Tender For Providing And Fixing Vitrified Tile Flooring, Puf Wall Panel, False Ceiling & Electrical Works To House Sensory Booth At Lab-25 Of Tfan Department And Renovation Work For Insect Culture Room At Fpic Dept, Csir-Cftri, Mysuru
Tender Overview
Project Description
Tender for Providing And Fixing Vitrified Tile Flooring, Puf Wall Panel, False Ceiling & Electrical Works To House Sensory Booth At Lab-25 Of Tfan Department And Renovation Work For Insect Culture Room At Fpic Dept, Csir-Cftri, Mysuru
BOQ
| Sl. No. | Item Description |
| 1 | Part A: Civil Works |
| 2 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | Laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 M sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 600 x 600 mm(Labour charges)(Vitrified floor tiles only supplied by the Department) |
| 5 | Laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 M sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm(Labour charges)(Vitrified floor tiles only supplied by the Department) |
| 6 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mmMake: Leticrete or Asian Paints or Fosroc |
| 7 | Providing and Fixing of Double skin self supporting Modular Poly Wall Panel including Wall/Pillar cladding made of 0.5MM thick Pre-Coated GI sheets on both sides with PUF Insulation as infill of density 38-kg/m3, including 82x20 mm Top, Bottom & Side Tracks, Fastners, Silicon Sealent and PVC Coving.50mm PanelMake :Pre-Coated GI sheet: AMNS/JSW/ Equivalent |
| 8 | Providing and fixing tiled False Ceiling of approved materials of size 600x600 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 170 gsm/sqm) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x32mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross \\"T\\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\"at 600mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications drawings and as directed by Engineer-in-Charge. 8 mm thick square edge PVC Laminated Gypsum Tile of size 600x600 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.The tiles should have Thermal Conductivity k = 0.24 w/m k, Colour white, Fire performance Class 0/Class1 (BS 476 Part 6&7) in module size of 600 x 600 x 8 mmMAKE: ARMGYP SAND (ARMSTRONG)/ Knauff- White sand/SAINT-GOBAIN-GYPREX DEW DROP |
| 9 | Providing and fixing Double Leaf Door (Clean Room Doors): Double leaf Door fit into the wall. Shutter sheet thickness will be 0.8mm and frame will be 1.2mm thick made up of GPSP GI sheet with epoxy polyester powder coating. Leaf thickness will be 44mm and infill will be PUF with density 40±2 Kg/m33. Door bottom seal shall be provided. Double Leaf Door Accessories: 06 No. SS Roll bearing Hinges, 01 No. Door Closer, 02 No. SS D Handle Back-to-back, 02 No. Double glazed view panel of 450*600 mm with 5 mm thick toughened glass, 02 No. Drop Seal, 01 No. Lock and 02 No. Kick plateDoor Size: 1550 x 2100 mm |
| 10 | Providing and fixing Single Leaf Door (Clean Room Doors): Single leaf Door fit into the wall. Shutter sheet thickness will be 0.8mm and frame will be 1.2mm thick made up of GPSP GI sheet with epoxy polyester powder coating. Leaf thickness will be 44mm and infill will be PUF with density 40±2 Kg/m33. Door bottom seal shall be provided. Single Leaf Door Accessories: 03 No. SS Roll bearing Hinges, 01 No. Door Closer, 01 No. SS D Handle Back-to-back, 01 No. Double glazed view panel of 450*600 mm with 5 mm thick toughened glass, 01 No. Drop Seal, 01 No. Lock and 01 No. Kick plateDoor Size: 1050 x 2100 mm |
| 11 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 M sand) |
| 12 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 M sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm |
| 13 | Providing and fixing factory made uPVC glazed/ wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles having minimum wall thickness of 1.70mm for series R1 & R2 profiles and 2.10 mm for series R3 and R4 profiles conforming to EN: 12608 in any shape colour and design duly reinforced with galvanized mild steel section made of required shape and size as per CPWD specification, uPVC extruded glazing beads, interlocks and inline sas adaptor (where ever required) of appropriage dimension, EPDM gasket, hardware SS 304 grade fasteners of Minimum 8mm dia with counter sunk head, comprixing of matching polyamide PA6 grade sleeve for fixing frame to finished wall as pr IS1367: PART 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duty sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specificaton and direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge.Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS:3548 & IS:16231 shall be paid separately.Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for:(i) Sites with basic wind speed >45 m/ sec as per IS875 - part3(ii) sits with structure height morethan 20m for all wind speedstwo track two panels sliding window with aluminium channel for roller track, wool pile, nylon rollers with SS304 body.Using R2 series with frame (40mm and above) x (40mm and above) and sash (25mm x above) x (50mm & above) with zinc alloy (Zamak) powder coated touch locks with hook (Height upto 1.2 metre)Make: LG / NCL VEKA/ Komarling |
| 14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)Make: JINDAL |
| 15 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)Make: JINDAL |
| 16 | Providing and fixing 9mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P brass/ stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.MAKE: NOVAPAN |
| 17 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 18 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:100x10 mm |
| 19 | Providing and fixing aluminium handle of of size 150 mm with SS screws etc. complete as per direction of Engineer-in-chargePolyester powder coated minimum thickness 50 micron aluminium |
| 20 | Providing and fixing SS wire guage (Grade - 304) fly proof mesh (or mosquito mesh) of thickness 0.5 mm dia to 0.63 mm dia of average width of aperture 1.4 mm or less (as decided by the engineer incharge) in UPVC/Wooden window shutters with necessary screws, fittings, teakwood beading etc., |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete, including scaffolding at all heights |
| 22 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content including scaffolding at all heightsWith water thinnable cement primer on wall surface having VOC content less than 50 grams/ litreMAKE: asian or its equivalent |
| 23 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic ompound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour including scaffolding at all heightsTwo coatsRecommended brand:Asian/Nerolac/Berger/Dulux |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture MAKE: asian - apcolite gloss enamel OR Nerolac – synthetic enamel OR Dulux - Gloss enamel |
| 25 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead for all lead upto 10 kms including all lifts involved. |
| 26 | Part B: Electrical Works |
| 27 | Group A wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 28 | Group B wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 29 | Wring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit (concealed) as required. 2 x 2.5 Sq.mm. + 1 x 2.5 Sq.mm. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 30 | Wiring for circuit / submain wiring alongwith earthwire with 2 x 6.0 + 1 x 6.0 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.Make: Please refer Special Electrical Conditions under Tender Document File. Note: All start, loop & end point of the wires are to be terminated with \\"Cu\\" Lugs of suitable type and size and individual pipes for wiring. |
| 31 | Supplying and drawing 2 x 1.5 sq. mm of FRLS / HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 32 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make: Please refer Special Electrical Conditions under Tender Document File.a) 3x1.5 Sq.mm. |
| 33 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make: Please refer Special Electrical Conditions under Tender Document File.b) 3x4.0 Sq.mm. |
| 34 | Supplying and fixing of 20 mm size medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 35 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep |
| 36 | Supplying and fixing of 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter-connections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). Make: Please refer Special Electrical Conditions under Tender Document File. |
| 37 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral Make : Please refer Special Electrical Conditions under Tender Document File. |
| 38 | Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 39 | Supplying, installation, Testing & Commissioning of 36 Watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make: Please refer Special Electrical Conditions under Tender Document File. |
| 40 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 36watt. |
| 41 | Supplying, Installation, Testing & Successful Supply, Installation, Testing and Successful Commissioning of 1.5 Tr Nominal Cooling Capacity (Tonnage); 5 Star Rating; 5 or above ISEER; Inverter Air Conditioner Technology; Cooling Capacity: Approximately 18,000 BTU/hour (5275 Watts); Compressor: Inverter or non-inverter, with rotary or BLDC (Brushless DC) options; Refrigerant: Commonly uses R32 refrigerant; Condenser and Evaporator: Typically made of copper; Power Supply: Single-phase, 230V, 50Hz AC; Voltage Tolerance: Typically ±10% of the rated voltage; Indoor Unit Noise Level: Ranges from 34dB to 51dB depending on fan speed; Outdoor Unit Noise Level: Typically around 54dB; Moisture Removal: About 1.2 to 1.44 Liters per hour; Airflow Volume (High / Medium / Low): Can vary, but examples include 760 / 644 / 611 / 493 CFM (Wet CFM); Other Features: Auto Restart, Sleep Mode, Energy Saver Mode, Wide Voltage Range, Copper Condenser: 100% copper condenser for efficient heat transfer, Stabilizer Free Operation and Anti-Fungal Filter and consisting of 1 each of Indoor Unit, Outdoor Unit, upto 20 Metre Copper Tube, Rated Inter Connecting FRLS Copper Wires inside steel reinforced hose pipe (upto 20 m), LCD Remote with Battery, rated Stablizer, MS Painted Stand for Outdoorunit & User Manual. Make: Please refer Special Electrical Conditions under Tender document File. |
| 42 | Supplying, Installation, Testing & Successful Commissioning of 8way GI Modular Box along with Modular Base, Cover Plate etc., in recess / wall using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 15/16 Amp DP Socket - 1 Nos; b) 20 Amps, 2 Pole, \\"C\\" Curve, 10kA, 230V Mini MCB - 2 No. Internal wiring for 15 Amps Switch, MCB with 6.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and 6.0 sq.mm FRLS Multistrand, Single Core Copper Wire, Green Colour for Earthing Loop and terminate all the wires using suitable size Copper Lugs etc., as required. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 43 | Supplying, Installation, Testing & Successful Commissioning of 16 GI Modular Box along with Modular Base, Cover Plate etc., in recess / wall using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 2 Nos; b) 3 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 20 Amps, 2 Pole, \\"C\\" Curve, 10kA, 230V Mini MCB - 1 No. Internal wiring for 5 Amps Switch & Socket with 2.5 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and Green Colour 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire for Earthing Loop and terminate all the wires using suitable size Copper Lugs etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 44 | Dismantling & taking down Old light Fittings / related wirings, hardwares etc., after carefully disconnecting the incoming electrical input and insulating the same, depositing all the old materials in an organised manner to the Auction / Electrical Section Store Yard or as per the advise of the Electrical Officer In-Charge of the Project without any damage. For every Toilet it is the responsibility of the contractor to disconnect the incoming supply, insulate the same while caring Civil works. After the complition with new electrical equipment reconnecting, however engineer in charge will advise for the source of power supply Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender