Public Administrative Department Local Bodies Closing in 6 days TDR #58011262

Tender For Installation Of 02 Nos. Boom Barrier At Main Entrance And Exit Gate For Old Mig Flats, Phase-I, Prasad Nagar Society In Ward No. 86 Under Karol Bagh Zone

Issued by Local Bodies · Delhi, Delhi
Tender Value
6.61 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
6 days left
EMD
13300
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Installation Of 02 Nos. Boom Barrier At Main Entrance And Exit Gate For Old Mig Flats, Phase-I, Prasad Nagar Society In Ward No. 86 Under Karol Bagh Zone

BOQ

Name of Work:- Installation of 02 Nos. Boom Barrier at Main Entrance and Exit Gate for Old MIG Flats, Phase-I, Prasad Nagar Society in ward No. 86 under Karol Bagh Zone
Sl. No. Item Description
1Supply, installation, Testing and Commissioning of RFID/Fastag Based Automatic Boom Barrier complete in all respects (Civil/Electrical) A) Premium Quality Electromechanical Swing type Automatic Barriegate/ Boom Barrier: Boom of rectangular/oval/hexagonal shape made up of aluminium having minimum size of 100*40 mm, Telescopic Arm length - 3 to 6 meter, Microprocessor Based Controller, Noiseless operation with auto Cooling system with Reflecting LED light & Tapes in Length, Rated Power/Torque/Frequency:- 100-150W/ 50-60Kg, 50-100 Nm, 50/60Hz, CE/UL/BIS certified including following accessories as follows: a)PC Safety Anti accident Device, b)Dual Channel Loop Control Detector including Induction Coil for Auto close operation, c) 3 Way Opening switch controller (Push Button), d) Civil foundation works (PCC)(foundation of minimum size 450mmLx450mm Wx350mm D (100 mm above ground level)(NS using M15 grade concrete)) , e) The name of the MP/MLA/Councillor etc is to be written with their constituency with enamel paint of suitable size B) RFID Reader and Controller may be integrated as Per form factor of the system provided by the vendor. Tag Read Range : 15-20 meter ,Tag Write Range : 0-6 mtr Freq Range: Global 902~928 MHZ and 865~868 MHZ, Capability: Simultaneous multiple tag read capability Antenna : 12 dBi built in and Linear Polarized Reading Clue : Buzzer/LED/ Suitable indication Frequency Hopping : FHSS Software Programmable or Fixed, Power Output : 0-30 dBm or more, Working Mode: Auto running, interactive,Trigger Activating Mode Interface/Ports : RS 485/ RS 232/ Wiegand/TCP IP/RJ45 Protocols : ISO certified Working Temp : -20°C to +80°C, Humidity : Upto 95% or better,Regulatory: Compliance with CE & FCC & ROHS & MSME & BIS, Power Consumption : 1-2 Watt, Protection Grade: IP65, Mounting and casing : All weather proof Input Power : 100-240V, DC +9V adapter (1Set as 01 for Entry & 01 for Exit Total 02 Nos.) C) Single door controller for 02 Reader having the capability/ capacity to verify the vehicle tag in almost real time and should be able to maintain the records/ data of at least 5000 Vehicles. Controller should have the capability to integrate control boom barrier. Communication ports : RS485/TCPIP, Working Temperature : -20°C to +80°C, Operating Humidity : upto 95% or better, Capacity : upto 10,000 card data or more, Visual Indicator : LED / Indication for power, communication, etc. Power : 220-240 V AC / DC power with adapter Certifications : CE, FCC, ROHS (02 Nos.) D) RFID Windshield Tag workable in dense fog and heavy rain or bad weather Dimensions : 100x30mm +-5%, 110x40mm (+-5%) (Antenna Size) Operation Frequency : 860-960 Mhz Protocol : ISO certified CHIP, Memory: 32-bit, TID – 64-bit ,Unique TID – 96-bit EPC Memory, Memory : Blockable & Password protected Adhesive Application Integrated Circuit (Qty. 350 Nos.) E) SITC of Mounting pole for RFID Reader with Sufficient height (02 Nos.) F) Fastag Integration one time exclusive of cloud charges, Monthly Internet Charges ( Excluding 3 core x 1.5 sqmm cable)
2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt as required).
3Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm
5Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
6Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
7Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
8Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
9Supplying and fixing 6A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
10Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. Water bound macadam.
11Fabrication, supply & erection of 5.0 mtr height, minimum 3 mm thick, bottom dia of 130 mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplylng and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. Gl strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/c providing and flxing DIN channel of suitable length, 6 Amp. SPMCB 'C' Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole Galvanization as per relevant IS code etc as required.
12Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos. and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts size 16 mm dia, 600mm long, J type i/c 2 nos template anchor plates of size 225 mm x 225 mm x 3 mm and providing DWC HDPE pipe for cable entry & exit as required for 3 m and 5 mtr pole.
13Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection,EMI EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).- 72 Watt
14Fabrication supplying and fixing Class B Galvanised Single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
15Providing and fixing of stainless steal name plate of size 6x8 sq inch made of 20 guage sheet including engraved name of area repersentative duly painted along with SS clamp nut bolt etc. as required.
16P/F of hot press sheet moulded compounded (SMC ) fire retardant ( Temp. resistance up to 200C) Ip -55 weather proof pole box of inner dimension 200X160X98 mm complete with suitable arrangement for fixing of 2 nos. of 6 to 32 Amp. Single pole MCB & 63 a double pole isolator ( MCB and isolator excluded) with nutral link duly shorting on DIN channel with 2 nos of clamp wit ss back plate of suitable size with Danger Monograme & SDMC property printed on the cover ETC as required.
17Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098/1988 of following Sizes 2 X6 SQmm
18Providing and fixing name board made of MS Sheet 90x60 cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back othe sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30 embedded in CC block 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approval steel primar, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction Engineer-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58011262
AUTHORITY Local Bodies
TENDER VALUE 6.61 Lakhs
LAST DATE 23-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Installation Of 02 Nos. Boom Barrier At Main Entrance And Exit Gate For Old Mig Flats, Phase-I, Prasad Nagar Society In Ward No. 86 Under Karol Bagh Zone
Basic Detail
Tender No NIT No 36/EEE/KBZ/MCD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 13 Oct 2026
Submission Date 23 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 6.61 Lakhs
Tender Fee 590
EMD 13300
Exemption Not Available
Document List
BOQ_343131.xls
Condition.pdf
ee41d491-de16-492d-8c4d-5dea20ae6b7f.html
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_343131.xls

pdf

Condition.pdf

html

ee41d491-de16-492d-8c4d-5dea20ae6b7f.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender