Tender For Tender Schedule For Construction Of Head Work, Distribution System & Power Supply For Revival Of Kabataguda-Iii L.I.Project Under Pottangi Block Of Koraput District
Tender Value
14.61 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
16 days left
EMD
14619
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Koraput → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tender Schedule For Construction Of Head Work, Distribution System & Power Supply For Revival Of Kabataguda-Iii L.I.Project Under Pottangi Block Of Koraput District
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clods to 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge |
| 2 | Earthwork in excavation of foundation in hard soil such as Hard stiff clay, stiff black cotton, hard red earth, shales, moorum ordinary gravels etc within 50m.Initial lead and 1.5m. Initial lift including rough dressing and levelling the bed and depositing the excavated materials within initial lead at nearby the worksite for reuse including breaking clods and stacking rubble for spreading and leveling as the case may be etc complete as per direction of the Engineer-in-charge. (Excavation by mechanical means 60% & manually 40%) |
| 3 | Filling foundation and plinth with sand watered and rammed as per direction of Engineer-in-charge. |
| 4 | Cement concrete ( 1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge. |
| 5 | Cement concrete ( 1:2:4) with 12 mm size h.g Chips as per direction of engineer-in-charge. |
| 6 | Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete in Column beams,Roof slab,Plinth Bend |
| 7 | Supplying, fitting and placing oncoated HYSD(TISCON) bar reinforcement complete as per drawing and technical specification including cutting , binding , bending and cost of binding wire. |
| 8 | Flyass Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in foundation and plinth. |
| 9 | 12 mm thick cement plaster ( 1:6 ) over Brick masonary |
| 10 | Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 11 | Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge |
| 12 | Filling in F&P with excavated materials in layers not exceeding 0.30m including breaking clods within 50m. initial lead including leveling the tranches as the case may be etc complete as per direction of the Engineer-in-charge.(Quantity by means of Mechanical 60% & mannually 40% i.e. of respective item No. 2 above) |
| 13 | Supplying of 200 mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms. cc,of straight length of 6(six ) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 2.50 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipe as per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe Pre & Post delivery Inspection are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPT ,Bhubaneswar /EPM ,Orissa , Bhubaneswar necessary approval of authority including transporotation and laying at site all complete with cost of solvent cement. |
| 14 | Cost of supplying of 5/8\\" x 12\\" & 5/8\\" x 3\\" & 1/2\\"x2 1/2\\" Nut bolt F.T & 1/8\\" |
| 15 | Cost of supplying of Rubber Insertion |
| 16 | 12.5HP/9.37 KW Energy efficiency Monoblock pump set of total head 20 mtrs having discharge 1700 LPM with squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \\"F\\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery= 100mmx100mm with BEE 3 Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares confirming to IS specification(a) Casing: FC 200 as per IS 210/1978 (b) Impeller: Bronze grade LTB-2 of IS 318/1981 including all cost, conveyance, cess etc complete |
| 17 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 15 HP with 20 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 13.5 to 20 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter, Ameter, MCB in complete shape including Indicator Lamp reputed brand of ISI specification including all cost, conveyance, cess etc complete |
| 18 | Motor hood cover of 18 gauge C.R. sheet(18\\"x18\\"x24\\") with double coat painting over one coat primer so as to cover the motor |
| 19 | MS Base plate for fitting of pannel and pump as per sample |
| 20 | 3 x 10 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS - 7098 (Part - II) including laying below 1 mtr of the ground & fitting the excavated materials including watering & ramming. |
| 21 | 63 AMP Triple Pole Mainswith confirming to IS No.4064(Part I & II) with ISI marking of reputed company having utilisation capacity cagegory AC- 22 reputed brand of ISI specification including all cost, conveyance, cess etc complete |
| 22 | 4 KVAR Power Shunt Capacitor with ISI mark of of reputed approved brand of ISI marked including all cost, conveyance, cess etc complete |
| 23 | 100mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 24 | Letter writings over display Board including painting with enamelled paint .Including cost of materials as per the direction of the Engineer-in-charge. |
| 25 | Labour charges for fitting ,fixing of suction ,delivery fitting including M.S Tee set ,NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete. |
| 26 | 100mm dia C.I.screw base foot valve (Kirloskar make preferbely ) with ISI mark. |
| 27 | 100mm dia G.I.Bend ( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed brand including all cost, conveyance, cess etc complete |
| 28 | 100mm dia G.I.Flange (Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed brand including all cost, conveyance, cess etc complete |
| 29 | 150mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 30 | 150mm dia G.I.Flange (Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed brand including all cost, conveyance, cess etc complete |
| 31 | 100mm dia C.I.Double Flanged Non Return Valve swing type PN-1.0 (IS-5312(Part-I-2004) with bypass arrangement with ISI mark of reputed brand including all cost, conveyance, cess etc complete |
| 32 | 100mm dia C.I.Sluice Valve Flanged type PN-1.0 as per (IS-14846-2000 Standard) with ISI mark of reputed brand including all cost, conveyance, cess etc complete |
| 33 | 100mm dia G.I. Nipple |
| 34 | 200x200x100mm dia G.I. Tee with 200mm ID & 216mm OD, 400mm long welder with 1 mtr.long 100mm dia G.I. pipe(medium duty) welded with two nos. of 100mm dia G.I. Flange in between the one mtr. long G.I. pipe and another 0.25 mtr. long 100mm dia G.I. (medium duty) pipe fitted horizontally with two nos. of 100mm dia G.I. Elbow with water locking arrangement made out of one no. of 100mm dia open flange and one no. of 100mm dia blind flange with hinges, gaskets arrangement to enable inseration of 200mm dia UPVC pipe up to a length of 100mm both sides. The arrangement to be painted with two coats of anti corrosive paint. |
| 35 | 200mm PVC equal Tee (6 Kgf/sqcm)confirming to PL-R PVC-IS 2000F |
| 36 | 50mm dia C.I.A..R Valve IS Mark 14845(SI)with 1 mtr long G.I.Short piece with saddle |
| 37 | 200mm dia PVC end cap confirming to PL-R PVC-IS 2000 F |
| 38 | 100x100x25 mm dia GI Tee for Priming with locking arrengement. |
| 39 | 200x100mm PVC/GI. reducing socket |
| 40 | 200x150mm PVC/GI. reducing socket |
| 41 | 200 mm PVC Sucket |
| 42 | 100mm dia PVC FTA confirming to PL-R PVC-IS 2000 F |
| 43 | 200mm dia PVC Elbow confirming to PL-R PVC-IS 2000 F |
| 44 | Cost of welding, for fitting of G.I.pipe ,G.I.bend, G.I. flange etc. |
| 45 | Labour charges for 200mm PVC Pipe Laying,Fitting. |
| 46 | Electrical Earthing with 40 mm dia medium duty GI earthing pipe each 3 m long with installation including cost of all materials like GI flange chorcoal, salt etc. as required as per I.E Rule |
| 47 | Labour charges for electrical installation with supply of electrical petty materials like 4 sq mm flexible wire, Black tape, Fuse wire,Condute pipe etc. |
| 48 | Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 330 kg 10 M long PSC Pole with 55 Sqmm AAA Conductor average span 40mtr , 11 KV \\"V\\" Cross arm required No.of 11 KV T & C Disc. polymer Insulators in tension point & 11 KV Pin Polymer insulators, Couping & Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required. including cost of all materials, labour transportation,inspection & commissioning etc. complete. |
| 49 | Construction and erection of 11 /0.4 KV, 25 KVA Double Pole mounted Substation with Polymer insulator ,L.T Dist Box with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of 40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 330 kg 10 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, Brick Boundary wall with gate,sand and metal spreading as per TPSODL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning as per specification of TPSODL etc complete. |
| 50 | Construction of 3 Phase L.T line as per REC standard confirming to RE rule 1956 with 300Kg 9 Mtr long PSC pole support in 0.30 M span length with 4x35mm² +1x35 mm ² LT, XLPE AB cable with coil earthing device, LT dead end clam, Suspension clamp with G I hook , stay accessories such as wire insulator , clamp etc. nut bolts, alongwith concreting copping & padding of poles and stayset as per direction of Engineer in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender