Tender For Special Repair To Building No. P-1 And Provision Of Lighting Conductor, 04 X Inverter Led Security Light 90Watt Alongwith Lt Pole & Connected Items, 04 X Split Air Conditioners At Patiala Under Ge (South) Patiala
Tender Overview
Project Description
Tender for Special Repair To Building No. P-1 And Provision Of Lighting Conductor, 04 X Inverter Led Security Light 90Watt Alongwith Lt Pole & Connected Items, 04 X Split Air Conditioners At Patiala Under Ge (South) Patiala
BOQ
| Sl. No. | Item Description |
| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | Taking down cement plaster of any description, any thickness from external/ internal surfaces of walls/soffits/ceilings etc. incl raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed. |
| 3 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc complete all as specified and directed. |
| 4 | M&L for fly ash Brick work with sub class 'B' bricks, class designation 100, old size bricks straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L for dubbing out average 10mm thick in CM 1:4 on irregular surface of soffits of slabs/Chajja/ Sunshades etc incl temorary provision of scaffolding etc complete all as specified and directed. |
| 6 | M&L for cement plastering 15mm thick in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 7 | Supply only integral liquid water proofing compound complete all as specified and directed. |
| 8 | M&L for 10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 9 | M&L for 5 mm thick cement plastering in cement mortar 1:3 on fair faces of concrete ceiling surfaces finished fair & even without using extra cement complete all as specified and directed. |
| 10 | Repair to RCC ceiling, sunshades, Chajjas, Balconies, Columns, bands, beams, roof slab and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. |
| 11 | M&L for complete removal of existing treatment of any type/ description from walls/ RCC surfaces/ ceiling/ chajjas/ roof projections etc with mechanical means/ grinder or manually (if directed) complete all as specified. |
| 12 | M&L for applying acrylic thick wall care putty on external/internal surfaces of walls/ceilings/soffits etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 13 | M&L for preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. |
| 14 | M&L for preparation of surfaces and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceilings surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. |
| 15 | M&L for preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. |
| 16 | Dismantling, floor, hearth or wall tiling including CM bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed |
| 17 | Demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and directed. |
| 18 | M&L for 25mm thick cement concrete work 1:2:4 using 12.5mm graded stone aggregates in sub-base to flooring etc complete all as specified and directed. |
| 19 | M&L for Full Body Vitrified Tiles joint free premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. over & including 20 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed. |
| 20 | M&L for Full Body Vitrified Tiles joint free premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in skirting/dado etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. over & including 10 mm thick rendering in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed. |
| 21 | M&L for machine cut kota stone slab (nearest to 58cmx58cm in size) flooring 18mm (+ 2mm) thick laid over and including 20-22 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 100mm wide border of Baroda Green Marble complete all as specified and directed. |
| 22 | M&L for machine cut kota stone slab (nearest to 58cmx58cm in size) skirting/dado 18mm (+ 2mm) thick laid over and including 10 mm thick rendering in cement mortar 1:4 as base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed. |
| 23 | M&L for Granite (Jet Black colour/shade-South Indian) of any type machine cut as in flooring, shelves/steps/counter tops, 18-20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive for fixing and bull nose on exposed sides/lengths complete all as specified and directed.Note : Single piece should be used in steps/cills/jambs/shelves. |
| 24 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints and filling the same with polyureathene complete all as specified and directed. |
| 25 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good to disturbed surfaces complete incl ventilators including reqd shape for hold fast block for new frame complete all as specified and directed. |
| 26 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed. |
| 27 | S&F door frames made of PPGI sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, stainless steel 150mm hinges 3 nos per frame, lock strike plate, hold fast etc., complete all as specified, size 125 x 60mm and incl cutting holes and making good reqd shape for hold fast block for new frame incl complete all as specified and directed. |
| 28 | M&L for cement concrete (1:2:4) using 12.50 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats, hold fasts etc., complete all as specified and directed. |
| 29 | Supply and fixing factory made flush shutters 30mm thick minimum 5 ply and laminated on both faces with laminate of approved shade, solid core construction, with block board core and plywood face panels, commercial type on both sides with 6mm thick lipping frame to match and PVC tape to matching the shade of laminate on the edges complete all as specified and as directed.” |
| 30 | S&F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated complete all as specified and directed.Note : Glass or wire cloth, etc. in panels or sash squares shall bemeasured separately. |
| 31 | S&F steel windows 1.25 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mmx25mm single rebated comprises of glazed and skeleton shutter EWR Sec 50mmx20mm and 1mm thick and two openable leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 for four nos for each window including S&F following fittings welded to each window :- (a) Holdfasts 150mm long 12mm x 3mm made to shape – 04 Nos per window (b) Handle of Z Sec 20mmx25mm, 100mm long – 1 Nos of leaf, (c) MS tower bolt 150mm long - 02 Nos per leaf (d) ‘Z’ sec 20mm x 25mm, 100 long stopper – 01 Nos per leaf, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges – 01 Nos per leaf (f) MS pintal hinges of size 75mmx12mm – 02 Nos per leaf (g) Fabrication and fixing arrangement complete.(h) Clear Glass 4 mm thick(j) Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm(k) Grill of 8mm sq. bar of length equal to the width of window @ 100mm c/c with cut space to accomodate the handle where directed/applicable. |
| 32 | S&F 50 micron powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 33 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and directed. |
| 34 | S&F Aluminium alloy anodised extruded fabricated type handle 150mm long complete all as specified and directed. |
| 35 | S&F Aluminium alloy, anodised, barrel tower bolt (bolt type) 150 mm long of extruded section or cast aluminium alloy and fixed complete all as specified and directed. |
| 36 | S&F Aluminium alloy anodised extruded fabricated type hinges 125mm in size complete all as specified and directed. |
| 37 | S&F stainless steel finished 202 Grade butt hinges 150mm long complete all as specified and directed. |
| 38 | S&F stainless steel 202 Grade finished 200mm long tower bolts in square shaped with minimum 10mm dia rod complete all as specified and directed. |
| 39 | S&F Stainless Steel 202 Grade Finished curved Handles 200 mm long complete all as specified and directed. |
| 40 | S&F Stainless Steel 202 Grade Finished Sliding Door Bolt/Aldrop 16 x 300mm with square nuckle complete all as specified and directed. |
| 41 | S&F 300mm, mild steel ordinary rat tail rod (helical type) pattern springs including roller and roller plate complete all as specified and directed. |
| 42 | M&L 4mm thick thoughened glass in ventilators/ windows/ doors fixed in any metal /aliminium frame work complete all as specified and directed. |
| 43 | S&F Stainless steel wire cloth, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 44 | M&L for preparing new wooden surfaces and applying two coats of synthetic enamal paint over one coat of pink wood primer complete all as specified and directed. |
| 45 | Taking down of existing iron door of size exc 1.5 sqm and n.exc 4.0sqm ans refixing the same after addition/ alteration of door like cutting in any shape/size as per Engr-in-charge directions etc and applying two coats of synthetic enamel paint over existing surfaces complete all as specified and directed. |
| 46 | M&L for preparing new steel and iron surfaces of any description and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 47 | S&F 25mm bore minimum 1mm thick stainless steel finished curtain rods inlcuding stainless steel finished brackets and stainless steel finished finials and end plugs etc of same manufacturer including screws/rawl plugs as specified by manufacturer for fixing complete fixed in position all as specified and directed. |
| 48 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed. |
| 49 | Demolition of mud phuska on roof any thickness including removal to the low lying area or outside the defence land complete all as specified and directed |
| 50 | M&L for roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 51 | M&L for PCC 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 ,complete all as specified and directed. |
| 52 | M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 53 | M&L for surface preparation by comprising of :(i) Concrete substrates must be prepared mechanically using abrasive blast cleaning equipment to remove cement laitance and achieve an open textured surface. Required minimum pull off strength is 1.5N/mm².(ii) Repairing surface irregularities, damaged concrete in base slab, if any, with an latex polymer, SBR Latex or equivalent modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools and tackles complete as specified and directed. |
| 54 | M&L for providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. |
| 55 | M&L for Plain Cement Concrete tiles 25cm x 25cm x 22-25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished laid over 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 56 | S&F PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc as in repairs after taking down existing damaged PVC rain water pipe complete all as specified and directed.Note : Clamps will be measured and paid separately. |
| 57 | S&F PVC (SWR) bends of any radius for 110mm bore complete all as specified and directed. |
| 58 | S&F for MS Clamps, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay) and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 59 | M&L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as in roof kerbs or mud stops and benching, rounded or chamfered on edges, coving shall be 150 mm in radius mixed with acrylic based polymer water proofing compound complete all as specified and directed. Note:WPC shall be paid separately |
| 60 | Taking up or down existing steel tubing and connections, 25mm bore complete all as directed and specified. |
| 61 | S&F 25mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as directed and specified. |
| 62 | S&F ISI marked doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including 20 mm dia brass float valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC water tank complete all as specified and directed. |
| 63 | S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for 25mm bore iron pipe or brass ferrule complete all as specified and as directed. |
| 64 | S&F in repair stainless steel sheet of 250mm wide and not less than 1mm thick as in crumple/ expansion joints complete all as specified and directed. |
| 65 | S&F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 66 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. any type complete all as specified and as directed. |
| 67 | Taking down unservesiable sub main wiring with conduits/battens etc complete all as specified and as directed. |
| 68 | Taking down unservesiable MCCB DBs, MCB DBs including MCCBs/TPN/SPN/SP etc complete all as specified and as directed. |
| 69 | M & L for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLS multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC concealed conduit, medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories including modular metal flush box with modular plate for mounting switches, sockets, fan regulators, etc and earth wire singlle core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLS cable as continuous earth wire connecting to common earth dolly in concealed wiring system including making good the disturbed surface of wall complete all as specified and directed for the following :- |
| 70 | One light point controlled by one switch one way complete all as specified and directed. |
| 71 | One ceiling fan/exhaust fan point controlled by one switch complete all as specified and directed. |
| 72 | One socket outlet 5 Amp controlled by one switch on independent board complete all as specified and directed. |
| 73 | One 3 pin 5Amps socket out let point on the same board controlled by one switch complete all as specified and directed. |
| 74 | All as per Srl item No 4 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed. |
| 75 | Supply and fixing in replacement of ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and as directed. |
| 76 | Supply and fixing white finished single mounting modular plates sutable for modular accessories of following sizes complete all as specified and directed.:- |
| 77 | Suitable for 2 modules |
| 78 | Suitable for 3 modules |
| 79 | Suitable for 8 modules |
| 80 | Supply and fixing of modular switch 1 way 6 Amps one module complete all as specified and directed. |
| 81 | Supply and fixing in replacement of modular socket 6 Amps 2/3 Pin combined 02 module complete, all as specified and directed. |
| 82 | Supply and fixing of modular switch one way 16 Amps, one module complete all as specified and as directed. |
| 83 | Supply and fixing of socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed. |
| 84 | Supply and fixing for lamp holder, PVC/poleycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed. |
| 85 | Supply and fixing of Indoor decorative LED battens- integrated Box type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified and directed. |
| 86 | Supply and fixing for LED Inverter bulb 10 watt of CFL 11/15 watt fixed in pendent holder/bulk head fitting complete all as specified and directed. |
| 87 | Supply and fix of LED bldg light 45 watt IP66 with internally prewired incl electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and directed. |
| 88 | Supply and fixing for sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed. |
| 89 | Supply and fixing in repalcement of vertical type load line distribution board, double door ,4 way , IP 43 IK08 AC, 3 phase, 415 volts, TPN bus bar and earth bar & din rail complete all as specified and as directed. |
| 90 | Supply and fixing for MCCB, 4 pole 40 A, 16KA, 415Volts complete all as specified and directed. |
| 91 | Supply and fixing in replacement of MCB, SP, 6-32A ,10KA complete all as specified and directed. |
| 92 | Supply and fixing in replacement of MCB, SPN, 40A ,10KA complete all as specified and directed. |
| 93 | Supply and fixing for sub main wiring with undermentioned run of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 V grade IS-694 drawing into and including rigid non metallic PVC conduit, medium grade ISI marked ( not less than 20 mm) with all conduit fittings & fixing accessories for concealed in wall/ ceiling or surface incl the specified run of specified size earth continuity conductor of similar type of cable complete all as specified and directed.Note- The undermentioned runs of single core cable and specified earth continuity conductor and revelent conduit with fitting acessories will be measured as one run. |
| 94 | 2 run of 2.5 sq mm and one run of 2.5 sq mm |
| 95 | 2 run of 4 sq mm and one run of 4 sq mm |
| 96 | Supply & Laying XLPE insulated screened bedded galvanied steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor 1100 V grade cross sectional area 35 sq mm 3.5 core complete all as specified and directed. |
| 97 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of Pipes, cables, poles,Stay and strips etc and getting out in Soft/Loose soil complete all as specified and directed. |
| 98 | Returning, filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. |
| 99 | Removing excavated material not exceeding 50m and depositing where directed at a level of not exceeding 1.5m above the starting point complete all as specified and directed. |
| 100 | Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed. |
| 101 | M&L for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable complete all as specified and directed . |
| 102 | M&L Earthing complete with galvanised steel earth plate electrode 600 mm x 600 cm x 6.00 mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including GI earth lead of GI wire 4.00 mmthick by means of steel bolts, nuts, check nuts and washers test points by GI pipe 40X8 mm 10 cm long,PCC 1:2:4 type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4type B-1 cover reinforced with 8 mm dia TMT bars @ 150 mm C /C both ways and 12 mm dia MS fabricated handle, mediam grade GI water pipe 20 mm bore with funnel, wire mesh and light gradeGI protection pipe 40 mm bore upto 5 M length for drawing in earth lead , salt charcol etc including excavation in earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete , all as shown in Electric plate No 3 of MES schedule 2009 Part-I and connected complete including testing on completion all as specified and directed. |
| 103 | S&F PVC fan AC single phase 230/240 V of size 250 mm sweep with louvers complete all as specified and directed. |
| 104 | Taking down ceiling fans & Exhaust of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades and deposit in MES store yard complete all as specified and directed. |
| 105 | Supply and install high wall inverter type split units indoor and outdoor complete with cordless remote control unit and with in built air filter for better indoor air quality with minimum 5 star rating single phase 240 Volts 50 HZs of 2 Ton complete with all fixing acessories.(a) Room evaporator indoor unit with speed blower fan of approipriate capacity including PCB , thremostatic control , air filter and drain for condensing water.(b) Outdoor condensing unit with condensor fan motor of appropriate capacity - 01 No. Air cooled condensor of capacity 2 TR - 01 No.Shall be installed outside the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installing of ACs.(c ) Refrigerant cooper pipe of suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit withy control valves & safety acessories invcluding complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable.(d) Making good the disturbed surface to match with the existing surface complete all as specified and directed.Make: Mitsubishi & O General |
| 106 | Supply and install Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 5 KVA complete all as specified and directed. |
| 107 | M&L for sub main wiring with two runs of 4 Sqmm (2x4 sqmm )1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC casing caping with all accessories fix in walls/roofs/floors etc with one run of 4 Sqmm (1x4 sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 4 Sqmm ,one run of 4 Sqmm ( 2x4 sqmm + 1x4 sqmm ) cable and one meter of conduit will be measured as one unit again. |
| 108 | Supply and fix of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. |
| 109 | Supply, installation, testing and commissioning of 1500 mm (5 feet) long commercial grade Air Curtain, suitable for installation above the entrance door of air-conditioned buildings to prevent ingress of dust, insects, hot air and to minimize conditioned air loss, complete with powder-coated aluminium/MS body, copper wound motor(s), cross-flow blower(s), minimum air velocity of 12–15 m/s, airflow suitable for effective air barrier, operating on 230V AC, single phase, 50 Hz supply, with minimum two-speed operation, ON/OFF switch, thermal overload protection, low noise operation, complete with wall mounting brackets, anchor fasteners, all internal wiring, power cable, necessary accessories, making electrical connections from the nearest available power point through suitable size copper conductor PVC insulated cable in PVC conduit, testing, commissioning and handing over complete in all respects as specified and directed. The unit should be suitable for door openings up to 1500 mm width and installation height up to approximately 3.0 m |
| 110 | S&F single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed. |
| 111 | S&F aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed. |
| 112 | M&L Earthing of machinery/equipment Installed at power house/substation, using 32 x 6 mm galvanized strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode complete all as specified and directed. |
| 113 | S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. |
| 114 | S&F lay pipe galvanized, “Medium class”, including fittings 40 mm (1.5”) dia complete all as specified and directed. |
| 115 | S&Fgalvazised iron strip 32mm x 6mm burried in ground/wall complete with saddles and fixing screws for fitting the strip complete all as specified and directed. |
| 116 | M & L for fire fighting stand of standard size made of MS angle iron, Channel, sheets and painted with two coat of synthetic enamel paint red colour over a coat of red oxide primer and writing \\" FIRE POINTS-KEEP ACCESS CLEAR\\" with white enamel paint as per standard size of word with necessary PCC and brick work platform including fabrication works etc complete all as specified and as directed and providing and fixing of following items. (i) Galvanised MS fire bucket 14 ltrs capacity -04 Nos(ii) Fire beater -02 Nos(iii) Fire hook - 02 Nos(iv) Shovel - 02 Nos(v)Hand siren -02 No(v) ISI marked (IS:15683) dry chemical fire extinguisher, powder (ABC) type capacity 6 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets - 2 No(vi) ISI marked (IS:15683) Mechanical foam extinguisher 9 Ltrs capacity - 2 Nos(vii) ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. - 2 No(viii) ISI marked (IS:15683) Fire Extinguisher water CO2 stored pressure type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets - 2 No |
| 117 | Supply and fixing LED inverter street light fitting 90 watt, PDC housing, IP 66, inbuilt Battery Back-up-auto on/off/dimming (preprammable) complete all as specified and directed. |
| 118 | M&L steel tubular swaged pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial tape rplug, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-31 (9.0 metre long) including of holes of reqd Nos and size for fixing of bracket, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete incuding all as specified and as directed.. Note:- Excavation and PCC works will be measured and paid separatly in respected items of this schedule. |
| 119 | Supply, laying & testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area 10 sqmm 4 core complete all as specified and directed. |
| 120 | Supply and laying unreinforced precast concrete cable cover, type- 1, size 250mmx150mmx40mm laid flat adjacent and abutting to each other across the length of cable laid dry complete all as specified & directed. |
| 121 | M&L for cement concrete 1:3 :6 type C-2 using 40 mm graded stone aggregate for foundation of poles / stays/strutus or basements etc complete all as specified and as directed. |
| 122 | M&L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping ( new and old damage coping) to poles / stays/strutus or basements etc complete all as specified and directed. |
| 123 | M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed. |
| 124 | S&F galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 125 | S&F street light timer panel including astronomincal digital DX3 Time Switches 1 output 16 A - 250 VA, 50/60 Hz Astronomical function, 56 Programmes ,1 Channel, High-precision clockwork accurate to seconds per day, contactor 3 phase 65 Amp, MCB TPN 63 Amp for incomer and , MCB TPN 63 Amp outgoing for overload and short circuit protection, 63 Amp, 415 Volt, Operating Temperature: - 20 degree C +55 degree C (ideal for outdoor environments), IP20 for distribution board mounting; requires an IP65 enclosure or weatherproof box for outdoor installation, 56 customizable programs (daily, weekly, or yearly scheduling), FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection , including all connected accessories and timer should be OEM and should conforms to IS/IEC 60947-4-1 complete all as specified & directed. |
| 126 | M & L bracket made out of GI tubing 40 to 54mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 40mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia with -4 Nos & flat washer (3 mm thick) 01 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and directed. |
| 127 | Supply & fix Junction box of size 255x200x105 mm with 32 Amps MCB SPN with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity and PVC 2.5 sqmm TC copper wire up to 7.5 mtr length for connection of security light from junction box to light fitting and includes making suitable hole on existing pole to take out connections to fitting if required at site complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender