Tender For Development, Beautification, Decorative Illumination And Comprehensive Maintenance Of Welcome Prayagraj Elevation At Shastri Bridge,Prayagraj
Tender Value
1.01 Crore
Estimated cost
Bid Submission
05 Nov 2026
6 days left
EMD
2.04 Lakhs
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development, Beautification, Decorative Illumination And Comprehensive Maintenance Of Welcome Prayagraj Elevation At Shastri Bridge,Prayagraj
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of state-of-the art laser-cut / glowing & embellished panels, laser-cut metal sheet cladding for the entire height of columns up to & the ceiling, including both sides and back wall of the face of the underpass. Fitted with LED lighting with electronic driver having protection against short circuit, over-voltage and over current, IP65 protection, AC 240V input, estimated lifetime L70 ≥ 50,000 hours minimum, Mounting arrangement with foundation plate, final design as per reference image and approved by the Engineer-in-Charge. |
| 2 | Supply, installation, testing & commissioning of 5mm polycarbonate sheets of approved colour with diffused light. Sheets shall be high-impact resistant (IK10), anti-scratch, anti bacterial, anti-fog, durable for harsh environments, and resistant to sunlight, weather and most chemicals. |
| 3 | Supply, installation, testing and commissioning of LED flood light, 50W mould-spot flood luminaire for façade lighting with die-cast aluminium housing, powder coating of wattage 75W-85W. Medium beam angle; high optical efficiency with PMMA/PC lenses. Luminaire complete with driver and capable of operating at line voltage without separate power supply from 120 to 270V AC, 50 Hz, power factor >0.9. Life of fixture (including driver) ≥ 50K hrs. Protection minimum IP66 and IK07, IEC Class I, RoHS compliant, BIS certification and 5 years warranty for luminaires & drivers. Installation/accessories complete as approved by Engineer in Charge. |
| 4 | SITC of LED WW 50-60W linear wall washer luminaire for façade lighting with aluminium extruded housing, complete with driver and capable of operating at line voltage without separate power supply from 100 to 270V AC, 50Hz, power factor >0.9. Suitable for ambient temperature range -10°C to +50°C and IP66/IK08 rated. Life time at least L70: 50,000 burning hours at 50°C. Complete with necessary accessories and wiring, including proper working of fixture with waterproof connectors etc. |
| 5 | Supply and laying of 4.0 sq.mm x 3 core ISI marked, FRLS PVC insulated, single core copper conductor cable in existing conduits with proper connections, glands, etc. |
| 6 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable shall be fixed on M.S. clamps etc. of suitable size or as directed by Engineer-in-Charge, complete in all respect. The armouring of cable shall be properly connected with earth conductor by clamps etc., 25 q.mm 3-1/2 core. |
| 7 | Supplying and fixing of surface/recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A 4-pole tinned copper bus bar, common neutral link, earth bar, din required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required), 4-way (4+12), double door. |
| 8 | Supplying and fixing of surface/recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A 4-pole tinned copper bus bar, common neutral link, earth bar, din required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required), 8-way (4+24), double door. |
| 9 | Supplying and fixing of surface/recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A 4-pole tinned copper bus bar, common neutral link, earth bar, din required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required), 8-way (4+36), double door. |
| 10 | Supply and fixing IP67 weatherproof box for Power Supply with cable glands and output of the box; size shall be sufficient to accommodate the power supply of the fixtures. |
| 11 | ENCAPSULATED PIPE - IN- PIPE EARTHING: Supply and burning of Safe Earthing Electrode T 19 Zn-Zinc Coated, length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron mixed with crystalline conductive mixture (CCM) having high corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 sq.mm Cu GI frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra). Make: As approved in U.P. P.W.D., C.P.R.I. Certified. |
| 12 | Supply, installation, testing and commissioning of stand mounted panel made of 16 SWG GI sheet, double door and duly pretreated and powder coated to make it weather proof. Astronomical timer MCCB 65A, switch 3 pole TPN. |
| 13 | Supplying and drawing following sizes of FRLS PVC Insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required: 1 x 1.5 sq.mm. |
| 14 | Operation & maintenance of 2nd year (2% of total estimated cost). |
| 15 | Operation and maintenance 3rd year (3.25% of total estimated cost). |
| 16 | Operation and maintenance 4th year (4% of total estimated cost). |
| 17 | Operation and maintenance 5th year (4.25% of total estimated cost). |
| 18 | LED signage laser cut acrylic or stainless steel raised letters with ACP base waterproof IP67 Technology all in complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender