Educational and Research Institute Boards / Undertakings / PSU Closing in 5 days TDR #58011176

Tender For Supply Installation Testing and Commissioning of Class 1000 And Class 10000 Cleanroom Facility At Iucaa, Pune

Issued by Boards / Undertakings / PSU · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Nov 2026
5 days left
EMD
9 Lakhs
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Class 1000 And Class 10000 Cleanroom Facility At Iucaa, Pune

BOQ

Name of Work:- SITC of Class 1000 and Class 10000 Cleanroom Facility at IUCAA, Pune
Sl. No. Item Description
1Outdoor Unit - 10 HP Top Discharge:-SITC of modular type Variable Refrigerant Flow/Variable Refrigerant Volume aircooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410a Refrigerant, vibration isolators with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The unit shall be suitable to work on 415V ± 10%, 3 Phase, 50Hz AC power supply. - The COP at AHRI conditions shall be as mentioned below. ODU Capacity Control must be minimum 13%. Compatible to sync with Fire Protection Systems and BMS system.Unit shall include support stand with two coat of enamel paint as per specification.The offered ODU model shall comply with all given technical specifications and technical specified specified in Annexures 1 & 2. BMS compatible to sync with Fire Protection Systems.SITC work include lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings.Sussecfull OEM has to confirm on the capacites as per their design & connected circuit IDU's. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. For each ODU, the bidder is required to supply a 4-pole 100/300 mA ELMCB with an IP65 enclosure of the suitable current rating, along with all necessary cabling, cable glands, lugs and end terminations etc. complete.
2Outdoor Unit - 12 HP Top Discharge :-SITC of modular type Variable Refrigerant Flow/Variable Refrigerant Volume aircooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410a Refrigerant, vibration isolators with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 52°C ambient temperature without tripping. The unit shall be suitable to work on 415V ± 10%, 3 Phase, 50Hz AC power supply. - The COP at AHRI conditions shall be as mentioned below. ODU Capacity Control must be minimum 13%. Compatible to sync with Fire Protection Systems and BMS system.Unit shall include support stand with two coat of enamel paint as per specification.The offered ODU model shall comply with all given technical specifications and technical specified specified in Annexures 1 & 2. BMS compatible to sync with Fire Protection Systems.SITC work include lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings.Sussecfull OEM has to confirm on the capacites as per their design & connected circuit IDU's. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. For each ODU, the bidder is required to supply a 4-pole 100/300 mA ELMCB with an IP65 enclosure of the suitable current rating, along with all necessary cabling, cable glands, lugs and end terminations etc. complete.n
3AHU of 4500 CFM, Re-heat 8 kW (Heater 2 KW x 4 Nos) - with 180 mm Static Pressure EC Fans with 400 cfm De-Humidifier - 10 HP x 2 Nos. of CKT. :-SITC of factory build outdoor type Smart AHU Units including heaters/dehumidifier. The required conditions for the cleanroom are a temperature of 22°C ± 1°C and a relative humidity (RH) of 50% ± 5%. The AHU must feature BMS connectivity and include a 'manual operation' option as a standard feature. The inner skin 0.8 mm plain GI & outer skin 0.8 mm pre coated GI construction with 46 ± 2 mm thick and density of 96 ± 2 kg/m3 Rockwool insulation panel with internal coving & Thermal break profile. The coving should be an integral part of the frame and not applied separately. AHU shall be Thermal break. Frame work : Minimum 2 mm thick thermal break aluminium profile. Unit Base, Mixing Box for Return Air & Fresh Air, EU-4 - 90% down to 10 micron (IPD - 40 PA & Recommended FPD - 150 PA), AHU Supply fan shall be with Multipal electronically commutated (EC) motor & Fan, mounted on common antivibration base frame. Fan motor shall be suitable for BMS application. It shall consisting of IE5 EC motor, TEFC, IP55. Motor insulation shall be class F. High Efficiency Type with an operating Temperature range of 0 to + 80 Deg. C. Fan shall be as per AMCA latest standard including BMS ready programable controller. AHRI certified heat transfer coil. Dx/VRF Coil section with 8 row deep along with suitable VRF coil kit copper tubes and aluminium fins to be provided.The coil shall be pitched in the unit casing for proper drainage with Insulated 1.2 mm thick SS-304 drain tray with 13 mm thick insulation. Each coil shall be factory tested at 21 Kg/cm² (300 Psig) air pressure under water. Tube shall be mechanically expanded for minimum thermal contact resistance with fins. Fin spacing shall be 10 to 12 fins per inch (4 to 5 fins per cm). Minimum 600 mm mixing box be provided before cooling coil for access door & cleaning purpose of filter & coil. Tube Dia (mm / inch) : 9.5 mm for DX coil; Thickness of tube (mm) : 0.3 mm, Header Material: Copper, Thickness & Material of fins 0.15 mm Plain Aluminum, Coil Casing / Blank offs : SS-304, UV Light Provision Section + Cleaning Space Between coil & Heater Section with Space around 600 mm Electric Heaters. RIGID MEDIA Fine filter section EU5 Filter - 95% down to 5 μ of 305 mm thick filter after fan section. Fresh air, Supply, Return & Bleed air dampers shall be Aluminium Aerofoil opposed blade compatible for motorized operation (along with knob for manual operation), DP switch across each filters for measuring the pressure drops across the filters, Standard accessories like FLP Bulk head lamp, FLP limit switch.
4AHU of 7500 CFM, Re-heat 18 kW (Heater 3 KW x 6 Nos) - with 180 mm Static Pressure EC Fans with 800 cfm De-Humidifier - 10 HP x 3 Nos. of CKT :-SITC of factory build outdoor type Smart AHU Units including heaters/dehumidifier. The required conditions for the cleanroom are a temperature of 22°C ± 1°C and a relative humidity (RH) of 50% ± 5%. The AHU must feature BMS connectivity and include a 'manual operation' option as a standard feature. The inner skin 0.8 mm plain GI & outer skin 0.8 mm pre coated GI construction with 46 ± 2 mm thick and density of 96 ± 2 kg/m3 Rockwool insulation panel with internal coving & Thermal break profile. The coving should be an integral part of the frame and not applied separately. AHU shall be Thermal break. Frame work : Minimum 2 mm thick thermal break aluminium profile. Unit Base, Mixing Box for Return Air & Fresh Air, EU-4 - 90% down to 10 micron (IPD - 40 PA & Recommended FPD - 150 PA), AHU Supply fan shall be with Multipal electronically commutated (EC) motor & Fan, mounted on common antivibration base frame. Fan motor shall be suitable for BMS application. It shall consisting of IE5 EC motor, TEFC, IP55. Motor insulation shall be class F. High Efficiency Type with an operating Temperature range of 0 to + 80 Deg. C. Fan shall be as per AMCA latest standard including BMS ready programable controller. AHRI certified heat transfer coil. Dx/VRF Coil section with 8 row deep along with suitable VRF coil kit copper tubes and aluminium fins to be provided.The coil shall be pitched in the unit casing for proper drainage with Insulated 1.2 mm thick SS-304 drain tray with 13 mm thick insulation. Each coil shall be factory tested at 21 Kg/cm² (300 Psig) air pressure under water. Tube shall be mechanically expanded for minimum thermal contact resistance with fins. Fin spacing shall be 10 to 12 fins per inch (4 to 5 fins per cm). Minimum 600 mm mixing box be provided before cooling coil for access door & cleaning purpose of filter & coil. Tube Dia (mm / inch) : 9.5 mm for DX coil; Thickness of tube (mm) : 0.3 mm, Header Material: Copper, Thickness & Material of fins 0.15 mm Plain Aluminum, Coil Casing / Blank offs : SS-304, UV Light Provision Section + Cleaning Space Between coil & Heater Section with Space around 600 mm Electric Heaters. RIGID MEDIA Fine filter section EU5 Filter - 95% down to 5 μ of 305 mm thick filter after fan section. Fresh air, Supply, Return & Bleed air dampers shall be Aluminium Aerofoil opposed blade compatible for motorized operation (along with knob for manual operation), DP switch across each filters for measuring the pressure drops across the filters, Standard accessories like FLP Bulk head lamp, FLP limit switch.
5AHU of 10000 CFM, Re-heat 24 kW (Heater 3 KW x 8 Nos) - 180 mm Static Pressure EC Fans with 1000 cfm De-Humidifier - 12 HP x 3 Nos. of CKT.:-SITC of factory build outdoor type Smart AHU Units including heaters/dehumidifier. The required conditions for the cleanroom are a temperature of 22°C ± 1°C and a relative humidity (RH) of 50% ± 5%. The AHU must feature BMS connectivity and include a 'manual operation' option as a standard feature. The inner skin 0.8 mm plain GI & outer skin 0.8 mm pre coated GI construction with 46 ± 2 mm thick and density of 96 ± 2 kg/m3 Rockwool insulation panel with internal coving & Thermal break profile. The coving should be an integral part of the frame and not applied separately. AHU shall be Thermal break. Frame work : Minimum 2 mm thick thermal break aluminium profile. Unit Base, Mixing Box for Return Air & Fresh Air, EU-4 - 90% down to 10 micron (IPD - 40 PA & Recommended FPD - 150 PA), AHU Supply fan shall be with Multipal electronically commutated (EC) motor & Fan, mounted on common antivibration base frame. Fan motor shall be suitable for BMS application. It shall consisting of IE5 EC motor, TEFC, IP55. Motor insulation shall be class F. High Efficiency Type with an operating Temperature range of 0 to + 80 Deg. C. Fan shall be as per AMCA latest standard including BMS ready programable controller. AHRI certified heat transfer coil. Dx/VRF Coil section with 8 row deep along with suitable VRF coil kit copper tubes and aluminium fins to be provided.The coil shall be pitched in the unit casing for proper drainage with Insulated 1.2 mm thick SS-304 drain tray with 13 mm thick insulation. Each coil shall be factory tested at 21 Kg/cm² (300 Psig) air pressure under water. Tube shall be mechanically expanded for minimum thermal contact resistance with fins. Fin spacing shall be 10 to 12 fins per inch (4 to 5 fins per cm). Minimum 600 mm mixing box be provided before cooling coil for access door & cleaning purpose of filter & coil. Tube Dia (mm / inch) : 9.5 mm for DX coil; Thickness of tube (mm) : 0.3 mm, Header Material: Copper, Thickness & Material of fins 0.15 mm Plain Aluminum, Coil Casing / Blank offs : SS-304, UV Light Provision Section + Cleaning Space Between coil & Heater Section with Space around 600 mm Electric Heaters. RIGID MEDIA Fine filter section EU5 Filter - 95% down to 5 μ of 305 mm thick filter after fan section. Fresh air, Supply, Return & Bleed air dampers shall be Aluminium Aerofoil opposed blade compatible for motorized operation (along with knob for manual operation), DP switch across each filters for measuring the pressure drops across the filters, Standard accessories like FLP Bulk head lamp, FLP limit switch.
6Supply, installation, testing and commissioning of AHU Electronics Expansion and Control Kit supplied by VRF / VRV OEM only as per required ODU capacity with all required accessories complete.
7The remote Control panel wall mounted in Lab 1 / 2 /3, It shall be fabricated from 18 G MS CRCA sheet, duly powder coated, with seven tank process, with vermin proof gasketed doors. Following operation are required from remote panel - AHU and VRF system shall be start/stop in sequence with single ON/OFF switch. ON/OFF/TRIP status on panel. Actual temperature display for return air duct. Suitable duct type temperature sensor shall be provided by bidder. Panel should have bottom entry for cable connection. GA drawing for panel to be submitted to IUCAA for approval before fabrication.
8Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of required sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with 32 mm XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required.Note-1) 100% Piping pair shall be laid with suitable size 18G perforated Cable Tray. The All Outdoor exposed piping must be provided with tray cover. 2) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (3) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (4) The makes of tube fittings shall be same as that of tubes. (5) The thickness of fittings used shall be same as that of the pipe. (6) All insulation joints must be covered with EPDM Rubber Tape
9SITCof hot dipped galvanised perforated type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.for copper piping. Tray shall be covered with cover made from GI. Tray shall be fixed and laid properly along the wall / Floor with MS Hanger supports.
10SITC of 3/4 Core x 1.5 Sq mm copper shielded cable, between AHU and ODU, between remote panel and AHU, between temp sensor & remote panel, AHU limit switches, etc. for necessary communication and controls. Cable of appropriate size and specifications to be selected as per recommendations from OEM. Cable shall be laid through 25 mm PVC HMS FRLS conduit with all required accessories.
11SITC of of 50 mm dia UPVC drain pipe with fittings, supports & 9 mm Nitrile Rubber Insulation having pressure holding of 10 kg/cm2. Drain piping complete with all accessories. U-PVC drain pipe with all necessary fittings and Pipe to be installed properly using supports/saddles.
12Provide and install galvanized MS stand for VRF outdoor units, minimum 450 mm above FFL. Structure must include anti-vibration pads and be anchored using fasteners. All components must be corrosion-resistant. Stand shall be painted with two coats of primer and two coats of enamel paint.
13Anti vibration Shore hardness rating of 45 to 65 durometer, engineered for optimal static deflections capable of handling loading pressures from 40 up to 180 PSI (2.8 to 12.6 kg/cm²) without collapsing or bottoming out for Minimum vibration and noise insertion loss of 65 to 25 dB, matching or exceeding industrial compliance standards
14Nitrogen testing and vacuuming of entire refrigerant piping as per OEM recommendation for 24 Hrs @ 600 Psi
15Charging of suitable refrigerant gas after vacuuming of system @ 500 Microns, as per OEM recommendation
16SITC of 22 Guage rectangular GI sheet metal ducting minimum 180 GSM zinc coating both sides, fabricated to IS-655, 100% MS/TDF angle-flange joints, 3 mm neoprene/fire-retardant gasket, silicone sealed airtight joints, reinforcement, turning vanes, splitters, VCDs, access doors and supports. No slip joints. Include leakage test at minimum 500 Pa with results within approved limits. GI hardware, necessary supports etc. for connecting duct branches with AHU supply air planum, return air box and any other misc as per the site requirements. Flanges are to be fabricated as per SMACNA standard and sealed with silicon. Duct to be designed by contractor as per site condition. Earthing jumper links to be provided at each ducting joint and SITC of RTV Silicone Sealant for all duct joints
17SITC of 20 Guage rectangular GI sheet metal ducting minimum 180 GSM zinc coating both sides, fabricated to IS-655, 100% MS/TDF angle-flange joints, 3 mm neoprene/fire-retardant gasket, silicone sealed airtight joints, reinforcement, turning vanes, splitters, VCDs, access doors and supports. No slip joints. Include leakage test at minimum 500 Pa with results within approved limits. GI hardware, necessary supports etc. for connecting duct branches with AHU supply air planum, return air box and any other misc as per the site requirements. Flanges are to be fabricated as per SMACNA standard and sealed with silicon. Duct to be designed by contractor as per site condition. Earthing jumper links to be provided at each ducting joint and SITC of RTV Silicone Sealant for all duct joints
18Supply, Installation testing and commissioning of MS Flanges 40 x 40 x 5mm thick for rectangular GI ducting with anchor fasteners, hardware, necessary supports etc. for connecting duct branches, planum, return air box and HEPA Filters as per the site requirements. Flanges are to be fabricated as per SMACNA standard and sealed with silicon
19SITC of thermal insulation of Ducting, with cross linked polyphenoic backed by GC Cloth on one side class 'O' Class 25 mm thickness and other side with suitable adhesive at site SR505/SR998. Joints are overlapped with aluminium foil self adhesive aluminium tapes.
20Supply, Installation, Testing & Commissioning of thermal Insulation of 32 mm nitrile rubber insulation, class 'O' for fire, with factory fitted aluminium foil, bonding with class 'O' adhesive. Further it shall be covered with 0.5 mm thick aluminium cladding. This is to be used for the main ducting located outside the laboratory and exposed to the atmosphere.
21SITC of 16 gauge Alluminium profile volume control dampers. Air volume control dampers shall be of the aerofoil, double skin, opposed blade type with low pressure drop and noise regeneration characteristics. Blades shall be of hollow section constructed from the same material of the ductwork or of stainless steel encapsulating an internal double contoured stud longitudinal reinforcing bar, mounted on square section steel spindles. Bearings shall be of nylon material and the units shall be of low-leakage design by incorporation of synthetic trailing edge seals and a peripheral gasket. All manually and automatically operated dampers shall include a means for indicating externally the position of the blades. Manual dampers shall include a device for positioning and locking the damper blades. VCDs shall have open/close positions marked clearly.
22SITC of Fire (Smoke) Damper UL 555 Stamped with spring return actuator of appropriate size of duct. Operation of AHU shall be interlocked with the Fire Damper.
23Suitable Actuators with Control Panel and Fire Sensor for Item No. 22
24Supply, Installation, Testing of 125 mm deep antivibration flexible joints at the outlet of air handling units. Flexible connections shall be constructed using imported fire retardant fabric with extruded aluminium frame/flange on both sides.
25Providing & Fixing suitable size of MS stand / supports for AHU, ducting, piping, any additional supports. MS supports shall be duly painted with one coat of zinc oxide, primer and two coats of oil enamel paint.
26SITC of H14 terminal HEPA filter, minimum 99.995% efficiency at MPPS, deep-pleat micro-glass media, individually tested/certified, gel/gasket seal, low-leakage cleanroom construction, test port and initial pressure-drop/airflow certificate. Include installed integrity/leak testing. 610 x 610 x150 mm - Supply 1000 CFM
27Supply and installation of supply air terminal module made out of 18G SS-304 construction with filter fixing from bottom side DP checking port and canvas connection. The module gasketed/gel-seal compatible, cleanroom flush diffuser face, test port, access/inspection provision, suspension/support hardware and sealed ceiling interface - 610 x 610 x 450 mm - Supply 1000 CFM (Side Connection)
28Supply and installation of 1 mm thick latch type SS 304 perforated/louvered flush diffuser face with adjustable airflow provision where applicable, removable for filter access, smooth non shedding finish. grill for supply HEPA terminal box
29Low-leakage motorized GI dampers with suitable actuator, manual override, end-position indication, fail-safe action where required and BMS/DDC interface.
30Suitbale Actuator and Control Panel for Item No. 29
31SITC of Differential pressure monitoring system for AHU consisits of magenehelic gauges with 0-100 Pa range
32SITC of High accuracy digital room temperature and RH indicator with transmitters cleanroom-compatible mounting, calibration certificate
33SITC of Differential pressure monitoring system for Rooms consists of magenehelic gauges with 0-100 Pa range complete with all required accessories
34Supply and installation of cleanroom-compatible SS 304 Garment Cubicle (Size: 900 W x 600 D x 2100 H mm). Fabricated from 1.2 mm thick SS 304 with brushed finish, crevice-free welded joints, full-length mirror, hanging rods, and integrated shoe rack. Complete with floor/wall anchoring, adjustable levelling feet, and cleanroom grade silicone perimeter sealing.
35Clean Room Panel programming & integration : Complete programming and integration of AHUs, VRV/VRF, dehumidifier, heater bank, dampers, sensors, alarms, interlocks, schedules, sequences, graphics and trends. Include point-to-point testing and functional performance testing.
36Validation & Documentation : Duct leak test, HVAC documentation including DQ, IQ, OQ & PQ Certificates of all manufactured items and validation, training & final handover, includes - a) Air balancing, b) Air velocity, c) Particle count At rest condition, d) Recovery test, e) Air flow pattern and video graphic, f) HEPA Filter Integrity test
37SITC of 80 mm thick, factory-made Polyisocyanurate (PIR) insulated sandwich wall panels having Fire-retardant and self-extinguishing Class B1 properties, core density approx. 40±2 kg/m³ comprising an FM-approved, self-extinguishing PIR rigid foam core, laminated between two 0.5 mm to 0.6 mm thick pre-painted galvanized iron (PPGI) skin sheets coated with 25 microns of cleanroom grade, chemical resistant polyester paint. The panels must feature a precise, factory-formed tongue-and-groove interlocking mechanism with integrated EPDM gaskets to ensure an airtight, thermal-bridge-free assembly, delivering high thermal efficiency, Thermal Conductivity must be 0.022 W/mK, a Class B1, fire rating, Water absorption must be under 1% to prevent moisture degradation, free from CFC/HFC and a completely flush, seamless surface, (Colour: As approved by IUCAA)
38SITC of 50 mm insulated PIR ceiling panels matching wall construction, having Fire-retardant and self-extinguishing Class B1 properties, core density approx. 40±2 kg/m³, double skin 0.5 to 0.6 mm inner and 0.5 to 0.6 mm outer pre-coated GI (PPGI) cleanroom finish, concealed suspension/support grid, perimeter angles, hangers, service cut-outs for HEPA Filters /light fittings / fire-alarm openings, sealants and trims. Rigid, level, washable and airtight with complete installation and testing. The panels must feature a precise, factory-formed tongue-and-groove interlocking mechanism with integrated EPDM gaskets to ensure an airtight, thermal-bridge-free assembly, delivering high thermal efficiency, Thermal Conductivity must be 0.022 W/mK, a Class B1, fire rating, Water absorption must be under 1% to prevent moisture degradation, free from CFC/HFC and a completely flush, seamless surface, (Colour: As approved by IUCAA)
39Single Door 1200 x 2100 mm for Class 1000 Cleanroom Entrance :-Supply of Scientific metallic doors designed to fit flush in the wall panel system or Brick walls on both sides with 1.2 mm thick Galvanised Plain Skin Pass sheets duly epoxy powder coated formed to Single rebait profile with maximum bending radius 1.2 mm. Door frames to be supplied in knock down form, Butt jointed for insert each other assembly a side. The shutters to be constructed from 0.8 mm thick Galvanised steel sheet press formed to provide a 46 mm thick fully flushed double skin shell with lock seam joints at style edges. The internal construction to behoney comb core paper craft for structural strength and flatness. The frames & shutters should have provisions for receiving all specified hardware and vision panels 350 x 700 (Double glazed). The Door to be provided with following dorset/yale make Hardware, 1. Stainless steel hinges 2. handle with push plate, morticed dead lock one side key, Standard arm door closer, Concealed tower bolt (for double door), Bottom auto drop seal and kick plate. Note that air curtains are to be installed above all the doors.
40Double Door 1800 x 2100 mm for Class 1000 Material Gate EntranceSupply of Scientific metallic doors designed to fit flush in the wall panel system or Brick walls on both sides with 1.2 mm thick Galvanised Plain Skin Pass sheets duly epoxy powder coated formed to Single rebait profile with maximum bending radius 1.2 mm. Door frames to be supplied in knock down form, Butt jointed for insert each other assembly a side. The shutters to be constructed from 0.8 mm thick Galvanised steel sheet press formed to provide a 46 mm thick fully flushed double skin shell with lock seam joints at style edges. The internal construction to behoney comb core paper craft for structural strength and flatness. The frames & shutters should have provisions for receiving all specified hardware and vision panels 350 x 700 (Double glazed). The Door to be provided with following dorset/yale make Hardware, 1. Stainless steel hinges 2. handle with push plate, morticed dead lock one side key, Standard arm door closer, Concealed tower bolt (for double door), Bottom auto drop seal and kick plate. Note that air curtains are to be installed above all the doors.
41Cleanroom-rated insulated airtight Emergency Exit Door with GI approved frame, perimeter gasket, drop seal, closer and panic/emergency hardware required; complete installation and functional testing - Single Door 900 X 2100 mm - Near Fire Exit Door
42SITC of ESD Vinyl Mat flooring 3 mm thick, Static dissipative vinyl mat (3 Layered) Material : Homogeneous composition with Black conductive layer sandwiched between two antistatic Layers. Thickness : 3 mm +/- 0.1 mm, Surface resistivity of top surface layer : 10^6 – 10^9 ohms/sq, Surface resistivity of middle layer : 10^3 - 10^5 Ohms/sq, Standard Supply - 2.0 Mtrs width X approx. 15 Mtrs Running length. Governing Specifications : BS 2050 / 1978IS 3462 / 1986. Two male and two female (i.e. total 4 connectors) with all required accessories one at each corner of the mat shall be provided. Static dissipative vinyl mat suitable for laboratory environments complete with conductive primer, copper grounding strips, and earthing connections. The flooring shall be low-VOC, low-dusting, impervious, chemically resistant, abrasion-resistant, and capable of controlled static charge dissipation. The system shall comply with applicable ESD standards, with electrical resistance and grounding performance as per approved manufacturer specifications.
43Supply and installation of a 100 mm high, 50 mm to 75 mm radius flush-integrated seamless ESD Vinyl coving at corners & junctions
44Supply and installation of ceiling panel hanging system with necessary accessories like turn buckles, theared rods, nut and bolts, T- grid etc. for all 3 Cleanrooms
45Supply and installation of Track for 80 mm wall panel made with 1.2 mm thick GI sheet and powder coating and necessary holes for fixing
46Supply & Fixing of extruded aluminium powder coated clip on type R 90 covings (Enlarged type) for the entire wall to ceiling and wall to wall.
47Supply and installation of 2D / 3D Corners including all required material & accessories
48Supply and applying of Class B1 fire rated silicone sealants for all the panel joints, coving, light cutouts for all 3 Cleanrooms
49Supply and Installation of Electrical Conduits with 25 mm dia HMS PVC pipe
50Site / factory made cutouts for Grills, Light, Pass box & HEPA terminals
51Site / factory made cutouts for Electrical Points, Data & Light Points, DB etc.
52Site / factory made cutouts for Doors, View Panel, Air shower
53Supply and Installation of L/C-Cap for covering cutouts of lighs, module, doors etc.,
54Riser duct panels with coupling to the main HVAC ducting, including removable openable push-fit type grill panels for cleanroom areas, fabricated from SS 304 complete with SS 304 fixing frame, gasket, and all necessary accessories, suitable for G-4 filter installation. Panels shall be installed 150 mm above finished floor level (FFL) and provided with front-access volume control dampers. A suitable top flange shall be provided for duct connection, with adequate stiffeners to prevent buckling. Sizes shall be as specified. Return Air Riser Module Size : 600 MM W x 150 MM D x 3000 MM L
55Riser duct panels with coupling to the main HVAC ducting, including removable openable push-fit type grill panels for cleanroom areas, fabricated from SS 304 complete with SS 304 fixing frame, gasket, and all necessary accessories, suitable for G-4 filter installation. Panels shall be installed 150 mm above finished floor level (FFL) and provided with front-access volume control dampers. A suitable top flange shall be provided for duct connection, with adequate stiffeners to prevent buckling. Sizes shall be as specified. Pre - Filter Size : 600 x 300 x 50 MM
56Riser duct panels with coupling to the main HVAC ducting, including removable openable push-fit type grill panels for cleanroom areas, fabricated from SS 304 complete with SS 304 fixing frame, gasket, and all necessary accessories, suitable for G-4 filter installation. Panels shall be installed 150 mm above finished floor level (FFL) and provided with front-access volume control dampers. A suitable top flange shall be provided for duct connection, with adequate stiffeners to prevent buckling. Sizes shall be as specified. Perforated SS 304 Return air grilles for above Risers, Grill Size : 600 x 300 MM
57Supply, installation, testing & commissioning of SS 304 with 1.2 mm Sheet thickness, Air Shower suitable for cleanroom entry, complete with all accessories, sensors and controls.1. Size: 1800(W) × 1800(D) × 2100(H) mm.OUTER Size 2. Construction: Double - Skin SS 304 panels, smooth and cleanroom-compatible.4. Doors: Two SS 304 glazed doors with electromagnetic interlocking and emergency release.5. Air System: High-pressure centrifugal blower with adjustable SS 304 air nozzles on side walls and ceiling.6. Air Velocity: 20–25 m/s at nozzle outlets.7. Filtration: Pre-filter followed by H13 HEPA filter, minimum 99.97% efficiency at 0.3 micron.8. Floor: SS 304 perforated/grating floor with suitable load-bearing arrangement.9. Controls: PLC/digital control panel with adjustable shower timer, door interlocking and safety controls.10. Lighting: Flush-mounted cleanroom LED light.11. Accessories: Differential pressure gauge, SS 304 hardware and complete electrical/control accessories.12. Finish: Smooth, crevice-free, easy-to-clean and low-particle-generating internal surfaces.
58Supply, installation, testing & commissioning of SS 304 with 1.2mm thickness Air Curtain suitable for cleanroom entry, complete with all accessories, sensors and controls. Stainless Steel Air Curtain is built for Cleanroom entrances of 1800 mm wide, Body Material : SS304 With 6 blowers and 3 motors, 1490 CFM, Air velocity of 21 to 25 m/s, Max. Noise Level : not more than 70db, Blower Material : Galvanise Steel / SS304, built to maintain consistent air velocity across wide openings, Effective Height – Below 11 Feet, Finish : Smooth, crevice-free, easy-to-clean and low-particle-generating internal surfaces.
59Supply, installation, testing & commissioning of SS 304 with 1.2mm thickness Air Curtain suitable for cleanroom entry, complete with all accessories, sensors and controls. Stainless Steel Air Curtain is built for Cleanroom entrances of 1200 mm wide, Body Material : SS304 With 4 blowers and 2 motors, 1100 CFM, Air velocity of 21 to 25 m/s, Max. Noise Level : not more than 70db, Blower Material : Galvanise Steel / SS304, built to maintain consistent air velocity across wide openings, Effective Height – Below 11 Feet, Finish : Smooth, crevice-free, easy-to-clean and low-particle-generating internal surfaces.
60Supply, installation, testing & commissioning of SS 304 with 1.2mm thickness Air Curtain suitable for cleanroom entry, complete with all accessories, sensors and controls. Stainless Steel Air Curtain is built for Cleanroom entrances of 900 mm wide, Body Material : SS304 With 3 blowers and 2 motors, 825 CFM, Air velocity of 21 to 25 m/s, Max. Noise Level : not more than 70db, Blower Material : Galvanise Steel / SS304, built to maintain consistent air velocity across wide openings, Effective Height – Below 11 Feet, Finish : Smooth, crevice-free, easy-to-clean and low-particle-generating internal surfaces.
61SITC of Recess Mount Bottom Opening Clean Room LED Luminaire 60/80 Watt with SS304 Bottom frame, neutral white, IP65, 240 volt, 50 Hz, mounting provision through adjustable mounting clamps 4 Nos., including LEDs ,driver and all required accessories mounted and pre-wired up terminal block etc.
62Supply, Installation, Testing and Commissioning of an addressable Fire Alarm Control Panel (FACP) including battery backup set expandable upto 4 Loop in one enclosure equipped with a high-resolution, high-contrast graphic Blue LCD display of 240X64 pixel with 7 character in line. The panel must have two built-in inputs, two built-in NAC's and operate on 100-250V AC with 50-60 Hz and an inbuilt charger. The FACP should have sufficient loop numbers with 10% spare capacity and built-in loop isolators at both ends. It should have a loop load current capacity of 900mA, capable of supporting 250 devices with 125 addresses per loop using smart addressing. The system should support a maximum of 32 FACP and 128 loops in the entire network.The FACP should have redundant communication ports for networking and support peer-to-peer multimaster networking with RS422/485, TCPIP, MM Fiber, mix interface (fiber optic and 422) with a single or dual ring or mesh network communication platform. It must support broadcast options to transmit the configuration file to all available panels in the network. The system should allow for monitoring and viewing of each device from other panels connected in the network with seamless connectivity throughout. It should have a single processor for each 512 devices as per EN54 standards. The FACP shall support third party BMS/SCADA/DCIM facility using RS232, RS422, FO, TCP IP interface with Modbus RTU, ESPA protocol. It should support an inbuilt or external printer if required and shall be suitable for a single FACP or network for 384 zones, 512 I/O groups output groups with shared cause and effect on the network.The FACP should have optional provision of NFC Key for evacuation, disable the selected detectors, user-level access, reset and disablement features. It must support free license for the configuration software on MAC, windows 8, 10 & 11 higher based platform without any dongle support. The panel should have an inbuilt mini USB (type B) Port to upload and download the configuration and log entries. It should support soft tools to view and extract all history events, and the panel shall be suitable for a minimum of 10,000 log event record facility. The FACP must be forward and backward compatible with older devices of the same make.
63Supply, Installation, Testing & Commissioning of intelligant Addressable Multisensor (Smoke & Heat combined) detector with mounting base having capacity of min 125 detectors per loop. The detector must be polarity insensitive & smart addressable type. Detector must have have insect protection facility for aints and flyes with extra metalic mesh pattern. Operating temperature (Transient) -10°C to 85°C & Humidity 0-95% (Non-condesation or icing). The detector should have dual polling 360 degree viewable LED with class approved response modes for smoke & response heat modes as per the EN54 part 5 & 7 approval.The detector should trigger heat alarm to 55, 65, 75 or 85°C .The detector shall have facility to mount in different comprehensive environment like Hostile environment, Precious and normal working environments. The detector should have self locking mechanism, which can be easily removed.The detector must have non volatile memory to feed the installation date & site codes. It should be made up of ABS material -Flame retardant 94V0 rated & should melt above 200 degree C.The terminals for the base and the detector must be nickel plated steel to avoid the corrossion and to ensure the connectivity. The detectors must be openable for the cleaning whenever required. All the other specs should be as per the specification attached.
64Supply, Installation, Testing & Commissioning of Loop isolation module which consists of amber LED. This LED shall be mounted with in a round polycarbonate encloser. The isolator should responds if there short ckt on In side or out side with different LED'S All the other specs should be as per the specification attached.
65The addressable wall mounted Open Area Sounder with Beacon shall provide an output of 100dB at 1 meter and should have a low current consumption. The light intencity of the beacon should be 15 Cd. It should have choice to setup 4 tones. It must have shadow mode where sounder will not occupy any address on addressable loop. Sounder must have group addressing capability with shadow mode. IP Rating : Minimum IP 21C.Sound level must be 100 dB(A). Operating temperature : -10 to 70 degree C. The sounder must be made up ABS material (Flame retardant 94 V0 rated). Humidity 0-95%.(Non-condesation or icing). All the other specs should be as per the specification attached.
66Supply, Installation, Testing & Commissioning of Dust and Vermin proof analogue addressable Indoor Manual call point with hinged cover having enhance front reset mechanism with 170° viewable LED which can be visible from the minimum distance of 7 M. operating temperature from -10°C to 55°C to initiate audio visual alarm in case of Human detection of fire. The manual call point must be indoor type with IP 24D as per BS5839 standards. The Manual call point must be ressatable type without breakglass. The MCP must be made up ABS material (Flame retardant 94 V0 rated) & should melt above 200 degree C. All the other specs should be as per the specification attached.
67Supply and laying of 2 C x 1.5 Sq. mm, PVC insulated LSZH armoured copper cable with screen SLC Loop & Power Supply, confirming to BS 6387 categary C standards and specifications including terminations, connections & all labour and required accesseries/material etc. complete as required (For fire detection signal).
68SITC of Access Control & Attendance IP-based access control and time-attendance terminal featuring a minimum 3.2\\" TFT color display with a capacitive touchscreen interface, an IP65-rated ABS enclosure, and a scratch-resistant 500 DPI optical fingerprint sensor. The terminal accommodates minimum 40,000 user profiles, stores up to 500,000 event transaction logs, and supports authentication modes including Card Only, Finger Only, Card + Finger. Depending on the internal module configuration, its built-in RF card reader supports MIFARE, HID iCLASS, HID Prox, and EM Prox cards. Connectivity options include TCP/IP Ethernet, Wiegand (IN/OUT), RS-485/RS232, PoE (IEEE 802.3af), Wi-Fi, Bluetooth (BLE), and 3G/4G/GPRS, operating on a 12V DC / 2A power supply or PoE.
69Smart MiFare Cards
70SITC of Electromagnetic Lock - 600 LBS with all required accessories/hardware etc. complete
71SITC of Egress Switch (Exit Switch) with all required accessories
72SITC of 8 core twisted pair sheilded cable with all required accessories
73SITC of 5 Mega Pixel Indoor Dome camera with IR; Upto 5 MP HD Dome; Day & Night 1080P HD ; Focal Length – 2.8 ~ 12mm; Scanning System - Progressive Scan CMOS; Infrared Cut Filter - Auto / Schedule / Day (Color) / Night (Mono); Minimum Illumination - 0.01 Lux at F1.2 (Low Light Mode) ; Horizontal field of view : 95° to 31°, Vertical field of view : 50° to 18°, Diagonal field of view : 114° to 35°; IR Range-Up to 45 meter; Wavelength - 850 nm; Video Compression - Main stream : H.265/H.264Sub-stream : H.265/H.264/MJPEG; Max. Resolution-1920×1080; Image Enhancement - BLC, 3D DNR; Image Setting-Rotate mode, saturation, brightness, contrast, sharpness, AGC, white balance adjustable by web browser; Region of Interest-1 fixed region for main stream; Day/Night Switch - Day/Night/Auto/Schedule/Triggered by Alarm In (1in/1out); Network Storage - Support Micro SD/SDHC/SDXC card slot (512GB), Local storage and ANR; Alarm Trigger - Motion detection, video tampering detection, network disconnected, IP address conflict, SD cards full, SD card error; Protocols - TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, UDP, Bonjour; General Function One-key reset, mirror, password protection, privacy mask, API-ONVIF (PROFILE S, PROFILE G), Simultaneous Live View Up to 6 user; SMART STREAMING, ADAPTIVE STREAMING, reset Button, User/Host-Up to 10 users, 3 levels : Administrator, Operator and User; Web Browser - IE8+, Chrome 31.0-44, Audio- Built-in mic; Communication Interface-1 RJ45 10M/100M self -adaptive Ethernet port; Alarm 1 alarm input, 1 alarm output; On-board storage Built-in micro SD/SDHC/SDXC slot, up to 512 GB; Environment Noise Filtering - Yes, Audio Compression - G.711u/G.726Operating Conditions - 30 °C to 45 °C, Humidity : 95% or less (non-condensing); Power Supply -12 VDC ± 25%, PoE (802.3af, class 3), Protection Level - IP66, IK10, STQC, UL, NDAA, NEMA 4X
74SITC of NVR 16 Channel ; upto 02 SATA interfaces; 16 to 18TB capacity per HDD; USB 3.0; OnVif Compliant; HDMI output upto 1920x1080P resolution; H.264/H.265 Compression; Support Multiple VCA events; Network Interface : 1 port Ethernet (RJ-45) 10/100/1000Mbps, Alarm 2 in / 1 out, Operating Temperature 0°C to +50°C, Power Input Adapter 12V DC, Multiple Camera Viewing Through Cascading (up to 20 Devices), camera wise recording retention, Camera initiation, Instant calling from mobile App
75SITC of 16 TB Capacity Surveillance Hard Disk of Continuous Duty Type, multi camera support,
76SITC of Cat 6 UTP Jack with Strain relief and bend limiting boot & Shutter -White Camera / NVR Side
77Supply , Laying & Saddling of CAT 6A , U/UTP 23AWG, LSZH, 4 Pair Network Cable, Conductor dimension (mm) - 0.57 +/- 0.01 mm, Insulation Material - HDPE, Filler - Special Filler LSZH, Rated temperature: 75 ℃, Smoke Density – IEC 61034, Flammability Test – IEC 60332-1, PH and Toxicity Index – IEC 60754 P I & II. Note that the laying is to be done inside Ducts / Ceiling / Inner & Outer Walls at any heights / Rain Water Gutters/ Trenches etc. Rate should include resurfacing of damage or cutting of any civil structure or surface with painting etc and upto satisfaction of IUCAA supervision.
78SITC of 16-Port POE Switch with all required accessories
79SITC of Accessories (PVC Box, RJ Conn, flexible pipe, 6 UTP Jack, Cable Manager, fitting etc.)
80Supplying and laying HMS uPVC conduit FRLS grade 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring/wall/flooring including core cutting/drilling in RCC Slab/Concrete wall etc. as per site requirements.
81SITC of 9 U Network Rack with all standard accessories , shelves, PDUs, Cable Manager etc.
82SITC of required Software and integration of CCTV System
83SITC of LCD HD Ready resolution Monitor 22” with HDMI & VGA Ports with HDMI Cable of suitable length to view the CCTV recording With required Brackets & Supports and Power Cable
84SITC of Outdoor type IP55 Panels as per IEC standards and given specifications - Panel should be fabricated with CRCA sheets with 14 Gauge thickness, 2mm Load bearing and 1.6mm Non load bearing sections, 2.2mm Doors, 3mm Gland plate, Dust and vermin proof, Outdoor Installation, IP55, with minimum seven tank process powder coated with approved colour shade, Floor/Wall mounted, Bottom Cable entry, 3 phase, 50 Hz. 415 V with required switchgear, Protection, MFM, RYB/ON/OFF/TRIP LED Indicating Lamps for input & ON/OFF/TRIP LED Indicating Lamps for all outgoing branches, selector Switches etc. Abnormal voltage protection, etc. with 250 Amp. four pole MCCB with spreader links as main incomer and 11 Nos. four pole 25 to 63 Amp current rating MCBs for Each branch protection (Suitable current rating for ODU as per OEM's recommendations). The bidder shall arrange and bear all costs associated with the required testing of the panels at the factory prior to dispatch and again at the work site following installation. All tests shall be conducted in accordance with the applicable standards, specifications, and approved procedures.Panel builder must have workshop with latest ISO 9001 Certifications & shall have Calibrated testing setup for Routine test of LT Panels as per standards. Contractor to provide panel builder documents for verification.For LT panels, all the type tested certificates must be submitted by the OEM and issued in the OEM's name, in compliance with IEC standards. (For verification purposes, the contractor must make available the documentation from the panel builder and the OEM).
85SITC of Outdoor type IP55 Panels as per IEC standards and given specifications - Panel should be fabricated with CRCA sheets with 14 Gauge thickness, 2mm Load bearing and 1.6mm Non load bearing sections, 2.2mm Doors, 3mm Gland plate, Dust and vermin proof, Outdoor Installation, IP55, with minimum seven tank process powder coated with approved colour shade, Floor/Wall mounted, Bottom Cable entry, 3 phase, 50 Hz. 415 V with required switchgear, Protection, MFM, RYB/ON/OFF/TRIP LED Indicating Lamps for input & ON/OFF/TRIP LED Indicating Lamps for all outgoing branches LED Indicating Lamps, selector Switches etc. Abnormal voltage protection, etc. with 250 Amp. four pole MCCB with spreader links as main incomer and 9 Nos. four pole 16 to 63 Amp current rating MCBs for Each branch protection (Suitable current rating for AHU/Dehumidifier/Heater as per OEM's recommendations). The bidder shall arrange and bear all costs associated with the required testing of the panels at the factory prior to dispatch and again at the work site following installation. All tests shall be conducted in accordance with the applicable standards, specifications, and approved procedures.Panel builder must have workshop with latest ISO 9001 Certifications & shall have Calibrated testing setup for Routine test of LT Panels as per standards. Contractor to provide panel builder documents for verification.For LT panels, all the type tested certificates must be submitted by the OEM and issued in the OEM's name, in compliance with IEC standards. (For verification purposes, the contractor must make available the documentation from the panel builder and the OEM).
86SITC of 3.5C X 150 sqmm FRLS XLPE Insulated Aluminium armoured cable laying in Existing RCC Pipe including removing/breaking of cement concrete, liftting/shifting of Heavy duty 1.2 Meter X 1.5 Meter RCC covers and restore again complete work as required. Consider crane/JCB expenditure as required.
87SITC of End Termination of 3.5C X 150 sqmm FRLS XLPE Insulated Aluminium cable with required material Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
88SITC of FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 Core 10 Sq. mm. copper multistrand conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as required complete
89SITC of End Termination of 4C x 10 Sq. mm Copper multistrand cable with required material Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
90SITC of FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 Core 6 Sq. mm. copper multistrand conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as required complete
91SITC of End Termination of 4C x 6 Sq. mm Copper multistrand cable with required material Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
92SITC of FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 Core 4 Sq. mm. copper multistrand conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as required complete
93SITC of End Termination of 4C x 4 Sq. mm Copper multistrand cable with required material Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
94SITC of FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 Core 2.5 Sq. mm. copper multistrand conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as required complete
95SITC of End Termination of 4C x 2.5 Sq. mm Copper multistrand cable with required material Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
96SITC of FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 Core 1.5 Sq. mm. copper multistrand conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as required complete
97SITC of End Termination of 4C x 1.5 Sq. mm Copper multistrand cable with required material Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
98SITC of 40 X 5 mm Copper earthing strip with Epoxy Resin Support Insulator, Wall Mount type, rated voltage - 1.1 kV, Creepage Distance - 50mm mounting on PIR wall panel at every 0.75 Mtr. with all required hardware/accessories as complete.
99SITC of FRLS XLPE insulated cable 1100 V, 1 Core 70 Sq. mm. copper multistrand (Green colour) conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as required complete
100SITC of End Termination of 1C x 70 Sq. mm Copper multistrand cable with required material long barrel bimetallic Lugs, double compressed Glands, Nut-Bolts & accessories etc. complete
101Disconnecting terminated cables/wires, removing existing DB panels from the wall, mounting the removed DB panels onto the cleanroom PIR panel wall, and re-terminating the disconnected cables/wires including tasks such as cutting/slotting and airtight sealing with Class B1 fire-rated silicone gel as required complete
102Disconnecting terminated cables/wires, removing existing raw / UPS Power Points and Lighting Switcboards from the wall, mounting the removed Power Points and Lighting Switcboards onto the cleanroom PIR panel wall, and re-terminating the disconnected cables/wires including tasks such as cutting/slotting and airtight sealing with Class B1 fire-rated silicone gel as required complete
103Disconnecting terminated CAT6A cables & Telephone wires, removing existing Data & Telephone points/boards from the wall, mounting the removed Data & Telephone points/boards onto the cleanroom PIR panel wall, and re-terminating the disconnected CAT6A cables and Telephone wires including tasks such as cutting/slotting and airtight sealing with Class B1 fire-rated silicone gel as required complete Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58011176
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 03-11-2026
Authority
Authority Name Inter-University Centre For Astronomy And Astrophysics
Work Description Tender for Supply Installation Testing and Commissioning of Class 1000 And Class 10000 Cleanroom Facility At Iucaa, Pune
Basic Detail
Tender No M26-0386
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 13 Oct 2026
Submission Date 03 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 2360
EMD 9 Lakhs
Exemption Not Available
Document List
590d830f-388e-448a-9a49-45c225b9e62a.html
Annexure_BOQ.pdf
BOQ_977395.xls
TechnicalBid.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

590d830f-388e-448a-9a49-45c225b9e62a.html

pdf

Annexure_BOQ.pdf

xls

BOQ_977395.xls

pdf

TechnicalBid.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender