Tender For Civil Works For Construction Of Cable Trench And Pathway At Balar Ur 33/11 Kv Sub-Station For Bifurcation Of Burirhat 11Kv Feeder By Creation Of A New 11Kv Feeder Emanating From Balar Ur 33/11Kv Substation With Erection Of 6.611Ckm Of Htoh
Tender Overview
Project Description
Tender for Civil Works For Construction Of Cable Trench And Pathway At Balar Ur 33/11 Kv Sub-Station For Bifurcation Of Burirhat 11Kv Feeder By Creation Of A New 11Kv Feeder Emanating From Balar Ur 33/11Kv Substation With Erection Of 6.611Ckm Of Htoh Line From Balakura Natun Bazar To Khatamari Ghoshpara Under Dinhata Division, Wbsedcl.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 3 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 4 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, etc. NOTE: Cement 0.152 cu.m. per sq.m. |
| 5 | (II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. VarietyIn ground floor and foundation.(A) Stone metal.(a) 6:3:1 proportion |
| 6 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(f) 25mm. to 30mm. shuttering without staging in foundation etc. |
| 7 | Labour for Chipping of concrete surface before taking up Plastering work. In ceiling, beam sides & soffit, column faces, staircase etc. |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bennding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor / upto 4m.(i) Tor steel/Mild steelII)JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL In Ground Floor and Foundation. |
| 9 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips(20 mm.nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.b) River bazree. In Ground Floor and Foundation. |
| 10 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.](i) With 1:6 cement mortar (c) 15 mm. thick plaster. For Outer walls. In ground floor. |
| 11 | M.S structural works in columns ,beams etc. With simple rolled strual members (e.g. joists, angle, channel sections conforming to IS:226, IS:808 & SP (6)1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with neceassry bolting metal arc welding conforming to IS:816-1956 and IS:1995 using electrodes of approved make and brand conforming to IS:814-1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.I) For structural members of specified sections weighing less than22.5 Kg./m Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline