Housing Urban and Rular Development Government Departments Closing in 9 days TDR #58025997

Tender For Providing Puf Panel Roofs And Walls Instead Of Galvalume Sheet Roofs And Walls In Medical Store Shed At Coimbatore Medical College Hospital In Coimbatore District.

Issued by Government Departments · Coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2026
9 days left
EMD
9700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Puf Panel Roofs And Walls Instead Of Galvalume Sheet Roofs And Walls In Medical Store Shed At Coimbatore Medical College Hospital In Coimbatore District.

BOQ

Name of Work:- PROVIDING PUF PANEL ROOFS AND WALLS INSTEAD OF GALVALUME SHEET ROOFS AND WALLS IN MEDICAL STORE SHED AT COIMBATORE MEDICAL COLLEGE HOSPITAL IN COIMBATORE DISTRICT.
Sl. No. Item Description
1Earth work excavation for foundation by manual means for RR/Brick and Other step type footings for Load bearing structures in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
2PLAIN CEMENT CONCRETE 1:5:10 (One cement, five M - sand and ten aggregate) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers.
3Construction BRICKWORK in cement mortar 1:5 (One cement and five M - sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge.
4FOR FOUNDATION AND BASEMENT.
5Providing and Fixing of polyurethane foam as External Wall Thermal insulation 30mm thick PUF panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.
6Providing and Fixing of polyurethane foam for Sloped roof as thermal 30mm (+38mm) thick PUF roof panel insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40 ± 2Kg / M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification.
7Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
8Supplying. Fabricating and fixing of M S GRILL for open court yard grill, grill work to doors, windows and ventilators with required size and angles including with necessary M.S. Channels, ' L ' angles, M.S. Plate as per the approved special designed including cost of materials and labour charges for cutting angle, welding charges including cost of welding rod conveyance charges at site of work including cost of one coat of red oxide primer etc., complete and as directed by the departmental officers.
9PLASTERING with cement mortar 1:5 (One cement and five P - sand) 12mm thick mixed with Bonding Agent cebex 112 Zuvdex, Zucrete 2 X (50Kg) other Equalent compound conforming to BIS at 200ml of one cement bag for increased workablility and air entramment used finishing in all floors including curing etc,. complete complying with standard specifications.
10PAINTING TWO COATS FOR NEW IRON WORKS for doors, windows and ventilators, iron bars, weldmesh, wiremesh, screen, steel bars, flats and other similar works etc., with two coats of approved first quality of synthetic enamel paint over the existing red oxide primer in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. (The paint to be used should be got approved by the Executive Engineer before use on work)
11GST 18% (CGST 9% + SGST 9%) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58025997
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 28-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing Puf Panel Roofs And Walls Instead Of Galvalume Sheet Roofs And Walls In Medical Store Shed At Coimbatore Medical College Hospital In Coimbatore District.
Basic Detail
Tender No 06/08N/CBE-DVN /2026-27
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 14 Oct 2026
Submission Date 28 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 9700
Exemption Not Available
Document List
BOQ_857672.xls
ca985812-9396-4ba2-b89b-221f5e0bb7ed.html
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_857672.xls

html

ca985812-9396-4ba2-b89b-221f5e0bb7ed.html

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender