Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #58021168

Tender For Rewiring Of Junior Commissioned Officers Mess And Accomodation With Provn Of Lt Panel And Cables At Hq Cif (R) Under Age (I) Cif (R)

Issued by Statutory Bodies & Commissions/Committees · Rajouri, Jammu and Kashmir
Tender Value
9.03 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
0 days left
EMD
18064
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Rewiring Of Junior Commissioned Officers Mess And Accomodation With Provn Of Lt Panel And Cables At Hq Cif (R) Under Age (I) Cif (R)

BOQ

Name of Work:- Rewiring of junior commissioned officers mess and accomodation with provn of LT panel and Cables at HQ CIF (R) under AGE (I) CIF (R)
Sl. No. Item Description
1Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc
2Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLSH) cable, 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLSH) cable for earth continuity wire, connected to earth dolly and in including modular pressed steel sunken boxes of required size with modular cover plate with frame for mounting modular switches, sockets, fan regulators etc including testing on completion, complete including cutting chases for concealed conduit piping in making good to disturbed surface and pointing in using cement mortar 1:3 all as specified and as directed for the following.
3One light/fan point controled by one 5/6 Amp modular type switch
4One 3 pin socket outlet 5 Amps on same board for modular type.
5One 3 pin socket outlet 5 Amps on indpendent board for modular type.
6All as per item No 2 here in before but point wiring with 2.5 sqmm FRLSH multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15/16 Amp switch on independat board, complete all as specified and directed.
7S&F in replacement of modular switch single pole one way 6 Amps 1 module complete all as specified and directed.
8S&F in replacement of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed.
9S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed.
10S&F in replacement of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed.
11S&F in replacement of ceiling rose polycarbonate type three terminals complete all as specified and directed.
12S&F in replacement of modular fan regulator, electronic step type heavy duty modular 2 module 230 volts, 120 watt complete all as specified and as directed.
13Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLSH) cable, 1100 Volts grade drawn through and including PVC casing/conduit of suitable size as per site requirement fixed to wall, ceiling including PVC closed recessed boxes ISI marked laminated sheet top cover plate complete for mounting of switches, sockets etc incl 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductor connected to common earth dolly all as directed and specified for the followings.
14One light /fan point controled by one 5/6 Amp for modular type.
15One 3 pin socket outlet 5 Amps on same board for modular type.
16One 3 pin socket outlet 5 Amps on indpendent board for modular type.
17All as per item No. 10 here in before but point wiring with 2.5 sqmm FRLSH multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15/16 Amp switch on independat board, complete all as specified and directed.
18Supply and fix in replacement Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings,all as specified.
19S&F in replacement LED lamp,6500K,900lm in white colour of 9/10 Wattbase cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed.
20S&F in replecement of Ultra slim LED light to new 28W, 6500 K LED (CDL/WW type as per site requirement) recess mounted bakelite panel of size 2 x 2 feet luminaire suitable for surface/grid ceiling for low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector including taking down old unserviceable luminaire, complete all as specified and as directed.
21S&F in replacment of LED tubelight fitting 1x20Watt batten type fitting 4 feet long aluminium extruded housing IP-20 rated rated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hz system wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, system lumen efficacy 100 lm /watt ,CCT 6500K complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75 sqmm 3 core all as specidfierd and directed.
22Supply & fix LED INVERTER batten 20 Watt, 4 feet long with square profile and polycarbonate channel. Lithium ion Battery with Charging time 8 hours-10 hours and back up time upto 4 hours and including removing old fittings all as specified and directed by Engr-in-Charge.
23All as per item No. 16 here in before but LED tubelight fitting 1x10Watt batten type fitting 2 feet long, complete all as specified and directed.
24S & F in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
25Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure diencast aluminum hosing and heat resistant complete with driver, lamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including bracket of suitable with clamps etc accessories.
26S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 6 sqmm cable and one run of 6.00 sqmm earth wire with PVC casing and caping shall be measured as one unit.
27S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as one unit.
28S&F in replecement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed. (for connection of separate Bathroom DBs etc.)
29S&F in replecement of SPN DB 4 Way, Sheet metal enclosure type, IP-43 double door for DBs (where MCBs are reqd) SPN 240 V, complete all as specified.
30S&F in replecement of SPN DB 6 Way Sheet metal enclosure type, IP-43 double door for DBs (where MCBs are reqd) SPN 240 V, complete all as specified.
31S&F in replecement of SPN DB 8 Way Sheet metal enclosure type, IP-43 double door for DBs (where MCBs are reqd) SPN 240 V, complete all as specified.
32S&F in replecement of SPN DB 12 Way Sheet metal enclosure type, IP-43 double door for DBs (where MCBs are reqd) SPN 240 V, complete all as specified.
33Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
34Supply & fix MCB SPN 40 to 63 Amps 10 KA,\\"C\\" series, AC, 240Volts,50Hz, ISI marked complete all as specified and directed.
35S&F in replecement of MCCB 100 Amp,4 pole, 16 KA, 415 volts 50Hz, AC supply, complete all specified.
36Supply and fixing in replacement of MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, VTPN 4 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB 63/100/125 Amps 4 pole, including grouting in the wall, cutting & chasing/surface mounting etc. complete all as specified.
37Supply and fixing in replacement of heavy duty PVC Switch Socket Combination box of capacity 20 Amps with MCB SP 20 Amps, 240 volts suitable for Split/window AC, including grouting in the wall, cutting & chasing/surface mounting etc. complete all as specified.
38M&L in replacement of earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cmX 6.0 mm buried in the ground to a depth not less than 2.25 mtr below ground level connected with GI wire 4 mm by means of GI nut, bolts, washers and check nut and complete as shown in electric plate No 03 of SSR Part-I including 20 mm dia GI pipe medium grade for watering, funnel and RCC cover including earth work for excavation and removal of surplus soil and making earth test point complete all as specified and directed.
39Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0 mm dia galvanised iron or steel wire
40Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including fiixing arrangement all as directed by engr-in-charge. (for Cook House)
41Supply and fix heavy duty exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers including making hole for fixing of exhaust fan all as specified and directed.
42M&L for taking down existing serviceable Geyser from bathroom of JCOs single living accn safely and refixing the same as previous location including new fastner assy all as specified and directed by engr-in-charge.
43M&L for taking down existing serviceable ceiling fans from JCOs single living accn safely and refixing the same as previous location including new anchoring/hanging arrangements all as specified and directed by engr-in-charge.
44M&L for taking down existing serviceable exhaust fans from locations of single JCO living accn safely and refixing the same duly cleaned as previous location including new fixing arrangements all as specified and directed by engr-in-charge.
45M&L for replacement of under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 185 Sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Earth work & connected works for laying of cable shall be measured and paid separately.
46All as per item No. 1 here-in-before but cross-sectional area 35 Sqmm, 3.5 core complete.
47All as per item No. 1 here-in-before but cross-sectional area 16 Sqmm, 2 core complete.
48M&L for GI pipe 80 mm dia \\"light grade\\" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .
49All as per Srl item No. 4 here-in-before but 50 mm dia
50All as per Srl item No. 4 here-in-before but 40 mm dia
51Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed.
52Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
53Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
54Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed.
55Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed
56M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
57M&L in replacement of 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for end joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 Sqmm.
58M&L in replacement of 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 Sq mm.
59Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 400 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (200 Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following. spares,accessories and parts:- (a) Change over 250 Amps, 4 pole, 415V, 50Hz, AC Supply. (b) MCCB 250 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (c) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 25 KA (Adjustable thermal & fixed magnetic release) - 02 Nos (Outgoing)(d) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 02 Nos (Outgoing) (e) MCCB 40 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Outgoing) Please Enable Macros to View BoQ information
60Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 400 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (200 Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following. spares,accessories and parts:- (a) Change over 250 Amps, 4 pole, 415V, 50Hz, AC Supply. (b) MCCB 250 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (c) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 25 KA (Adjustable thermal & fixed magnetic release) - 02 Nos (Outgoing)(d) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 02 Nos (Outgoing) (e) MCCB 40 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Outgoing) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58021168
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.03 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Rewiring Of Junior Commissioned Officers Mess And Accomodation With Provn Of Lt Panel And Cables At Hq Cif (R) Under Age (I) Cif (R)
Basic Detail
Tender No AGE(I)/R-71/2026-27
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 13 Oct 2026
Submission Date 03 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 9.03 Lakhs
Tender Fee 500
EMD 18064
Exemption Available
Document List
091455d4-d60c-4f41-8940-1434ac0056cf.html
BOQ_890119.xls
TenderDocument71.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

091455d4-d60c-4f41-8940-1434ac0056cf.html

xls

BOQ_890119.xls

pdf

TenderDocument71.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender