Tender For Construction Of 6000Mt Cold Storage At Salash Skus Ltd., Dist.:-Dakshin Dinajpur Under Ridf Xxxi.
Tender Value
10.97 Crore
Estimated cost
Bid Submission
02 Nov 2026
16 days left
EMD
21.94 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 6000Mt Cold Storage At Salash Skus Ltd., Dist.:-Dakshin Dinajpur Under Ridf Xxxi.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Oct-2026 | Corrigendum | Other | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Cold Storage 6000 Mt. (1 No.)Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation |
| 4 | Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-incharge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) Depth upto 1.5 m. |
| 5 | Treatment to the back filling of RCC foundation with chemicalemulsion by admixing imidacloprid emulsifiable conecret (160ml in 75 litres) with water at the rate of 7.5 ltr. Per sq.m of the vertical surface of the substructure of each side of the foundation. The worrk shall be carried out as per specification as described in para 7.3.1 of code IS-6313 (part-II) 2013 (Mode of measurement will be per sq.m of vertical area of foundation treated) |
| 6 | Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing Imidaclopride emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq.m of the surface before sand bed or sub grade is laid. Hole upto 50mm. to 75mm. deep at 150mm. centre to centre both ways shall be made with 12mm diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313 (part-II) 2013. (Mode of measurment will be plan area of plinth treated.) |
| 7 | Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating same by through saturation with water ramming complete, including the cost of supply of sand |
| 8 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.) |
| 9 | 25mm thk Damp Proof Course with cement concrete (1:1.5:3) (with graded stone aggregate 10mm normal size) & painting the top suface with a coat of bitumen [ VG 40] using 1.7kg. Per Sqm. Including heating the bitumen & cost & carriage of all materials complete. [ Bitumen to be supplied by the Agency]. Foundation, basement all floor, Roof & above |
| 10 | Supplying & laying Polythene sheet (150gm/sqm.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. All floor, Roof & above |
| 11 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 12 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur VarietyGround |
| 13 | 1st Floor |
| 14 | 2nd Floor |
| 15 | 3rd Floor |
| 16 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur VarietyGround |
| 17 | 1st Floor |
| 18 | 2nd Floor |
| 19 | 3rd Floor |
| 20 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. 25 mm to 30 mm shuttering without staging in foundation |
| 21 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete workGround Floor |
| 22 | 1st Floor |
| 23 | 2nd Floor |
| 24 | 3rd Floor |
| 25 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For work in foundation, basement all floor, Roof & above. Tor steel Fe 500 (SAIL/TATA/RINL). Ground Floor |
| 26 | 1st Floor |
| 27 | 2nd Floor |
| 28 | 3rd Floor |
| 29 | Brick work with 1st class bricks in cement mortar(1:4). In foundation and plinth |
| 30 | Brick work with 1st class bricks in cement mortar(1:4). In superstructureGround Floor |
| 31 | 1st Floor |
| 32 | 2nd Floor |
| 33 | 3rd Floor |
| 34 | 125mm thk. Brick work with 1st class bricks in cement mortar (1:4) in ground floor. Foundation, basement all floor, Roof & aboveGround Floor |
| 35 | 1st Floor |
| 36 | 2nd Floor |
| 37 | 3rd Floor |
| 38 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 20 mm thick plaster. Foundation, basement all floor, Roof & above.Ground Floor |
| 39 | 1st Floor |
| 40 | 2nd Floor |
| 41 | 3rd Floor |
| 42 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 15 mm thick plaster. all floor, Roof & above.Ground Floor |
| 43 | 1st Floor |
| 44 | 2nd Floor |
| 45 | 3rd Floor |
| 46 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. . With 1:4 cement mortar. 10 mm thick plaster. all floor, Roof & above.Ground Floor |
| 47 | 1st Floor |
| 48 | 2nd Floor |
| 49 | 3rd Floor |
| 50 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 51 | Supplying fitting & fixing with integrated grills conforming to IS 1038-1975 & manufactured from rolled or Square steel sections conforming to IS 7452-1974 with non-fricition projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straightening if required, fixing lugs in cement concerete (1:2:4) with stone chips 20mm down cutting holes & mending good damages to match with excluding glazing . M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continously welded with M.S. flats & bars. any floors. Roof & above. Ground |
| 52 | Supplying, fitting & fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass. any floors, roof & above. |
| 53 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Fixed type ventilators as per I.S. sizes with horizontal glazing bars height being limited to 580 mm.Ground |
| 54 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]Ground |
| 55 | Supplying, fitting & fixing two pointed nose aluminium handle including fitting & fixing. any floors. Roof & above. |
| 56 | Supplying, fitting & fixing Aluminium peg stay 300mm long including fitting fixings |
| 57 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). sal: local. any floors. Roof & above.Ground |
| 58 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 59 | Supplying, Fitting & Fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work / concrete work as per direction. 40mmx6mm,200mm length. Any floors. Roof & above. |
| 60 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.:100mm. X 75mm. X 3.50 mm. Roof & above. |
| 61 | Anodised aluminium aldrop / sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted & fixed complete. 250mm x 16mm dia bolt. Any floors. Roof & above. |
| 62 | Neat Cement punning about 1.5mm thick in wall dado, window sills floor, drain Note: cement 0.152cum. Per 100 sqm in any floors. Roof & above. |
| 63 | Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 64 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two coat Water based interior grade Acrylic Primer |
| 65 | White washing including cleaning and smoothening surface thoroughly 1 (c)Three coats (on new works only). |
| 66 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat |
| 67 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coats. a) Normal Acrylic EmulsionGround Floor |
| 68 | 1st Floor |
| 69 | 2nd Floor |
| 70 | 3rd Floor |
| 71 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc |
| 72 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface: With super gloss (hi-gloss). Two coat (white in shad). any floors. Roof & above. |
| 73 | Office BuildingEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 74 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. Including watering and ramming etc. layer by layer complete. (payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 75 | Filling in foundation or plinth by fine sand (Grading Zone III as per IS: 383-1970) stacked at site.) in layers not exceeding 150mm as directed & consoling the same by through saturation with water ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity) |
| 76 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 77 | Treatment to the back filling of RCC foundation with chemicalemulsion by admixing imidacloprid emulsifiable conecret (160ml in 75 litres) with water at the rate of 7.5 ltr. Per sq.m of the vertical surface of the substructure of each side of the foundation. The worrk shall be carried out as per specification as described in para 7.3.1 of code IS-6313 (part-II) 2013 (Mode of measurement will be per sq.m of vertical area of foundation treated) |
| 78 | Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing Imidaclopride emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq.m of the surface before sand bed or sub grade is laid. Hole upto 50mm. to 75mm. deep at 150mm. centre to centre both ways shall be made with 12mm diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313 (part-II) 2013. (Mode of measurment will be plan area of plinth treated.) |
| 79 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thk. Approved quality ply board shuttering in any concrete work. Ground floor |
| 80 | Supplying & laying Polythene sheet (150gm/sqm.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. All floor, Roof & above |
| 81 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For work in foundation, basement all floor, Roof & above. Tor steel Fe 500 (SAIL/TATA/RINL). |
| 82 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 83 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 84 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 85 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.). Foundation, basement all floor, Roof & above |
| 86 | Brick work with 1st class bricks in cement mortar(1:4). In foundation and plinth |
| 87 | 25mm thk Damp Proof Course with cement concrete (1:1.5:3) (with graded stone aggregate 10mm normal size) & painting the top suface with a coat of bitumen [VG 40] using 1.7kg. Per Sqm. Including heating the bitumen & cost & carriage of all materials complete. [ Bitumen to be supplied by the Agency]. Foundation, basement all floor, Roof & above |
| 88 | Brick work with 1st class bricks in cement mortar(1:4) . In Superstructure , |
| 89 | 125mm thk. Brick work with 1st class bricks in cement mortar (1:4) in ground floor. Foundation, basement all floor, Roof & above |
| 90 | 75 mm thick brick work with 1st class Bricks set in cement, sand mortar(1:4) in ground floor including H.B. netting in very alternate layers. Foundation, basement all floor, Roof & above. |
| 91 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 20 mm thick plaster. Foundation, basement all floor, Roof & above. |
| 92 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 15 mm thick plaster. all floor, Roof & above. |
| 93 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. . With 1:4 cement mortar. 10 mm thick plaster. all floor, Roof & above. |
| 94 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 95 | Toilet Floor: Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622- 2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N. all floor, Roof & above. |
| 96 | Supplying , fitting & fixing 1st quality Ceramic tiles in walls to match with the existing work & 4 nos. of key stones (10 mm. fixed with araldite at back of each tiles & finishing the joints with the white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface ,if necessary or by synthetic adhesive & grout materials etc. (Anti skid) with sand cement mortar (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sqm. & joint filling using white cement slurry @0.20kg./Sqm. Area of each tile above 0.09sqm. colour decorative. all floor, Roof & above. |
| 97 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sandcement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(A) Deep Colour & White |
| 98 | Neat Cement punning about 1.5mm thick in wall dado, window sills floor, drain Note: cement 0.152cum. Per 100sqm |
| 99 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). sal: Local any floors. Roof & above. |
| 100 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 101 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door shutters as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. any floors. Roof & above. 32mm thick |
| 102 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door frame as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. 66mmx90mm. Any floors. Roof & above. |
| 103 | Supplying, Fitting & Fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work / concrete work as per direction. 40mmx6mm,200mm length. Any floors. Roof & above. |
| 104 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 75mm. X 3.50mm. |
| 105 | Supplying, fitting & fixing Brass floor door stopper. Any floors. Roof & above. |
| 106 | Anodised aluminium grip handle with base plate of approved quality fitted & fixed completed.With base plate. 225mm grip x 16mm dia rod x 38mm plate x 3.2mm thick Any floors. Roof & above. |
| 107 | Anodised aluminium aldrop/sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted & fixed complete. 250mm x 16mm dia bolt. Any floors. Roof & above. |
| 108 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: . 100mm long x10mm dia bolt. Any floors. Roof & above. |
| 109 | Anodised aluminium decorative handle (hexagonal/ftuled) of approved quality fitted and fixed complete. 175mm plate x 12mm dia rod x 60mm hexagonal/ fluted. All floor & roof |
| 110 | Supplying 6 levers 'Godrej' Crystal Satine Mortice Lock with keys including fitting & fixing complete. Any floors. Roof & above. |
| 111 | Godrej Hydraulic door closer fitted and fixed complete. Heavy type. Any floors. Roof & above. |
| 112 | Providing, fitting and fixing in position glazed casement/ 2 track or sliding windows and casement or fixed type windows, skylights ventilators with 6mm thick float/smoke glass in natural mat finish anodised colur (10-12 micron) aluminium section of series 40 mitre and jointed crimped with stainless steel friction stay, handles, locks, glazing clips, EPDM gasket, weather pile in frame grooves, nickel chrome plated fixing screws all of approved make including all materials and labour asper drawings, specifications complete. Any floors. Roof & above. |
| 113 | Supplying fitting & fixing with integrated grills conforming to IS 1038-1975 & manufactured from rolled or Square steel sections conforming to IS 7452-1974 with non-fricition projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straightening if required, fixing lugs in cement concerete (1:2:4) with stone chips 20mm down cutting holes & mending good damages to match with excluding glazing . M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continously welded with M.S. flats & bars. any floors. Roof & above. |
| 114 | Supplying fitting & fixing Collapsible gate with 40mm x 40mm x 6mm tee as top & bottom guide rail, 20mm x 10mm x 2mm vertical channels 100 mm apart in fully stretched position 20mmx5mm M.S. flats as collapsible bracings properly rivetted & washered including 38mm steel rollers including locking arrangements fitted & fixed in position with lugs set in cement concrete & including cutting necessary holes chasing etc. in walls floors etc & making good damages complete etc. any floors. Roof & above. In ground floor. |
| 115 | Supplying fitting & fixing M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 16 Kg./sq.mtr and above. any floors. Roof & above. |
| 116 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.. any floors. Roof & above. |
| 117 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. any floors. Roof & above. |
| 118 | Supplying and applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat. any floors. Roof & above. |
| 119 | Supplying, and, applying Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 120 | Supplying, and, applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Solvent based interior grade Acrylic Primer. any floors. Roof & above.One Coat |
| 121 | Supplying,applying rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 122 | Supplying & Applying acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two Coats.i) Standard Quality. The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 123 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: on timber or plastered surface. With super gloss (hi gloss). Two coats (with any shade except white). any floors. Roof & above. |
| 124 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface: With super gloss (hi-gloss). Two coat (white in shade). any floors. Roof & above. |
| 125 | Supplying, fitting & fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass. any floors, roof & above. |
| 126 | Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface or as per direction of Engineer in Charge. |
| 127 | Security QuarterEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 128 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. Including watering and ramming etc. layer by layer complete. (payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 129 | Filling in foundation or plinth by fine sand (Grading Zone III as per IS:383-1970) stacked at site.) in layers not exceeding 150mm as directed & consoling the same by through saturation with water ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity) |
| 130 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 131 | Treatment to the back filling of RCC foundation with chemicalemulsion by admixing imidacloprid emulsifiable conecret (160ml in 75 litres) with water at the rate of 7.5 ltr. Per sq.m of the vertical surface of the substructure of each side of the foundation. The worrk shall be carried out as per specification as described in para 7.3.1 of code IS-6313 (part-II) 2013 (Mode of measurement will be per sq.m of vertical area of foundation treated) |
| 132 | Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing Imidaclopride emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq.m of the surface before sand bed or sub grade is laid. Hole upto 50mm. to 75mm. deep at 150mm. centre to centre both ways shall be made with 12mm diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313 (part-II) 2013. (Mode of measurment will be plan area of plinth treated.) |
| 133 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thk. Approved quality ply board shuttering in any concrete work. Ground floor |
| 134 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. Ground floor |
| 135 | Supplying & laying Polythene sheet (150gm/sqm.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. All floor, Roof & above |
| 136 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For work in foundation, basement all floor, Roof & above. Tor steel Fe 500 (SAIL/TATA/RINL). |
| 137 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 138 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 139 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 140 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.). Foundation, basement all floor, Roof & above |
| 141 | Brick work with 1st class bricks in cement mortar(1:4). In foundation and plinth |
| 142 | 25mm thk Damp Proof Course with cement concrete (1:1.5:3) (with graded stone aggregate 10mm normal size) & painting the top suface with a coat of bitumen [VG 40] using 1.7kg. Per Sqm. Including heating the bitumen & cost & carriage of all materials complete. [ Bitumen to be supplied by the Agency]. Foundation, basement all floor, Roof & above |
| 143 | Brick work with 1st class bricks in cement mortar(1:4). In Superstructure |
| 144 | 125mm thk. Brick work with 1st class bricks in cement mortar (1:4) in ground floor. Foundation, basement all floor, Roof & above |
| 145 | 75 mm thick brick work with 1st class Bricks set in cement, sand mortar(1:4) in ground floor including H.B. netting in very alternate layers. Foundation, basement all floor, Roof & above. |
| 146 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 20 mm thick plaster. Foundation, basement all floor, Roof & above. |
| 147 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 15 mm thick plaster. all floor, Roof & above. |
| 148 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. . With 1:4 cement mortar. 10 mm thick plaster. all floor, Roof & above. |
| 149 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 150 | Toilet Floor: Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622- 2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N. all floor, Roof & above. |
| 151 | Supplying , fitting & fixing 1st quality Ceramic tiles in walls to match with the existing work & 4 nos. of key stones (10 mm. fixed with araldite at back of each tiles & finishing the joints with the white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface ,if necessary or by synthetic adhesive & grout materials etc. (Anti skid) with sand cement mortar (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sqm. & joint filling using white cement slurry @0.20kg./Sqm. Area of each tile above 0.09sqm. colour decorative. all floor, Roof & above. |
| 152 | Neat Cement punning about 1.5mm thick in wall dado, window sills floor, drain Note: cement 0.152cum. Per 100sqm |
| 153 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). sal: Local. any floors. Roof & above. |
| 154 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 155 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door shutters as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. any floors. Roof & above. 32mm thick |
| 156 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door frame as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. 66mmx90mm. Any floors. Roof & above. |
| 157 | Supplying, Fitting & Fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work / concrete work as per direction. 40mmx6mm,200mm length. Any floors. Roof & above. |
| 158 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 75mm. X 3.50mm. |
| 159 | Supplying, fitting & fixing Brass floor door stopper. Any floors. Roof & above. |
| 160 | Anodised aluminium grip handle with base plate of approved quality fitted & fixed completed.With base plate. 225mm grip x 16mm dia rod x 38mm plate x 3.2mm thick Any floors. Roof & above. |
| 161 | Anodised aluminium aldrop/sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted & fixed complete. 250mm x 16mm dia bolt. Any floors. Roof & above. |
| 162 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: . 100mm long x10mm dia bolt. Any floors. Roof & above. |
| 163 | Anodised aluminium decorative handle (hexagonal/ftuled) of approved quality fitted and fixed complete. 175mm plate x 12mm dia rod x 60mm hexagonal/ fluted. All floor & roof |
| 164 | Supplying 6 levers 'Godrej' Crystal Satine Mortice Lock with keys including fitting & fixing complete. Any floors. Roof & above. |
| 165 | Godrej Hydraulic door closer fitted and fixed complete. Heavy type. Any floors. Roof & above. |
| 166 | Providing, fitting and fixing in position glazed casement/ 2 track or sliding windows and casement or fixed type windows, skylights ventilators with 6mm thick float/smoke glass in natural mat finish anodised colur (10-12 micron) aluminium section of series 40 mitre and jointed crimped with stainless steel friction stay, handles, locks, glazing clips, EPDM gasket, weather pile in frame grooves, nickel chrome plated fixing screws all of approved make including all materials and labour asper drawings, specifications complete. Any floors. Roof & above. |
| 167 | Supplying fitting & fixing with integrated grills conforming to IS 1038-1975 & manufactured from rolled or Square steel sections conforming to IS 7452-1974 with non-fricition projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straightening if required, fixing lugs in cement concerete (1:2:4) with stone chips 20mm down cutting holes & mending good damages to match with excluding glazing . M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continously welded with M.S. flats & bars. any floors. Roof & above. |
| 168 | Supplying fitting & fixing Collapsible gate with 40mm x 40mm x 6mm tee as top & bottom guide rail, 20mm x 10mm x 2mm vertical channels 100 mm apart in fully stretched position 20mmx5mm M.S. flats as collapsible bracings properly rivetted & washered including 38mm steel rollers including locking arrangements fitted & fixed in position with lugs set in cement concrete & including cutting necessary holes chasing etc. in walls floors etc & making good damages complete etc. any floors. Roof & above. In ground floor. |
| 169 | Supplying fitting & fixing M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 16 Kg./sq.mtr and above. any floors. Roof & above. |
| 170 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.. any floors. Roof & above. |
| 171 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. any floors. Roof & above. |
| 172 | Supplying and applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat. any floors. Roof & above. |
| 173 | Supplying and applying Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 174 | Supplying, and, applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Solvent based interior grade Acrylic Primer. any floors. Roof & above.One Coat |
| 175 | Supplying & Applying acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two Coats.i) Standard Quality. The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 176 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: on timber or plastered surface. With super gloss (hi gloss). Two coats (with any shade except white). any floors. Roof & above. |
| 177 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface: With super gloss (hi-gloss). Two coat (white in shade). any floors. Roof & above. |
| 178 | Supplying, fitting & fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass. any floors, roof & above. |
| 179 | Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface or as per direction of Engineer in Charge. |
| 180 | Common Toilet BlockEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 181 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. Including watering and ramming etc. layer by layer complete. (payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 182 | Filling in foundation or plinth by fine sand (Grading Zone III as per IS: 383-1970) stacked at site.) in layers not exceeding 150mm as directed & consoling the same by through saturation with water ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity) |
| 183 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 184 | Treatment to the back filling of RCC foundation with chemicalemulsion by admixing imidacloprid emulsifiable conecret (160ml in 75 litres) with water at the rate of 7.5 ltr. Per sq.m of the vertical surface of the substructure of each side of the foundation. The worrk shall be carried out as per specification as described in para 7.3.1 of code IS-6313 (part-II) 2013 (Mode of measurement will be per sq.m of vertical area of foundation treated) |
| 185 | Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing Imidaclopride emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq.m of the surface before sand bed or sub grade is laid. Hole upto 50mm. to 75mm. deep at 150mm. centre to centre both ways shall be made with 12mm diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3 of code IS-6313 (part-II) 2013. (Mode of measurment will be plan area of plinth treated.) |
| 186 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thk. Approved quality ply board shuttering in any concrete work. Ground floor |
| 187 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. Ground floor |
| 188 | Supplying & laying Polythene sheet (150gm/sqm.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. All floor, Roof & above |
| 189 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For work in foundation, basement all floor, Roof & above. Tor steel Fe 500 (SAIL/TATA/RINL). |
| 190 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 191 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 192 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 193 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.). Foundation, basement all floor, Roof & above |
| 194 | Brick work with 1st class bricks in cement mortar(1:4). In foundation and plinth |
| 195 | 25mm thk Damp Proof Course with cement concrete (1:1.5:3) (with graded stone aggregate 10mm normal size) & painting the top suface with a coat of bitumen [VG 40] using 1.7kg. Per Sqm. Including heating the bitumen & cost & carriage of all materials complete. [ Bitumen to be supplied by the Agency]. Foundation, basement all floor, Roof & above |
| 196 | Brick work with 1st class bricks in cement mortar(1:4) . In Superstructure , floor, Roof & above. |
| 197 | 125mm thk. Brick work with 1st class bricks in cement mortar (1:4) Roof & above |
| 198 | 75 mm thick brick work with 1st class Bricks set in cement, sand mortar(1:4) in ground floor including H.B. netting in very alternate layers. Foundation, basement all floor, Roof & above. |
| 199 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 20 mm thick plaster. Foundation, basement all floor, Roof & above. |
| 200 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 15 mm thick plaster. all floor, Roof & above. |
| 201 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, noisng and dripourse, chiping, scaffolding / staging where necessary. . With 1:4 cement mortar. 10 mm thick plaster. all floor, Roof & above. |
| 202 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 203 | Toilet Floor: Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622- 2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N. all floor, Roof & above. |
| 204 | Supplying , fitting & fixing 1st quality Ceramic tiles in walls to match with the existing work & 4 nos. of key stones (10 mm. fixed with araldite at back of each tiles & finishing the joints with the white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface ,if necessary or by synthetic adhesive & grout materials etc. (Anti skid) with sand cement mortar (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sqm. & joint filling using white cement slurry @0.20kg./Sqm. Area of each tile above 0.09sqm. colour decorative. all floor, Roof & above. |
| 205 | Neat Cement punning about 1.5mm thick in wall dado, window sills floor, drain Note: cement 0.152cum. Per 100sqm |
| 206 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). sal: malayasian. any floors. Roof & above. |
| 207 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 208 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door shutters as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. any floors. Roof & above. 32mm thick |
| 209 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door frame as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. 66mmx90mm. Any floors. Roof & above. |
| 210 | Supplying, Fitting & Fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work / concrete work as per direction. 40mmx6mm,200mm length. Any floors. Roof & above. |
| 211 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 75mm. X 3.50mm. |
| 212 | Supplying, fitting & fixing Brass floor door stopper. Any floors. Roof & above. |
| 213 | Anodised aluminium grip handle with base plate of approved quality fitted & fixed completed.With base plate. 225mm grip x 16mm dia rod x 38mm plate x 3.2mm thick Any floors. Roof & above. |
| 214 | Anodised aluminium aldrop/sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted & fixed complete. 250mm x 16mm dia bolt. Any floors. Roof & above. |
| 215 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: . 100mm long x10mm dia bolt. Any floors. Roof & above. |
| 216 | Anodised aluminium decorative handle (hexagonal/ftuled) of approved quality fitted and fixed complete. 175mm plate x 12mm dia rod x 60mm hexagonal/ fluted. All floor & roof |
| 217 | Supplying 6 levers 'Godrej' Crystal Satine Mortice Lock with keys including fitting & fixing complete. Any floors. Roof & above. |
| 218 | Godrej Hydraulic door closer fitted and fixed complete. Heavy type. Any floors. Roof & above. |
| 219 | Providing, fitting and fixing in position glazed casement/ 2 track or sliding windows and casement or fixed type windows, skylights ventilators with 6mm thick float/smoke glass in natural mat finish anodised colur (10-12 micron) aluminium section of series 40 mitre and jointed crimped with stainless steel friction stay, handles, locks, glazing clips, EPDM gasket, weather pile in frame grooves, nickel chrome plated fixing screws all of approved make including all materials and labour asper drawings, specifications complete. Any floors. Roof & above. |
| 220 | Supplying fitting & fixing with integrated grills conforming to IS 1038-1975 & manufactured from rolled or Square steel sections conforming to IS 7452-1974 with non-fricition projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straightening if required, fixing lugs in cement concerete (1:2:4) with stone chips 20mm down cutting holes & mending good damages to match with excluding glazing . M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continously welded with M.S. flats & bars. any floors. Roof & above. |
| 221 | Supplying fitting & fixing Collapsible gate with 40mm x 40mm x 6mm tee as top & bottom guide rail, 20mm x 10mm x 2mm vertical channels 100 mm apart in fully stretched position 20mmx5mm M.S. flats as collapsible bracings properly rivetted & washered including 38mm steel rollers including locking arrangements fitted & fixed in position with lugs set in cement concrete & including cutting necessary holes chasing etc. in walls floors etc & making good damages complete etc. any floors. Roof & above. In ground floor. |
| 222 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.. any floors. Roof & above. |
| 223 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. any floors. Roof & above. |
| 224 | Supplying and applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat. any floors. Roof & above. |
| 225 | Supplying, and, applying Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 226 | Supplying, and, applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Solvent based interior grade Acrylic Primer. any floors. Roof & above.One Coat |
| 227 | Supplying,applying rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 228 | Supplying & Applying acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two Coats.i) Standard Quality. The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 229 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: on timber or plastered surface. With super gloss (hi gloss). Two coats (with any shade except white). any floors. Roof & above. |
| 230 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface: With super gloss (hi-gloss). Two coat (white in shade). any floors. Roof & above. |
| 231 | Supplying, fitting & fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass. any floors, roof & above. |
| 232 | Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface or as per direction of Engineer in Charge. |
| 233 | Underground Water Reservoir with Pump Room Earth work in excavation of foundation in all sorts of soil in dry and wet condition including necessary protection for earth retention of the sides of the excavated area, removal as required, complete as per specification and direction of Architect/Employer. Depth up to 1.5 m. |
| 234 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.(Payment to be made on basis of measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 235 | Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge)Depth upto 1.5 m. |
| 236 | Treatment to the back filling of RCC foundation with chemicalemulsion by admixing imidacloprid emulsifiable conecret (160ml in 75 litres) with water at the rate of 7.5 ltr. Per sq.m of the vertical surface of the substructure of each side of the foundation. The worrk shall be carried out as per specification as described in para 7.3.1 of code IS-6313 (part-II) 2013 (Mode of measurement will be per sq.m of vertical area of foundation treated) |
| 237 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs , beams, columns , lintels curved or straight including fitting , fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 238 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(i) Tor steel / Mild steel. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m |
| 239 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 240 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concreteas per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 241 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.). Foundation, basement all floor, Roof & above |
| 242 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]. With 1:6 cement mortar. 25 mm thick plaster |
| 243 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. |
| 244 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and dripourse, chiping, scaffolding / staging where necessary. With 1:6 cement mortar. 20 mm thick plaster. Foundation, basement all floor, Roof & above. |
| 245 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (ground floor) With 1:6 cement mortar. 15 mm thick plaster |
| 246 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (ground floor). With 1:4 cement mortar. 10 mm thick plaster |
| 247 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 248 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). sal: malayasian. any floors. Roof & above. |
| 249 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 250 | Supplying, Fitting & Fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work / concrete work as per direction. 40mmx6mm,200mm length. Any floors. Roof & above. |
| 251 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark. 100mm. X 75mm. X 3.50mm |
| 252 | Anodised aluminium aldrop/sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted & fixed complete. 250mm x 16mm dia bolt. Any floors. Roof & above. |
| 253 | Providing, fitting and fixing in position glazed casement/ 2 track or sliding windows and casement or fixed type windows, skylights ventilators with 6mm thick float/smoke glass in natural mat finish anodised colur (10-12 micron) aluminium section of series 40 mitre and jointed crimped with stainless steel friction stay, handles, locks, glazing clips, EPDM gasket, weather pile in frame grooves, nickel chrome plated fixing screws all of approved make including all materials and labour asper drawings, specifications complete. Any floors. Roof & above. |
| 254 | Supplying fitting & fixing with integrated grills conforming to IS 1038-1975 & manufactured from rolled or Square steel sections conforming to IS 7452-1974 with non-fricition projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc. including hoisting in position, straightening if required, fixing lugs in cement concerete (1:2:4) with stone chips 20mm down cutting holes & mending good damages to match with excluding glazing . M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continously welded with M.S. flats & bars. any floors. Roof & above. |
| 255 | Supplying fitting & fixing Collapsible gate with 40mm x 40mm x 6mm tee as top & bottom guide rail, 20mm x 10mm x 2mm vertical channels 100 mm apart in fully stretched position 20mmx5mm M.S. flats as collapsible bracings properly rivetted & washered including 38mm steel rollers including locking arrangements fitted & fixed in position with lugs set in cement concrete & including cutting necessary holes chasing etc. in walls floors etc & making good damages complete etc. any floors. Roof & above. In ground floor. |
| 256 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. For structural members of specified sections weighing less than 22.5 Kg./m |
| 257 | Locking arrangement, rails bottom rollers for Jail type doors including supplying fitting and fixing in position complete as per approved design. |
| 258 | Supplying, fitting, fixing bolts with nuts, washer: 10 to 16 mm dia: Length up to 75 mm |
| 259 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 260 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.. any floors. Roof & above. |
| 261 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. any floors. Roof & above. |
| 262 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: on timber or plastered surface. With super gloss (hi gloss). Two coats (with any shade except white). any floors. Roof & above. |
| 263 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface: With super gloss (hi-gloss). Two coat (white in shade). any floors. Roof & above. |
| 264 | Supplying, and, applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Solvent based interior grade Acrylic Primer. any floors. Roof & above.One Coat |
| 265 | Supplying & Applying acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two Coats.i) Standard Quality. The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 266 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two coats. |
| 267 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 268 | Supplying bubble free float glass of approved make and brand conforming to IS : 2835-1987. 4mm thick coloured / tinted / smoke glass. |
| 269 | Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc. Note : Cement 0.152 cum per 100 sqm |
| 270 | Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required) |
| 271 | Supplying, fitting & fixing Puddle coller of G.I. pipe (G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece, Double Flanage etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. Medium quality) of different diameters (Length=200mm+RCC Wall thickness+250mm), both and fully socket threaded and welded with 6mm thick M.S. plate, fitted & fixed in R.C.C. work, with all labour & materials. 200mm dia welded with 6mm thick 450mm x 450mm M.S. plate (outlet) |
| 272 | Supplying, fitting & fixing Puddle coller of G.I. pipe (G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece, Double Flanage etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. Medium quality) of different diameters (Length=200mm+RCC Wall thickness+250mm), both and fully socket threaded and welded with 6mm thick M.S. plate, fitted & fixed in R.C.C. work, with all labour & materials. 150mm dia welded with 6mm thick 400mm x 400mm M.S. plate (outlet) |
| 273 | Supplying, fitting & fixing Puddle coller of G.I. pipe (G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece, Double Flanage etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. Medium quality) of different diameters 200mm+RCC Wall thickness+250mm, both and fully socket threaded and welded with 6mm thick M.S. plate, fitted & fixed in R.C.C. work, with all labour & materials. 100mm dia welded with 6mm thick 325mm x325mm M.S. plate (inlet) |
| 274 | Electrical Substation BuildingEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 275 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
| 276 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. Including watering and ramming etc. layer by layer complete. (payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 277 | Filling in foundation or plinth by fine sand in layers not exceeding 150mm as directed & consoling the same by through saturation with water ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity) |
| 278 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 279 | Pre-Constructional Anti-termite measures: Antitermite treatment to bottom surface (in case of Masonry foundation and basements) and the sides (Upto a height of 300mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrefos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 liters per sq.m. area. The work shall be carried out as per specification described in 6.2.1 of code IS-6313 (Part-II) 1981. (Mode of Measurement will be the plan area of foundation treated.) |
| 280 | Antitermite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrefos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 liter per sq.m. of the surface before sand bed or subgrade is laid. Holes upto 50mm.to 75mm. deep at 150mm. centre to centre both ways shall be made with 12mm. diameter mild steel rod on the surface to facilitated saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in Para 6.4 of code IS-6313 (Part-II)-1981. (Mode of measurement will be per sq.m. of plan area of plinth treated). |
| 281 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thk. Approved quality ply board shuttering in any concrete work. |
| 282 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge |
| 283 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m. Tor steel/Mild Steel (SAIL/TATA/RINL). |
| 284 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 285 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 286 | Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling (thickness 75mm) |
| 287 | Brick work with 1st class bricks in cement mortar(1:4). In foundation and plinth |
| 288 | 25mm thk Damp Proof with cement concrete (1:1.5:3) (with graded stone aggregate 10mm normal size) & painting the top suface with a coat of bitumen [ VG 40] using 1.7kg. Per Sqm. Including heating the bitumen & cost & carriage of all materials complete. [ Bitumen to be supplied by the Agency]. |
| 289 | Brick work with 1st class bricks in cement mortar(1:6) .In superstructure, ground floor |
| 290 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface] With 1:6 cement mortar. 20 mm thick plaster. |
| 291 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface]. With 1:6 cement mortar. 15 mm thick plaster. |
| 292 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding /staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] . With 1:4 cement mortar. 10 mm thick plaster. |
| 293 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 294 | Neat Cement punning about 1.5mm thick in wall dado, window sills floor, drain Note: cement 0.152cum. Per 100 sqm |
| 295 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white. For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. |
| 296 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. |
| 297 | Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. (Measurement will be made on the area of opening covered by the rolling shutter corrected upto 2 decimal.) |
| 298 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 299 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 300 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: Two Coat. |
| 301 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 302 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat. Solvent based interior grade Acrylic Primer. |
| 303 | Supplying & Applying acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two Coats.i) Standard Quality. The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 304 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: on timber or plastered surface. With super gloss (hi gloss). Two coats (with any shade except white). any floors. Roof & above. |
| 305 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface: With super gloss (hi-gloss). Two coat (white in shade). any floors. Roof & above. |
| 306 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass. |
| 307 | Boundary wallEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500 mm |
| 308 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation |
| 309 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.) |
| 310 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 311 | Hire and labour charges for shuttering with centreing and necessary staging. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thick approved quality plyboard shuttering in any concrete work. |
| 312 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. Tor steel. For works in foundation, basement and upto roof of ground floor / upto 4 m |
| 313 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 314 | Brick work with 1st class bricks in cement mortar(1:6). In foundation and plinth |
| 315 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 316 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging chipping where necessary. With 1:6 cement mortar 20 mm thick plaster |
| 317 | Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface or as per direction of Engineer in Charge. |
| 318 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. For structural members of specified sections weighing less than 22.5 Kg./m |
| 319 | Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.) |
| 320 | Supplying 7 ply galvanised strand wire 19 gauge fitted and fixed complete with necessary eyes, hooks and straining bolts (excluding the cost of straining bolts.) |
| 321 | Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete. i) 10 mm. dia.(a) 150 mm. |
| 322 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC. Two coats |
| 323 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 324 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 325 | Supplying & Applying painting with best quality synthetic enamal paint of approved make & brand including smoothening surface by papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface. With super gloss (hi gloss). Two coats (with any shade except white). any floors. Roof & above. |
| 326 | Main Gate & Guard RoomEarth work in excavation of foundation trenches or drains, in all sorts of soils (including mixed soil but excluding laterite or sandstone) i.c. removing, spreaqding or stacking the spoilts within a lead of 75 m 'as directed. The item includes necessary trimming the sides of trenches. Levelling, dressing and ramming the bottom, bailing out water etc. as required complete.. Depth of excavation not exceeding 1500 mm. |
| 327 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
| 328 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation |
| 329 | Filling in foundation or plinth by fine sand (Grading Zone III as per IS:383-1970) stacked at site.) in layers not exceeding 150mm as directed & consoling the same by through saturation with water ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity) |
| 330 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 331 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade(i) Pakur Variety |
| 332 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m. Tor steel/Mild Steel (SAIL/TATA/RINL). |
| 333 | Hire and labour charges for shuttering with centreing and necessary staging. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thick approved quality plyboard shuttering in any concrete work. |
| 334 | Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m) |
| 335 | Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth |
| 336 | Brick work with 1st class bricks in cement mortar (1:6). In superstructure. |
| 337 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 338 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar ic. rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, ic.throating, nosing and drip course where necessary. With 1:6 cement mortar. 20 mm thck plaster in ground floor |
| 339 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary. With 1:6 cement mortar. 15 mm thick plaster |
| 340 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary. With 1:4 cement mortar. 10 mm thick plaster |
| 341 | Making Groove line ( 12 mm wide,12 mm deep) in plastered surface. |
| 342 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. For other Structural works like galleries etc. |
| 343 | Locking arrangement, rails bottom rollers for Jail type doors including supplying fitting and fixing in position complete as per approved design. |
| 344 | Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. 20 mm dia bolt. 450 mm long |
| 345 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 346 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). sal: local. any floors. Roof & above. |
| 347 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 348 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door shutters as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. any floors. Roof & above. 32mm thick |
| 349 | Supplying fitting & fixing fiber reinforcement polymer(FRP) composite door frame as per approved design with glass fiber reinforcement plastic moulded skins & a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science & Technology(DST) to satisfy IS:4020 door testing performance criteria. 66mmx90mm. Any floors. Roof & above. |
| 350 | Supplying, Fitting & Fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work / concrete work as per direction. 40mmx6mm,200mm length. Any floors. Roof & above. |
| 351 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :100x63x3.2 mm. Any floors. Roof & above. |
| 352 | Supplying, fitting & fixing Brass floor door stopper. Any floors. Roof & above. |
| 353 | Anodised aluminium grip handle with base plate of approved quality fitted & fixed completed.With base plate. 225mm grip x 16mm dia rod x 38mm plate x 3.2mm thick Any floors. Roof & above. |
| 354 | Anodised aluminium aldrop/sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted & fixed complete. 250mm x 16mm dia bolt. Any floors. Roof & above. |
| 355 | Providing, fitting and fixing in position glazed casement/ 2 track or sliding windows and casement or fixed type windows, skylights ventilators with 6mm thick float/smoke glass in natural mat finish anodised colur (10-12 micron) aluminium section of series 40 mitre and jointed crimped with stainless steel friction stay, handles, locks, glazing clips, EPDM gasket, weather pile in frame grooves, nickel chrome plated fixing screws all of approved make including all materials and labour asper drawings, specifications complete. Any floors. Roof & above. |
| 356 | Supplying, fitting & fixing bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4 mm thick coloured / tinted / smoke glass. any floors, roof & above. |
| 357 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 358 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 359 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 360 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 361 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 362 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC. Two coats |
| 363 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 364 | Supplying, and, applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Solvent based interior grade Acrylic Primer. any floors. Roof & above.One Coat |
| 365 | Supplying & Applying acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two Coats.i) Standard Quality. The rate includes cost of material, labour, scaffolding and all incidental charges. any floors. Roof & above. |
| 366 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) & marble dust in proportion (1:2) including smooth finishing & rounding off corners including raking out joints or roughening of concrete surface & application of cement slurry before flooring works using cement @1.75kg/sqm all complete including all materials & labour. In ground floor. 3mm thick topping(High polishing grinding on this item is not permitted with ordinary cement). Using grey cement. 35mm thk. all floor, Roof & above. |
| 367 | Toilet Floor: Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622- 2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N. all floor, Roof & above. |
| 368 | Supplying , fitting & fixing 1st quality Ceramic tiles in walls to match with the existing work & 4 nos. of key stones (10 mm. fixed with araldite at back of each tiles & finishing the joints with the white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface ,if necessary or by synthetic adhesive & grout materials etc. (Anti skid) with sand cement mortar (1:3) 15mm thick & 2mm thick cement slurry at back side of tiles using cement @ 2.91 kg/Sqm. & joint filling using white cement slurry @0.20kg./Sqm. Area of each tile above 0.09sqm. colour decorative. all floor, Roof & above. |
| 369 | Storm Water DrainEarthwork in excavation in drains and other structures in all sorts of soil or loose material including removing surplus spoils and debris to a maximum lead of 100m including bailing outing manually or by pumps as per specification and drawing and as directed by the Engineer.(Trench shall be kept dry by dewatering and removal of slush.) Depth of excavation not exceeding 1.5m below G.L |
| 370 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation |
| 371 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.). Foundation, basement all floor, Roof & above |
| 372 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 373 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thk. Approved quality ply board shuttering in any concrete work. |
| 374 | Constructing catch pit to a depth of 1.0m (Inside) with 250mm th. 1st class Brick Work (1:4) in all sides over a layer of jhama brick soling & 100mm th. jhama cement concrete (1:4:8) including necessary earth work, providing approved type C.I. Syphone (150mm dia) with topping RCPC gully grid (5MT load bearing capacity) constructing invert with brick-on-edge, including 20mm th. inside cement plaster (1:4) finished with neat cement punning, at the top 100mm th. R.C.C. slab (1:1.5:3) with stone chips including necessary reinforcement, shuttering as per standard drawing and as directed by E-I-C complete in all respect and removal of surplus earth with all costs of labour and materials. Inside measurement of catch pit, 600mm × 525mm |
| 375 | Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non-pressure underground Drainage, Sewerage & Cross drainage application.150mm internal dia. |
| 376 | 300mm internal dia. |
| 377 | 400mm internal dia. |
| 378 | 500mm internal dia. |
| 379 | Land Development Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layercomplete. (Payment to be made on the basis ofmeasurement of finished quantity of work)(a) With earth obtained from excavation of foundation |
| 380 | Earthwork in filling, in compound, tank, lowland, ditches, etc. with good earth in layers not exceeding 150 mm including breaking clods and consolidating the same by ramming and dressing completely. With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth. |
| 381 | Concrete Internal RoadSupplying, spreading and compacting Sand to required thickness, in layers not exceeding 150 mm to proper gradient and camber, inundating each layer by water and packing and ramming layer by layer to achieve desired compaction, including lighting, guarding, barricading and making adequate earthen bundh where necessary, curing with water as per direction, mending cracks and depressions by ramming. wherever necessary. Supply of materials as per approved specification Medium Sand (Grading Zone II as per IS:383-1970) stacked at site. |
| 382 | Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).Grading -V : |
| 383 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading-II Aggregate (53 mm to 22 mm) Using Stone Screening Type B (11.2 mm). Manual Means |
| 384 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. 100mm thick interlocking designer concrete paver block M- 50 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 25-35 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative. |
| 385 | Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-inCharge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete. |
| 386 | Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. Two Coats |
| 387 | Sanitary & Plumbing Works Supplying, fitting and fixing shower of approved brand and make. Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand). |
| 388 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 25 mm |
| 389 | 20 mm |
| 390 | 32 mm |
| 391 | 40 mm |
| 392 | 50 mm |
| 393 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).15 mm dia |
| 394 | 20 mm dia |
| 395 | 25 mm dia |
| 396 | 32 mm dia |
| 397 | 40 mm dia |
| 398 | 50 mm dia |
| 399 | Supplying, fitting and fixing bib cock or stop cock.Supplying, fitting & fixing CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand |
| 400 | Chromium plated Bib Cock with wall flange (Equivalent to Code No.5047 & Model - Florentine of Jaquar or similar brand). |
| 401 | Supplying, fitting and fixing pillar cock of approved make CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand). |
| 402 | Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 403 | Supplying, fitting & fixing Chromium plated double coat Hook(Equivalent to Code No. 35761 &Model - KUBIX of Jaquar or similar). |
| 404 | Supplying, fitting and fixing shower of approved brand and make. Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 405 | Supplying, fitting and fixing liquid soap container. Cromium plated. |
| 406 | Supplying, fitting & fixing Supplying, fitting and fixing porcelain soap tray of approved make. Recessed soap tray of size 150 mm X 150 mm |
| 407 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 408 | Supplying, fitting and fixing towel rail with two brackets Aluminium. 25 mm dia. & 750 mm long |
| 409 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin or oval type (Counter top with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size |
| 410 | Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 411 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.For Exposed Work CPVC Pipes Class-I,SDR-1120 mm |
| 412 | 25 mm |
| 413 | 32 mm |
| 414 | 40 mm |
| 415 | 50 mm |
| 416 | For Concealed Work CPVC Pipes Class-I,SDR-1115mm |
| 417 | Supplying, fitting & fixing PVC pipes for underground work of approved make of (medium duty) conforming to ASTMD - 1785 & threaded to match with GI Pipes as per IS : 1239 (Part - I). With all necessary accessories, specials viz. socket, bend, tee, union, coss, elbo, nipple, lomgscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making thread, cutting trenches upto 1.5 metre below suffacein all sorts of soil & refilling the same directed complete in all respect. (Payment will be made on the centre line measurments of the total pipe line including all specials. No separate payment will be made for assesories, specials) PVC Pipes (Dia) 40 mm |
| 418 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. Sink with drain board 1050 mm X 450 mm X 180 mm |
| 419 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Single Socketed 3 Meter Length. 75 mm |
| 420 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Single Socketed 3 Meter Length. 110 mm |
| 421 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Door Tee 75 mm. |
| 422 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Door Tee 110 mm. |
| 423 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Plain Y 75mm |
| 424 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Plain Y 110 mm |
| 425 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Double Y 75mm |
| 426 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Double Y 110 mm |
| 427 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Bend 450 75mm. |
| 428 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Bend 450 110mm. |
| 429 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Bend 87.50 75mm. |
| 430 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Bend 87.50 110mm. |
| 431 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Vent Cowl 75 mm |
| 432 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Vent Cowl 110mm |
| 433 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Pipe Clip 75 mm |
| 434 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Pipe Clip 110mm |
| 435 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 470 mm X 280 mm X 340 mm |
| 436 | Supplying,fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 750 mm long |
| 437 | Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect. |
| 438 | Supplying, fitting and fixing urinal flush pipe fittings of approved brand. C.P. urinal flush pipe fittings range of one |
| 439 | Supplying, fitting and fixing 15 mm C.P. over brass spreader. |
| 440 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap. 580 mm X 440 mm |
| 441 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'P' trap |
| 442 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E.W.C. Plastic (hallow type) black. |
| 443 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 444 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. C. P. Flush Pipe |
| 445 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.600 mm lomg |
| 446 | 750 mm long |
| 447 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer.1000 litre capacity capacity |
| 448 | Labour for hoisting plastic water storage tank.Upto 1500 litre capacity. Upto 1st story from GL. |
| 449 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 450 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Pakur variety. (SAIL/TATA/RINL) |
| 451 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover (heavy type) of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C (1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. For 50 users. With Pakur variety |
| 452 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. |
| 453 | Condenser TankEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 454 | a) Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. |
| 455 | (a) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) (B) Do - by fine sand. |
| 456 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.) |
| 457 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 458 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety (a) ground floor |
| 459 | (a) 1st floor |
| 460 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and directionI. SAIL/TATA/RINL (a) ground floor |
| 461 | (a) 1st floor |
| 462 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work(a) ground floor |
| 463 | (a) 1st floor |
| 464 | Neat Cement punning about 1.5mm thick in wall dado, window sills floor, drain Note: cement 0.152cum. Per 100sqm in any floors. Roof & above. |
| 465 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 466 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints , including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) (Excluding cost of chipping over concrete surface) Extra for each additional floor over the rate for ground floor items(ii) With 1:4 cement mortar (a) 20 mm thick plaster (a) ground floor |
| 467 | (b) 1st floor |
| 468 | BorewellInstallation of 1 No 250 mm x 150 mm dia Tubewell along with providing, testing and commissioning of Submersible pumpsetLabour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system including hire charges and labour for supplying of suitable dia. Casting pipes upto full depth of tube well with necessary sockets, tools and plants, staging, force pumping set and making necessary arrangements for boring and also cost of withdrawing the casing pipes and lowering pipes, stainers, blind pipes etc. complete. (The casing pipe should have a minimum 50 mm gap in between the outside of the tube well pipe and the casing pipe).b) For depth upto 250 meter for 150 dia. Tube well with top enlargement of 250 mm dia. i) First 50 metre |
| 469 | ii) Next 50 metre |
| 470 | iii) Rest 50 metre |
| 471 | iv) For additional depth beyond 150 m |
| 472 | Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge. 150 mm dia. 6.0 mm wall thickness |
| 473 | Supplying, fitting & fixing heavy type bell mouth PVC reducing socket. 200 mm X 250 mm |
| 474 | Supplying, fitting and fixing G.I. cap at top. 300 mm |
| 475 | Supply and delivery of UPVC pipe (CD) conforming to IS 12818:2010. (CIPET Certified)150 mm dia |
| 476 | 250 mm dia. |
| 477 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yeild in gallons per hour with \\"V\\" notch including hire and labour charges for all tools and plants and scaffolding as required complete in all respect. |
| 478 | Labour for making arrangement for showing vertically test including the cost for hire charges of tools and plants, scaffolding labour etc. all complete. |
| 479 | Collecting sample of water for physical bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc, complete in all respect as per direction and as per IS 10500 parameters. |
| 480 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having sizefrom 2 mm to 5 mm or the size aproved by the Engineer - in- charge including cost of materials labour and equipment complete. |
| 481 | Packing the annular space between the outside of the housing pipe & the bore with puddled clay balls of approved size as per direction of the Engineer - in- charge with cost of materials & labour complete. |
| 482 | Providing & fixing bottom plug as required for 150 mm dia PVC pipe including cost of materials & labour with fixing in position complete for sealing the bottom of assembly. |
| 483 | Supply and delivery of M.S. Housing clamp 250 mm dia. |
| 484 | Supply and delivery of M.S .Centre guide (Special Type) |
| 485 | Geophysical investigation of the aquifer by electro logging system with all tools & plants as necessary including supply of necessary report. |
| 486 | Electro-logging charge. |
| 487 | DG ShedEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.a) Depth of Excavation not exceeding 1500 mm. |
| 488 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 489 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) |
| 490 | Brick soling with picked jhama bricks including preparetion of bed as necessary with joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling(thickness 75mm.) |
| 491 | Cement concrete with graded stone ballast (40 mm. size excluding shuttering) In ground floor 1:3:6 proprtion. With N.B. Variety stone metal |
| 492 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety (a) ground floor |
| 493 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 494 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and directionI. SAIL/TATA/RINL(a) ground floor |
| 495 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or partthereof.a) Span up to 12 Mtr |
| 496 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand |
| 497 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :b) On steel or other metal surface :With super gloss (hi-gloss) -(i) Two coat (with any shade except white) |
| 498 | Supplying, fitting & fixing 1.5mm thick Trapezoidal profile corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x 55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer-in-charge including materials, labour, taxes and all other incidental charges (Payment to be made on area of finished work).In Roof |
| 499 | Add 18% G.S.T. + 1% L.W.Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 15, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 02, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender