Tender For Cleaning, Replacement And Repairs Of Septic Tanks, Manholes And Sewage Lines, Repair/Maint Work To Attend Day To Day Complaints And Repairs To Leakage, Seepage Including Roof Treatment And Internal Water Supply For Permanent And Temporary
Tender Overview
Project Description
Tender for Cleaning, Replacement And Repairs Of Septic Tanks, Manholes And Sewage Lines, Repair/Maint Work To Attend Day To Day Complaints And Repairs To Leakage, Seepage Including Roof Treatment And Internal Water Supply For Permanent And Temporary Bldgs At Md/Otm Accn In Ancom, Jal Vihar, Maneskshaw Enclave, Mes Accns, Emergency Block, Dweepika, Ge Office And Fmsd Of Age B/R-I Under Ge Haddo, Sri Vijaya Puram
BOQ
| Sl. No. | Item Description |
| 1 | Removing and Cleaning out blockage from traps of bathroom / kitchen sink / wash basin / urinal point and gully traps of any description and in any position by removing sand / sludge / silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewerage system functional to the entire satisfaction complete all as specified and as directed |
| 2 | Taking out carefully the cover slab of gulley traps of any size, shape, depth and cleaning the block by removing the scum / sludge / any material and removing to a distance exc 250m and n. exc 500m and cleaning with fresh water incl placing the cover slab / grating in position complete all as specified and as directed |
| 3 | Cleaning sewage line of any dia using passing rubber ball through line to ensure all blockage perfectly clear or split bamboo with a gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage line through manhole/gully trap for clear flow of sewage in sewage pipe line complete all as specified and directed |
| 4 | Bailing out water from manholes of depth of manhole Not exc 0.60m, manually or mechanically & taking out sludge/foreign material, disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out complete including taking out manhole covers and placing back manhole covers in position on manholes of any size complete all as directed. |
| 5 | Bailing out water from manholes of depth of manhole Exc 0.60m & N.exc 1.00m, manually or mechanically & taking out sludge/foreign material, disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out complete including taking out manhole covers and placing back manhole covers in position on manholes of any size complete all as directed. |
| 6 | Bailing out water from manholes of depth of manhole Exc 1.00m & N.exc 1.50m, manually or mechanically & taking out sludge/foreign material, disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out complete including taking out manhole covers and placing back manhole covers in position on manholes of any size complete all as directed. |
| 7 | Removing and Cleaning out blockage of water closet including WC trap of any description and in any position by removing sand / sludge / silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewerage system functional to the entire satisfaction complete all as specified and as directed |
| 8 | Clearing carefully the blockages in sewage lines upto 150mm dia by passing rubber ball through line to ensure all blockage perfectly clear or split bamboo with a gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage line through manhole/gully trap for clear flow of sewage in sewage pipe line all as directed by Engineer-in-Charge. |
| 9 | Cleaning of septic tanks/filter beds completely by emptying the liquid/semi solid foul contents any depth completely cleaning the inlet/outlet etc including disposal of soil/sludge by pumping mechanically into covered tank of mounted truck and disposing the same to a distance exc10.00 km complete all as directed. |
| 10 | Cutting down Plants/trees of girth not exc 15cm from roof tops/sides, external walls of building, chajja wall junctions, juctions of rain water / CI / soil waste / vent puipes including taking out roots entrered into the wall / slab surfaces,then spraying the affected area with solution of 25ml Glyphosphate (4% content) diluted with 1 litre of water or as per manufacturer's instructions and making good the surfaces using PCC (1:2:4), type B0 or cement mortar 1:3, with neccesary scaffolding / stagging etc, upto any height from ground level, all as specified and as directed. |
| 11 | Cleaning away all grass vegetation, saplings, shrubs, bush wood, undergrowth, roots and trees not exc 30 cm girth and removing rubbish upto a distance of 50 m complete all as directed. |
| 12 | Labour only clearing of air lock in toilets/ bath and kitchen but excluding fittings etc complete all as specified and directed. |
| 13 | NOTE: The item of BOQ shall be executed in high rise building. The contractor shall arrange necessary scaffolding/ shoring, water pressure jet pump and other safety measures to be undertaken including insurance cover for the workers engaged by him during the execution of work. The rate quoted by the contractor for the above items shall be inclusive of the above provisions . Nothing extra on this account is admissible. |
| 14 | Making arrangement of scaffolding in the shafts height upto 10 meter, cutting holes around the bends, tees, junctions of any description in the leakage/seepage and making good the cut portion with cement mortar 1:3 or PCC 1:2:4 (using 12.5mm graded stone aggregate) including two coats of acrylic emulsion antifungal paint with primer complete all as specified and as directed. |
| 15 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed. |
| 16 | Excavation in trenches n. exc 1.5m wide and exc 1.5m but n. exc 3m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed. |
| 17 | M&L for returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed. |
| 18 | M&L for removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed |
| 19 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed |
| 20 | M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed |
| 21 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole including necessary formwork complete all as specified and directed |
| 22 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed. |
| 23 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 all as specified |
| 24 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 25 | M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified |
| 26 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed |
| 27 | Providing and applying plaster of paris putty of 1 mm thickness over old plastered surface to prepare the surface even and smooth of wall complete all as specified and directed by Engg in charge |
| 28 | M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface even and smooth without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid separately) |
| 29 | Supply only liquid water proofing compound |
| 30 | M&L for preparation of old plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 31 | M&L for preparation old plastered surface of wall and applying one coats of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over existing painted surfaces etc complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard or equivalent).Note: Rate quoted shall be deemed to include scafolding upto 12m height or as per the actual site requirements |
| 32 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed |
| 33 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 34 | M&L for reinforced precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, drain cover, cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary form work, set in CM 1:4 complete all as specified and directed (Note : Reinforcement shall be measured and paid for separately) |
| 35 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 36 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 37 | Demolition and breaking up 150mm dia (Salt glazed ware, AC or reinforced concrete) pipe jointed in cement mortar and disposed off the premises complete all as specified and directed |
| 38 | S&F PVC (SWR) pipe 150mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 39 | M&L for concrete bed in PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipe as 100mm and width of bed as 450mm to sewage pipes of 150mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed |
| 40 | Material and labour for 160 mm dia UGD Sewage pipe, single socketed ,in any length jointed in CM 1:3 laid in trenches complete with collar inclding demolition and breaking up PCC and existing PVC drain pipes jointed in cement mortar and taking out of trenches. and taken as credit complete all as specified and as directed. Note :Make of PVC UDG Sewage pipe : Prayag/ Finolex/Supreme/Prince/Astral (ISI MARKED) |
| 41 | S&F PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 42 | M&L for concrete bed in PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipe as 100mm and width of bed as 410mm to sewage pipes of 110mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed |
| 43 | M&L for cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and directed |
| 44 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed |
| 45 | S&F PVC (SWR) pipe 110mm bore, single socketed, in any length including bends, socket etc with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed |
| 46 | S&F PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 47 | S&F in repair PVC (SWR) 110mm dia bend of any radius with access door and jointed with approved adhesive complete all as specified and directed |
| 48 | S&F in repair PVC (SWR) vent cowl 110mm dia jointed with approved adhesive complete all as specified and directed |
| 49 | S&F PVC (SWR) pipe 75mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive fixed to walls complete all as specified and directed |
| 50 | S&F PVC (SWR) pipe 75mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive laid in trenches or in floors complete all as specified and directed |
| 51 | S&F in repair PVC (SWR) bend 75mm dia with access door, any radius as required and jointed with approved adhesive complete all as specified and directed |
| 52 | S&F in repair 75mm outlet dia PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe complete all as directed |
| 53 | Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed |
| 54 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed |
| 55 | S&F for chequered cement concrete tiles 30cmx30cmx25mm thick set jointed with grey cement and pigment and pointed in neat cement slurry over and including 20 mm thick screed bed in CM(1:6), etc complete all as specified and as directed. |
| 56 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 57 | S&F for Heavy Duty Ceramic Parking tiles 30cmx30cmx8-10mm thick set jointed with grey cement and pigment and pointed in neat cement slurry over and including 20 mm thick screed bed in CM(1:6) etc all as specified and as directed. |
| 58 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, padding, sunken, coping portion rounded chamfered on edge complete all as specified and directed |
| 59 | Disconnecting existing tanks of capacity 500 litre to 1000 litre from water supply conections, setting aside (or lowering if required) for repairs, cleaning, etc. and rehoisting if required reconnecting and re-fixing in position etc, complete all as specified and directed. |
| 60 | M & L for self adhesive heavy duty bitumen based water proofing tape reinforced with polyster film below aluminium film having 95mm width and minimum thickness of 1.5mm laid on roof surfaces by forced application including cleaning of surfaces complete all as specified |
| 61 | M & L for self adhesive heavy duty bitumen based water proofing film reinforced with PVC film having minimum thickness of 2 to 4 mm laid on roof surfaces by forced application including cleaning of surfaces complete all as specified |
| 62 | M&L for providing roof treatment with APP modified water proofing membrane with the following specifications all as specified and as directed.(a) Removing existing roof/ chajjas treatment of any description like plastic felt / HP tiles of any thickness including taking down existing plastering/ concrete of any thickness and cleaning the top surface of RCC slab with wire brush including removal of debris outside of MOD premises.(b) Brushing with neat cement slurry @ 3Kg/Sqm on cleaned RCC slab surfaces and rendering 20 mm thick in CM 1:3 mixed with approved water proofing compound and finishing surfaces even and smooth without using extra cement.Note: Water proofing compound shall be measured and paid separately.(c) Preparation of plastered surfaces by removing dust, dirt & applying oil bound bituminous primer at 0.3 litre per Sqm & providing APP modified water proofing membrane 4mm thick and weight not less than 4.5kg/ sqm reinforced with non oven polyester mat weight not less than 160gms per Sqm including minimum 10cm side/ over laps & including applying a coat of blown hot bitumen grade 85/25 over membrane at 1.2kg per Sqm & on drying applying a coat of solar reflective bituminous aluminium paint at 0.1kg/sqm.NOTE: APP modified water proofing membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given IS 16540-2017/ IS 16532-2017. Contractor shall produce necessary test certificate of the manufacturer to the Engineer-in-charge before incorporation in the work. Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work. |
| 63 | M&L in repairs to Aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0micron fixed over frame of aluminium tabular section 50x25mmx 2.0mm thick, having panels not exc 1200x1200mm with necessary silicon filling, in approved pattern as in column, beam, wall at any height with necessary scafoldings etc complete as specified and as directed. |
| 64 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed |
| 65 | S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 66 | S&F for pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an coloure having tensile strength of 550Mpa as in roof covering fixed with self tapping screws complete all as specified and directed. |
| 67 | S & F pre-painted galvalume aluminium zinc coating GI based Circular/curvature corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 68 | M&L for aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering complete all as specified and directed. |
| 69 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed. |
| 70 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, etc confirming to Fe-410-W Gde E-250 complete all as specified and directed. |
| 71 | S&F for roof trusses (framed), trussed, purlines, and fasteninf and heavy brackets framing (beam, tee, angle, channel or flats section) including distance pieces, cleat etc conforming to Fe-410 (Gde-E250) quality -A complete all as specified and directed. |
| 72 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 73 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone or steel/ aluminium frame concrete or brick surrounds, glazed complete all as specified and directed |
| 74 | S&F sheet glass 4 mm thick ordinary quality and glazing with aluminium glazing clip in aluminium window/ventilator shutter not exc 0.5 Sqm in each pane complete all as specified and directed |
| 75 | Dismantling wood boarding, panels, beams or any description, fixed any position with nails complete all as specified and directed |
| 76 | S&F 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified |
| 77 | S&F in repair aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staples all as specified and directed |
| 78 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140mm overall length of cover plate complete all as specified and directed |
| 79 | S&F in repair 600x450x6mm thick looking mirror bevelled edge of selected quality glass fixed with stainless steel glass fastner complete all as specified and directed |
| 80 | S&F in repair curtain rods 25mm dia, mild steel, chromium plated with fixing brackets fancy type, stops, rollers etc complete all as specified |
| 81 | S&F in repair door closer hydraulically regulated aluminium (die cast) body, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed |
| 82 | Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed |
| 83 | S&F 20mm outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including suitable reducer for 15mm dia taps fitting as required complete all as specified |
| 84 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed |
| 85 | S&F in repair vitreous china wash down water closed pan (Pedestal pattern) white, including connection to drain (or out going pipe) and to flush pipe, antisypthonic (excluding flushing cistern and flush pipe) complete all as specified and directed |
| 86 | S&F in repair plastic water closet seat cover, white, closed pattern with flat bottom including mild steel chromium plated or aluminised hinging device complete all as specified and directed |
| 87 | S & F in repairs vitreous china wash down single piece WC Rimless Bowl with Cistern for Coupled WC with UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Conversion Bend, Fixing Accessories and Accessories Set, with 'S' or 'P' trap and other connecting items approved brand including fix with white cement complete. Make-Jaquar Cat Pt No.OPS-WHT-15753NS250UFSMZ or equivalent in Parryware/Cera/Prayag |
| 88 | S&F vitreous china water closet Orissa pattern of size 580 X440mm white ISI marked including provn of cement concrete bedding including connections to flushing cistern/pipe and making good disturbed portion to match existing surfaces complete all as specified |
| 89 | S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action push type with inlet ball valve and float including flush pipe long 32mm dia, ball valve, handle, bracket etc complete all as specified and directed |
| 90 | S&F in repair vitreous china counter wash hand basin oval shape of size 550x400mm including brackets, 32 mm CP waste coupling, chain and plug, waste fittings all necessary inlet and out let connections complete all as specified |
| 91 | S&F in repair Vitreous China Urinal, half stall type (back or corner wall type), white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed |
| 92 | S&F 15mm dia brass CP urinal spreader complete all as specified |
| 93 | S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified |
| 94 | S&F in repair 32 mm dia PVC flush pipe of polyethylene of low or high density for WHB, sink, urinal complete all as specified and directed |
| 95 | S&F in repair 32mm waste coupling, brass, chromium plated for glazed ware sinks, basins, urinals etc with long screwed shanks and fly nuts, flange end bedded in red lead cement complete all as specified and directed |
| 96 | S&F in repair 100mm CP waste coupling for sink complete all as specified and directed |
| 97 | S&F in repair chromium plated brass shower roses with or without swivel joints square type 125mm size including shower arm complete all as specified |
| 98 | S&F Brass health faucet 1.0 mtr long flexible tube with wall hook etc complete all as specified and as directed. (Make Prayag Cat Part No. BEA-106 or Equivalent approved) |
| 99 | S&F in repair Toilet paper holder Make : Jaquar Code ACN-1153N or equivalent model in Parryware / Prayag / Gem |
| 100 | S&F in repair towel ring round Make : Jaquar AQN -7721 or equivalent model in Parryware / Prayag / Gem |
| 101 | S&F in repair 20 mm dia brass stainless steel tubular towel rail D type 600mm long complete all as specified and directed |
| 102 | S&F in repair tubular towel rail, brass, chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete all as specified and as directed Make : Jaquar Cat Part No AQN-7711 |
| 103 | S&F in repair chromium plated soap dish of size 120x80mm, fixed to plugs with chromium plated brass screws complete all as specifiedMake : Jaquar Cat Part No CAN-CHR-1131N |
| 104 | S&F in repair 15mm dia cast copper alloy chromium plated long body bib tap fancy type with wall flange complete all as specified and directed |
| 105 | S&F in repair bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed Make : Jaquar Cat Part No CON-107KN |
| 106 | S&F in repair 15mm dia cast copper alloy, chromium plated pillar tap long body swan neck type with fly nut capstan head screwed for 15mm bore dia of pipe complete all as specified and directed |
| 107 | S&F in repairs CP Angular stop cock fancy type with crutch or capstan head handle screwed down for Iron pipe and fixed etc complete all as specified and directed. Make :Prayag Cat No. 7210 or Equivalent approved |
| 108 | M&L for complete removal of existing treatment on wall by scrapping, washing, cleaning etc and applying filling the crack seal of walls with crack seal (on crack portion), and applying two coat of exterior damp proof painting one coat of primer from same manufacturer including necessary scaffolding up to 12 m complete all as specified and directed.Note:- Painting work applied by authorized applicators as per manufacturer instructions. Make: FOSROC (damp proof) or equivalent |
| 109 | S&F in repair 15mm concealed type angle cock cast copper alloy, fancy type, chromium plated with long shunk and cup high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified and directed |
| 110 | Dismantling of ceiling boarding/ wooden boarding in description fixed in any position complete all as specified and directed |
| 111 | M&L for anodised aluminium snap grid frame work for ceiling 605mm x 605mm using aluminium anodised sections as specified in SSR Part-I-1991 including cutting, drilling, jointing etc complete including provn of 3.15mm dia GI wire suspenders fixed with adjustable connectors and providing 4mm thick E-Boards (Classic) 600mm x 600mm size duly applied with two coats of oil bound distemper over a coat of primer all as specified. |
| 112 | M & L for seamless designed gypsum board false ceiling 12mm thick including for any sunk or raised moulding with 25mm long self drilling/ tapping screws having philips head with joining compound and 48mm wide fiber tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flange of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm suspended from soffit at approx 900mm c/c with GI cleats and steel expansion fasteners with and incl ceiling section ( not exc 1.2m length) of 0.55mm thick having kurled web of 50mm an flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting across the intermediate channel at 457mm c/c incl hangers 6mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete and finally applying two coats of oil bound distember with roller finish over a coat of primer cmplete all as specified and directed. |
| 113 | Material & Labour for 4mm thick non asbestos fiber cement building design board of size 605 x 605 mm fixed or laid to aluminium grid work including preparation of surface and two coat of interior emulsion paint all as specified and directed. |
| 114 | Dismantling of floor hearth or wall tiling in patches not exc 3.0Sqm each (not exc 0 .6 mtr wide and any length) including cement mortal bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises |
| 115 | M&L for Glazed ceramic tiles in vertical surfaces such as skirtings, wall, dados and risers to steps etc.surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in CM 1:3 cmplete all as specified and directed. |
| 116 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:4) cmplete all as specified and directed. |
| 117 | M&L for non-skid Ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. and including 15mm thick layer of screed bed in cm 1:6 on floor surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 118 | M&L for light shade vitrified ceramic tiles minimum 10mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in vertical surfaces such as skirting, dados and riser etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed of cement mortar 1:3 complete all as specified and directed |
| 119 | M&L for Vitrified ceramic coloured tiles ( approved shade) of polish area of each tiles not exceeding 0.36 Sqm , 9 to 10 mm thick in floor, set & jointed in neat cement slurry including a layer of screed bed 15mm thick 1:6 and pointed in coloured cement to match the shade of tiles over cement screed bed all as specified Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender