Tender For Renovation Of The Mini Stadium Of Pm Shri Govt Sr. Sec. School, C Bell Bay.
Tender Value
2.03 Crore
Estimated cost
Bid Submission
27 Oct 2026
4 days left
EMD
4.06 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of The Mini Stadium Of Pm Shri Govt Sr. Sec. School, C Bell Bay.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 6 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 8 | Foundations, footings, bases for columns. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 10 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 14 | Foundations, footings, bases of columns, etc. for mass concrete |
| 15 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 19 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 21 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 22 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 23 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 24 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 25 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 26 | 250x16 mm |
| 27 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 28 | 250x10 mm |
| 29 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 30 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 31 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 32 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 33 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 34 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 35 | Fixed window / ventilator without mullion / transom |
| 36 | Using R1 series with frame (33mm & above ) x (35mm & above). (Height upto 0.90 meter) |
| 37 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 38 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 39 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 40 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 41 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 42 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 43 | Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. |
| 44 | Using R3 series with frame (55mm & above ) x (45mm & above) & sash (55mm & above) x (65mm & above) & mullion (55mm & above) x (65mm & above). (Height upto 1.8 meter). |
| 45 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 46 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 47 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 48 | Electric resistance or induction butt welded tubes |
| 49 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 50 | Providing and fixing bolts including nuts and washers complete. |
| 51 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 52 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 53 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 54 | G.I. pipes |
| 55 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 56 | 10 x 80 mm |
| 57 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 58 | 40 mm thick with 20 mm nominal size stone aggregate |
| 59 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 60 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 61 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 : 2000 |
| 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 63 | 75 mm diameter |
| 64 | 110 mm diameter |
| 65 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 66 | Coupler |
| 67 | 110mm |
| 68 | Bend 87.5° |
| 69 | 110 mm bend |
| 70 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. Theprofile sheets shall be fixed to truss members in slope or requiredpitch or curvature with Hex cap headed self drilling/tapping Stainlesssteel screws M6, 50 mm long with 3 mm EPDM seal washer etc. allinclusive of labour, scaffolding, T&P and sundries etc. complete asper directions of the Engineer-In-Charge. (Cost of truss/frame workshall be paid separately). |
| 71 | 0.71 mm Aluminium profile with center to center pitch of 177.5 mm, depth of 28.5 mm, 987mm overall profile width, cover width 900mm |
| 72 | Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : |
| 73 | Precoated/mill finish aluminium Ridges plain (500- 600mm) |
| 74 | Precoated/mill finish aluminium Flashings/ Aprons (Upto 600 mm) |
| 75 | Precoated/mill finish aluminium Gutter (600 mm over all girth) |
| 76 | 12 mm cement plaster of mix : |
| 77 | 1:4 (1 cement: 4 fine sand) |
| 78 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 79 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 80 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 81 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 82 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 83 | Two or more coats on new work |
| 84 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 85 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 86 | Repairs to plaster of thicknes 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Enngineer-in-Charge. |
| 87 | With cement mortar 1:4(1 cement : 4 fine sand) |
| 88 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. |
| 89 | Orissa pattern W.C Pan of size 580x440 mm |
| 90 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 91 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 92 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 93 | Of area 3 sq. metres and below |
| 94 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 95 | For thickness of tiles 10 mm to 25 mm |
| 96 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 97 | G.S. Sheet |
| 98 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 99 | 15 mm to 40 mm nominal bore |
| 100 | Above 40 mm nominal bore |
| 101 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 102 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 103 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 104 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 105 | Semi rigid pipe |
| 106 | 32 mm dia |
| 107 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 108 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 109 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
| 110 | 20 mm dia. nominal bore |
| 111 | 25 mm dia. nominal bore |
| 112 | 50 mm dia. nominal bore |
| 113 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 114 | 25 mm nominal bore |
| 115 | 20 mm nominal bore |
| 116 | 50 mm nominal bore |
| 117 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 118 | 45 cm length |
| 119 | 15 mm nominal bore |
| 120 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 121 | 20 mm nominal bore |
| 122 | 25 mm nominal bore |
| 123 | 50mm nominal bore |
| 124 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 125 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 126 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 127 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 128 | Concealed stop cock, 15 mm nominal bore, 108mm long. Weighing not less than 108 gms. |
| 129 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 130 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 131 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 132 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 133 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 134 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 135 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 136 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. |
| 137 | Providing hollow cement block walling upto floor level 200 mm thick consisting of using hollow block of size 400x200x200 mm of mix 1:3:6(1 Cement : 3 Coarse sand: 6 graded stone aggregate 20 mm nominal down size) having a crushing strength of 3.50N/mm2 at 28 days as per IS 2185(Part-I)1979 laid in cement Mortar 1:6 (1 Cement : 6 Coarse sand) complete. |
| 138 | Providing and fixing in position facia board and eaves board with 18 mm thick wooden plastic component(WPC) sheet i/c fixing with bnuts & bolts etc complete: 30cm width |
| 139 | Extra for providing and fixing aluminium wind ties of 40x6mm flat anodised aluminium section |
| 140 | Providing and fixing uPVC (SWR) Nahani trap with 110 mm inlet & 75 mm outlet of approved quality, colour & make including cost of cutting and making good the walls and floor complete. |
| 141 | Providing and fixing soil, waste and vent uPVC Pipe conforming to HSN code 3917 single socket-B,i/c fittings with solvent etc complete as per direction of engineer in charge solvent. |
| 142 | 110 mm dia. |
| 143 | 75 mm |
| 144 | Providing and fixing CP Brass 100mm diameter overhead shower with C.P 15 nominal bore 200 mm long arm pf approved quality |
| 145 | Supplying and installation of TABLE TENNIS (MODEL No. OCTEM ULTIMA CODE : OSTT02) of OCTEM SPORTING COMPANY Brand or equivalent including accessories & fixtures complete as per the direction of Engineer in charge. |
| 146 | Electrical Items |
| 147 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C |
| 148 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 149 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 150 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 151 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 152 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 153 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 154 | 3 x 1.5 sq. mm |
| 155 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 156 | 20 mm |
| 157 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 158 | 5/6 A switch |
| 159 | 3 pin 5/6 A socket outlet |
| 160 | 15/16 A switch |
| 161 | 6 pin 15/16 A socket outlet |
| 162 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 163 | 6 Module (200 mm x 75 mm) |
| 164 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 165 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 166 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 167 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 168 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 169 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) |
| 170 | 16 way , Double door |
| 171 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 172 | Single pole |
| 173 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 174 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 175 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 176 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 177 | Supplying of AC Ceiling Fan (1200 mm) Sweep with Socket Type Electronic regulator i/c wiring down rod of standard length (upto 30 cm) with all accessories etc., as required. Similar to make Crompton Empower 50 - 1 Star (ISI Marked) or its equivalent etc., as required as directed by Engineer-in-charge |
| 178 | Supplying of prewired LED tube lamp 20 W Essential Bright Batten Similar to make Philips Cat :BN170C LED20S-6500 SU L120 or Similar in make :Havels,Syska ,Bajaj,Crompton. etc as required and directed in Engineer-in-charge |
| 179 | Supplying and Fixing of LED Lamp 10W B22 of Make:Havells LED Adore10W or similar etc., as required for Batten Holder as directed by Engineer-in-charge |
| 180 | Supplying and fixing of Street Light luminaries 25 Wattage, with pressure die-cast housing along with prismatic polycarbonate optic with IP66 ingress protection with inbuilt surge protecton with top opening driver cover for easy maintenance similar to Havells Endura Sundown i/c clamping arrangement with GI Pipe of suitable size bending directly on the wall i/c connections etc as required as directed by the Engineer-in-charge |
| 181 | Supplying and Fixing of a multi-purpose steel industrial junction box with a flat face cover, IP65/IP66 proctection ratings, waterproof box with minimum size of 300 x 300 x 120 mm with DIN terminals/Busbars with 5 Nos. outgoing cable point for floodlights connection etc as requried as directed by the Engineer-in-charge |
| 182 | Supplying, Installation, Testing and Commissioning of Flood Light luminaries 100 Wattage, with pressure die-cast housing along with IP66 ingress protection flood light with inbuilt surge protecton suitable for highlighting area or general purpose lighting similar to Havells JETA ALBA i/c clamping arrangement directly on the rooftop i/c connections/termination etc as required as directed by the Engineer-in-charge |
| 183 | Supplying and fixing of SMC Sintex box of inside dimension 350 mm x 250mm x 138 mm similar to Code No. GSJB-3425, etc or equivalent make as required and directed by Engineer-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender