Drinking Water Supply and Sanitation Government Departments Closing in 23 days TDR #58012841

Tender For Installation Of Of Santoshpur-Ii Special Midi Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga(A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 202

Issued by Government Departments · Hooghly, West Bengal
Tender Value
48.28 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
23 days left
EMD
96570
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of Of Santoshpur-Ii Special Midi Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga(A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 2026-27 Programme In The District Of Hooghly

BOQ

Name of Work:- INSTALLATION OF OF SANTOSHPUR-II SPECIAL MIDI RLI SCHEME ( INCLUDING SUPPLY AND DELIVERY OF ALL RELATED MATERIALS , ALL-IN-ONE WORKS ON TURN KEY BASIS ) UNDER CH ADANGA(A-M) SUB DIVISION UNDER CHINSURAH (A-M) DIVISION UNDER CORE SECTOR 2026-27 PROGRAMME IN THE DISTRICT OF HOOGHLY
Sl. No. Item Description
1Supply & Delivery of Materials: Supply of 200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
2Supply of 140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
3Supply of 140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
4Supply of 200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
5Supply of 140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
6Supply of 200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
7Supply of 160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
8Supply of 160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
9Supply of 200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
10Supply of 200 X 160 mm P.V.C. Reducer (Class-II)
11Supply of 200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
12Supply of 140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
13Supply of 140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
14Supply of 200 mm dia P.V.C. End Cap(Cl-III)
15Supply of 140 mm dia P.V.C. End Cap(Cl-III)
16Supply of 200 mm dia P.V.C.Extra Coupler (Class-II)
17Supply of 140 mm dia P.V.C.Extra Coupler (Class-II)
18Supply of 160 mm dia P.V.C.Extra Coupler (Class-II)
19Supply of Solvent Cement(Extra)
20GI Quadrupped Set for Midi RLI Scheme, All material ISI marked (As per appvd. existing drawing & tech. spec.)
21150 mm dia 90º G.I Bend (both end flanged), one end flange welded and other end ring welded with bracking flange ISI marked-IS-1239, Galv- IS 4736 (As per appvd. existing drawing & tech. spec.)
22100 mm dia 90º G.I Bend (both end flanged) long bend With priming arrangement, ISI marked-IS-1239, Galv- IS 4736 (As per appvd. existing drawing & tech. spec.)
23100 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736(As per appvd. existing drawing & tech. spec.)
24150 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736 (4.8mm)(As per appvd. existing drawing & tech. spec.)
25Supply & transport of MS Kiosk Box of size 72\\" X 48\\" X 30\\" made with 16 gauge ms sheet fitting and fixing by running welding on (50 X50X6) angle with painting complete as per direction of EIC.
26Supply and transport of 20 HP Motor cover of size 600 x 600 x 700mm made with 25 x 25 x 5mm angel 2mm thick M.S. sheet with 4 Nos. Handle and Locking arrangement and fitting and fixing by running welding with painting complete as per drawing and direction of EIC.
27150 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846 (As per appvd. existing tech. spec.)
28100 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846 (As per appvd. existing tech. spec.)
29150 mm dia (type-C) Alfa Alfa Valve (nipple type) with handwheel 01 no. for 04 nos valve, as per IS 210/2009 (As per appvd. existing drawing & tech. spec.)
30Supply & Transportation of 100 mm dia C.I. Foot valve, flanged end & swing type. The disc face will be made of leather and strainer made of galvanized steel.The Valves shall be tested for (closed end test) against Hydrostatic test requirement
31Supply & Transportation of 100 mm dia MS Heavy Duty Hose Clamp fitted with bolts & nuts (2 sets), 2 mm thick, 30 mm width. One coat of Black Japan
32Supply & Transportation of MS Hose Clamp150 mm dia (45 mm thick, 2 mm width)
33Supply of C.I. Flanged Tail piece/Nipple150 mm dia.Tail piece one end flanged other end grooved.
34Supply & Transportation of 100 mm dia C.I. Tail Piece with one end flanged and other end grooved, overall length (175+/-15) mm. (23 mm flange thk) with 7 nos. grooves.
35Supply & Transportation of Foundation Bolt, manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 +10 mm having welded head 80 +10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.5 kg. per bolt with tolerance in weight of each bolt @ +10%.
36For Electro motor Pump Sets
37Supply & Transportation of GI Hexagonal Head Nuts and Bolts conforming to IS 1363(Part-I)/1992 of product grade C with latest amendmends for Bolts & IS 1363(Part-3)/1992 of product Grade-C with latest amendments for Nuts properties /Class for Bolt-4.6 & for Nut-4.5. ISI marked.a) M 16 mm X 65 mm.
38c) M 16 mm X 80 mm.
39d) M 16 mm x 50 mm
40e) M 20 mm X 80 mm.
41f) M 20 mm X 100 mm.
42M.S / G.I. Reducer with ISI Marked flanged.100mmx80mm dia
43M.S / G.I. Reducer with ISI Marked flanged.80mmx65mm dia
44ELECTRO MOTOR PUMP SETS, ISI MARKED, IS 12615 & IS 6595, Monoblock as per IS 9079 (read with latest ammendment for all IS)100 m3/hr,18 m head. (10 HP) (As per appvd. existing tech. spec.)
45MOTOR CONTROLLER, IS 6094710 HP 3 phase Electromagnetic Star-Delta motor controllers with 4 pole heavy duty Power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter & Voltmeter, all in IP54 enclosure of min 16swg. C R sheet steel, 10 tank process powder coat painted and as per technical specification
46BUSBAR CHAMBER, IS 6094763 A Busbar Chambers (As per appvd. existing dwg & tech. spec.)
47SWITCH FUSE UNIT, ISI MARKED, IS 6094763 A Switch Fuse Unit TPN (As per appvd. existing tech. spec.)
48SWITCH FUSE UNIT, ISI MARKED, IS 6094732 A Switch Fuse Unit TPN (As per appvd. existing tech. spec.)
493C Flat water proof CU.cables lSI marked-IS 694 3CX6 sq. mm
50Supply & Transportation of 500 mm dia (Table-5) Compressed Asbestos Fibre Jointing for Quadruped & Tripod set(for raised surface of flange as per IS:6392).
51100 mm dia Suction Hose, P.V.C.Flexible Hose pipe, ISI marked - IS 15265
52ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 150 mm dia
53Supply & Transportation of 100 mm dia Foot Valve Leather Washer best quality brand (Imperial/Techno/Burhani).
54Supply and transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with ISI Mark with latest amendmends suitable for raised surface of MS flange as per IS 6392/71 (Table 5, 11 & 17) with standard bore holes.200 mm dia Rubber Insertion (Table No.11)
55200 mm dia Rubber Insertion (Table No.5)
56150 mm dia Rubber Insertion (Table No.17)
57150 mm dia Rubber Insertion (Table No.5)
58100 mm dia Rubber Insertion (Table No.17)
5980 mm dia Rubber Insertion (Table No.17)
6065 mm dia Rubber Insertion (Table No.17)
61Laying of WTA
62Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
63Earthwork in excavation in the canals / drainage channels / borrow pits / River bed / slope of bank as noted below as per designed section & throwing the spoils in layers of 25 cm. for making banks as per profile or to deposit the same in any other place within an initial lead of 30 metre and initial lift of 1.5 metre including breaking clods, rough dressing etc. complete as per direction of the Engineer-in-charge.(a) Ordinary soil / local soil / soil mixed with moorum or kankar / silt, dry
64Laying of PVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipesfittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge. ii)200 mm. dia
65iii)140 mm. dia
66Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.)
67Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
68Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
691:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
70Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
71Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns
72Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars
73Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)
74Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
75Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
7615 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
77Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
78Fitting and fixing of M.S. I G.I. I C.l.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge.(iv) 150mm. dia. C.1.sluice valve
79b) 100mm. dia. C.I. Sluice Valve
80Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. (a) 150 mmm dia E.R.W Pipe.
81(i)(b) 100 mm. dia. NB ERW/MS pipes.
82Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for HDTW/MIDI RLI Scheme.(Rate inclusive of transportation from departmental store to work site).
83Labour charges for fitting and fixing 150 mm. diaAlfa Alfa G type valve with 140 mm. dia class-II U.P.V.C riser pipe with the help of flanged P.V.C tail piece by joining the P.V.C end of Tail piece and riser pipe with coupler and flanged end of tail piece and flap valve with rubber insertion , nuts and bolts etc. complete
84Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme ( one at rode side and other at site) the board will be made 3 mm thick MS plate of 300 mm X 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-I) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soilng. This will include one materials and labour complite as per drawing and direction of EIC.
85Installation of Diesel Engine Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally).b) For Midi R.L.I. Scheme.
86Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entire pipe line net work for at least 4 (four) hours by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge.ii) For Midi R.L.I.
87Carriage charge on every item from Sl. no-3,6,16,17,18,19,21,
88Cost indices of Purba Bardhaman as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is -[{(Total Amount of 2.01 to 2.06- Item No.. 2,3,6,16,17,18,19,20,21,22,23) x 0.973}x1.09] + (Cost of Item No. 2,3,6,16,17,18,19,20,21,22,23)]-Totao of 2.01 to 2.26
89Add GST 18% on Sl no. 2,3,6,16,17,18,19,20,21,22,23
90Add Cess 1% on 2,3,6,16,17,18,19,20,21,22,23 & 2.28
91Internal Wiring of Kiosk Box
92Supply, Fitting & fixing of DPIC main switch 15/16A 240 Volts (Havells) on board on wall including mending good the damage for light circuit of pump house
93Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set
94Supply & Fixing of 20 watt single / twin florescent light fitting complete with all accessories directly on wall / ceilling / TW round block and suitable size of fastener ..
95Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc incl supply of wire.
96Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire
97Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to light/fan/calling bell with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter
98Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switchboard embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessaryconnections as require
99Fixing only Sheet Steel TP/TPN Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall (32 Amps, 415 Volt) On angle iron frame
100Fixing only Sheet Steel TP/TPN Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall (63 Amps, 415 Volt) On angle iron frame
101Fixing only of 4 Bars 200 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall .
102Fitting and Fixing of Star Delta starter (for 20 HP motor contol) with nuts and bolts fixed on angle iron frame on wall and making necessary connection with the electrical cables.
103Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall.(b)Star-Delta starter for motor (above 5 HP upto 15 HP)
104Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. P.V.C./ XLPE insulated & sheathed and armoured Aluminium/Copper Cable fromMeter to incomming TPN Main Switch 1Terminal.(Brand: Gloster/Havells/Finolex).c) For MIDI RLI Schemei) 35 Sqmm 3%Core Aluminium Cable
105Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex) (b) For midi RLI(i) 4Cx 16 sqmm Copper cable conforming to IS 694 in [63 A TPN switch to Busbar]
106(ii) 3C X 10 sqmm copper cable conforming to IS 694 [Busbar to 32 A. TP Mainswitch and 32 A TP switch to Motor starter]
107(iii) 2 X 3C X 4 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSIMedium quality)Star-Delta Motor starter to Motor]
108Suppling & fitting & fixing of danger Board (mannual) 4\\"x6\\" in two distinguishing position in the door of pump house (outside) and at the palce of panel board.
109Earthing with 50 mm (2\\") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2\\") dia X80 mm (3\\") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12\\") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe (PWD elec. Sh. Page-G-1,item-2(a) )
110Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages..(PWD elec. Sh. Page-G-2, item-5a)
111Suppling fitting & fixing of shock treatment chart in a wooden frame with brass. (Passed rate of SE(A-M) Burdwan (A-M) Circle)
112Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger.
113Add GST @18% on 3.01 to 3.21
114Add Cess@ 1% on 3.01 to 3.22
115WUA Formation and Registration
116Campaigning in the command area of Midi RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.
117Demarcation of command area, selection of beneficiaries and preparation of land schedule within the Command area of one Midi RLI having CCA 40 Ha
118Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges
119Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C etc.
120Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting )
121Meeting and onsite demonstration for operation & maintenance of one Midi RLI tubewell, water manangement and mode of collection of water tax, building of corpus fund etc
122IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL - 4
123Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.
124Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period
125ENERGISATION: (Meterial Cost) PCC Pole 9 Meter Long
126M.S. CHANNEL 75 X 40 MM
127M.S ANGLE 65 X 65 X 6 MM.
128M.S. FLAT 65 X 6 MM
12911 KV POLYMER COMP. WH FTTG PIN
13011 KV POLYMER DISC INSL 11 KV
131COM HARDWARE FITTINGS
132HT STAY SET
133STAY WIRE 7/3.15MM
134HT GUY INSULATOR
135GI EARTH SPIKE
136G.I. WIRE 5MM.
137TURN BUCKLE 18 x 5/8\\"
138DTR 25 KVA
139ISL11KV 200A TPGO
140LA 12 KV (5KA)FOR 11 KV
141ACSR 50SQMM
142ACSR 20SQMM
143LT DIST KIOSK for 25 KVA DTR
144XLPE CABLE 4CX50 SQMM 1.1 KV
145PCC POLE 8 MTR
146LT STAY SET
147LT GUY INSULATOR
148STAY WIRE 7/2.5 MM
1491.1 KV AV CABLE
150IPC 50-70 SQMM
151LT DIST BOX
152EYE HOOK
153DEAD END CLAM LT ABC
154SUSP CLAMP 50 SQMM MESENGER
155CAUTION BOARD 11 KV
156SUNDRY @5% of MATERIAL
157ESCALATION @ 5% OF MATERIAL COST
158Labour Cost: ERECTION OF SUB-STATION STRUCTURE 9 MTR LONG
159ERECTION OF HT SINGLE POLE 9 MTR LONG
160EXTENSION OF PCC POLE
161STRINGING & SAGGING BY ACSR 50 SQ MM 3 WIRE
162FIXING OF PIN INSULATOR 11KV
163FIXING OF DISC INSULATOR 11KV
164Erection of Stay Set Complete HT
165EARTHING COMPLETE
166ERECTION OF DTR 25 KVA DTR
167Fixing of LT DIST Kiosk SINGLE CKT
168FIXING OF CRADLE GUARD BRACKET SINGLE POLE
169FIXING OF CRADLE GUARD BRACKET DOUBLE POLE
170FIXING OF LEAD WIRE ABOVE 30M BUT UPTO 60 MTR 2 WIRE
171FIXING OF CROSS LESSING
172FIXING OF 11 KV LA
173FIXING OF 11 KV TGPO ISOLATOR
174EARTHING DTR NEUTRAL POINT WITH SUPPLY OF MATERIALS
175SERVICE CONNECTION WITH FIXING 3 PH METER
176FIXING OF CAUTION BOARD
177SURVEY OF 11 KV LINE
178SURVEY OF LTOH LINE
179ERECTION OF SINGLE PCC POLE 8 MTR LONG
180LT STAY SET COMPLETE
181STN OF AB CABLE
182FIXING OF IPC
183FIXING OF LT DIST.BOX
184FIXING OF ANCHOR CLAMP
185FIXING OF SUSP. CLAMP
186Cess @ 1% on (Labour+Material+Suprvision)
187GST @ 18% on Labour Charge
188Quotation Money as per WBSEDCL Procedure(including supervision charge & 18% GST on supervision charge and Security Deposit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58012841
AUTHORITY Government Departments
TENDER VALUE 48.28 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Installation Of Of Santoshpur-Ii Special Midi Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga(A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 2026-27 Programme In The District Of Hooghly
Basic Detail
Tender No WBWRDD/SE (AM)/Res Circle/eNIT-40/2026-27
Bidding Type Tender
Location
City Hooghly
State West Bengal
Key Dates
Publish Date 13 Oct 2026
Submission Date 17 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 48.28 Lakhs
Tender Fee Ref. Documents
EMD 96570
Exemption Available
Document List
BOQ_2563956.xls
e78a4241-e851-4b33-b99f-f17dd700f3bc.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2563956.xls

html

e78a4241-e851-4b33-b99f-f17dd700f3bc.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender