Housing Urban and Rular Development Government Departments Closing in 12 days TDR #58024325

Tender For Upgradation And Improvement Of Electric Network By Way Of Sub Mains / Mccb / Electric Fitments At Civil Secretariat Srinagar.

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
6.96 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
12 days left
EMD
13920
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation And Improvement Of Electric Network By Way Of Sub Mains / Mccb / Electric Fitments At Civil Secretariat Srinagar.

BOQ

Name of Work:- Upgradation and Improvement of electric network by way of Sub mains / MCCB / Electric fitments at Civil Secretariat Srinagar.
Sl. No. Item Description
1Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/ eqv Make) & shall be approved before execution of work (Including Cost of Conduit/Channel)
22x10 sq.mm+ 1x16 sq.mm Earth for Power point/Machine Point Sub main in One run from Main Panel to Distribution Boards.
32x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting Sub main in One run from Main Panel to Distribution Boards.
42x4 sq.mm+ 1x4 sq.mm (P+N+E) for Inverter/AC Sub main in One run from Main Panel to Distribution Boards.
5Supply/Fixing/Testing and Commissioning of 6Amp to 32 Amp Rating SP,240 volt C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/Schneider/Eton/eqv Make)
6Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Schneider Make)
732 Amp
840Amp.
963Amp.
10Supplying and Fixing of MCB 8 (4+24) ways horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider Make)
11Supplying and Fixing of MCB 4 (4+12) ways horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider Make)
12Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 200 Amp-4-Pole ,36kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 400 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.125 Amp. 4-pole changeover tp bypass between main supply and generator supply.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB = 04 No. for Heating Sub-main.(b) 40-Amp DP MCB= 04 No. for Lighting/Machine Sub-main(c) 32-Amp DP MCB = 04 No. for inverter Sub-main and AC Points
13Supply/Laying/Connecting and Commissioning of 25 sq.mm 2Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
14Supply/Laying/Connecting and Commissioning of 35 sq.mm 2Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
15Supply/Laying/Connecting and Commissioning of 120 sq.mm 3.5Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
16Maintenance Free copper rod earthing system with soil treatment to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from earthing rod up to main Control panel through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
17Supply/Laying of 25/32/38mm Dia and 2mm thick PVC Conduit/Lockable Channel of Anchor/Ravindra Blue/Finolex Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc.
18Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 100 Amp,415V Ac,50Hz offload Manual Changeover Switch side handle in enclosure Havells/L &T/ABB Make including S/F/Crimping of Suitable Size of thimbles for connections as per site requirement
19Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface, complete as required
20Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 125 Amp-2-Pole ,16kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 250 Amps P&N Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB = 02 No. for Heating Sub-main.(b) 40-Amp DP MCB= 02 No. for Lighting/Machine Sub-main
21Supply/Laying/Connecting and Commissioning of 50 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
22Supply/Installation/Testing and Commissioning of 3-Phase, Four Pole 200 Amp,415V Ac,50Hz 36KA S/F/Crimping of Suitable Size of thimbles for connections as per site requirement
23Supply/laying/Testing and Commissioning of 10mm sq single core FRLS PVC insulated duly Crimped by way of Suitable Size of thimbles for connections as per site requirement
24Supply/laying/Testing and Commissioning of 16mm sq single core FRLS PVC insulated duly Crimped by way of Suitable Size of thimbles for connections as per site requirement
25Supply/Laying/Connecting and Commissioning of 70sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/RR Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
26Supplying and Fixing of MCB 4 ways [4+4} VERTICALtyped , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider Make)
27Providing and laying of 2.5 sq mm copper wire polycab/anchor/apaar eqv make . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58024325
AUTHORITY Government Departments
TENDER VALUE 6.96 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation And Improvement Of Electric Network By Way Of Sub Mains / Mccb / Electric Fitments At Civil Secretariat Srinagar.
Basic Detail
Tender No e-NITNo. 22-P of 10/2026 Dated- 13-10-2026
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 14 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value 6.96 Lakhs
Tender Fee 300
EMD 13920
Exemption Not Available
Document List
BOQ_1110297.xls
f641968e-deda-49fc-a4a7-b46a8c2a5e96.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1110297.xls

html

f641968e-deda-49fc-a4a7-b46a8c2a5e96.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender