Tender For Addition/ Alteration To Mt Pool At Coast Guard Under Ge Haddo, Sri Vijaya Puram
Tender Value
43 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
19 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition/ Alteration To Mt Pool At Coast Guard Under Ge Haddo, Sri Vijaya Puram
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided etc, complete all as specified and as directed. |
| 2 | Demolition of (unreinforced) cement concerete in ground floors and paving not exceeding 15 cm thickness (below or above GL) etc, complete all as specified and as directed. |
| 3 | M&L for cement concrete 1:4:8 type D2, using 40mm graded stone aggregate in foundation filling and mass concrete etc, complete all as specified and as directed. |
| 4 | M&L PCC 1:2:4 type B2 (40mm grade stone agg) as in cement concrete in surface channel and drain etc, complete all as specified and as directed. |
| 5 | M&L precast reinforced cement concrete 1:2:4 (type B1) as in cover slab and set in cement morter (1:6), etc complete all as specified and as directed |
| 6 | Material and labour for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding15 cm thick, watered and rammed to a true surface, etc complete all as specified. |
| 7 | M&L for reinforced cement concrete flooring 1:2:4 (type B1) (using 20mm graded stone agg), 100 mm thick etc all as specified and directed. Note : Reinforcement measured separately. |
| 8 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc, complete all as specified and as directed. |
| 9 | Material and labour for precast cement concret block masonary 1:3:6 type C1 using 20mm graded stone agg with solid blocks, exc 10cm in width and setting in CM 1:6 etc, complete all as specified and as directed. |
| 10 | Excavating in post holes each n exc 0.5 cum, getting out, in hard /dense soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing surfaces soil to distance nexc 50 m and making good surfaces etc, complete all as specified and as directed. |
| 11 | Excavation in trenches for foundation n.exc 1.5 meter wide and n exc. 1.5 meter depth and not exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 12 | Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mm above the starting point complete all as specified and directed. |
| 13 | M&L PCC 1:2:4 type B2 (using 40mm graded agg) as in foundation filling and mass concrete etc, complete all as specified and as directed. |
| 14 | M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone agg) as in sub-base of floor, 100mm thick etc, complete all as specified and as directed. |
| 15 | Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips etc, complete all as specified and as directed. |
| 16 | Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 8 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips etc, complete all as specified and as directed. |
| 17 | Dismantling of mild steel work of any description and in any position etc, complete all as specified and as directed. |
| 18 | Supply and fix roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde E- 250) quality A etc, complete all as specified and as directed. |
| 19 | Material and labour mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 etc, complete all as specified and as directed. |
| 20 | Supply and fix mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm etc, complete all as specified and as directed. |
| 21 | Supply and fix framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc, complete all as specified and as directed. |
| 22 | S & F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured),etc complete all as spd and directed. |
| 23 | S&F in repairs 600mm dia concertina coil fencing conforming to IS 4454 Part-I, made out of 2.6mm (+ or - 2%) dia of steel core wire galvanised and with anti rust coating (Black colour), with coils not less than 51 turns for an effective stretched length of 6m with 2 handles, duly placed on existing supports over security/ compound walls and tied with 2mm dia binding wire and the spikes at the ends of coils embedded into PCC coping all as specified and as directed. Note: PCC coping shall be measured and paid separately. |
| 24 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, etc all as specified and directed. |
| 25 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including or similar pattern roof coverings etc, complete all as specified and as directed. |
| 26 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, complete all as specified and as directed. |
| 27 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, complete all as specified and directed. |
| 28 | M&L for Aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0micron fixed over frame of aluminium tabular section 50x25mmx 2.0mm thick, having panels not exc 1200x1200mm with necessary silicon filling, in approved pattern as in column, beam, wall at any height with necessary scafoldings etc complete as specified and as directed. |
| 29 | M&L for Aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering etc fixed with self tapping screws etc, complete all as specified and as directed. |
| 30 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including all necessary fittings etc, complete all as specified and as directed. |
| 31 | S&F PVC (SWR) bends any radius, 110mm bore etc, complete all as specified and as directed. |
| 32 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement etc, complete all as specified and as directed. |
| 33 | M&L for rendering 5mm thick in cement mortar 1: 4 mixed with water proofing compound over 10mm thick backing coat in cement mortar 1:6 on fair faces of brick work or PCC block masonry of concrete surfaces finished even and smooth without using extra cement etc, complete all as specified and as directed.Note: Water proofing compound shall be measured and paid separately. |
| 34 | Supplied only integral waterproofing compound etc, complete all as specified and as directed. |
| 35 | Material and labour for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair etc, complete all as specified and as directed. |
| 36 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc, complete all as specified and as directed. |
| 37 | Material & Labour for complete removal of existing treatment on old walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc, complete all as specified and as directed. |
| 38 | Material and labour for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces etc, complete all as specified and as directed. |
| 39 | M&L for preparation of new steel surfaces of any description exc 10 cm width or girth when unconnected with other Painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer etc, complete all as specified and as directed. |
| 40 | M & L for preparation of old steel surfaces and apply one coat of synthetic enamel paint exc 10cm in width or girth etc, complete all as specified and as directed. |
| 41 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. etc, completed all as specified and directed. |
| 42 | Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed. |
| 43 | Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 44 | Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed. |
| 45 | M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 46 | All as per item Sl No.45 above, but, for One light/fan point controlled by one modular switch 6 Amps one way complete all as specified and directed. |
| 47 | All as per item Sl No.45 above, but , for one modular 3 pin 6 Amp socket out let on independent board complete all as specified and directed. |
| 48 | All as per item Sl No.45 above, but, for one modular 3 pin 6 Amps socket outlet on same Board complete all as specified and directed. |
| 49 | All as per item Srl No.45 above, but , point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed. |
| 50 | S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 51 | S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed. |
| 52 | S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 53 | S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16 Amp , universal complete all as specified and directed. |
| 54 | S & F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete all as specified and as directed. |
| 55 | Supply & fix Modular Box With 32A TP MCB \\"C' Type, Metal Enclosure & Unbreakable Heavy Duty With ISI three pin and earth Plug with socket complete with one triple pole MCB, 240 volts AC complete all as specified and directed. |
| 56 | Supply and fix exhaust fan 300 mm sweep suitable for working on 230 volts 50 hz supply including taking down old unsv one |
| 57 | Supply and fix Heavy duty industrial wall mounted fan 450 mm sweep suitable for working on 230 volts 50 hz supply including taking down old unsv one |
| 58 | Supply and fixing LED lights fitting 1x 22W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge |
| 59 | Supply and fix HIGH BAY LED lights hanging / ceiling mounting type 120 watts fitting with PC diffuser with surge protection with suitable hanging arrangements complete all as specified and directed. |
| 60 | S & F GI brackets of GI pipe light grade of size 32 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 61 | S & F 30/35 watts LED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessary fixing arrangements as per site requirements class all as specified and directed by Engr In charge. |
| 62 | Supply and fix LED flood light 150 watts IP 66 protection single phase 50 Hz with all accessories complete all as specified and directed by Engineer-in-charge |
| 63 | M&L for Sub main wiring complete with four runs (3P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including PVC casing caping and accessories fixed in concealed or on surface of wall/ceiling/roof/ floor complete all as specified and as directed.NOTE: Four runs (3P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. |
| 64 | M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed.NOTE: Four runs (3P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length. |
| 65 | M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 25 mm wide rigid non-metallic PVC casing and capping and its accessories on surface of wall/ceiling/roof/ floor complete all as specified and as directed. |
| 66 | Supply and fix PVC surface conduit 32 mm dia (ISI marked) incl all specials/ accessories for passing of cables all as specified and as directed by Engineer-in-Charge |
| 67 | S & F DB VTPN sheet metal enclosure double door IP 43 protection, door earth suitable for incoming upto MCCB 100 Amps/125 Amps & outgoing MCB TP / SP. Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete including taking down old unsv DB of any type /rating and making good to the distrubed surface /walls all as specified and directed. |
| 68 | S & F single pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 08 ways,and making good to the distrubed surface /walls all as specified and directed. |
| 69 | S & F in replacement of MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminalscomplete all as specified and as directed. |
| 70 | Supplying & fixing MCB SPN 32/40 Amps (`C’ series) having current rating 10 KA complete all as specified and directed . |
| 71 | Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed. |
| 72 | Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender