Tender For Comprehensive Repair And Maintenance Of Street/ Security Light Fittings, Jetty Tower Lights, Solar Street Light, Transit Lights And Connected Works At Site ‘A Of Naval Base Area Karwar.
Tender Value
49.90 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
6 days left
EMD
99800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Repair And Maintenance Of Street/ Security Light Fittings, Jetty Tower Lights, Solar Street Light, Transit Lights And Connected Works At Site ‘A Of Naval Base Area Karwar.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully old defective LT UG cables of any size including cable protection pre cast concrete cover / bricks from the trenches and keeping aside for reuse/disposal complete all as specified and directed. |
| 2 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/ wall/ floors/ ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed. (Excavation & earth work, sand cushioning and PCC cover for cable protection will be measured & paid for separately) |
| 3 | All as per item No 2 above but cross sectional area 10 Sqmm 4 core |
| 4 | All as per item No 2 above but cross sectional area 25 Sqmm 3.5 core |
| 5 | All as per item No 2 above but cross sectional area 6 Sqmm 4 core |
| 6 | Supplying and laying of 40 mm internal dia DWC double wall HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc complete in repair all as specified and directed. |
| 7 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed. |
| 9 | Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 10 | Supply and laying galvanised iron tubing, light grade of size 40 mm dia with all fittings as in cable protection, laid in trenches, including taking down existing unserviceable GI pipes & its connections complete all as specified and directed by Engr-in-Charge. |
| 11 | S&F new generation, post top lantern, garden light or bollard light fitting 25 W LED, IP-65, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with driver complete in repair all as specified and directed by Garrison Engineer. Make: i) Post top lantern - Cat part No: Crompton - CBP-610-25-57-SL-CA-NBK or equivalent in Panasonic/ Bajaj/ Havells. ii) Garden light, Cat part No: Jaquar- MLED-MABOL-16L or equivalent Panasonic/ Bajaj/ Havells. |
| 12 | S&F contactor MNX-32, 3 Pole, 415 volt coil voltage 230 volt complete as in street light timer assembly including removing old unserviceable contactor complete in repairs all as specified and directed by Engr-in-Charge. |
| 13 | S&F contactor MNX-40, 3 Pole, 415 volt coil voltage 230 volt complete as in street light timer assembly including removing old unserviceable contactor complete in repair all as specified and directed by Engr-in-Charge. |
| 14 | S&F digital weekly programmable time switch for controlling street lights Single Phase 230 volt complete of capacity 15/16 Amp complete in repair all as specified. |
| 15 | S&F MCCB 63 amps rupturing capacity 16 KA, 4 pole 415 volts AC with fixed thermal magnetic release complete in repair all as specified and directed by Engr-in-Charge. |
| 16 | S&F MCB Triple Pole & Neutral, 50 to 63 Amp, 415 Volts, 10 KA capacity 'C' curve series complete in repairs all as specified & directed. |
| 17 | S&F MCB, single pole 6 to 32 Amp, 240 Volts, 10 KA Capacity 'C' curves series complete in repairs all as specified & directed. |
| 18 | S&F FRP cable looping boxes of size 300 mm x 200 mm x 105 mm with TPN aluminium busbar and MCB SP 6 Amp- 01 No, 10 KA breaking capacity, B curve series, factory made with PVC sheet including heavy duty connector for connection of 4 core cable & fixed to pole with suitable size flat iron clamp, nuts & bolts complete in repairs all as specified and directed by Engr-in-Charge. |
| 19 | S&F PVC insulated and sheathed copper multistranded cable three core 1.5 sqmm, heavy duty through or on pole connecting to cable looping box of street light fitting complete in repair all as specified & directed. |
| 20 | S&F PVC insulated and sheathed copper multistranded cable three core 2.5 sqmm, heavy duty through or on pole connecting to cable looping box of street light fitting complete in repair all as specified and directed. |
| 21 | S&F two way heavy duty PVC connector suitable for 10 or 16 Sqmm cable connection in looping box complete in repair all as specified and directed. |
| 22 | S&F aluminium thimbles/lugs of size 10 to 25 Sqmm for cable connection as per site requirement complete in repair all as specified and directed. |
| 23 | S&F 90 watt LED roadway luminaire, made up of pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP66 protection with high power LEDs as light source and HF electronic driver of 90W capacity including making necessary connection complete in repairs all as specified and directed by Garrison Engineer. |
| 24 | S&F 75 watt LED street/roadway luminaire made up of pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP66 protection with high power LEDs as light source and HF electronic driver of 75W capacity including making necessary connection complete in repairs all as specified and directed by Garrison Engineer. |
| 25 | S&F LED flood light luminaire 250 watt with secondary optics made in pressure die cast housing and heat sink in aluminium extruction with IP66 protection complete in repairs, all as directed by Garrison Engineer. |
| 26 | S&F LED flood light luminaire 200 watt with secondary optics made in pressure die cast housing and heat sink in aluminium extruction with IP66 protection complete in repairs, all as directed by Garrison Engineer. |
| 27 | S&F LED driver suitable for 90 watt LED street light fittings complete in repair, all as specified and directed by Engr-in-Charge. |
| 28 | S&F CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 w, beam range 700 meters, Single, LED Efficiency > 140 lm/w, PF > 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency > 95%, multiple circuit to avoid complete run-down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, average lux at 5 meter - 15000 with circle of approx 600 mm, working temp : -20 to +60 degree C, input Volt 150-270 V, 50 Hz, P.F. > 0.95, IP-65, confirming to LM79/LM80 as per IS : 10322/ IS: 13383. The stand of this search light should be suitable for fixing on railing/platform of watch tower or other plain surface. It is made by steel and suitable for manual rotation of the light on the horizontally (more than 360 degree) and vertically (more than 45 degree) with provision of both locking arrangement at desired position complete in repairs, all as specified and directed. |
| 29 | Rectifying & attending the complaints of street / security / HML & other external lights of the station on daily basis as receipt of complaints by departmental staff with light fittings and connected items , the complaints to be rectified within 24 Hrs or else of penalty of Rs @ 800/- will be deducted per complaint complete all as directed by Engr- in - Charge. Note :- Light fittings & connected items will be measured & paid separately in respective items. |
| 30 | S&F in repairs aviation obstruction light with neon lamp yellow coloured die cast aluminium alloy housing, with built in 75 VA step up transformer complete all as specified and directed. |
| 31 | Supply, laying & testing PVC insulated, round sheathed cable electric control cable (Heavy duty) with stranded copper conductor (flexible) industrial cable of size 4 Sqmm, 5 core, 1100 V grade conforming to IS 694 fixed with PVC straps from control gear to fitting complete including taking down existing unserviceable cable all as specified and directed by Engr-in-Charge. |
| 32 | Earthing complete in repair with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nuts of steel/GI duly protected with 15mm bore light grade pipe upto main board, 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, char coal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified.Note :- The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15mm bore, RCC cover slabs 50mm thick with 8mm dia CTD bars @ 140mm c/c both ways etc complete. Please Enable Macros to View BoQ information |
| 33 | Earthing complete in repair with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nuts of steel/GI duly protected with 15mm bore light grade pipe upto main board, 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, char coal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified.Note :- The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15mm bore, RCC cover slabs 50mm thick with 8mm dia CTD bars @ 140mm c/c both ways etc complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender