Housing Urban and Rular Development Government Departments Closing in 7 days TDR #58024322

Tender For B.O.Q For Upgradation Of Court Room At Dc Office Complex Anantnag B.W.O Electric Work

Issued by Government Departments · Anantnag, Jammu and Kashmir
Tender Value
4.99 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
7 days left
EMD
9980
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Upgradation Of Court Room At Dc Office Complex Anantnag B.W.O Electric Work

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 CORRIGENDUMNIT192CC Date 30-Oct-2026
2 22-Oct-2026 CORRIGENDUMNIT192C Other 30-Oct-2026
3 14-Oct-2026 CORRIGENDUM Other 30-Oct-2026
4 14-Oct-2026 CORRIGENDUM Other 23-Oct-2026
5 22-Oct-2026 CORRIGENDUMNIT192C Other 09-Nov-2026
6 14-Oct-2026 CORRIGENDUM Other 09-Nov-2026
7 31-Oct-2026 CORRIGENDUM Date 09-Nov-2026

BOQ

Name of Work:- B.O.Q for Upgradation of court room at DC Office complex Anantnag B.W.O Electric work
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan point/call bell point with 2 × 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, ( Havell/ Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor or equal, complete with all accessories as required; single core cable in surface / recessed medium class PVC conduit ( including cost of conduit), with modular switch ( Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group-A
3Group-C
4Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( including cost of conduit)
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree/ Athena/ ABB make.)
6Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( including cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
7Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5-10 A modular socket outlet and 2 no. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree /Athena/ ABB make.)
8Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excludingmodular plate etc. as required. i. 3 pin 5/6A socket outlet
9Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excludingmodular plate etc. as required. i. Indicator
10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 , single core cable in surface/ recessed medium class PVC conduit as required. Including cost of conduit.
112 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Inverter Circuit)
122 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Lighting Circuit)
132 X6 sq. mm + 1 X 6 sq. mm earth wire ( Lighting submain/ AC Wiring)
144 X 16 sq. mm + 2 X 6 sq. mm earth wire ( Heating submain)
15S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve ,Schneider / Legrand /ABB, / Havells ,/ Siemens/ L&T / Hager /BCH make OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer in charge.
166-32 Amp SP MCB
1740amp DP MCB
1863amp DP MCB
1963amp TPN MCB
20Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates.
21Supplying and fixing following way, Horizontal type,Single pole and neutral, sheet steel, MCB distribution board,( legrand/ Schneider/Hager/ABB make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
224 way (4+12), Double door
23Supply installation testing and commissioning of 10/12 W LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminum Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, separate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havel's /Wipro make / sample to be approved before installation..
24Supply, installation, testing and commissioning of exhaust fan of 200-250 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter, and all accessories as required; the fan shall be of robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades, and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements of Havell /Bajaj/Crompton/ USHA/Orient OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge as per site requirement and necessary connections.
25Supply, installation, testing and commissioning of 400mm sweep wall fans, incl. cost of ceiling rose and making of and necessary connections. (Havells/ Philips).
26Supply and fixing of LED ambient strip light 40- 45 Watt. System wattage 6W/M (Philips / Panasonic/ Havells/ Agroculture)
27S/Laying ( partly overhead/ partly underground) , testing and commissioning of XLPE aluminum armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Havell/Eq. standard make as directed by engineer in charge and making end termination with brass compression gland and aluminum lugs of required size.
2850 sq.mm 3.5 core ( armoured)
29PANEL : Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminum Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. The scope of work also entails securely installing the panel into the ground with concrete encasing its legs (As per approved design,size may vary as per site requirement)
30INCOMING
31250 amp FP MCCB 36 KA Legrand /Schneider/L&T/ABB make.
324 No. of Aluminum Bus Bar of 500 Amp.
33Change over switch 63 Amp Front operated
344 No. of Aluminum Bus Bar of 100 Amp
35Digital meters and phase indicators -2 set.
36OUTGOING
3763 amp TPN 10KA MCB
3863 amp DP 10KA MCB
39Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick in size.
40Providing of chemical earthing as per IS standards by way of digging 6 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the electrode with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound.
41Supply of 1.5 ton Capacity Wall mounted Split Air conditioners,(hot & cold) Rated cooling capacity in Watts as per IS:1391 (Part 2) 3 star rating inverter type fitted with hermitically sealed Rotary type compressor (INVERTER rotary compressor (Variable Speed) ) operating on 230V ±10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes with aluminum fins, cordless remote control, copper piping for both suction and discharge of three(03) meters length with protection covering for piping rubber insulation, of suitable size of medium PVC pipe, power and control cabling as per site requirement, comprising of following etc. complete as per requirement. a) Insulated copper pipe lines liquid and suction lines as per manufacturer recommendation with OEM standard Eco-friendly Refrigerant Gas. b) Flexible copper cable between indoor & outdoor Unit of suitable size as per Manufacturer recommendation 3Cx2.5Sq.mm copper flexible Minimum 3 meters Length c) PVC Drain Pipe as per the OEM standard and Site conditions d) Suitable size of Rubber Insulation & protective covering of refrigerant line. DAIKIN/ MITSUBISHI/ CARRIER/HITACHI / IFB/ BLUESTAR/VOLTAS/LG make . The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one year from date of successful commissioning.
42Installation, Testing & commissioning of 1.5 Ton Capacity Wall mounted Split Air conditioners including all necessary accessories, fixing of indoor Unit, fixing of Outdoor Unit on Dully painted suitable size MS Stand including grouting/mounting of stand, first charging of refrigerant with laying of Insulated copper pipe lines liquid and suction lines and Installation of Drain pipe etc. complete as per site requirement
43Supply of wall Mounting type 4KVA capacity, Metal body, single phase, Automatic line Voltage stabilizers with copper wound coil having an input voltage 135 to 275V and a balanced/steady output voltage of 220 V +_ 3%, single phase, 50Hz AC with built in time delay, cut off and low voltage cut-off, i/p, o/p trip indications, metal clad top etc., with connecting 3 core cable of 1 meter length complete etc.as per site requirement. EVEREST/V-GUARD/ PREMIER/ Liv Guard/ Servocon or eq.
44Supply and installation of 32A modular plug / socket with 32A DP MCB for ACs. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58024322
AUTHORITY Government Departments
TENDER VALUE 4.99 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Upgradation Of Court Room At Dc Office Complex Anantnag B.W.O Electric Work
Basic Detail
Tender No NIT No.192/2026-27 Dt 13/10/2026
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 22 Oct 2026
Submission Date 09 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 4.99 Lakhs
Tender Fee 200
EMD 9980
Exemption Not Available
Document List
7960a179-621b-4a9b-8506-4d3f307e799d.html
BOQ_1110362.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 23, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 09, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Nov 09, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Nov 09, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

7960a179-621b-4a9b-8506-4d3f307e799d.html

xls

BOQ_1110362.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender