Tender For Repairing And Renovation Of Thaplaghora Me School. (Udise Code-18010322101)
Tender Value
71 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
10 days left
EMD
1.42 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chirang → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing And Renovation Of Thaplaghora Me School. (Udise Code-18010322101)
BOQ
| Sl. No. | Item Description |
| 1 | Repairing of Staff Room:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Dismantling cement asbestos or other hard board ceiling or partition: walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately).12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. |
| 6 | Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete:12.66.1 Precoated/mill finish aluminium Ridges plain (500-600mm) |
| 7 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 8 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 9 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments:11.46.2 Size of Tile 600x600 mm |
| 10 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 11 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.9.9.2 Kiln seasoned and chemically treated hollock wood 9.9.2.1 35 mm thick |
| 12 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary screws etc.9.3.2 Kiln seasoned and chemically treated hollock wood |
| 13 | Providing and fixing plain multipurpose cement board (High pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid separately).12.26.1 6 mm thick Cement fiber board as per IS: 14862 |
| 14 | 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.1 1:4 (1 cement: 4 fine sand)b) In cement mortar 1:4 |
| 15 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:9.97.2 250x10 mm |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 17 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:13.43.1 Water thinnable cement primer |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade:13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 19 | Applying priming coat: 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 20 | Painting with oil type wood preservative of approved brand and manufacture:13.57.1 New work (two or more coats) |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation. |
| 22 | Repairing Existing Claasroom:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 23 | Dismantling cement asbestos or other hard board ceiling or partition: walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 24 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:15.28.1 G.S. Sheet |
| 25 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 27 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.12.2 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 28 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately).12.65.1 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. |
| 29 | Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete:12.66.1 Precoated/mill finish aluminium Ridges plain (500-600mm) |
| 30 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 31 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 32 | Renewing wooden battens in roofs, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.14.15.1 Sal wood battens |
| 33 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 Sal wood |
| 34 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.9.9.2 Kiln seasoned and chemically treated hollock wood 9.9.2.1 35 mm thick |
| 35 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary screws etc.9.3.2 Kiln seasoned and chemically treated hollock wood |
| 36 | Providing and fixing plain multipurpose cement board (High pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid separately).12.26.1 6 mm thick Cement fiber board as per IS: 14862 |
| 37 | 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.1 1:4 (1 cement: 4 fine sand)b) In cement mortar 1:4 |
| 38 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:9.97.2 250x10 mm |
| 39 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 40 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:13.43.1 Water thinnable cement primer |
| 41 | Finishing walls with Acrylic Smooth exterior paint of required shade:13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 42 | Applying priming coat: 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 43 | Painting with oil type wood preservative of approved brand and manufacture:13.57.1 New work (two or more coats) |
| 44 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation. |
| 45 | Const of Classroom:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 46 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 47 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 48 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 49 | Centering and shuttering including strutting, propping etc. and removal of form for:5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 50 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form for:5.9.5 Lintels, beams, plinth beams, girders, bressummers and cantilevers |
| 52 | Centering and shuttering including strutting, propping etc. and removal of form for:5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 53 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 54 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 55 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 56 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 57 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 58 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 59 | 15 mm thick cement plaster in single coat on rough side of single or half brick wall:13.5.1 1:4 (1 Cement : 4 Coarse Sand) |
| 60 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:13.43.1 Water thinnable cement primer |
| 61 | Finishing walls with water proofing cement paint of required shade:13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 62 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 63 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately).12.65.1 0.56 mm, Aluminium Color coated troughed profile. |
| 64 | Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness, Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete:12.66.1 Precoated/mill finish aluminium Ridges plain (500-600mm) |
| 65 | Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.8.25.2 25mm thick |
| 66 | Applying priming coat:13.50.2 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 67 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80mm having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with raw plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound, jointing tapes, finishing with jointing compound.12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-(Part I):2011 (Board with BIS certification) |
| 68 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 Kiln seasoned and chemically treated hollock wood |
| 69 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)9.5.1 Second class teak wood9.5.1.1 35 mm thick shutters |
| 70 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications:13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm |
| 71 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 72 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:9.72.1 125x85x5.5 mm (heavy type) |
| 73 | Providing and fixing chromium plated brass handles with necessary screws etc. complete:9.92.3 75 mm |
| 74 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish.9.63.1 250x10 mm |
| 75 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete:9.62.2 250x16 mm |
| 76 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 77 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 78 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 79 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 80 | Electrical Works Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender