Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #58021154

Tender For Repair/Replacement/Maintenance Of External Electric System Including Service Connections, Replacement Of Lt Poles, Lt Panels, Earthings And Misc Work At Mil Stn Kanchrapara Under Ge Barrackpore

Issued by Statutory Bodies & Commissions/Committees · 24 Paraganas North, West Bengal
Tender Value
49 Lakhs
Estimated cost
Bid Submission
03 Nov 2026
1 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement/Maintenance Of External Electric System Including Service Connections, Replacement Of Lt Poles, Lt Panels, Earthings And Misc Work At Mil Stn Kanchrapara Under Ge Barrackpore

BOQ

Name of Work:- REPAIR/REPLACEMENT/MAINTENANCE OF EXTERNAL ELECTRIC SYSTEM INCLUDING SERVICE CONNECTIONS, REPLACEMENT OF LT POLES, LT PANELS, EARTHINGS AND MISC WORK AT MIL STN KANCHRAPARA UNDER GE BARRACKPORE
Sl. No. Item Description
1Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
2Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed.
3Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
4supply, erection and commissioning of steel tubular swaged poles simple/decorative type complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type LT type 410 SP-31, (9m long) including two coat of synthetic emulsion paint upto 1.2 m hight in black and yellow strips (as directed at site during painting) colour and there on synthetic enamel paint silver colour on steel surface such as complete pole, cross arms, brackets, MS flats, nuts, bolts and all accessories fixed on pole with excavation, earth work, PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation and coping of poles with PCC 1:2:4 type B1 (using 20mm graded stone aggregate) including dismantling of old pole complete all as specified and as directed.Note :- Excavation, earth work and concrete work complete not included in unit item and the same will be measured and paid under respective items.
5M&L for Stay assembly complete with 16mm dia Rod for standing a pole or support to any heavy eqpt/ Spare parts/ Heavy channel accessories etc as shown in electrical plate No. 1 diagram including loop type insulator, stay clamps, ,including all excavation/earth work in any strata and returning filling, removal of surplus soil, PCC 1:3:6 type C1 and 1:2:4 type B1 for required value complete all as per site requirement including dismantling of old stay assembly complete all as specified and as directed.Note : Earthwork, Cement Concrete, Loop Insulator etc. will be measured and paid under appropriate Items.
6M&L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed.
7M&L for PCC 1:3:6 Type C-2 ( Using 40mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed.
8M & L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in benching and coping, pole coping, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed.
9M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminuum paint over a coat of red oxide primer including dismantling of old cross arms complete all as specified and as directed.
10M&L for Galvanised Steel Wire 3.15 or 4.0mm dia as Earth Continuity Conductor and fixed to Pole binding with Aluminium Binding Wire including dismantling of old wire of any description complete all as specified and as directed.
11M&L for Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire requirement including dismantling of old Cradles complete all as specified and as directed.Note : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
12M&L for Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) conforming to IS-398 with permissible Sags and providing Jumper, etc., fixing on Electric Poles, stringing and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., and connecting of disconnected cable, service cable and street light connection including dismantling of old ACSR conductor complete all as specified and as directed. Note : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
13Labour only for Releasing/ restringing ACSR Conductor of existing OH Lines by un-binding from Insulator of any description, refixing after stretching, restringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire complete all as specified and as directed.Note : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
14S&F PVC/ Fiber Separator for LT Lines 1100 Volts OH Conductor 4 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc, including taking down old unserviceable one complete all as specified and as directed.
15M&L for insulators pin type LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, iron nut, 100 mm height, 65 mm dia including dismantling of old unserviceable insulator any type complete all as specified and as directed.
16M&L for shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised mild steel straps, washers, insulator bolts, nuts 14 mm dia, 100 mm height and 115mm dia, section of straps 31mmx5mm of insulator including dismantling of old unserviceable insulator any type complete all as specified and as directed.
17M&L for loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 90 mm x 65 mm, clearance of hole 16 mm suitable for 1100 volts including dismantling of old unserviceable insulator any type complete all as specified and as directed.
18M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from steel tubular Pole of size 9m (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 Nos consisting with Each Strip of 200 mm wide) from above coping and remaining portion of Pole treated with Two Coats of Aluminium paint and Mild Steel Cross Arms, etc. treated with Two Coats of two component aliphatic polyurethane based paint UV & weather resistant and Writing for Each pole Nos complete all as specified and as directed.
19M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from steel HT Pole of size 11m (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 Nos consisting with Each Strip of 200 mm wide) from above coping and remaining portion of Pole treated with Two Coats of two component aliphatic polyurethane based paint UV & weather resistant and Writing for Each pole Nos complete all as specified and as directed.
20Pruning / trimming of various sizes of tree branches which are touching/close to LT overhead line at various places and clear the LT overhead line upto 3mts from conductor close to tree along pole to pole and removing the same upto 150 m away complete all as specified and directed by Engr-in-Charge.Note: (a) All the safety equipments, cutting materials, ladder etc required for the above job shall be arranged by the contractor.(b) the Pole to Pole distance to be measured in span.
21Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 10 sqmm, 4 core, 1100 Volts (Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking out of old cable of any description complete all as specified and as directed.Note: - For item No 21 to 33. Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.
22All as per item No 21 here in above but for size 16 Sqmm 4 core complete all as specified and as directed.
23All as per item No 21 here in above but for size 25 Sqmm 3.5 core complete all as specified and as directed.
24All as per item No 21 here in above but for size 35 Sqmm 3.5 core complete all as specified and as directed.
25All as per item No 21 here in above but for size 50 Sqmm 3.5 core complete all as specified and as directed.
26All as per item No 21 here in above but for size 70 Sqmm 3.5 core complete all as specified and as directed.
27All as per item No 21 here in above but for size 95 Sqmm 3.5 core complete all as specified and as directed.
28All as per item No 21 here in above but for size 120 Sqmm 3.5 core complete all as specified and as directed.
29All as per item No 21 here in above but for size 150 Sqmm 3.5 core complete all as specified and as directed.
30All as per item No 21 here in above but for size 185 Sqmm 3.5 core complete all as specified and as directed.
31All as per item No 21 here in above but for size 240 Sqmm 3.5 core complete all as specified and as directed.
32All as per item No 21 here in above but for size 300 Sqmm 3.5 core complete all as specified and as directed.
33All as per item No 21 here in above but for size 400 Sqmm 3.5 core complete all as specified and as directed.
34Taking down of underground cable any type size for carrying any repair and relaying the cable back in trenches/through pipe in road crossing/path/drain/ ducts floors/along pole/walls celling/equipment etc complete all as specified and as directed. Note: (i) Necessary excavation and earth work will be measured and paid separately. (ii) Brick protection, sand cushioning and cover and GI pipe if required shall be measured and paid for separately.
35M & L for sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 cm (15cm under the cable and 8 cm over the cable) and gently punned down to 18cm thickness, complete all as specified and as directed. Note: Only punned down sand shall be measured.
36M & L for old size clay burnt bricks class 'B' type laid dry width wise across the line of cable in trenches for protection of underground cable complete all as specified and as directed.
37M& L for manual boring under roads/hard standing using required T&P without disturbing the top surface of the road (minimum 1.0 Mtr below the road surface), inserting GI pipe n exc 80 mm dia for cable protection complete all as specified and as directed. Note : - GI pipe will be measured & paid separately.
38Supply and laying GI tubing 40mm bore medium grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed.
39Supply and laying GI tubing 50mm bore medium grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed.
40Supply and laying GI tubing 80mm bore medium grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed.
41M& L for heat shrinkable straight through type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 25 Sqmm to 50 Sqmm 3.5 or 4 Core complete all as specified and as directed.
42M& L for heat shrinkable straight through type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 70 Sqmm to 150 Sqmm 3.5 or 4 Core complete all as specified and as directed.
43M& L for heat shrinkable straight through type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 185 Sqmm to 240 Sqmm 3.5 or 4 Core complete all as specified and as directed.
44M& L for heat shrinkable straight through type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 300 Sqmm to 400 Sqmm 3.5 or 4 Core complete all as specified and as directed.
45M& L for heat shrinkable indoor/outdoor end terminals type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 25 Sqmm to 50 Sqmm 3.5 or 4 Core complete all as specified and as directed
46M& L for heat shrinkable indoor/outdoor end terminals type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 70 Sqmm to 150 Sqmm 3.5 or 4 Core complete all as specified and as directed
47M& L for heat shrinkable indoor/outdoor end terminals type cable joint kit, for 1.1 KV epoxy PVC /XLPE cable with all jointing materials & accessories suitable for cable of size 185 Sqmm to 300 Sqmm 3.5 or 4 Core complete all as specified and as directed
48S&F copper cable 10 sqmm single core , fixing in LT panel from bus bar to switch gear as connector lead with suitable copper lugs complete all as specified and as directed.
49S&F copper cable 16 sqmm single core , fixing in LT panel from bus bar to switch gear as connector lead with suitable copper lugs complete all as specified and as directed.
50S&F insulated copper bus bar of size 40 X 10 mm for any size of existing LT panel including taking out of burn bus bar complete all as specified and directed.
51S&F insulated Aluminium bus bar of size 32 X 6 mm for any size of existing LT panel including taking out of burn bus bar complete all as specified and directed.
52S&F Aluminium lug 10-16 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc complete all as specified and as directed.
53S&F Aluminium lug 25 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
54S&F Aluminium lug 35 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
55S&F Aluminium lug 50 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
56S&F Aluminium lug 70 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
57S&F Aluminium lug 95 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
58S&F Aluminium lug 120 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
59S&F Aluminium lug 150 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
60S&F Aluminium lug 300/400 sqmm in existing panel or LV side of distribution panel, feeder pillar box, junction box etc with help of pressure crimping tool complete all as specified and as directed.
61S&F UG cable route indicator made out of PCC minimum grade M-15 (using 20 mm graded crushed stone aggregate) of size 45 x 30 x 10 Cm blocks, writing MES, direction of cable, class/voltage rating for LT 1100 Volts complete all as specified and as directed.
62S&F in repairs, MCCB 4 pole 63 Amps of breaking capacity 25 KA Conforms to IS/IEC 60947-2, thermal adjustable overload settings: 0.8 - 1.0 x In, Ics=100% Icu suitable for 415 volts, 50 Hz, with extended terminal fixed in existing LT Panel complete all as specified and as directed.
63S&F in repairs, MCCB 4 pole 100 Amps of breaking capacity 25 KA Conforms to IS/IEC 60947-2, thermal adjustable overload settings: 0.8 - 1.0 x In, Ics=100% Icu suitable for 415 volts, 50 Hz, with extended terminal fixed in existing LT Panel complete all as specified and as directed.
64S&F in repairs, MCCB 4 pole 160 Amps of breaking capacity 25/36 KA Conforms to IS/IEC 60947-2, thermal adjustable overload settings: 0.67 - 1.0 x In and circuit settings 6 - 12 x In, Ics=100% Icu suitable for 415 volts, 50 Hz, with extended terminal fixed in existing LT Panel complete all as specified and as directed.
65S&F in repairs, MCCB 4 pole 200 Amps of breaking capacity 36 KA Conforms to IS/IEC 60947-2, thermal adjustable overload settings: 0.67 - 1.0 x In and circuit settings 6 - 12 x In, Ics=100% Icu suitable for 415 volts, 50 Hz, with extended terminal fixed in existing LT Panel complete all as specified and as directed.
66S&F in repairs, MCCB 4 pole 250 Amps of breaking capacity 36 KA Conforms to IS/IEC 60947-2, thermal adjustable overload settings: 0.67 - 1.0 x In and circuit settings 6 - 12 x In, Ics=100% Icu suitable for 415 volts, 50 Hz, with extended terminal fixed in existing LT Panel complete all as specified and as directed.
67S&F in repairs, ACB 4 pole 630 Amps, 50Hz, 415V, 50KA, thermal magnetic type fix in existing LT Panel with extended terminals type, interlocked to prevent opening when the Switch is in ON Position, confirming to 8536, high mechanical and electrical operating life protection through thermal magnetic DN-1 and connecting and testing complete all as specified and as directed.
68Supply, installation, testing and commissioning LT Feeder pillar box CPRI approved and Tested of Size 1000 x 800 X 500 mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet with angle iron frame of size 50 x 50 x 6mm cubical type complete with copper bus bar 400Amp (40x10) including dismantling of old feeder pillar box to accommodate to the following.INCOMING(a) MCCB 4 pole 250 Amp 36KA Icu = 100%Ics - 01 No (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING(a) Through Bus Bar
69M&L for taking out of the unserviceable panel indicators and allied accessories viz. Ammeters, voltmeters, frequency meters, selector switch, CTs, protective fuses, Neon indicator lamps etc. carefully and keeping in safe custody for replacement / disposal including cleaning of busbar replacement of copper/aluminium thimbles making suitable spaces for fixing of MCCB/Panel meters by cutting and welding suitable as per site duly painted with 2 coats of red oxide paint over a coat of primer after complete removal of paint complete all as specified and directed
70S&F in replacement 3P LED Digital Ammeter 96 x 96 mm class I input voltage range 50 to 520VAC complete all as specified and as directed.
71S&F in replacement 3P LED Digital Voltmeter 96 x 96 mm class I input voltage range 50 to 520VAC complete all as specified and as directed.
72S&F in repairs, CT for measuring AC on LT 3 phase system, 1.1 kv grade, single burden, general purpose as per site requirement complete all as specified and as directed.
73S&F in repairs, LED Indicator Lamps for phases flicker type including holders and of colours red / yellow / green / blue etc complete all as specified and as directed.
74S&F in repairs, Bakelite kit kat fuse base upto 32A rating with fuse holder complete and all as directed.
75S&F in repairs, Selector Switch (cam type) suitable for Ammeter / Voltmeter complete all as specified and as directed.
76S&F danger notice plate of size 20 x 15cm made out of 1.6 mm thick mild steel sheet vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for LT poles, including taking out old unserviceable danger notice plate complete all as specified and as directed.
77Disconnecting the worn out cable of size upto 50 sqmm to 400 sqmm from main control panel/Lt OH line cutting worn out portion and reconnecting with control panel/LT OH line with fixing of aluminium cable lugs of required size including excavation work for taking out cables from loop complete all as specified and as directed.
78Supply, installation, testing and commissioning LT panel box/ board of size 1.3 x 1.00 x 0.5 mtr suitable for The panel shall be dust and vermin proof, IP65 class protection and 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with Copper bus bar 400 Amp (30x10) powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English including dismantling of old panel box complete all as specified and directed. The scope of work includes the following items accommodate the same panel:- INCOMING(a) MCCB 4 pole 315 Amp 36 KA Icu = 100%Ics - 01 No (b) Digital Ammeter with selector switch and CT's (0-400) - 01 Nos.(c) Digital Volt meter with selector switch 0-500 Volt - 01 No (d) ON - OFF indicating lamp with toggle switch - 03 Nos. OUTGOING(a) MCCB 4 pole 63 Amp 25 KA - 02 Nos. (b) MCCB 4 Pole 125 Amp 25 KA-02 No (C) MCCB 4 Pole 100 25 Amp 25 KA -01
79Supply, installation, testing and commissioning LT panel box/ board of size 1.3 x 1.00 x 0.5 mtr suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with Aluminum bus bar 400 Amp (40x10) powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English including dismantling of old panel box complete all as specified and directed. The scope of work includes the following items accommodate the same panel:-INCOMING(a) MCCB 4 pole 250 Amp 36 KA Icu = 100%Ics - 01 No (b) Digital Ammeter with selector switch and CT's (0-400) - 01 Nos.(c) Digital Volt meter with selector switch 0-500 Volt - 01 No (d) ON - OFF indicating lamp with toggle switch - 03 Nos. OUTGOING(a) MCCB 4 pole 125 Amp 25 KA - 01 No. (b) MCCB 4 pole 63 Amp 25 KA - 03 No.
80M & L for disconnection of electric connection from LT Panel and shifting to new location not exceeding more than 25m from existing location including necessary foundation and electric connection and testing on completion complete all as per specified and as directed.
81M&L for Shifting of diesel generator set 125 KVA to 200 KVA capacity from substation to substation within 1-6 KM distance complete all as per specified and directed by Eng in charge.
82S&F of galvonised mild steel strip 25 mm x 4 mm for earthing complete with saddles and fixing screws for fitting the strip for earth continuity conductor up to test points including taking out old strip complete all as specified and directed by Engr-in-charge.
83S&F in repairs, 6 mm steel wire rope ASIS 326 grade of high mast lighting system of height 10 to 15m all T&P items on arrangement of Contractor complete All as specified and as directed.
84M&L for mobile servicing of motor/heat varnishing, chain, pully, 10 to 15 m High mast lighting system and greasing/overhauling complete all as specified and as directed.
85S&F in repairs, Modular Four pole on load changeover switch with advanced neutral having current rating 250 Amp with phase barrier & handle with door interlock kit in Sheet Metal Enclosure complete all as specified and as directed.
86S&F in repairs, Modular load change over switch 100 amps, 440 Volts in sheet metal enclosure 4 pole complete all as specified and as directed.
87S&F in repairs, Modular Four pole on load changeover switch with advanced neutral having current rating 400 Amp with phase barrier & handle with door interlock kit in Sheet Metal Enclosure complete all as specified and as directed.
88M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to GI strip 32mmx6mm upto 7.5 metre by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate), excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion complete all as specified and shown on plate No 3 of SSR Part-I 2009 including dismantling of old earthing complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58021154
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 03-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement/Maintenance Of External Electric System Including Service Connections, Replacement Of Lt Poles, Lt Panels, Earthings And Misc Work At Mil Stn Kanchrapara Under Ge Barrackpore
Basic Detail
Tender No 8300/E8
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 13 Oct 2026
Submission Date 03 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
92da4200-6065-4b5c-a704-f08effcb3945.html
BOQ_890184.xls
Tenderdoc_8300.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

92da4200-6065-4b5c-a704-f08effcb3945.html

xls

BOQ_890184.xls

pdf

Tenderdoc_8300.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender