Tender For Annual Maintenance And Repairing Of 16Mtr./30Mtr. Highmast In Sector-80, 81, 83, 84, 85, 86, 87, 88, 89, 90, 145, 146, 147 And 148, Noida.
Tender Value
48.85 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
9 days left
EMD
97800
Bank guarantee accepted
Document Fee
2124
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance And Repairing Of 16Mtr./30Mtr. Highmast In Sector-80, 81, 83, 84, 85, 86, 87, 88, 89, 90, 145, 146, 147 And 148, Noida.
BOQ
| Sl. No. | Item Description |
| 1 | BOQ (A)- R/o High MastSupply and fixing of Mast Nut, Bolt & templates suitable for 30 Mtr High mast. Complete in all respects as per directiion of E/I.(AOR) |
| 2 | Supply and fixing of Winch Machine assembly suitable for 30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 3 | Supply and fixing of SS Rope Wire 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 4 | Supply and fixing of Lantern Carriage made of 2.5\\" outer dia G.I. Pipe Class B heavy duty for mounting the luminaries suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 5 | Supply and fixing of Head Frame with Pulley suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 6 | Dismantling of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. (AOR) |
| 7 | Fixing of 30 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. (AOR) |
| 8 | Dismantling of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. Complete in all respect . As per direction of E/I. (AOR) |
| 9 | Fixing of 16 Mtr Height High Mast with the help of Crane/Hydra and required labour T&P etc. on existing foundation. Complete in all respect . As per direction of E/I. (AOR) |
| 10 | Supply and fixing of Window Door/Cover size as per 16Mtr/30 Mtr High mast made of 3mm thick MS Sheet with 2 Nos heavy duty lock shutter type incl. hinged. Complete in all respects as per directiion of E/I. (AOR) |
| 11 | Supply and fixing of fibre Junction Box suitable for 16Mtr/30 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 12 | Supply and fixing of Mast Nut, Bolt & templates suitable for 16 Mtr High mast. Complete in all respects as per directiion of E/I. (AOR) |
| 13 | Supply and fixing of Winch Machine suitable for 16 Mtr High mast. Complete in all respects as per directiion of E/I.(AOR) |
| 14 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR Electricals 2025 No. 11.3a) 4 X 16 sq. mm DSR 11.3.29 |
| 15 | e) 3.5 X 70 sq. mm (11.4.20) |
| 16 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing with toughend glass/UV stabilized PC Cover and lenses built with mandatory driver set suitable for 170 to 200 Watt. Confirming to IP 66, IK 07 and above protection complete in all respect including Labour.20400-24000 system Jumens, High power LED with lenses, >120 Lm/W, P.F>0.95, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (Not Circuitory) Phase to phase Protection at 440V & >300V auto cut and re-start feature, 4 KV internal Surge Protection, with 5 years warrantee18700-22000 system lumens, Mid power LED with lenses, >110 Lin/W, P.F.>0.95, THD <10% at full load, CRI >70, Potted driver Set (Not Circuitory), with 3 years warrantee Confirming to IP 66 protection complete in all respect .CAT- AAA PS No 23.26 |
| 17 | Supplying and laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade in Existing RCC/ Hume/Metal Pipe as directed by the Engineer-Incharge, complete in all respects including excavation and refilling .the armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2024, Item No.20b.1 Make-Grandlay, Havells,Dicab, Polycab, Gloster |
| 18 | a)- 16 sq. mm 4 core |
| 19 | b)- 50 sq. mm 3.5 core |
| 20 | Supply and fixing of Aluminium Lugs complete in all respect as per direction of the Engineer-Incharge. DSR 2025 |
| 21 | i)50Sqmm DSR 2025 item no. 2206 |
| 22 | ii) 16Sqmm DSR 2025 item no. 2203 |
| 23 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, ouplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 90 mm dia)D.S.R 2025 15.16.2 |
| 24 | a) 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 25 | Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt ) as required.D.S.R 2025 Item No.5.4 |
| 26 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. DSR Electrical - 2025 Item No. 13.38 |
| 27 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 28 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by expert technical staff. (AOR) |
| 29 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 30 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.DSR-2025 Item No.15.6 |
| 31 | M.S. Strip (50x6mm ) Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2025) pg-63 |
| 32 | BOQ -(B) R/o Transformer Supplying and laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade in Existing RCC/ Hume/Metal Pipe as directed by the Engineer-Incharge, complete in all respects including excavation and refilling .the armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2024, Item No.20b.1 Make-Grandlay, Havells,Dicab, Polycab, Gloster |
| 33 | 1) 50 sqmm x 3.5 core Item no..20a.1.12 |
| 34 | 1)70 sqmm x 3.5 core Item no..20a.1.12 |
| 35 | Supply and fixing of Aluminium Lugs complete in all respect as per direction of the Engineer-Incharge. DSR 2025 |
| 36 | 1) 50 sqmm DSR 2206 pg- 331 |
| 37 | 2) 70 sqmm DSR 2207 pg -331 |
| 38 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, ouplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 90 mm dia (OD-90mm & ID-76 mm nominal)D.S.R 2025 15.16.2 |
| 39 | Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt ) as required.D.S.R 2025 Item No.5.4 |
| 40 | Supply of Steel tubular pole 11 mtrs long designated at 410-sp 56 including excavation back filling etc complete in all respects UPERC 2025 P-38 |
| 41 | Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (DSR 2025 I. n. 12.3.4) |
| 42 | Repair of 63 KVA Transformer incl. changing of HV & LV Coil, Bushing, Gasket & Fresh Transformer oil without returning of old & unservicable material. Complete in all respect as per direction of E/I. (AOR) |
| 43 | Dis/Re-fixing of 63 kva transformer with connection loading & unloading, cartage charge from site to repairing at worshop complete in all respects as per direction of E/I (AOR) |
| 44 | S/F of 11 KV TPMO Relco/Rama make 9 Nos. insulator of jai Shree/BHEL make complete in all respects as per direction of E/I. UPERC P-48 |
| 45 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I..(AOR) |
| 46 | S/F of straight MS Channel 50x100mm 9.2 per kg 1.15 Mtr. Long including S/E of suitable clamp made of MS Flat 50x6mm including all nuts and bolts etc. complete in all respects as per direction of E/I. UPERC 2025 P-58 |
| 47 | S/F of straight MS Channel 50x100mm 9.2 per kg 2.24 Mtr. Long including S/E of suitable clamp made of MS Flat 50x6mm including all nuts and bolts etc. complete in all respects as per direction of E/I. UPERC 2025 P-34 |
| 48 | S/f of 11 KV Polymeric Disc insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on ht pole BHEL/ Jai shree / WS/RR make UPERC 2025 P No 38/ I No 9 |
| 49 | S/F of 11 KV polymeric Pin insulator of including all T/P. complete in all respects as per direction of E/I. UPERC-2025 P- |
| 50 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 51 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.DSR-2025 Item No.15.6 |
| 52 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. DSR Electrical - 2025 Item No. 13.37 |
| 53 | Supply of 01 nos Electrician & 1 Nos helper for maintenance c.for 12 month (34241+25270=59511 as per order No. Noida / GM(civil) /WC-1/ 2026/ 3055 /Dt 21.01.2026 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender