Housing Urban and Rular Development Government Departments Closing in 4 days TDR #58022402

Tender For E-Rate Quotation Of Non Dsr Items For Preparation Of Estimate For Providing And Fixing Bio Septic Tank (Bio Digester) For Verious Building Of P.W. Deptt. Dist. Nashik

Issued by Government Departments · Nashik, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2026
4 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for E-Rate Quotation Of Non Dsr Items For Preparation Of Estimate For Providing And Fixing Bio Septic Tank (Bio Digester) For Verious Building Of P.W. Deptt. Dist. Nashik , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 500 Litre Capacity Having Horizontal Cylindrical Shape, Upto 8 User Total Weight Of Frp: - 70 Kilogram Diameter :-0.75 And Length:-1.20M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :-500G, Minimum Thickness Of Side Walls / Top And Bottom: 10Mm, Minimum Thickness Of Partition Wall : 10Mm. Inlet And Outlet Size Rigid Pvc :-110 Mm, Gas Outlet :-75 Mm , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 1000 Litre Capacity Having Horizontal Cylindrical Shape, Upto 16User Total Weight Of Frp: - 110 Kilogram Diameter :-1.05 M And Length:-1.2M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :-1000 G, Minimum Thickness Of Side Walls / Top And Bottom : 10Mm, Minimum Thickness Of Partition Wall : 10Mm. Inlet And Outlet Size Rigid Pvc :-110 Mm, Gas Outlet :-75 Mm , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 2000 Litre Capacity Having Horizontal Cylindrical Shape, Upto30 User Total Weight Of Frp: - 150 Kilogram Diameter :-1.2M And Length:-1.8M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :- 2000G, Minimum Thickness Of Side Walls / Top And Bottom : 10Mm, Minimum Thickness Of Partition Wall : 10Mm.Inlet And Outlet Size Rigid Pvc :-110 Mm,Gas Outlet :-75 Mm , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 3000 Litre Capacity Having Horizontal Cylindrical Shape, Upto 50 User Total Weight Of Frp : - 185 Kilogram Diameter :-1.27 And Length :- 2.44M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :- 3000G, Minimum Thickness Of Side Walls / Top And Bottom : 10Mm, Minimum Thickness Of Partition Wall : 10Mm.Inlet And Outlet Size Rigid Pvc :- 110Mm,Gas Outlet :-75 Mm

BOQ

Name of Work:- E-Rate Quotation of Non DSR Items for Preparation of Estimate for Providing and Fixing Bio Septic Tank (Bio Digester) for Verious Building of P.W. Deptt. DIst. Nashik
Sl. No. Item Description
1Supplying of FRP (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank of 500 Litre capacity having horizontal cylindrical shape, Upto 8 user Total weight of FRP: - 70 Kilogram diameter :-0.75 and length:-1.20m,4 internal partitions 0.3 m length each, Bacteria inoculums quantity :-500g, Minimum thickness of side walls / top and bottom: 10mm,Minimum thickness of partition wall : 10mm. Inlet and Outlet size rigid PVC :-110 mm, Gas Outlet :-75 mm
2Supplying of FRP (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank of 1000 Litre capacity having horizontal cylindrical shape, Upto 16user Total weight of FRP: - 110 Kilogram diameter :-1.05 m and length:-1.2m,4 internal partitions 0.3 m length each, Bacteria inoculums quantity :-1000 g, Minimum thickness of side walls / top and bottom : 10mm,Minimum thickness of partition wall : 10mm. Inlet and Outlet size rigid PVC :-110 mm, Gas Outlet :-75 mm
3Supplying of FRP (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank of 2000 Litre capacity having horizontal cylindrical shape, Upto30 user Total weight of FRP: - 150 Kilogram diameter :-1.2m and length:-1.8m,4 internal partitions 0.3 m length each, Bacteria inoculums quantity :- 2000g, Minimum thickness of side walls / top and bottom : 10mm,Minimum thickness of partition wall : 10mm.Inlet and Outlet size rigid PVC :-110 mm,Gas Outlet :-75 mm
4Supplying of FRP (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank of 3000 Litre capacity having horizontal cylindrical shape, Upto 50 user Total weight of FRP : - 185 Kilogram diameter :-1.27 and length :- 2.44m,4 internal partitions 0.3 m length each, Bacteria inoculums quantity :- 3000g, Minimum thickness of side walls / top and bottom : 10mm,Minimum thickness of partition wall : 10mm.Inlet and Outlet size rigid PVC :- 110mm,Gas Outlet :-75 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58022402
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for E-Rate Quotation Of Non Dsr Items For Preparation Of Estimate For Providing And Fixing Bio Septic Tank (Bio Digester) For Verious Building Of P.W. Deptt. Dist. Nashik , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 500 Litre Capacity Having Horizontal Cylindrical Shape, Upto 8 User Total Weight Of Frp: - 70 Kilogram Diameter :-0.75 And Length:-1.20M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :-500G, Minimum Thickness Of Side Walls / Top And Bottom: 10Mm, Minimum Thickness Of Partition Wall : 10Mm. Inlet And Outlet Size Rigid Pvc :-110 Mm, Gas Outlet :-75 Mm , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 1000 Litre Capacity Having Horizontal Cylindrical Shape, Upto 16User Total Weight Of Frp: - 110 Kilogram Diameter :-1.05 M And Length:-1.2M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :-1000 G, Minimum Thickness Of Side Walls / Top And Bottom : 10Mm, Minimum Thickness Of Partition Wall : 10Mm. Inlet And Outlet Size Rigid Pvc :-110 Mm, Gas Outlet :-75 Mm , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 2000 Litre Capacity Having Horizontal Cylindrical Shape, Upto30 User Total Weight Of Frp: - 150 Kilogram Diameter :-1.2M And Length:-1.8M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :- 2000G, Minimum Thickness Of Side Walls / Top And Bottom : 10Mm, Minimum Thickness Of Partition Wall : 10Mm.Inlet And Outlet Size Rigid Pvc :-110 Mm,Gas Outlet :-75 Mm , Supplying Of Frp (Fibre Reinforced Plastic) Bio-Septic Tank/Bio-Digester Tank Of 3000 Litre Capacity Having Horizontal Cylindrical Shape, Upto 50 User Total Weight Of Frp : - 185 Kilogram Diameter :-1.27 And Length :- 2.44M, 4 Internal Partitions 0.3 M Length Each, Bacteria Inoculums Quantity :- 3000G, Minimum Thickness Of Side Walls / Top And Bottom : 10Mm, Minimum Thickness Of Partition Wall : 10Mm.Inlet And Outlet Size Rigid Pvc :- 110Mm,Gas Outlet :-75 Mm
Basic Detail
Tender No e-Quotation Notice No.25 for 2026-27
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 14 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
16ba3ef8-4923-4095-a09b-f9ffbfafdfa0.html
BOQ_2296124.xls
Notice25nd.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

16ba3ef8-4923-4095-a09b-f9ffbfafdfa0.html

xls

BOQ_2296124.xls

pdf

Notice25nd.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender