Drinking Water Supply and Sanitation Government Departments Closing in 27 days TDR #58012836

Tender For Installation Of New Mainan-Ii Major Rli Schemes (Handed Over) On Turn-Key Basis Under Ch Adanga (A-M) Sub-Division Under Chinsurah (A-M) Division Under Core Sector Programme In The District Of Hooghly

Issued by Government Departments · Hooghly, West Bengal
Tender Value
99.39 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
27 days left
EMD
1.98 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Installation Of New Mainan-Ii Major Rli Schemes (Handed Over) On Turn-Key Basis Under Ch Adanga (A-M) Sub-Division Under Chinsurah (A-M) Division Under Core Sector Programme In The District Of Hooghly

BOQ

Name of Work:- Installation of New Mainan-II Major RLI Schemes (Handed Over) on Turn-Key Basis under Ch adanga (A-M) Sub-Division under Chinsurah (A-M) Division under Core Sector Programme in the District of Hooghly
Sl. No. Item Description
1Supply of Materials: Supply of 315 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
2Supply of 200 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
3Supply of 140 mm dia P.V.C. Pipe(Cl-I) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
4Supply of 140 mm dia P.V.C. Pipe(Cl-II) with Coupler (Class-II) As per IS 4985:2000 with latest amendments
5Supply of 200 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
6Supply of 140 mm dia P.V.C. Equal Tee as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
7Supply of 315 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
8Supply of 200 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
9Supply of 160 mm dia F.T.P. as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
10Supply of 160 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
11Supply of 200 X 140 mm P.V.C. Reducer (Class-II) as per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
12Supply of 200 X 160 mm P.V.C. Reducer (Class-II)
13Supply of 200 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
14Supply of 140 X 60º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
15Supply of 140 X 90º P.V.C. Bend s per IS-10124/2009 and shall be duly marked with standard ISI certification marks & class Class-II (0.40 MPA)
16Supply of 200 mm dia P.V.C. End Cap(Cl-III)
17Supply of 140 mm dia P.V.C. End Cap(Cl-III)
18Supply of 315 mm dia P.V.C.Extra Coupler (Class-II)
19Supply of 200 mm dia P.V.C.Extra Coupler (Class-II)
20Supply of 160 mm dia P.V.C.Extra Coupler (Class-II)
21Supply of 140 mm dia P.V.C.Extra Coupler (Class-II)
22Supply of Solvent Cement(Extra)
23M.S. ACCESSORIES: Supply of GI Set for Distribution Chamber , All material ISI marked (As per appvd. existing drawing & tech. spec.) a)Quadruped Set for Major RLI
24Supply of C.I. Sluice Valve With hand Wheel, ISI marked , IS : 14846 a) 150 mm Dia
25Supply of 150 mm dia NB Foot Valve (Flanged type) lS -4038 / 1986
26Supply of Alfa Alfa Valve (nipple type) with handwheel 01 no. for 04 nos valve. (As per appvd. existing dwg.) a) 150 mm N.B. (Type-C)
27Supply of 90 degree G.I Bend (both end flanged-ISI marked-IS 1239,Galv- IS4736 a) 150 mm dia
28b) 150 mm dia long bend (with priming)
29Supply of Galv. MS Flanged Pipe ISI marked- IS: 1239, Galv- IS 4736 a) 150mm.dia (4.8mm)
30Supply of MS Hose Clamp : 150 mm dia (45 mm thick, 2 mm width)
31Supply of C.I. Flanged Tail piece/Nipple : 150 mm dia.Tail piece one end flanged other end grooved.
32Supply and Delivery of Foundation Bolt for Distribution Chambers (Quadruped Sets) manufactured from 20 mm nominal diameter M.S Rod as per IS 2062/1992. Total length of the Bolt is 375+ 10 mm having welded head 80+ 10 mm in length & 20 mm in nominal diameter with Nut & Bolt
33Supply and Delivery of Foundation Bolt for Distribution Chambers (Quadruped Sets) manufactured from 16 mm nominal diameter M.S Rod as per IS 2062/1992. Total length of the Bolt is 375+ 10 mm having welded head 80+ 10 mm in length & 16 mm in nominal diameter with Nut & Bolt
34Supply and Delivery of GI Hexagonal Head Bolts & Nuts conforming to IS-1363 (Part-I) 1992 product grade - C with latest ammedments for boths IS-1363 (Part-3) / 1992 of product grade C with latest amount for nuts properties / class for bolt 4.62 nuts for 4.5. M 20x80 mm.
35M 20x100 mm.
36M.16x65 mm
37M 16x80 mm
38M 16x 50 mm
39ELECTRICAL ACCESSORIES : Electro Motor Pump Sets, ISI marked, IS-12615 & IS-6595; Monoblock as per IS 9079 (read with latest ammendment for all IS) 200 m³/hr, 24 m head. (25 HP)
40Switch Fuse Unit, lSI marked, IS 60947 -63 Amps 415 volts A.C TPN Main Switch. (ISI Marked)
41Switch Fuse Unit, Confirming to IS 60947 -200 Amps 415 volts A.C TPN Main Switch.
42MOTOR CONTROLLER, IS 60947 20 HP 3 Phase Electromagnetic Star- Delta motor controllers with 4 pole heavy duty Power contactor, single phasing preventer and normal protective features, MCB, Indicators, push buttons , Ammeter & Voltmeter, all in IP54 enclosure of min 16swg. C R sheet steel,10 tank process powder coat painted and as per technical specification.(WRI&DD SOR , Chapter-13: Item No.-20,Rates of Materials for the Program 2026-2027)
43Bus Bar Chambers (As per appvd. existing dwg)-IS60947 - a)200Amp
44Supply of 50 mm², 3.5 core, XLPE insulated Al armoured overall PVC sheathed 11000 volts grade power cable conforming to IS: 7098 (Part-I) 1988 with latest ammendments.
453C Flat water proof CU cables ISI marked -IS 694
46OTHER MATERIALS : Compresed Asbestos fibre jointing for Quadruped & Tripod set (for raised surface of Flange as per IS-6392) a) 500 mm.dia (Table-5)
47P.V.C. Flex Hose pipe, ISI marked - IS 15265 - a)150 mm dia Suction Hose
48150 mm dia Foot Valve Leather Washer
49Rubber Insertion (for raised surface of Flange as per IS-6392) a) 300 mm.dia( Table-11)
50200 mm.dia( Table-11)
51200 mm.dia( Table-5)
52150 mm.dia( Table -17)
53150 mm.dia( Table -5)
5480 mm.dia( Table -5)
55Laying of WTA : Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
56Earthwork in excavation in the canals / drainage channels / borrow pits / River bed / slope of bank as noted below as per designed section & throwing the spoils in layers of 25 cm. for making banks as per profile or to deposit the same in any other place within an initial lead of 30 metre and initial lift of 1.5 metre including breaking clods, rough dressing etc. complete as per direction of the Engineer-in-charge. (a) Ordinary soil / local soil / soil mixed with moorum or kankar / silt, dry or moist / slushy silt / sticky soil.
57Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. a) 315 mm dia
58b) 200 mm dia
59c) 140 mm dia
60Earth work in filling in trenches after laying pipe lines (PVC,RCC,ACP etc.) with good earth obtained from excavation of field trences in layer not exceeding 225 mm , including watering & ramming etc. layer by layer complete. (payment will be made on the basis of measurement of finished quantity of work)
61Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
63Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
64Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
65Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns.
66Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars.
67Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
68Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
69Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
7015 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
71Neat cement punning.
72Fitting and fixing of M.S. / G.I. / C.I.accessories and special in pipe line (accessories & special to be supplied departmentally) including supply of jointing materials viz.rubber insertion, nuts & bolts, havoc Zink (Zink Oxide) complete as per direction of Engineer-in-Charge. a) 150 mm dia sluice valve.
73Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge. (i) 150 mm. dia. ERW pipe.
74Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Major RLI Scheme. (Rate inclusive of transportation from departmental store to work site)
75Supplying, fitting and fixing including transportation of sign board for identifying the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C
76Placing and positioning the Centrifugal pump motor set on the pump base / pump house floor, aligning properly with necessary packing and fixing the set with holding down nuts and washerincluding cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages complete as per direction of the Engineer-in-Charge.
77Labour charges for fitting, fixing 150 mm. Dia. Alfa-Alfa valve with 140 mm. dia.P.V.C. pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C.End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.{ WRI&DD SOR 2018/ Chapter No. VI.SLno.2.20,page no-15,Item No-3)
78Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Diesel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-inCharge.
794% Carriage charge on item SL NO.-2.03, 2.04, 2.05, 2.18, 2.19, 2.20 & 2.21
80Cost indices of Purba Bardhaman as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is -[{(Total Amount- Item No.- 2,3,4,6,16,17,18,19,20,21,22,23,24) x 0.973}x1.09] + (Cost of Item No.-2,3,4,6,16,17,18,19,20,21,22,23,24)-[Total Amount from 2.01 to 2.25)
81Add GST 18% on 2,3,4,6,16,17,18,19,20,21,22,23,24
82Add Cess 1% on 2,3,4,6,16,17,18,19,20,21,22,23,24 & C
83Construction of PH : Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil (considering 50 mm clearence)
84Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
85Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
86Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
87Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
88Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
89Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
90Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
91Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
92Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars
93Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
94Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
9515 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)
9620 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
9712 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
9825mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
99Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thick
100Neat cement punning.
101Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
102Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
103Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes a) 75 mm diameter
104b) Single tee without door. 75x75x75 mm
105c) Bend 87.5 degree 75 mm bend
106Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
107Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
108Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work Steel surface iv) Two coats (with any shade except white)
109White washing with lime to give an even shade :New work (three or more coats)
110Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
111Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
1124% Carriage charge on item SL NO.-2.03, 2.04, 2.05, 2.18, 2.19, 2.20 & 2.21
113Cost indices of Purba Bardhaman as on 01.10.2025 based on DPAR 2025 (Base 100) is 109 as per Office Memoramdum vide Memo No.- 34(1)/SDG(Kol)/Cost Index/2026/915, dated - 19.05.2026 of CPWD, Government of India.Hence the total cost of the scheme is -[{(Total Amount- Item No.- 3,16,17,20,27,28 ) x 0.973}x1.09] + (Cost of Item No.-3,16,17,20,27,28)-[Total Amount from 3.01 to 3.30]
114Add GST 18% on Sl. No. - 3.03, 3.17, 3.18, 3.21 & 3.30
115Add Cess 1% on Sl. No. - 3.03, 3.17, 3.18, 3.21, 3.31 & 3.33
116Supply of Material For Energization :Pcc Pole 9 mtr long
117GI STAY SET HT
118G I STAY WIRE 7/3.15MM
119Porcelain guy insulator HT
120G I EARTH SPIKE 1833X20MM
121G.I. WIRE 5 MM.
122DTR 63 Kva
123Polymer Pin insulator 11 kv
124Polymer Disc insulator 11 kv
125Hard wire fittings 11 kv
126PVC Cable 50 sqmm 4 core
127LT Kiosk 63 kva DTR
128ACSR 50 sqmm
129Pcc Pole 8 mtr long
130GI STAY SET LT
131G I STAY WIRE 7/2.5MM
132Porcelain guy insulator LT
1331.1 LT AB cable 70 sqmm
134Eye Hook
135Anchor Clamp
136Connector
137SMC Box
138MS V Bracket 11 kv 9 mtr
139MS Top adoptor 11 kv 9 mtr
140TPGO Isolator 11 kv
141MS Channel 100x50x6 mm
142M/S Channel 75x40x6 mm
143M/S Angle 65x65x6 mm
144M/S Flat 65x6 mm
145Labour Cost : Conduction of Physical Survey Using VM APP
146Painting of Digits for Unique pole No on Pole
147Earthing Complete
148Survey HTOH line
149Survey LTOH line
150Service connection charge 3 ph PRO- A with materilas
151Erection of Sub Stn DP 9 mtr pcc pole
152Erection of DP Structure 9 mtr pole HT
153Erection of Single Pcc Pole 9 Mtr long HT
154Erection of Stay Set Complete HT
155Erection of Stay Set Complete LT
156Erection of Single Pcc Pole 8 Mtr long LT
157Sagging with 1.1 LT AB Cable 70 sqmm
158Fixing of Anchor (Dead end) Clamp
159Fixing of Connector
160Fixing of SMC Box
161Fixing of Pin insulator 11 kv
162Fixing of Disc insulator 11 kv
163Erection of 63 kva DTR
164Fixing of TPGO isolator 11 kv
165Sagging with ACSR 50 sqmm x 3 w
166Re Sagging with ACSR 50 sqmm x 3 w
167Fixing of LT Kiosk
168Earthing DTR Nutral with materials
169Fixing of LA
170Fixing of T off Bracket on SP
171Cess @ 1% on (Labour+Material+Suprvision)
172GST @ 18% on Labour Charge
173Quotation Money as per WBSEDCL Procedure(including supervision charge & GST on supervision charge
174Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall I(for fitting & fixing of electrial equipments as necessary on the plank). (WRDD schedule Item no-9 ,Page-42,Sl no-8)
175Supply, Fitting & fixing of DPIC main switch 15/16A 240 Volts (Havells) on board on wall including mending good the damage for light circuit of pump house (PWD elec. Sh. Page-D-1,item -1(a)
176Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set (PWD elec. Sh. Page-D-13,item- 1(23)
177Supply & Fixing of 20 watt single / twin florescent light fitting complete with all accessories directly on wall / ceilling / TW round block and suitable size of fastener ..((PWD elec. Sh. Page-D-13,item- 24)
178Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including
179Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necess
180Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, incl
181Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switchboard embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and
182Fitting & fixing of 200A 500 V iron clad/ sheet steel TP/ TPN main switch on iron legs on wall.(PWD elec. Sh. Page-C-1,item-1 )
183Fitting & fixing of 63A 500 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall . (PWD elec. Sh. Page-C-1,item-1)
184Fitting & fixing of only 200A 500V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps .( PWD elec. Sh. Page-C-1,item-6 )
185Fitting & fixing of Star - Delta starter (for 20 HP motor contol) on angle iron frame on wall . (PWD elec. Sh. Page-C1,item-7(b) )
186Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories lik
187(iii) 2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI-Medium quality) IfStar-DeltaMotor starter to Motor] WRI&DD SOR 2018/ Ch-6.0 para-9.0 sl-14 page 42
188Suppling & fitting & fixing of danger Board (mannual) 4\\"x6\\" in two distinguishing position in the door of pump house (outside) and at the palce of panel board. (PWD elec. Sh. Page-D-13, item- 21(a))
189Earthing with 50 mm (2\\") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2\\") dia X80 mm (3\\") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe p
190Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilloed holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.(PWD elec
191Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and
192Suppling fitting & fixing of shock treatment chart in a wooden frame with brass. (Passed rate of SE(A-M) Burdwan (A-M) Circle)
193Add GST @18% on All items from Sl No-5.01 to 5.23
194Add Cess@ 1% on ( All item from SL No- 5.01 to 5.24)
195Activities of Community Workers / WUA :Campaigning in the command area of New Major RLI Sub-project by community workers for mass awareness , capacity building to achieve sustainability of Sub-projects. Cost include wage payment to community workers, transportaton, leaflet etc.[Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
196Demarcation of command area, selection of beneficiaries and preparation of land schedule within the Command area of one New Major RLI having CCA 50.75 Ha [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
197Meeting Cost for WUA formation, cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
198Registration Cost for WUA under suitable act ( Society ) deed writing including registration charge, conveyance cost & opening of Bank A/C Charges etc [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
199Livelyhood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge ( rate on meeting ) [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
200Meeting and onsite demonstration for operation & maintenance of one New Major RLI , water manangement and mode of collection of water tax, building of corpus fund etc [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
201IEC Materials ( Leaflet, poster, notebook )= 8 meetings, for SL - 2 and SL-4 [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
202Documentation Cost for activities of WUA Scheme - by still photography, report booklet etc in both hard and soft copy.[Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.]
203Impact study & monitoring of scheme by site visit of 2 Community workers during 3 years' period [Approved estimate regarding activities for institutional development for sustainability of project sent by Chief Engineer - I, WRDD, via e-mail on 23/05/2022.] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58012836
AUTHORITY Government Departments
TENDER VALUE 99.39 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Installation Of New Mainan-Ii Major Rli Schemes (Handed Over) On Turn-Key Basis Under Ch Adanga (A-M) Sub-Division Under Chinsurah (A-M) Division Under Core Sector Programme In The District Of Hooghly
Basic Detail
Tender No WBWRDD/SE (AM)/Res Circle/eNIT-37(Sl. 1 to 2)/2026-27
Bidding Type Tender
Location
City Hooghly
State West Bengal
Key Dates
Publish Date 13 Oct 2026
Submission Date 17 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 99.39 Lakhs
Tender Fee Ref. Documents
EMD 1.98 Lakhs
Exemption Available
Document List
BOQ_2563748.xls
c18d939b-fbed-4cbb-922e-cd0e68ad4622.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2563748.xls

html

c18d939b-fbed-4cbb-922e-cd0e68ad4622.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender