Housing Urban and Rular Development Local Bodies Closing in 9 days TDR #58020091

Tender For maintenance of Park Light (Annual Maintenance And Strengthing Of Park Light In Meghdutam Park Sector-50 & Childern Park Sector-51), Noida

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
74.63 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
9 days left
EMD
1.49 Lakhs
Bank guarantee accepted
Document Fee
2832
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of Park Light (Annual Maintenance And Strengthing Of Park Light In Meghdutam Park Sector-50 & Childern Park Sector-51), Noida

BOQ

Name of Work:- M/O Park Light (Annual Maintenance and Strengthing of Park Light In Meghdutam Park Sector-50 & Childern Park sector-51), NOIDA
Sl. No. Item Description
1Supply , Installation , testing and commissioning of standard 4.0 Mtr. High (above ground) hot dip galvanized (grading of galvenisation average 70 micron or better as per IS 2629 or equivalent) pole, with stiffener, chain, allen bolt, foundation, single arm bracket, template, nut and bolts galvanized, factory finish base plate of size 200x200x12mm etc complete as required. The pole shall be made of 3mm thickness sheet with tolerance of +/- 5%. The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening, a junction/loop box with heavy duty 3 phase , 32 Amp. connector with 16A DP MCB including all accessories complete as required derected by E/I.(Make - Bajaj/Valmont/Transrail)
2S/Fixing of LED Street Light fitting having die cast Aluminium body and difuser with driver set suitable for 52 to 72 watt. Confirming to IP-66 and above protection. Complete in all respects. (PS No. 1422) Cat-AAA (Make-LT/Philips/Wipro)
3Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Polycab, KEI, Havell's make)
4(1) 16 Sq.mm. x 4 Core (PS No. 501)
5(2) 50 Sq.mm. 3.5 Core (PS No. 501)
6S/F of Palm or Pin type copper tin plated cable socket (lugs) to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504
71- 16 sq. mm
83- 25 sq. mm
94- 50 sq. mm
10Supply and fixing of 40 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807F
11Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kind of soil.DSR 2.6.1 (Rate as per TAC order)
12Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. 2.25/P-67 (Rate as per TAC order)
13Supply and making straigth through joint with cast resin compound including ferrules and other joints material for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required (Electrial DSR-2014, Item No. 9.3 P-32)
14a) 2x16 sq. mm ((Electrical DSR-18/Ite. No. 9.3.1 pg.34)
15S/Laying of 63 mm dia (OD 63 mm & ID 51 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench or Trenchless method if required but excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/Time/CPE make. as per DSR 2018 item no. 14.16.1 page no. 49
16Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (DSR civil I No. 15.2.1/P-258)
17Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
18Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. as per PS No. 628
19Supply and fixing of LED Tube Light with batten suitable for upto 1x22 watt LED Tube Light fitting including tube on surface. Complete in all respects (PS No. 1413 CAT-AA) (Make-LT/Bajaj/ Havells/ Crompton/ Philips/Wipro)
20Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.. Complete in all respects (PS No. 1402 CAT-AA) (Make-LT/ Bajaj/ Havells/Crompton/Philips/Wipro)
21Dismantling of pole/Street Light standard /strut embedded in cement concrete foundation etc. as required (DSR-2018/item no. 12.42 P-46)
22Supply and buring of safe earthing electrode T-19 (Hot dip galvanized), length up to 3000mm outer type 50mm, inner pipe, 25mm terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystalline conductive mixture(CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good micture of retaining capicity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra as per PS No. 725B
23S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-29
24185 Sq.mm.
25S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS & complete as per the direction and satisfaction of E/I (Raychem, Denson, Cabseal Make) UPERC 2019 Pg-29
26Providing and laying of Kota stone slab flooring over 20mm(average) thick base laid over and jointed with grey cement siurry mixed with pigment to match the stone of the slab, including rubbing & polishing complete with base of cement mortar 1:4 (1 cement 4 coarse sand) as per approved of E/I(AOR)
27Providing and laying of 40 mm thick fine dressed stone flooring over 20mm(average) thick base laid of cement mortar 1:5 (1 cement 5 coarse sand) including pointing with cement mortar 1:2 (1 cement 2 stone dust) with an admixture of pigment to match the shade of stone red sand stone as per approved of E/I(AOR)
28Wiring point for light in 1.5 sq. mm. .FRLSH PVC insulated multistrand single core copper conductor cable (drawn through existing PVC conduit), with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conducter cable as earth wire and 5 Amp.flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/ junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directed at site by the Engineer in charge. (PS No. 174 (C)
29Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge.(as per PS No. 291C)
30S/F of SP MCB 6 Amp to 32 Amp C-curve type Havells make 10 KA complete in all respect PS No. 1002 (Cat-B) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58020091
AUTHORITY Local Bodies
TENDER VALUE 74.63 Lakhs
LAST DATE 27-10-2026
Authority
Authority Name New Okhla Industrial Development Authority
Work Description Tender for maintenance of Park Light (Annual Maintenance And Strengthing Of Park Light In Meghdutam Park Sector-50 & Childern Park Sector-51), Noida
Basic Detail
Tender No 63/GM(E/M)/SM(E/M)-III/2026-27
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 14 Oct 2026
Submission Date 27 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value 74.63 Lakhs
Tender Fee 2832
EMD 1.49 Lakhs
Exemption Not Available
Document List
240508b7-7281-4ac7-9a63-55986ef043c0.html
BOQ_2259516.xls
C.xls
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

240508b7-7281-4ac7-9a63-55986ef043c0.html

xls

BOQ_2259516.xls

xls

C.xls

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender