Power Government Departments Closing in 2 days TDR #58007090

Tender for Quotation Inviting Basic Rate of Base Plate, Foundation Bolt and Junction box for Framing Estimate.

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2026
2 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Quotation Inviting Basic Rate of Base Plate, Foundation Bolt and Junction box for Framing Estimate.

BOQ

Name of Work:- Quotation inviting Basic Rate of different item for framing Estimate.
Sl. No. Item Description
1Silicon mounted flexibal neon LED tube (RGBW) with vertical and Hostizontal bending options, IP68 connectors, controlar protecocol DMX. Tube should be IP67 and IK06 Protected of following wattage per meter
2Linear outline tube (RGBW) having IP66 ingress protection, IK06 impact protection, DMX Controllable with extruded aluminium housing suitalbe for continous line of light of following wattage per meter.
3Linear wall washer (RGBW) having IP65 ingress protection, IKO8 impact protection, BMX controllable with toughen glass extruded aluminium hosuig sutiabel for constant locking hinge with adjustable tilt angles of following wattage per meter :-
4Main Controller DMX-Main Controller: Industrial grade controller that can control the sub controllers of upto 6000 DMX universes. Wiring accessories includign leader and Jumper cables with male and female IP67 connectors and end-caps. Compatible with windows 10 32 bot or 64 bot version or equivalent. complies with standard DMX Control Protocol. The Controller shall have stable single transmission and can synchronize with NTP and GPS. It hsall have two RJ45 network interfaces (100/1000 madaptive)
5LED RGBW flood lighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. the beam angel of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of opeating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor> 0.09. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required of following watage.
6Supply of LED 3000K Sport Light LUMINARIE: Supply of LED 3000K Sport light luminarie for façade lighting with die cast aluminium housing, power coated finish. The beam angle of the fitting shall 10 Degree as per the requirement. Power factor-0.9. the fixture shall be suitable to operate at ambient temperture range of 10 to +50 degree centrigrade and shall be IP66 and IK08 rated. the life time of the luminaries should be 50,000 burning hours at 30 degree centrigrade. the lulminarie shall be confirmign to BIS (IS10322) and shall be complete with all necessary accesories rquired for proper working of the fixture including weather proof connection cables, water proof connector etc. the lgiht equipmenet shoul hav eadjustable base for angle adjustment so that light direction can be adjusted to illuminate suitable desired structure elements of following wttage.
7Aluminium Profile- For Façade Lighting Accessories luminium profile for Linear Flex 12x12mm
8Interconnection cable 1Mtr/ Starter cable- for Façade Lighting Accessoris
9Power supply- for façade lgithing AC100-200V imput, DC24V output, 200W, CV power supply IP Rating:IP67
10Main Controller for Façade Lighting 8ch stansalone Controller
114Ch Decodeer- for Façade lighting
124ch DMX Splitter- for façade lighting
13XLR Connector (M)- for Façade Lighting
14XLR Connector (F)- for Façade Lighting
15Supply of ceiling mounted 4.0Tr (12000K.cal/hrs) 3 Star rating 4 way cassette inverter type high efficiency compressor, air coold cu condenser, aluminium fins with ocean black fin coating R-32 refrigerant Cassette will be suitalbe for 220V-50Hz powe supply.
16Supply of 4.0Tr (12000K.Cal/hrs) for 3 star Floro standing Tower type air conditioners fitted with hermetically sealed compressor operating on Refrigerent R-32, Non CFC sutiable for wall mounting only. Suitalbe for opertion 220v 50 HZ single phase Ac supply capable of conforming (1) Cooling (2) Dehumidifying (3) Ari circulating (4) Filtering
17Power supply mother board of 30 KVA online UPS (Make-Numeric)
18Power Supply Card (KHPEPOSU432-PB432) of 80 KVA Online UPS(Make- Numeric)
19Interface card (KHPEINTPN) of 80 KVA Online UPS (Make- Numeric)
2012V 42 AH Sealed maintenance (SMF) Battery)
21Supply of 4 mtr height decorative lighting pole made of round tube confirming IS:1161 with cast iron/ aluminium embellishments with bracket give pre treatment and finish with polyurethane paint, having connection arrangement, MCB etc as reqwd as per design & dimension at Annexure-I Model-Priscilla/DOUBS/EDGAR/ equivalent, Make- Halonics/ Bajaj/Jaquar/equivalent
22Supply of single arm decorative bracket as per design/ dimension Annexure-I
23Supply of Double arm decorative bracket as per design/ dimension Annexure-I
2460 watt Decorative LED light: Operating Votage Range 140-270V/AC Rated voltage 220-240V/AC, 50 Hz, System wattage 60W ± 10% Driver efficiency > 85% Light source/ Type LED/ SMD, Efficacy ≥ 100m*w CRI> 80Ra, Housing Die Cast and spun Aluminium with PU coating finish graphite Grey/ Black Finish, optics Acrylic diffuser mounting pole/ suspended (Pole thread pipe mounted/ Inner Dia ᴓ41mm pipe Mounting) Size (DxH): ᴓ 620x 650 mm ( Tol±5 mm) ingress Protection (IP) IP65, Surge Protection 5.0KV inbuilt in Driver (Extra 10 KVA SPD inside the product) over voltage Protection cutoff @ 3300v/Ac ± 5% and withstand upto 440V/AC for 2 Hrs, Open, Short & Circuit Protectted. Model-BORAGE/ ANTIQUA/Sentinel/ equivalent. Make- Halonics/ Bajaj/Jaquar/equivalent
25Supply of CPCB approved make Retrofit Emission Control Device (RECD) confirming to JSPCB/ CPCB Standard/ norms/ Giddiness/ regulations and complying the emmissi reduction norms of NGT/ CPCB using filterlen approach for DG sets of following capacity :-
2640 KVA
2762.5 KVA
2882.5 KVA
29100 KVA
30125 KVA
31160 KVA
32200 KVA
33250 KVA
34500 KVA
35750 KVA
36Recess mounting LED panel light 2x2 (80W) SMD type, pressure dia cast aluminium housing with integrated heate sink having driver efficiency >85%, surge protection 2.5KV, over voltage protection, open/ short circuit protecton, operating votlage 140 to 270V AC 50Hz, P.F ≥ 10, CCT 3000°K/4000°/5700°/6500°K, CRI≥ 80 IP 20 protection, systme luminous efficacy ≥ 110 lumen/ watt confirming to IEC:62722 or IS:10322 Part-5/Section 2
37Power Transformer with on Load Tap Changer) of ISI marked
38Supplying outdoor type copper wound transformer continuously rated for 3Ph, 50Hz at full load and temp rise not exceeding 45° C by thermometer in oil and 50° C by the resistance in widnding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provide separate earhting. The Transformer shll have power terminal aggragement, bushing/ cable end box on HT side and cable end box on LT side 2 nos channels with stoppers shall be provided and fixed on the Provided plinth for mounting the transformer. The Transformer should have following standard fitting. transformer shall be latest manufacturing standards as per amended IS specification and the load & no load looses sahll be limited to the values give below or as per IS or norms issued by SEB which ever are lower :-
391) Oil conservator with filling hole with cap and plain oil level gauge.
402) Silica gel dehydrating breather charged with silica gel.
413) Oil drain valve
424) Oil filter valve
435) Lifting eyes/ hooks
446) Two earthign terminals
457) Diagram and rating plate
468) Air ven
479) Explosion vent
4810) 100 mm dia thermo meter with thermometer pocket
4911) Four bi Directinoal plain roller.
50Power Transformer 11000/433 vols with on Load Tap changer-12.5% to + 2.5% in steps of 2.5% as per BIS Level-2
51a) 500 KVA
52b) 750 KVA
53c) 1000 KVA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58007090
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-10-2026
Authority
Authority Name Electric Works Division
Work Description Tender for Quotation Inviting Basic Rate of Base Plate, Foundation Bolt and Junction box for Framing Estimate.
Basic Detail
Tender No Energy/EWD/Ranchi/41/26-27
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 13 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
Annex-1.PDF
BOQ_162161.xls
f05f642b-490b-46ec-b02c-57e6abfc8fde.html
TC.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
PDF

Annex-1.PDF

xls

BOQ_162161.xls

html

f05f642b-490b-46ec-b02c-57e6abfc8fde.html

pdf

TC.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender