Tender For Master Sewerage Scheme Faridabad- Tertiary Treatment With Disc Filters On Existing Stps Of 45, 80 And 100 Mld Along With Additional Provisions Of Blowers, Claridigester , Neutralisation Tank , Flash Mixer, Clariflocculator , Etc. And O And
Tender Overview
Project Description
Tender for Master Sewerage Scheme Faridabad- Tertiary Treatment With Disc Filters On Existing Stps Of 45, 80 And 100 Mld Along With Additional Provisions Of Blowers, Claridigester , Neutralisation Tank , Flash Mixer, Clariflocculator , Etc. And O And M/ Dlp Of 11 Years.
BOQ
| Sl. No. | Item Description |
| 1 | Bullet camera Prama Make PTNC123D3=6 Nos,NVR Prama 8ch 4k Network video Recorder PT-NR1A08-Q1=1Nos.,Hard disk drive 4TB SATA=1Nos., POE switch,* 8GE POE plus 2 GE Uplink 250mm POE switch=1Nos,Cat-6 Cable ,25mm PVC conduit with RJ 45 Connectors and lying of conduit and cat-6, accessories(Gitti,Screw,saddle,bend,cable,tie etc)Configuration charges and one year support camera fixing and configuration plus |
| 2 | Supply Installation Testing and Commissioning of incoming magnetic Flow meter 1000 mm Complete in all respect to the satisfaction of Engineer-in-charge. |
| 3 | Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.Submersible Copper Cable 3 Core 35 sqmm |
| 4 | Ultrasonic Level Transmitter as per standardspecifications. makes Endress,Hauser(EandH) |
| 5 | Ultrasonic level transmeter for level measurement, level control for dry run protection and SCADA as per standard specifications. makes Endress,Hauser(EandH) |
| 6 | SITC of incoming/outgoing Electromagnetic Flow meter 800 mm as per Standard Specification, Endress and Hauser make. complete in all respect as per Engineer In-Charge. |
| 7 | SITC of incoming/outgoing Electromagnetic Flow meter 700 mm as per Standard Specification, Endress and Hauser make. complete in all respect as per Engineer In-Charge. |
| 8 | Providing and fixing jointing testing commissioning aligning of 400mm Dia MS pipe with 10mm thick food grade epoxy paints complete in all respect and satisfactory of engineer-in-charge. |
| 9 | Supplying, jointing with collar welded joint, aligning, fixing of 600 mm Dia ERW MS Pipe with food grade epoxy paint coating on both side complete as per direction of Engineer- in -charge |
| 10 | Supply, laying, fixing, jointing and testing of 900 mm dia, 10 mm thick ERW MS pipe conforming to IS 3589, with internal and external surface preparation and application of two coats of epoxy paint/coating conforming to relevant IS specifications, including all necessary welding, fittings, jointing materials, handling, alignment, labour, tools and plants, complete in all respects as per site requirements and as directed by the Engineer-in-Charge. |
| 11 | Providing and fixing of 400 mm dia D.I D/F (PN 1.6) manually gear operated sluice valve (IVC, VAG, Kirloskar make) generally conforming to IS:14846, having body, door, dome, gland in graded ductile iron to IS:1865 Gr. 400/15, four faces and spindle nut of LTB to IS 318 Gr. LTB 2, inside screw non-rising stainless steel AISI-410 spindle, valves suitable for a maximum working pressure of 16 kg/cm² (seat test) and body tested to 24 kg/cm². Flanges drilled to IS 1538 Table 4 and 6 including, carriage, loading and unloading complete in all respect as per satisfaction of the Engineer-in-Charge. |
| 12 | Providing and Inserting of 1000mm i/d M.S. carrier pipe 12 mm thick (Fe-330 grade) Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 and testing complete in all respect. |
| 13 | Providing and Inserting of 800mm i/d M.S. Carrier pipe 12 mm thick(Fe-330 grade) Fabricated as per IS 3589 of 1991 from steel plates confirming to IS:-2062 including cutting, beveling, grinding and jointing with radiographically welding of pipe as per IS- 1182 , external and internal epoxy coating and testing complete in all respect |
| 14 | Construction of building for use of Pump house , Panel room , Operator room, office room and any other purpose required at Sewage treatment plant i/c Providing and fixing Exhaust Fan, Ceiling fan, Tile flooring , Dado, Plinth protection, Window, Door (with wire mash) Electric fitting and plumbing fitting etc. complete in all respect and satisfactory of Engineer-in-Charge |
| 15 | Design, Supply, installation, testing and commissioning of floor-mounted, indoor type, front-operated, compartmentalized Main LT Panel suitable for operation of 06-08 No. 11000LPM pumps of 28-30KW each with 415V, 3 Phase, 4 Wire, 50Hz AC system, fabricated from CRCA sheet steel with powder-coated finish, IP54 protection, complete with Aluminium busbars, ACB as Grid Incomer, digital multifunction energy meters with CTs, indicating lamps, selector switches, surge protection device (SPD), control wiring, terminal blocks, earth and neutral busbars, and outgoing feeders comprising MCCBs for CCTV Panel, Audio/Video Panel, Street Lighting Panel, External Illumination Panel, Irrigation Panel and Cafeteria Panel, including all internal interconnections, labeling, earthing provisions, accessories, testing, commissioning and handing over complete as per IEC/ IS standards and approved drawings. |
| 16 | Design, Supply, installation, testing and commissioning of floor-mounted, indoor type, front-operated, compartmentalized Main LT Panel suitable for operation of pumps of 100HP load with 415V, 3 Phase, 4 Wire, 50Hz AC system, fabricated from CRCA sheet steel with powder-coated finish, IP54 protection, complete with Aluminum busbars, 250A MCCB as Grid Incomer, digital multifunction energy meters with CTs, indicating lamps, selector switches, with 10 Nos 32A Outgoing and 6 Nos 16A outgoing control wiring, terminal blocks, earth and neutral busbars, and outgoing feeders comprising MCCBs for CCTV Panel, Audio/Video Panel, Street Lighting Panel, External Illumination Panel, Irrigation Panel and Cafeteria Panel, including all internal interconnections, labeling, earthing provisions, accessories, testing, commissioning and handing over complete as per IEC/ IS standards and approved drawings. |
| 17 | Providing and fixing Local Distribution Board,TPN,IP54 complete with MCBs, RCCB and accessories complete in all respects. |
| 18 | Design, Supply, Installation, Testing and Commissioning of Clari digester mechanism for 50MLD capacity claridigester with:-1.Design, supply and installation of Draft mixture tube of required no suitable to mount over closed RCC vessel capable for pumping sludge from bottom of vessel about 8 Min depth having flame proof motor of minimum 5HP capacity suitable speed reducer, SS/FRP draft tube minimum 3M diameter flared skirt for even sludge distribution arrangement, supporting stand etc along with SS 304 impeller, SS304 deflector, SS 304 suspender assembly, suitable bearing, electric cable and panel etc.2.Design, supply and installation of Double membrane gas dome for storage of gas of having dimension 15 M dia and 3M height having biogas capacity about 150Cum biogas . The outer membrane Dom/balloon should be UV proof where as the inner membrane should be resistive to H2S gas, Methane gas,CO2 gas under high moisture and temperature condition with suitable capacity of blower with required accessories etc. (For 50MLD capacity of approved make) |
| 19 | Design, Supply, manufacturing, Installation, Testing and Commissioning of Biogas scrubber to remove H2S gas from biogas with capacity 2000PPM to 200PPM in SS-304 suitable to handle biogas volume upto 300cum/ h including required accessories like Supply pipe of SS304, safety valve, Electric panel and cable etc.(For50MLD capacity of approved make |
| 20 | Design, Supply, manufacturing, Installation, Testing and Commissioning of Biogas Flaring system suitable for 100MLD capacity STP in SS304,suitable to handle biogas volume up to 300Cum/h with suitable foundation and required accessories like Electric panel and cable etc. |
| 21 | Design, Supply, Testing and Commissioning of OPEN CHANNEL GATE (SS-304) Electrically actuated Size - 1000 mm (W) X 1000 mm with Actuator complete in all respects |
| 22 | Design, Supply, Testing and Commissioning of OPEN CHANNEL GATE (SS-304) Electrically actuated Size - 1200 mm (W) X 1200 mm with Actuator complete in all respects |
| 23 | Design, Supply, Testing and Commissioning of OPEN CHANNEL GATE (SS-304) Electrically actuated Size - 1500 mm (W) X 1500 mm with Actuator complete in all respects |
| 24 | Supply Erection Testing and commissioning of 11KV Indoor VCB 800A, Panel Alu. bus bar with CT,PT, IDMT relay, Auxiliary relay (OTI,WTI, Buchzel) and others relay Extensible type With Power Pack Incoming/Outgoing VCB Panel (BOM details Attached) Make :- Schneider, ABB, CGL |
| 25 | Design, supply, Installation, testing and commissioning of Fiber disc filter for 90MLD discharge with required number of automatic back wash pump, necessary cabling, Electric panel, SS pipe fitting of required size etc. and other tools and tackles required complete in all respects for successful commissioning |
| 26 | Design, supply, Installation, testing and commissioning of Fiber disc filter for 70MLD discharge with required number of automatic back wash pump ,necessary cabling, Electric panel, SS pipe fitting of required size etc. and other tool sand tackles required complete in all respects for successful commissioning |
| 27 | Design, supply, Installation, testing and commissioning of Fiber disc filter for 45MLD discharge with required number of automatic backwash pump, necessary cabling, Electric panel, SS pipe fitting of required size etc .and other tools and tackles required complete in all respects for successful commissioning,etc. |
| 28 | Providing and fixing cast iron double flanged swing check type reflux (non return) valves of 1000mm diameter PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge |
| 29 | Providing and fixing cast iron double flanged swing check type reflux (non return) valves of 800mm diameter PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge |
| 30 | Design, Supply, manufacturing, Installation, Testing and Commissioning of Flash mixture mechanism in SS-316 suitable for 45 MLD capacity flash mixture tank with all required tools tackles for successful commissioning. |
| 31 | Design, Supply, manufacturing, Installation, Testing and Commissioning of Clariflocculator Mechanism in MSEP suitable for the 45 MLD Capacity clariflocculator tank with all required tools tackles for successful commissioning. |
| 32 | PLC Control Panel with CPU, I/O modules, HMI (minimum 10`), Ethernet switch, powersupply, UPS, communication modules, terminal blocks, complete programming, SCADAinterface and commissioning. Note: Special HMI parallel display with 55` wall mountedTV |
| 33 | Design, Supply, manufacturing, Installation, Testing and Commissioning of Clariflocculator Mechanism in MSEP suitable for the 50 MLD Capacity clariflocculator tank with all required tools tackles for successful commissioning. |
| 34 | Supply Installation Testing and Commissioning of SS 304 Junction Box of size 300x300mm with PMU complete in all respects |
| 35 | Supply Installation Testing and Commissioning of SS 304 Junction Box of size 600mmx600mm with local control arrangements complete in all respects |
| 36 | Operation and Maintenance Cum DLP of 3 TTP which includesDeployment of Plant-In-Charge, Operators, Electricians, Helpers, Chemists,Consumables, Civil Work, Electrical/Mechanical Work Maintenance withReplacement, Repairment, etc. for 11 Years |
| 37 | Setting Up of Laboratory (pH, BOD, COD, TDS,TSS, etc.) with all the Equipments required for Tertiary Treatment Plant according to CPHEEO manual excluding Civil Structure |
| 38 | Providing and fixing testing commissioning of Air Foil Bearing Energy Efficient High Speed Turbo Blower Model NX350-C060 along with Permanent Magnet Synchronous Motor and Variable Frequency Drive 10900 m³/hr @ 0.66 kgf /cm2(G) Standard Turbo Blower Equipment 1. i)Blower Core with Permanent Magnet Synchronous Motor, 2. ii)High-performance Variable Speed Drive/Inverter 3. Local Control Panel for Control and Monitoring 4. Remote Control capability via Ethernet, LAN or Hard wiring 5. Temperature Sensors for Motor, Bearing, Suction and Discharge air flow. 6. Pressure Sensors for Discharge Conditions Pressure Sensor and Alert for Air Filter Condition. 7. Built in Flow Calculation 8. Built in Speed Measurement 9. Internal vibration and dynamic effect Absorption Mounts 10. Built in Air Filter. 11. All the component above is included in a Sound Enclosure 12. Blow off Valve with silencer. 13. Discharge Cone 14. Wafer type Dual Plate Check Valve 15. Metallic Expansion Bellow 16. Wafer type Butterfly Valve complete in all respect. • The Blower is one body type for the Indoor installation with after cooler arrangement. |
| 39 | HSR Items- Master Sewerage Scheme Faridabad- Tertiary treatment with Disc Filters on existing STPs of 45, 80 and 100 MLD along with additional provisions of Blowers, Claridigester , Neutralisation tank , Flash Mixer, Clariflocculator , etc. and O and M/ DLP of 11 Years Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender