Tender For Annual Maintenance Of electrical installation Works In Govt. Residential & Non-Residential Building Of Pwd Under North Tripura District Tripura. (2Nd Call)
Tender Value
6.86 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
15 days left
EMD
13737
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Of electrical installation Works In Govt. Residential & Non-Residential Building Of Pwd Under North Tripura District Tripura. (2Nd Call)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required. (as per TSR 2021 Sl.101) |
| 2 | Short Point |
| 3 | Medium Point |
| 4 | Long Point |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required.(as per TSR 2021 Sl.103) |
| 6 | Providing and fixing of 3/6 pin15/16 amps plug point with piano type 15/16 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. (as required.(as per TSR 2021 Sl.104) |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.(as required.(as per TSR 2021 Sl.205) |
| 8 | 2x1.5 sq.mm: |
| 9 | 2x2.5 sq.mm: |
| 10 | 2x4 sq.mm: |
| 11 | 4x6 sq.mm: |
| 12 | 4x10 sq.mm: |
| 13 | Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required.(as required.(as per TSR 2021 Sl.503) |
| 14 | 1 X 1.5 sq mm |
| 15 | 2 X 1.5 sq mm |
| 16 | 1 X 2.5 sq mm |
| 17 | 2 X 2.5 sq mm |
| 18 | 1 X 4 sq mm |
| 19 | 2 X 4 sq mm |
| 20 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required.(as per TSR 2021 Sl.717) |
| 21 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. (as per TSR 2021 Sl.707) |
| 22 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.( As per TSR 2021 Sl-602) |
| 23 | 19/20 mm dia |
| 24 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.( As per TSR 2021 Sl-604) |
| 25 | 5/6 amps piano type switch |
| 26 | 16/20 amps piano type switch |
| 27 | 3 pin 5/6 amps piano type socket |
| 28 | 3/6 pin 16/20 amps piano type socket |
| 29 | Electronic 4 step mini fan regulator |
| 30 | Angle/batten holder |
| 31 | Ceiling rose |
| 32 | 2.5 mfd fan capacitor |
| 33 | 5 amps power top |
| 34 | 15 amps power top |
| 35 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required.( As per TSR 2021 Sl-1201) |
| 36 | 32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx 80mm) |
| 37 | Supplying and fixing of the following ratings switch disconnector fuse unit(main switch)made of sheet steel enclosure with all accessories including drilling holes on the board/MS clamp and necessary connection etc. as required.(as per TSR 2021 Sl.1202) |
| 38 | 32 amps 240 volts DP (rewireable) |
| 39 | 32 amps 415 volts TPN main switch (rewireable) |
| 40 | Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. (as per TSR 2021 Sl.1208) |
| 41 | 4 way horizontal TPN MCB DB (Double door) |
| 42 | (2+4) / 6 way SPN MCB DB (Double door). |
| 43 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required. (as per TSR 2021 Sl.1215) |
| 44 | 6 to 32 amps SP MCB. |
| 45 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable(FR) ( ISI marked BEE 1 star / minimum service value 4.0) (as per TSR 2021 Sl.802) |
| 46 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required. (as per TSR 2021 Sl.817) |
| 47 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required. (as per TSR 2021 Sl.821) |
| 48 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt)(as per TSR 2021 Sl.1101) |
| 49 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp) |
| 50 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required. (as per TSR 2021 Sl.1103) |
| 51 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt) |
| 52 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink . |
| 53 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt)(as per TSR 2021 Sl.1102) |
| 54 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66) |
| 55 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required.(as per TSR 2021 Sl.1301) |
| 56 | 3 core 4 Sq mm |
| 57 | 4 core 16 Sq mm |
| 58 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable.(as per TSR 2021 Sl.1405) |
| 59 | 1.5 sqmm - 4 sqmm Cable. |
| 60 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required.(as per TSR 2021 Sl.1501) |
| 61 | 40 mm dia |
| 62 | Drawing of armoured/un-armoured cable with proper saddling etc as required.(as per TSR 2021 Sl.1511) |
| 63 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required. (as per TSR 2021 Sl.829) |
| 64 | Supplying and fixing of MS frame made of (25 x 25 x 5)mm MS angle with necessary support by (40 x 6)mm MS flat and 10 mm thick boiled plywood on top, grouted on wall with 4 nos leg(25x25x5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required. (as per TSR 2021 Sl.1502) |
| 65 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required.(as per TSR 2021 Sl.1602) |
| 66 | 850VA, 12V DC, 1 Ph input/1 Ph output inverter(Square wave technology). |
| 67 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required.(as per TSR 2021 Sl.1603) |
| 68 | 12 V/ 150AH tall tubular/ flat plate Battery Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender