Tender for Providing, Installation And Commissioning Of High Wall Split/ Window/Cassette/Floor Mounted Split Type Air Conditioning System As And When Urgently Required In Different Name Of Work :- Construction Of Nels (National Emergency Life Support) Skill Centre At Second Floor Of Blood Bank At Agmc & Gbp Hospital Complex, Agartala, Tripura / Sh; Building Portion Including Internal Water Supply And Sanitary Installation (In Second Col). (Balance Work) Amount (1.5 Cr). B) Construction Of Central S Le Collection Centre Renovation Work For Central Lab At Agmc & Gbp Hospital / Sh Building Portion Including Water Supply Sanitary Works Etc (1.5 Cr) C) Construction Of Double Storeyed Toiler Block Opposite To Gynae Ward At Agmc & Gb Hospital Complex, Agartala (50 Lakhs) / Providing, Installation And Commissioning Of High Wall And Floor Mounted Vertical Split Type Air Conditioning System In The Nels (National Emergency Life Support) Skill Centre At Second Floor Of Blood Bank At Agmc & Gbp Hospital Complex, Agartala, Tripura
BOQ
| Sl. No. | Item Description |
| 1 | Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. |
| 2 | 1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt). |
| 3 | 2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt). |
| 4 | Providing 3 star rated (Minimum 3 star with applicabls ISEER accordlng to current industry standard) Ceiling mounted Cassette/ Floor mounted vertical Split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption ) capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. |
| 5 | 3.65 TR floor mounted vertical Split type AC machine (Minimum rated cooling capacity should not be lsss than 10950 Kcl/hr ) or 43800 BThu/h or 12775 watt). |
| 6 | Standard installation, testing and commissioning of1.5 / 2.0 TR high wall split type / window AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. |
| 7 | Standard installation, testing and commissioning of 3.65 TR floor mounted vertical Split type AC machine including hole cutting, finishing etc. as per direction of the Engineer-in-charge. |
| 8 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. |
| 9 | Fabrication of M.S platform of appropriate size, base plate, nuts and bolts/ universal bracket (GSS) for both IDU and ODU of 3.65 TR floor mounted vertical Split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. |
| 10 | Supply, installation of additional length of copper pipe of appropriate size of (5/8\\" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.5 / 2.0 TR high wall type and 3.65 TR floor mounting vertical Split type ACs. |
| 11 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender