Tender For Provision External Power Supply At Rw Sub Division Paikmal For The Year 2026-27_Building
Tender Value
9.28 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
11 days left
EMD
9282
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sambalpur → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision External Power Supply At Rw Sub Division Paikmal For The Year 2026-27_Building
BOQ
| Sl. No. | Item Description |
| 1 | 55 sqmm AAAC |
| 2 | 9mtr 150X150 RSJ POLE 30.6KG |
| 3 | 75X40X6MM GI Channel for straight Cross |
| 4 | 11KV V-Cross Arm GI (10.2 KG each) |
| 5 | GI Back Clamp for V Cross Arm( 1.7 kg) |
| 6 | 11KV F clamp 2.9 KG each GI |
| 7 | 11KV B&S Disc Insulator polymer 70KN |
| 8 | 11KV B&S Hardware fitting |
| 9 | PG Clamp for 100sqmm AAAC |
| 10 | 11KV Pin insulator polymer |
| 11 | HT Stay set complete |
| 12 | HT Stay set Insulator |
| 13 | Stay Clamp |
| 14 | 7/10 SWG stay wire |
| 15 | 8 SWG GI wire (for earthing) |
| 16 | GI Nuts,Bolt&Washer |
| 17 | Earthing of support (Coil Type) |
| 18 | Concrete material for stay anchor plate |
| 19 | Padding & Concreting material for support |
| 20 | Survey and GIS data for pole |
| 21 | Pole painting under LT/11KV/33KV Network |
| 22 | Pole PSC 9 meter 300KG |
| 23 | Cable 1.1KV AB 3X35+1X25+1X16sqmm 5W |
| 24 | POLE clamp |
| 25 | Clamp Dead end |
| 26 | Clamp suspension with EYE hook for AB cable |
| 27 | Eye hook for AB Cable |
| 28 | Neutral Connector |
| 29 | Wire GI stranded 7/12 swg -7/2.64mm |
| 30 | line stay clamp for LT |
| 31 | Insulator stay for LT |
| 32 | Earthing coil |
| 33 | Earth GI NO 8 SWG/4.06 MM for Earthing |
| 34 | Bolt & Nut GI 16X55 MM |
| 35 | Piercing connector LT type A |
| 36 | LT stay set complete |
| 37 | DIST BOX LT POLYCARBONATE( 10 WAY) |
| 38 | Concrete material for stay |
| 39 | Padding & Concreting material for support |
| 40 | Survey and GIS data for pole |
| 41 | Pole painting under LT/11KV/33KV |
| 42 | 9mtr 150X150 RSJ POLE 30.6KG |
| 43 | 25 KVA 11/0.4 KV Level-II (amndmnt 4 IS |
| 44 | GI Channel 100x50x6mm |
| 45 | GI Channel 75x40x6mm |
| 46 | GI Angle 50x50x6mm |
| 47 | 11KV Polymer Disc insulator B&S (70KN) |
| 48 | 11KVH/W Fitting for Disc (70KN) |
| 49 | PG Clamp for 100sqmm AAAC |
| 50 | GI Flat 50x6mm |
| 51 | GI Flat 25x6mm |
| 52 | 11KV A/B Switch (400A,3 POLE HZ TYPE) |
| 53 | 11KV HG FUSE (200A,3 POLE ,HZ Type) |
| 54 | 11 KV lighting arrester |
| 55 | Conductor ACSR PVC( 61.7SQ MM) |
| 56 | HT Stay set complete |
| 57 | HT stay set insulator |
| 58 | HT Stay Clamp |
| 59 | 7/10 SWG stay wire |
| 60 | 8 swG GI wire (for earthing) |
| 61 | 40 mm nominal bore GI pipe (medium gauge) |
| 62 | Earthing for support (Coil type) |
| 63 | Pipe HDPE 25 MM |
| 64 | Pipe GI (100MM) |
| 65 | 1.1 KV 4CX95 Sqmm XLPE Cable |
| 66 | 1CX95 MM2 LT XLPE Cable (Armoured) |
| 67 | Gland for Arm( 4CX95 sqmm XLPE Cable) |
| 68 | Dist Box with TP MCCB (25KVA) |
| 69 | AI Cable socket 70mm |
| 70 | AI Cable socket 95mm |
| 71 | GI Bolt, Nuts & Washers |
| 72 | GI Barbered wire for Anticlimbing |
| 73 | Danger Plate |
| 74 | Concrete material for stay Anchor plate |
| 75 | Padding & Concreting material for support |
| 76 | Economic Brick Design fencing |
| 77 | Earthing pit for pipe earthing |
| 78 | Pole painting under LT/11KV/33KV |
| 79 | Survey and GIS Data for DTR |
| 80 | Survey and GIS data for pole |
| 81 | SITC of 400mm Wall fan copper winding with metal blades having air delivery ≥ 70 m³/min. (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Crompton-WM HiFlowwave/Havells-Accelero HS/Anchor-Altrix HS-OWH/Orient-Wall43/Great White-WYNO WF) with all accessories and connection etc. as required as per direction of Engineer-in-charge, Replacement Warranty will be two years. |
| 82 | Supply and installation of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more complete with base plate 250x250x16mm and 4 nos. Jtype En 8 grade foundation bolts M24X750mm to withstand 180 KM / HR wind speed considering the weight & dimension of One no. Solar lights fixed on the top of the bracket . The Pole must be suiable to withstand 180 KM/Hr wind speed by considering the weight and wind expose area of one no Semi Integrated/AIO Solar lights at a height of 6 mtr above ground .Both the Octagonal Pole and EN8 grade fdn bolts must be manufactuered by Octagonal pole manufacturing company. Brackets & EN8 fdn bolts manufactured in third party Supplier/manufacturer shall not be acceptable.The necessary test reports of Octagonal Pole and EN8 grade fdn bolts must be submitted by the manufacturer for acceptance of product/TDS approval prior to start of the work.The pole manufacturer must submit the confirmation regarding 10 years or more design life of the pole. Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with Solar light on that foundation. The work shall be excuted as per the direction of EIC Installation of 6 mtr pole and fixing the solar light on the top of the bracket so that all the solar lights shall be installed at a height of 6mtr above ground on that foundation by using suitable machinery by taking all safety precautions as per the direction of EIC. Make : - Utkarsh/RR Ispat/Vakrangee) |
| 83 | Supply,installation,testing and commissioning of 40 W Semi Integrated type Solar street lights having 100 Wp or more highly efficient Monocrystalline PV module & 12.8 V 42 Ah or more ( Lithium Ferrophosphate (LiFePo4) Battery having BIS ) which shall be inside the die cast alluminium housing luminaire housing (Theft retardant type), MPPT charge controller having > 92% efficiency & PIR Sensor. The initial lumen output of AIO street light shall be >6400 lumen or more in CCT 6000K (+/-500K) , Lumen efficacy > 160 lm/w as per LM 79 report of NABL Lab. The LED chip will be of OSRAM/NISCHIA/CREE/SEOUL Semiconductor only and should be with lenses for effective lighting distribution. The complete system & BMS should be designed to provide 2 days (24Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) , Multi purpose SA bracket to mounted on the ARM in south direction. The luminaire must be having I die cast alluminium housing street light with IP 66 protection for critical component like (LED compartment, Driver compartment & Battery) & IK 08 . The solar street lighting company has to supply Solar Panel , Solar light , battery , PIR sensor , Multipurpose SA bracket & other accessories with provision to fix the solar panel towards south direction for faster charging of battery. The Solar street light and the multipurpose Arm shall be fixed in Pole. The solar street lighting company has to offer Warranty on complete lighting system for a period of 5 years. The solar lighting company must submit the warranty certificate in the department by mentioning 5 years warranty on complete lighting system I.e, Light, Charge controller, Battery, Solar Panel, Module Mounting structure, Multipurpose Single Arm bracket etc against manufacturing defects. Solar lighting company has to repair/replace the lighting system if required against the manufacturing defect till compleiton of warranty period. The Agency/Contractor has to maintain the lighting system till the completion of warranty period by considering the periodical maintenance like panel cleaning in regular interval and rectifying the defect by engaging labour/machinery to make the lighting system operative till warranty period. The agency/contractor must submit declaration for maintaining the system till warranty period. The Necessary after sales service to against manufacturing defects to be provided Solar lighting company through their Toll free base service service set up within 100 to 150 KM from the project site. The following test reports/certifications must be submitted for the technical acceptance of the products . 1. LM 79 REPORT NABL lab ) , 2. IK 08 (Report of NABL lab ), 3. IP 65 Report of NABL lab (The necessary test reports of NABL lab against the above must be submitted for any wattage of Solar Street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of Solar Lighting Company (Make:Crompton/Havells/Panasonic/Philips/Wipro) |
| 84 | Supply and installation ,testing and commissioning of 50 W AIO Solar street lights having 125 Wp or more highly efficient Monocrystalline PV module & 12.8 V 48 Ah or more ( Lithium Ferrophosphate (LiFePo4) Battery having BIS ) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), MPPT charge controller having > 92% efficiency & PIR Sensor. The initial lumen output of AIO street light shall be> 8000 lumen or more in CCT 6000K (+/-500K) (Lumen efficacy of 160 lm/w ) as per LM 79 report of NABL lab . The LED chip will be of OSRAM/NISCHIA/CREE/SEOUL Semiconductor only and should be with lenses for effective lighting distribution. The complete system & BMS should be designed to provide 2 days (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 66 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. Warranty on the AIO street lights must be 5 years . The solar lighting company must submit the warranty certificate in the department by mentioning 5 years warranty on complete lighting system against manufacturing defects. Solar lighting company has to repair/replace the lighting system if required against the manufacturing defect till compleiton of warranty period. The Agency/Contractor has to maintain the lighting system till the completion of warranty period by considering the periodical maintenance like panel cleaning in regular interval and rectifying the defect by engaging labour/machinery to make the lighting system operative till warranty period. The agency/contractor must submit declaration for maintaining the system till warranty period .The following test reports/certifications must be submitted for the technical acceptance of the products .1. LM 79 REPORT NABL lab ) , 2. IK 08 (Report of NABL lab ), 3. IP 66 Report of NABL lab against the above must be submitted for any wattage of Solar Street lights for acceptance of product/TDS approval prior to start of the work. All the test reports must be in the name of Solar Lighting Company (Make:Crompton/Havells/Panasonic/Philips/Wipro) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender