wire. |
| 120 | Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. [including . Conduites] .(wire shall be approved before execution of wok by SITE In-charge Engineer strictly incld carriage.2x4 sq.mm +1x4 sqmm earth wire. |
| 121 | Supply/Installation/Testing/Commissioning of Inverter 3750VA/24 V Pure Sinewave Inverter With Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 03 No. of 200Ah, 12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminous/EXIDE/AMRON/Eq. Make Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender