Tender for Installation Of Of Santoshpur-Ii Special Midi Rli Scheme ( Including Supply And Delivery Of All Related Materials , All-In-One Works On Turn Key Basis ) Under Ch Adanga(A-M) Sub Division Under Chinsurah (A-M) Division Under Core Sector 2026-27 Programme In The District Of Hooghly
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Delivery of Materials: Supply of 200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments |
| 2 | Supply of 140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments |
| 3 | Supply of 140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments |
| 4 | Supply of 200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 5 | Supply of 140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 6 | Supply of 200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 7 | Supply of 160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 8 | Supply of 160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 9 | Supply of 200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 10 | Supply of 200 X 160 mm P.V.C. Reducer (Class-II) |
| 11 | Supply of 200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 12 | Supply of 140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 13 | Supply of 140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA) |
| 14 | Supply of 200 mm dia P.V.C. End Cap(Cl-III) |
| 15 | Supply of 140 mm dia P.V.C. End Cap(Cl-III) |
| 16 | Supply of 200 mm dia P.V.C.Extra Coupler (Class-II) |
| 17 | Supply of 140 mm dia P.V.C.Extra Coupler (Class-II) |
| 18 | Supply of 160 mm dia P.V.C.Extra Coupler (Class-II) |
| 19 | Supply of Solvent Cement(Extra) |
| 20 | GI Quadrupped Set for Midi RLI Scheme, All material ISI marked (As per appvd. existing drawing & tech. spec.) |
| 21 | 150 mm dia 90º G.I Bend (both end flanged), one end flange welded and other end ring welded with bracking flange ISI marked-IS-1239, Galv- IS 4736 (As per appvd. existing drawing & tech. spec.) |
| 22 | 100 mm dia 90º G.I Bend (both end flanged) long bend With priming arrangement, ISI marked-IS-1239, Galv- IS 4736 (As per appvd. existing drawing & tech. spec.) |
| 23 | 100 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736(As per appvd. existing drawing & tech. spec.) |
| 24 | 150 mm.dia Galv. MS Flanged Pipe ISI marked- IS- 1239, Galv- IS 4736 (4.8mm)(As per appvd. existing drawing & tech. spec.) |
| 25 | Supply & transport of MS Kiosk Box of size 72\\" X 48\\" X 30\\" made with 16 gauge ms sheet fitting and fixing by running welding on (50 X50X6) angle with painting complete as per direction of EIC. |
| 26 | Supply and transport of 20 HP Motor cover of size 600 x 600 x 700mm made with 25 x 25 x 5mm angel 2mm thick M.S. sheet with 4 Nos. Handle and Locking arrangement and fitting and fixing by running welding with painting complete as per drawing and direction of EIC. |
| 27 | 150 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846 (As per appvd. existing tech. spec.) |
| 28 | 100 mm dia C.I. Sluice Valve with hand wheel, ISI marked- IS 14846 (As per appvd. existing tech. spec.) |
| 29 | 150 mm dia (type-C) Alfa Alfa Valve (nipple type) with handwheel 01 no. for 04 nos valve, as per IS 210/2009 (As per appvd. existing drawing & tech. spec.) |
| 30 | Supply & Transportation of 100 mm dia C.I. Foot valve, flanged end & swing type. The disc face will be made of leather and strainer made of galvanized steel.The Valves shall be tested for (closed end test) against Hydrostatic test requirement |
| 31 | Supply & Transportation of 100 mm dia MS Heavy Duty Hose Clamp fitted with bolts & nuts (2 sets), 2 mm thick, 30 mm width. One coat of Black Japan |
| 32 | Supply & Transportation of MS Hose Clamp150 mm dia (45 mm thick, 2 mm width) |
| 33 | Supply of C.I. Flanged Tail piece/Nipple150 mm dia.Tail piece one end flanged other end grooved. |
| 34 | Supply & Transportation of 100 mm dia C.I. Tail Piece with one end flanged and other end grooved, overall length (175+/-15) mm. (23 mm flange thk) with 7 nos. grooves. |
| 35 | Supply & Transportation of Foundation Bolt, manufactured from 20 mm nominal diameter MS Rod as per IS:2062/1992. Total length of the Bolt is 375 +10 mm having welded head 80 +10 mm in length and 20 mm in nominal diameter nut and 2 nos. washer, The average weight of such bolt to be 1.5 kg. per bolt with tolerance in weight of each bolt @ +10%. |
| 36 | For Electro motor Pump Sets |
| 37 | Supply & Transportation of GI Hexagonal Head Nuts and Bolts conforming to IS 1363(Part-I)/1992 of product grade C with latest amendmends for Bolts & IS 1363(Part-3)/1992 of product Grade-C with latest amendments for Nuts properties /Class for Bolt-4.6 & for Nut-4.5. ISI marked.a) M 16 mm X 65 mm. |
| 38 | c) M 16 mm X 80 mm. |
| 39 | d) M 16 mm x 50 mm |
| 40 | e) M 20 mm X 80 mm. |
| 41 | f) M 20 mm X 100 mm. |
| 42 | M.S / G.I. Reducer with ISI Marked flanged.100mmx80mm dia |
| 43 | M.S / G.I. Reducer with ISI Marked flanged.80mmx65mm dia |
| 44 | ELECTRO MOTOR PUMP SETS, ISI MARKED, IS 12615 & IS 6595, Monoblock as per IS 9079 (read with latest ammendment for all IS)100 m3/hr,18 m head. (10 HP) (As per appvd. existing tech. spec.) |
| 45 | MOTOR CONTROLLER, IS 6094710 HP 3 phase Electromagnetic Star-Delta motor controllers with 4 pole heavy duty Power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons, Ammeter & Voltmeter, all in IP54 enclosure of min 16swg. C R sheet steel, 10 tank process powder coat painted and as per technical specification |
| 46 | BUSBAR CHAMBER, IS 6094763 A Busbar Chambers (As per appvd. existing dwg & tech. spec.) |
| 47 | SWITCH FUSE UNIT, ISI MARKED, IS 6094763 A Switch Fuse Unit TPN (As per appvd. existing tech. spec.) |
| 48 | SWITCH FUSE UNIT, ISI MARKED, IS 6094732 A Switch Fuse Unit TPN (As per appvd. existing tech. spec.) |
| 49 | 3C Flat water proof CU.cables lSI marked-IS 694 3CX6 sq. mm |
| 50 | Supply & Transportation of 500 mm dia (Table-5) Compressed Asbestos Fibre Jointing for Quadruped & Tripod set(for raised surface of flange as per IS:6392). |
| 51 | 100 mm dia Suction Hose, P.V.C.Flexible Hose pipe, ISI marked - IS 15265 |
| 52 | ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 150 mm dia |
| 53 | Supply & Transportation of 100 mm dia Foot Valve Leather Washer best quality brand (Imperial/Techno/Burhani). |
| 54 | Supply and transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to IS 638/79 with ISI Mark with latest amendmends suitable for raised surface of MS flange as per IS 6392/71 (Table 5, 11 & 17) with standard bore holes.200 mm dia Rubber Insertion (Table No.11) |
| 55 | 200 mm dia Rubber Insertion (Table No.5) |
| 56 | 150 mm dia Rubber Insertion (Table No.17) |
| 57 | 150 mm dia Rubber Insertion (Table No.5) |
| 58 | 100 mm dia Rubber Insertion (Table No.17) |
| 59 | 80 mm dia Rubber Insertion (Table No.17) |
| 60 | 65 mm dia Rubber Insertion (Table No.17) |
| 61 | Laying of WTA |
| 62 | Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. |
| 63 | Earthwork in excavation in the canals / drainage channels / borrow pits / River bed / slope of bank as noted below as per designed section & throwing the spoils in layers of 25 cm. for making banks as per profile or to deposit the same in any other place within an initial lead of 30 metre and initial lift of 1.5 metre including breaking clods, rough dressing etc. complete as per direction of the Engineer-in-charge.(a) Ordinary soil / local soil / soil mixed with moorum or kankar / silt, dry |
| 64 | Laying of PVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipesfittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge. ii)200 mm. dia |
| 65 | iii)140 mm. dia |
| 66 | Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.) |
| 67 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 68 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 69 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 70 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 71 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns |
| 72 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars |
| 73 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 74 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 75 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) |
| 76 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 77 | Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete. |
| 78 | Fitting and fixing of M.S. I G.I. I C.l.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge.(iv) 150mm. dia. C.1.sluice valve |
| 79 | b) 100mm. dia. C.I. Sluice Valve |
| 80 | Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. (a) 150 mmm dia E.R.W Pipe. |
| 81 | (i)(b) 100 mm. dia. NB ERW/MS pipes. |
| 82 | Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for HDTW/MIDI RLI Scheme.(Rate inclusive of transportation from departmental store to work site). |
| 83 | Labour charges for fitting and fixing 150 mm. diaAlfa Alfa G type valve with 140 mm. dia class-II U.P.V.C riser pipe with the help of flanged P.V.C tail piece by joining the P.V.C end of Tail piece and riser pipe with coupler and flanged end of tail piece and flap valve with rubber insertion , nuts and bolts etc. complete |
| 84 | Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme ( one at rode side and other at site) the board will be made 3 mm thick MS plate of 300 mm X 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-I) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soilng. This will include one materials and labour complite as per drawing and direction of EIC. |
| 85 | Installation of Diesel Engine Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally).b) For Midi R.L.I. Scheme. |
| 86 | Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entire pipe line net work for at least 4 (four) hours by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge.ii) For Midi R.L.I. |
| 87 | Carriage charge on every item from Sl. no-3,6,16,17,18,19,21, |
| 88 | Cost indices of Purba Bardhaman as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is -[{(Total Amount of 2.01 to 2.06- Item No.. 2,3,6,16,17,18,19,20,21,22,23) x 0.973}x1.09] + (Cost of Item No. 2,3,6,16,17,18,19,20,21,22,23)]-Totao of 2.01 to 2.26 |
| 89 | Add GST 18% on Sl no. 2,3,6,16,17,18,19,20,21,22,23 |
| 90 | Add Cess 1% on 2,3,6,16,17,18,19,20,21,22,23 & 2.28 |
| 91 | Internal Wiring of Kiosk Box |
| 92 | Supply, Fitting & fixing of DPIC main switch 15/16A 240 Volts (Havells) on board on wall including mending good the damage for light circuit of pump house |
| 93 | Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set |
| 94 | Supply & Fixing of 20 watt single / twin florescent light fitting complete with all accessories directly on wall / ceilling / TW round block and suitable size of fastener .. |
| 95 | Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc incl supply of wire. |
| 96 | Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire |
| 97 | Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to light/fan/calling bell with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter |
| 98 | Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switchboard embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessaryconnections as require |
| 99 | Fixing only Sheet Steel TP/TPN Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall (32 Amps, 415 Volt) On angle iron frame |
| 100 | Fixing only Sheet Steel TP/TPN Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall (63 Amps, 415 Volt) On angle iron frame |
| 101 | Fixing only of 4 Bars 200 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall . |
| 102 | Fitting and Fixing of Star Delta starter (for 20 HP motor contol) with nuts and bolts fixed on angle iron frame on wall and making necessary connection with the electrical cables. |
| 103 | Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall.(b)Star-Delta starter for motor (above 5 HP upto 15 HP) |
| 104 | Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. P.V.C./ XLPE insulated & sheathed and armoured Aluminium/Copper Cable fromMeter to incomming TPN Main Switch 1Terminal.(Brand: Gloster/Havells/Finolex).c) For MIDI RLI Schemei) 35 Sqmm 3%Core Aluminium Cable |
| 105 | Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex) (b) For midi RLI(i) 4Cx 16 sqmm Copper cable conforming to IS 694 in [63 A TPN switch to Busbar] |
| 106 | (ii) 3C X 10 sqmm copper cable conforming to IS 694 [Busbar to 32 A. TP Mainswitch and 32 A TP switch to Motor starter] |
| 107 | (iii) 2 X 3C X 4 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSIMedium quality)Star-Delta Motor starter to Motor] |
| 108 | Suppling & fitting & fixing of danger Board (mannual) 4\\"x6\\" in two distinguishing position in the door of pump house (outside) and at the palce of panel board. |
| 109 | Earthing with 50 mm (2\\") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2\\") dia X80 mm (3\\") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12\\") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe (PWD elec. Sh. Page-G-1,item-2(a) ) |
| 110 | Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages..(PWD elec. Sh. Page-G-2, item-5a) |
| 111 | Suppling fitting & fixing of shock treatment chart in a wooden frame with brass. (Passed rate of SE(A-M) Burdwan (A-M) Circle) |
| 112 | Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger. |
| 113 | Add GST @18% on 3.01 to 3.21 |
| 114 | Add Cess@ 1% on 3.01 to 3.22 |
| 115 | WUA Formation and Registration |
| 116 | Campaigning in the command area of Midi RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc. |
| 117 | Demarcation of command area, selection of beneficiaries and preparation of land schedule within the Command area of one Midi RLI having CCA 40 Ha |
| 118 | Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges |
| 119 | Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C etc. |
| 120 | Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting ) |
| 121 | Meeting and onsite demonstration for operation & maintenance of one Midi RLI tubewell, water manangement and mode of collection of water tax, building of corpus fund etc |
| 122 | IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL - 4 |
| 123 | Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy. |
| 124 | Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period |
| 125 | ENERGISATION: (Meterial Cost) PCC Pole 9 Meter Long |
| 126 | M.S. CHANNEL 75 X 40 MM |
| 127 | M.S ANGLE 65 X 65 X 6 MM. |
| 128 | M.S. FLAT 65 X 6 MM |
| 129 | 11 KV POLYMER COMP. WH FTTG PIN |
| 130 | 11 KV POLYMER DISC INSL 11 KV |
| 131 | COM HARDWARE FITTINGS |
| 132 | HT STAY SET |
| 133 | STAY WIRE 7/3.15MM |
| 134 | HT GUY INSULATOR |
| 135 | GI EARTH SPIKE |
| 136 | G.I. WIRE 5MM. |
| 137 | TURN BUCKLE 18 x 5/8\\" |
| 138 | DTR 25 KVA |
| 139 | ISL11KV 200A TPGO |
| 140 | LA 12 KV (5KA)FOR 11 KV |
| 141 | ACSR 50SQMM |
| 142 | ACSR 20SQMM |
| 143 | LT DIST KIOSK for 25 KVA DTR |
| 144 | XLPE CABLE 4CX50 SQMM 1.1 KV |
| 145 | PCC POLE 8 MTR |
| 146 | LT STAY SET |
| 147 | LT GUY INSULATOR |
| 148 | STAY WIRE 7/2.5 MM |
| 149 | 1.1 KV AV CABLE |
| 150 | IPC 50-70 SQMM |
| 151 | LT DIST BOX |
| 152 | EYE HOOK |
| 153 | DEAD END CLAM LT ABC |
| 154 | SUSP CLAMP 50 SQMM MESENGER |
| 155 | CAUTION BOARD 11 KV |
| 156 | SUNDRY @5% of MATERIAL |
| 157 | ESCALATION @ 5% OF MATERIAL COST |
| 158 | Labour Cost: ERECTION OF SUB-STATION STRUCTURE 9 MTR LONG |
| 159 | ERECTION OF HT SINGLE POLE 9 MTR LONG |
| 160 | EXTENSION OF PCC POLE |
| 161 | STRINGING & SAGGING BY ACSR 50 SQ MM 3 WIRE |
| 162 | FIXING OF PIN INSULATOR 11KV |
| 163 | FIXING OF DISC INSULATOR 11KV |
| 164 | Erection of Stay Set Complete HT |
| 165 | EARTHING COMPLETE |
| 166 | ERECTION OF DTR 25 KVA DTR |
| 167 | Fixing of LT DIST Kiosk SINGLE CKT |
| 168 | FIXING OF CRADLE GUARD BRACKET SINGLE POLE |
| 169 | FIXING OF CRADLE GUARD BRACKET DOUBLE POLE |
| 170 | FIXING OF LEAD WIRE ABOVE 30M BUT UPTO 60 MTR 2 WIRE |
| 171 | FIXING OF CROSS LESSING |
| 172 | FIXING OF 11 KV LA |
| 173 | FIXING OF 11 KV TGPO ISOLATOR |
| 174 | EARTHING DTR NEUTRAL POINT WITH SUPPLY OF MATERIALS |
| 175 | SERVICE CONNECTION WITH FIXING 3 PH METER |
| 176 | FIXING OF CAUTION BOARD |
| 177 | SURVEY OF 11 KV LINE |
| 178 | SURVEY OF LTOH LINE |
| 179 | ERECTION OF SINGLE PCC POLE 8 MTR LONG |
| 180 | LT STAY SET COMPLETE |
| 181 | STN OF AB CABLE |
| 182 | FIXING OF IPC |
| 183 | FIXING OF LT DIST.BOX |
| 184 | FIXING OF ANCHOR CLAMP |
| 185 | FIXING OF SUSP. CLAMP |
| 186 | Cess @ 1% on (Labour+Material+Suprvision) |
| 187 | GST @ 18% on Labour Charge |
| 188 | Quotation Money as per WBSEDCL Procedure(including supervision charge & 18% GST on supervision charge and Security Deposit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender