| Sl. No. | Item Description |
| 1 | Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.20.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), |
| 2 | SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in _ all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS_ shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).). |
| 3 | 90 Watt |
| 4 | Supply & erection of Steel tubular pole with 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. Complete in all respect as per direction of E-I/c. |
| 5 | 410 SP-17, 8.5 mtr. (Approx. wt. 92kg.) |
| 6 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade cable in passed through G.I. / M.S. or Hume Pipe. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 7 | 16 sq. mm 4 core (i) (343.00-170.00 = 173.00) |
| 8 | 25 sq. mm 3.5 core (j) |
| 9 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 25 A TPN (E-ii) |
| 10 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 11 | 2x2.5sq.mm |
| 12 | Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint. |
| 13 | Supply and Fixing 40mm. dia 1.5mtr. Long G.I. pipe 'B' Class bracket with 2 Nos. 'D' clamps 50X6mm. flat iron on steel tubular pole / PCC pole with bolts, nuts etc. complete in all respect, as per direction of E-I/C. |
| 14 | Supply & fixing of 75 mm x 90 mm shackle insulator /100 mm x 65 mm pin insulator including G.I. Bolts /spindle nuts etc. complete in all respect. |
| 15 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. |
| 16 | 16 sq. mm (d) |
| 17 | 25 sq. mm (e) |
| 18 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of ngineer Incharge. |
| 19 | 16 sq. mm 4 core (i) |
| 20 | 25 sq. mm 3.5 core (j) |
| 21 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 22 | Supply & Fixing of MS rod for earthing with 2.5 m long, solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mts. below the GL complete with bolts & nuts & GI earth wire 7/14. Complete in all respect, as per direction of E-I/C. |
| 23 | Providing and fixing 25 mm X 5 mm Gl. strip on surface or in recess for connections etc. as required. |
| 24 | Supplying and laying of 160MM Dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc. in the existing trench, complete as required |
| 25 | Supply & Fixing of L.T. Junction box on pole suitable for out door type operation of size 450 x 300 x 200 mm made of 3.0 mm CRCA sheet complete in respect as per Annexure. |
| 26 | Supply & erection of end clamp (J-hook) |
| 27 | Supply & erection of screw tightener |
| 28 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respect as per direction of the Engineer-Incharge at SITE |
| 29 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. |
| 30 | Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect.(42116 Mtr. x 1 wire x 1.02 x 0.15 = 6443.75 KG) |
| 31 | Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. |
| 32 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.20.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as_ per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K /5700°K /6500°K (As per ANSI Bin) , |
| 33 | SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS’ shall be submitted. Shape size and CCT shall be as approved by _ Engineer-in-Charge as _ per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 34 | 200 watt |
| 35 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and _ providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 36 | Supply & Laying of 90 mm dia. DWC pipe for drawing of power cable across the road by drilling of 120 mm dia. At 1 Mtr. Below the road Level the work should be done by manual trenchless method. Complete in all respect as per direction of E-I/c. |
| 37 | Supply & erection of stay set at least 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 cm x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19 mm x 600 double screw tightener, 7/4.00 mm G.I stay wire etc. in 1:3:6 cement concrete complete in all respect. |
| 38 | S/F of G.I. pipe 100 mm dia 'B' class ZINDAL / TATA make including required material T&P etc. complete in all respect as per direction of the Engineer-Incharge at SITE |
| 39 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 40 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 41 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 42 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender