Tender For Renovation Of Assembly Hall Of Institute Of Integrated And Honors Studies At Kuk
Tender Value
1.65 Crore
Estimated cost
Bid Submission
02 Nov 2026
15 days left
EMD
3.31 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kurukshetra → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Assembly Hall Of Institute Of Integrated And Honors Studies At Kuk
BOQ
| Sl. No. | Item Description |
| 1 | `Checking of Measurements of all works at site with respect to Detailed Estimate / Technically Sanctioned Estimate, DNIT and checking of all data viz bill, measurements etc. uploaded on HEWP by contractor and executing all other related activities including supervision of work, as per direction of Engineer-In-Charge complete in all respects. Note- Atleast Minimum Wages as per Latest HKRNL Wage Rates to be paid for Category-II District, Level-III Jobs. |
| 2 | Excavating, supplying and filling of Tibba Sand having CBR 8% (including royalty) by mechanical transport upto any lead and Lift also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Wooden Acoustical Slats Wall Paneling (with one mm laminate).Providing and fixing Tongue and Groove Wooden Acoustical Panels of size 190 X 2440 X 16 mm with micro perforation (3mm) In Front Side And 10mm Circular Hole Covered With Acoustical Fleece To Get (NRC 0.7). The Wooden Panel made of a High Density Fiber Board (HDMR) Substrate with one (1) mm Laminated (Mica) facing as per the approved Shade/species and finish, and a Melamine balancing layer over the reverse side. The density of HDMR board should be more than 800kg/m3. The HDMR board should be passed through vertically flammability test (UL94) and should be tested as for Anti-Fungal, The Panels with the help of special design Z clip as per the Drawing and Design would be fixed on the Aluminum Channel of size 15x25x19x7x.70mmx 3000mm Horizontally/Vertically over Gl frame work for wall paneling as per design drawing consisting of floor channel of size 50x32x32 x0.5mm thick at bottom and top fixed with 35 mm nylon sleeves and 35 mm screw. Further fixing Gl stud 48x34x36x0.5 mm thick @600mm C/C vertically. The framework to be filled with 50mm 1000 GSM non-woven thermal bonded polyester wadding held in position with 18 mm Gl chicken mesh of 24SWG with drywall screws and oversize washers. Finally fixing over it horizontally 80x26x51x0.5 mm thick G.J. ceiling section placed @600mm C/C or wherever required as per design drawings with dry wall screws and angle cleats 27x37x25x1.6 mm as required. The frame to be fixed to the walls by means of angle hold fastener cleats of required size, complete with expandable anchor fasteners of 65x10mm dia fixed on each vertical member @1000mm C/C. etc. as required, all complete as per the directions of Engineer-in-Charge |
| 4 | Fabric Acoustical Wall Paneling (0.9NRC):Providing and fixing of Fabric Acoustical Wall Paneling with square edges made of Rockwool with Glass-wool Tissue substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colors as per the choice of the Architect/ Engineering- in charge of size 600x1200 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC. The Gl Metal system includes G.I Stud having Size 48 mm X 36 mm x 34 mm X 0.50mm, length 3600mm and Floor Channel Size 50 mm X 32 mm X 32 mm X 0.50 mm, length3600 mm is fastener vertically/ horizontally at every 600mm filled with 50mm 1000 GSM nonwoven thermal bonded polyester wadding. Then 8 mm HDMR perforated Board should be Screwed to the Gl frame with the help of 25X 6 mm metal screw 25mm thick fabric acoustical panel should be pasted on the 8 mm HDMR perforated Board with the help of rubber base Adhesive of Pidilite or equivalent make as per drawing and design of Engineer-in Charge. |
| 5 | 20mm PET ACOUSTICAL PANELS:Providing and fixing 20 mm Pet acousitcal wall panel made of 11 mm perforated HDMR board as base and 9 mm pet acoustical panel pasted on the HDMR board in linear/approved shape. The Pet acoustical panel should be fixed on Gi frame work for wall paneling as per design drawing consisting of floor channel of size 50x32x32x0.5mm thick at bottom and top fixed with 35 mm nylon sleeves and 35 mm wooden screw. Further fixing Gl stud 48x34x36x0.5 mm thick @600 mm C/C vertically and Horizontally. The framework to be filled with 50mm 1000 GSM non-woven thermal bonded polyester wadding held in position with drywall screws and oversize washers. The frame to be fixed to the walls by means of angle cleats of required size complete with expandable anchor fasteners of 65x10mm dia fixed on each vertical member @1000mm C/C etc. as required all complete as per the directions of Engineer-in-Charge. Pet acoustical panel of size 190 X 2440 X 20 adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main `T`. The system should rest on periphery walls /partitions with the help of Gl perimeter wall angle of size 22x19x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic raw I plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T- sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. (Supplier Company should be OEM and same Test Certificates will be required from contractor before billing of the item). The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge. |
| 6 | 20mm Acoustical Rock Fiber False Ceiling (Bio-Safe):Providing and fixing Rock Fiber (Bio-Safe) Acoustical (NRC 0.9-0.95) Micro Look Edge False Ceiling Tile of size 595X595X20 mm of approved texture, design and pattern.Rock Wool Tile should have Acoustical Tissue Paper on the top face and Harden edge to achieve NRC upto 0.95 as per ASTMC423/ISO354. The tiles should have Anti Bacterial coating and Passed the Test Method as per JIS Z 2801: 2010, Should passed resistance to fungal attack test as per ASTM: G21-15. Relative Humidity (RH) more than 85%. Fire Performance as per Vertical flammability test (UL94) Classification VI (Flame extinguishes within 30 seconds with no dripping) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.30 mm thick (galvanized @120 GSM) comprising of main I runners of 15x32 mm (White/Black) of length 3000 mm, cross T of size 15x32mm (White/Black) of length 1200 mm and secondary intermediate cross T of size 15x32 mm (White/Black) of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80GSM) 50 mm long 8mm outer diameter M-6 dashfasteners, 4mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main `T`. The system should rest on periphery walls /partitions with the help of Gl perimeter wall angle of size 22x19x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic raw I plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T- sections used in false ceiling support system shall be pre- painted with polyester baked paint, for all heights. (Supplier Company should be OEM and same Test Certificates will be required from contractor before billing of the item). The work shall be carried out as per specifications, drawings and as per directions of the Engineer |
| 7 | Wooden Stage Flooring:Providing and fixing of Wooden Stage flooring complang 2 No. daggred vyen 12mm Thick HDMR Board fixed to Saal wood frame work of samo nervo of 600 mm C/C both ways (Sal wood frame work to be paid separately). The cool Wood Frame to be supported on 150x150x 5mm neoprene pods and held in postton b 35x35x5 mm angle cleats. The wooden Framework to be filled with 25 mm thick thermal bonded polyester wadding of 1000 GSM held in position fived on the s of the wooden framework with necessary screws and washers. Then 12 mm thick Wooden Laminated flooring Should be fixed on the staggered layer of Existing HOMR Board with required foam, Beading and skirting complete in all respect, the worl shall be executed as per drawing, Specificationis and instructions of Engineerin Charge. |
| 8 | Acoustical Cum Fire Rated Doors:Providing and fixing of Door Shutters 71 mm thick Acoustical Wooden door finished with Laminate on both side. Door Shutters shall be made in 2nd Class Teak wood frame of size 45 x 25mm. Door Shutters shall have both side 12 mm thick commercial Ply with One mm Laminate on both side. Polyester wool insulation of 50mm/1000gm density shall be kept between door shuters wooden frame of size 45 x 25 mm. 6 mm calcium silicate board and 2mm sound insulation sheets layers should be fixed in grooves of door shufers teak wood frames on both sides for Fire Rating. (The rates of Hinges. Handles, Door Stoppers, Lock Tower Bolts are included Except Panic Bar) Door Frame: Second Class Teak/Sal wood 125X75mm Chowkhat Frame should be fixed in the wall with good quality of fasterner and should be polished as per requirment of Engineer-In-Charge. |
| 9 | Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9. Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%. suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 23.29.2.3 1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 10 | Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9. Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%. suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 23.29.2.4 1400mm, service value = 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 11 | LED Down lighter (SMD Type) (System lumen efficacy =120 (135 lm/Watt)Supplying, installation. Testing and Commissioning of LED Recessed/surface Down lighter (Round/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz. Operating temp range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection THD (10%. P. F.20.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19. Flicker free (flicker should be below 5%), life time (LED, Driver and electrical circuitry), life fime of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. `complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C 23.28.2.4 18 watt |
| 12 | Supplying, installation. Testing and Commissioning of Panel light 2x2 ft. offollowing body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency )85%. Operating voltage AC 140-270 Volt, freq 50/60 hz. Operating temp range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection THD ( 10%, P. F.20.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19. Flicker free. (flicker should be below 5%), life time (LED, Driver and electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained fill life ends.CCT 3000°K/4000K/5700°K/6000K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc, as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast/Extruded aluminium Body (Thickness )1.20 mm) 23.28.7.4 36 watt |
| 13 | Supplying, installation, Testing and Commissioning of Street Right LED fixture bowder coat pressure die cast aluminum body with driver as per the requirement with friver efficiency )85%, Input voltage: 140-270 Volf AC, freq 50/60 Hz. Operating femp ronge -15 deg 16.10 deg centigrade, internal surge profection of 5KV LINE 65 ber IEC 61000-4-5 ver efficiency )85%, THD ( 10% as per IEC 61000-3-2, P.120.95P-66-16, CR 85/onder voltage and over vollage profection, EMI EMC As per CISPR 15, lenses for beam ongle ?? per IESNA type I/II/Ill as per the width of the road and the project requirement, sulfate 16 fit in up to 65mm dia pipe, life firme (LED Driver and electrical circulfry of minimum 50006 Burning Hours with 70% of initial Lumeri maintained fill life ends os per LABO ropotato IES TM-21-11 report, CCT 3000°K/4000°K/5700K/6000K/6500K (As per ANSI B SDCM(Standard Deviation Color Matching) (5, Maximum power consumersion should not more than the specified rating and fixture shall be of relevant BS standard complete i respect l/c connections with 1.5 sa mm FRLS, PVC insulated copper conductor angle 6618 cable and earthing etc, as required with Minimum 5 year OEM warranty, System umen efficacy 2120 (135 lm/Watt output. LM79 and LM80 Test report from NABL 165 for all festing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be466 approved by Engineer-in-Charge as per requirement. (Thermal management neof ink of aluminum housing such that LED juriction femperature shall not rise 6666 90°C 23.28.13.11 45 watt |
| 14 | Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz. Operating temp range-15 deg to 40 deg centigrade, internal surge profection of 2.5 KV with Short and Open circuit protection, THD ( 10%, P. F.20.95, IP20, CRI )80, Flicker free (flicker should be below 5%), life time (LED, Driver and electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000K /5700°K/6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) (3. Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/Embossing/Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures, complete in all respecti/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 23.28.10.1 18-22 watt |
| 15 | Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz. Operating temp range-15 deg to 40 deg centigrade, internal surge profection of 2.5 KV with Short and Open circuit protection, THD ( 10%, P. F.20.95, IP20, CRI )80, Flicker free (flicker should be below 5%), life time (LED, Driver and electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/4000K /5700°K/6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) (3. Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/Embossing/Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures, complete in all respecti/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output. LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 23.28.10.3 36 watt |
| 16 | SITC of LED Surface Mounted Square/Rect. Bulkhead Light. The Fixture should be Made of PDC Housing.PF).95. System Wattage 10w with Minium 100 lumens/W in 5700k. The Fixture should be IP-65 of Makes:-PHILIPS(WT202W LED6S NW PSU S2 PC)/BAJAJ (112334-81BWP TOW LED)/CGL: LBHN-10-CDL/GE/OSRAM/WIPRO/Havells) |
| 17 | SITC 6/9W LED aesthetically brillient surface picture/mirror light. The fixture comprises of aluminium/policarbonate. PF).95, System Wattage LED 5/6/9W with Minium 100 lumens/W in 5700k. The Fixture should be of Makes: BAJAJ (BCLSB 05 NW) /Havells (LUMILINE BS 9W LED 865 SPC WH) /CGL(CCS-103-05-65-SL-DP=NWH)/GE/OSRAM PHILIPS etc.) |
| 18 | SITC of 450mm Sweep wall Fan | Metal Body) complete as required Havells Sameera. Crompton or equivalent of USHA / Bajaj. |
| 19 | Supplying, installation, testing and commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain and hammer assembly complete with glass and push button etc. as required. |
| 20 | Supplying, installation, testing and commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate and suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 21 | Supplying, installation, testing and commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 22 | Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring and FRLS/HFFR outer sheath complete as required. |
| 23 | SITC of Cyclorama Screen in Plastic Perforated Material. The screen to be fixed on tubular frame made out of 40mm dia MS pipe and Cross MS Pipe 25mm. The system is to be provided with a motorised winch mechanism to be able to fly the cyclorama structure to the stage roof, to create a cyclorama-less stage for specific functions. The Cyclorama MS Framework is to be provided with wheels / castors for forward/backward movement.Size:32 x 22. Make: Prima, Glowvell, Dalite, Grandview |
| 24 | SITC of Main Curtain Mechanism with horizontal sliding arrangement Complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, I HP motor (Crompton) 2nos, air breaker contactors (LandT/SIEMENS), 2nos. micro switches for auto stop, 3 no`s push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering, with vertical lifting arrangement. Size:- 40 feet, Make: NEW/TAVS/OPE |
| 25 | SITC of Main Curtain ClothHigh quality Velvet fabric fire retardant treated as per approved colour and with a gathering of 100% stitched as per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies Size:40 ft x 20 ftMake: Reliance/Response/Nexgen |
| 26 | SITC of On Stage Fixed Frill Bar Straight as per the design made out of 25mm MS B Class Pipe, supported to hang the frill, connected with MS angle duly painted in black matt finish paint.Make: NEW/TAVS/OPE |
| 27 | SITC of Frill Glazed Cotton fabric Fire retardant treated as per approved colour and make with a gathering of 100% stitched as per site condition, curtain provided with eyelets of every 200/250mm for uniform fixing on to curtain trollies. Size: 40 feet x 3 feet Make: Reliance/Response/Nexgen |
| 28 | SITC of 200W Full Power Softlight Number of lamp beads: 2024 (1012 2835 warm white SMD LEDs plus 1024 2835 positive white SMD LEDS) Color temperature: 3200K-6000K adjustable Color rendering index: 295 Dimming: 0-100% linear dimming Beam angle: 135° Waterproof rating: IP20 Display: LCD touch screen Number of DMX channels: 2CH Features: Very simple operation, user-friendly design: three dimming methods, built-in button dimming, knob dimming, console dimming: dimming without flicker and jitter. stable performance, and temperature control detection protection. Advanced heat dissipation system design, natural heat dissipation, ultra-quiet, suitable for photography, photography, television and other occasions with very strict lighting requirements. Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 29 | SITC of LED Profile Spot Light Light Source: 300W LED Power Consumption: 390W Controls: DMX512, Master-slave, Sound activation or Auto DMX Channels: 1/3CH(single color).2/5CH(2in1). 3/7CH(RGB),4/8CH(RGBW) Life time: 50,000 hours Color: CW plus WW 2in1 (200w), RGB 4in1 (200w).CW or WW (200W/300W) Flash: 25times/sec Beam angle: 19°/26°/36°/50°optional Control panel: 4 LCD tube plus 4 press button DMX connector: 3-Pin XLR connectors IN/OUT (5-Pin optional) Dimmer: 0-100% linearly adjustable Protection rate: IP20Make: Martin, Robe. SX, Glowvell, Clay PakyMake: Martin, Robe, SX, Clay Paky |
| 30 | SITC of 100 watt x 4 LED COB Blinder Power consumption:400W Light source: LED 4×100W white and warm whiteAngel:60° Control mode: Auto,mater/slave, DMX512 DMX512 Channel:2/6/12CH Color temoerature:3000-5600K Cover:aluminum Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 31 | SITC of LED Fresnel Light with ZOOM Light Source: 300W Power Consumption: 320W Controls: DMX512 Sound activation, Auto, Master/Slave DMX Channels: 2CHS Life time: 50000 hours Cooling system: air cooling Flash: 0-25/sec Color temperature: 3200K±5% (cool white)/5600K±5% (warm white) The best projection distance: 4-30 meters Lens Angle: 20-55° Control panel: 4 LCD tube Dimmer: 0-100% linearly adjustable Protection rate: IP20 Working environment: -25~40° Material: aluminium alloy plus organic glass manufacture Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 32 | SITC of 6 in 1 LED Par Light Light source: 18 * 12W (RGBWA plus UV 6 IN 1JLED Life Time: 50000 hours Beam angle: 25 deg ( 10 deg , 30° option) Control panel: 4 Digital LED display figures Control mode: sound activation, auto, master/slave, DMX-512 DMX channels: 8/10 CHS Dimmer: 0-100% with regulated constant color control Working environment: up to 40°C Protection rate: IP20 Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 33 | SITC 6 Cyclorama LED Bar Light Rated power consumption: 150M Light bulb specification: 1866 10W (AK) Service life: 60000 hours Color temperature 6000K-6500K Beam angle: 25` (45° optional) Control panel: 4-Key digital LED display Control mode: Sound activation, Auto, master-dove connection DMX-512 DMX channel: 9/23/72CHS Dimming: 0-100% adjustable and stable col cont Stroboscopic: Electronic flash pulse and random effect, 10 mess Housing Aluminium Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 34 | SITC of 3 in 1 Moving Head LED Profile Light LED Source: 250W LED Pan: 540 degree. Tilt: 270 degree DMX512, Master/slave, Sound, Auto mode DMX Channel: 16ch/14ch Dimmer from 0-100%, Strobe Zoom angle: 4.5°-22° 3 phase motor 1 Rotation Gobo Wheel: 5 gobos plus 2 open Pattern vibration effect 1 Color wheel: 7 main colors plus open with rainbow effect, color fine tuning 8-facet prism, Rotation prism, Focus Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 35 | SITC of 3 in 1 Moving Head Hybrid Profile Light DMX channel: 24 channels Operation mode: DMX512/Manual/Auto LCD LED display OSRAM SIRIUS HRI 371 W Lamp Pan/Tilt motor, ultra-quiet, ultra-high speed three-phase motor Color Temperature 8500K, Life time 2000 hours 14 colors plus white, half color effect 9 rotated gobo plus white 1 fixed gobo wheel 15 plus 1 Prism: Rotating double 8 plus 16 prism and single 8, 16 prism prism can be used to superimpose multi-layer beam effect Prism can be linearly amplified Optical lens: high precision glued optics Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 36 | SITC of Fixturé Rigging Hardware (Lot) MS fixture rigging hardware Powder coated in black matt texture finish Make: Custom |
| 37 | SITC of Power Distribution Electrical panel Having a Incomer of 63A, wall mount Neutral separation made using incomer of LST or Schneider make, Individual MCB control for 40 outgoing circulls intermally wined using IS certified wires and cables Provided with ivory connectors for the internal terminations and external outgoing connecting points Custom built as per specification and project requirement. Make: Custom |
| 38 | SITC of 512 Channels DMX Console Software Based Digital DMX / RDM Control System Acer/AOC 21` Multi touch screen (10 point touch) System10x 60 mm playback faders, each with 4x function-assignable buttons4 Onboard universe expandable up to 128 universe Including 4 x 4 Channel DMX splitter, Total 16 DMX outputs8x customizable multi-function keys Playback Select button Master Go section with Go, Pause, Snap and Release 4x digital rotary encoders with push function and status LED for fixture parameter control 3.5` RGB touchscreen for parameter groups, effect parameters, fanning and global timings Grand master rotary fader and button Blind/Highlight/Last/Next buttons Full numerical keypad and command keys Make: Martin, Robe, SX, Glowvell, Clay Paky |
| 39 | SITC of CPU with Lifetime Licence Pro Lighting Software i5 Processor, 8GB RAM, 1TB SSD Drive Wireless Keyboard And Mouse Licenced Windows 11 Make: Dell/Acer/Lenovo |
| 40 | SITC of High Quality Power Junction Box Made up of MS Sheet metal fabricated housing black powder coated box 1 x 6 Amp 3 pin power socket Make: Custom |
| 41 | SITC of High Quality Power Junction Box Made up of MS Sheet metal fabricated housing black powder coated box 2 x Pro grade DMX male/female sockets Make: Custom |
| 42 | SITC of Black Powder coated cable trays Made out of MS Sheet fabricated for a size of 300mm With perforation for heat dissipation provided with lid. Make: Custom |
| 43 | SITC of Black Powder coated cable trays Made out of MS Sheet fabricated for a size of 75mm With perforation for heat dissipation provided with lid. Make: Custom |
| 44 | SITC of Pro Grade DMX Connectors High conductivity 3 Pin DMX connectors Make: Neutrik/Amphenol/Krystals/Setmi |
| 45 | SITC of 2.5 Sq/mm 3 Core Copper Flexible Power Cable FR Grade PVC insulation Make: Finolex/Havells/Krystals |
| 46 | SITC of 2 Core Shielded Digital DMX Cable Ultra low noise digital DMX cable Make: Falcon/Krystals/Altec |
| 47 | [10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. [Through Rate] |
| 48 | [10.107]Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0 [Through Rate] |
| 49 | [10.30.4]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 4. Ordinary cement without any pigment [Through Rate] |
| 50 | [10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick [Through Rate] |
| 51 | [10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [Through Rate] |
| 52 | [10.42]Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. [Through Rate] |
| 53 | [10.43]Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. [Through Rate] |
| 54 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 55 | [10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate] |
| 56 | [10.60]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [Through Rate] |
| 57 | [10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 58 | [11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate] |
| 59 | [11.27.2]Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : 2. Raised and cut pointing [Through Rate] |
| 60 | [11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate] |
| 61 | [11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) [Through Rate] |
| 62 | [11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate] |
| 63 | [11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate] |
| 64 | [11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate] |
| 65 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 66 | [12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm [Through Rate] |
| 67 | [12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm [Through Rate] |
| 68 | [12.103.2]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper [Through Rate] |
| 69 | [12.12.2]Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 2. 1.0 mm thick [Through Rate] |
| 70 | [12.137.5]Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. 5. 400 x 19 x 1.9 mm [Through Rate] |
| 71 | [12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 72 | [12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate] |
| 73 | [12.160.1]Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 1. With stainless steel cover plate minimum 1.25 mm thickness [Through Rate] |
| 74 | [12.172.1]Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F and ISO 11600 1. Up to 5 mm depth and 5 mm width [Through Rate] |
| 75 | [12.172.2]Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F and ISO 11600 2. Up to 10 mm depth and 10 mm width [Through Rate] |
| 76 | [12.177.1]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With toughened glass panes of 6 mm thickness (weight not less than 15 kg/sqm) [Through Rate] |
| 77 | [12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 78 | [12.39]Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). [Through Rate] |
| 79 | [12.42]Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). [Through Rate] |
| 80 | [12.89]Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. [Through Rate] |
| 81 | [12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm [Through Rate] |
| 82 | [12.98.2]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm [Through Rate] |
| 83 | [12.99.1]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 300x10 mm [Through Rate] |
| 84 | [12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm [Through Rate] |
| 85 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 86 | [13.5.3]Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 3. 10 x 120 mm [Through Rate] |
| 87 | [20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall [Through Rate] |
| 88 | [20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate] |
| 89 | [20.49.1]Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. 1. Up to 200 mm internal diametre [Through Rate] |
| 90 | [20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 91 | [21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate] |
| 92 | [21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate] |
| 93 | [22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore [Through Rate] |
| 94 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 95 | [22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate] |
| 96 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 97 | [22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate] |
| 98 | [22.110.1]Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 1. 15 mm nominal bore [Through Rate] |
| 99 | [22.115.2]Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 2. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms [Through Rate] |
| 100 | [22.117]Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. [Through Rate] |
| 101 | [22.118]Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. [Through Rate] |
| 102 | [22.14.2.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.1. Flexible pipe 32 mm dia [Through Rate] |
| 103 | [22.166.2.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 2.1. 150 x 100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 104 | [22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate] |
| 105 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 106 | [22.221.8]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 8. Size 630mm x 500mm (above counter oval) [Through Rate] |
| 107 | [22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 108 | [22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 109 | [22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. [Through Rate] |
| 110 | [22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate] |
| 111 | [22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate] |
| 112 | [22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate] |
| 113 | [22.50.1.2.1]Providing and fixing partitions for different type of urinals. 1.2.1. Vitreous Chinaware Partition plate. Large size 835mm x 355 mm White [Through Rate] |
| 114 | [22.53.1]Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1. For 100 mm dia pipe [Through Rate] |
| 115 | [22.53.2]Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 2. For 75 mm dia pipe [Through Rate] |
| 116 | [22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 117 | [22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 118 | [22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate] |
| 119 | [22.85.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 6. 50 mm nominal outer dia Pipes [Through Rate] |
| 120 | [22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate] |
| 121 | [22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 122 | [22.86.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 123 | [22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 6. 50 mm nominal outer dia Pipes [Through Rate] |
| 124 | [22.98.1]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore [Through Rate] |
| 125 | [22.98.2]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore [Through Rate] |
| 126 | [22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. [Through Rate] |
| 127 | [22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore [Through Rate] |
| 128 | [22.98.5]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 5. 50 mm nominal bore [Through Rate] |
| 129 | [23.11]Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required [Through Rate] |
| 130 | [23.12]Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required [Through Rate] |
| 131 | [23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate] |
| 132 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate] |
| 133 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 134 | [23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB [Through Rate] |
| 135 | [23.22.3.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.3. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. TPN enclosure suitable for TP , TPN or FP MCB [Through Rate] |
| 136 | [23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 137 | [23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 138 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 139 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 140 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 141 | [23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A [Through Rate] |
| 142 | [23.22.6.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.6. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. FP RCCB 30ma sensitivity , 63 A [Through Rate] |
| 143 | [23.22.8.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts [Through Rate] |
| 144 | [23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate] |
| 145 | [23.24.3.6]MS STAND, BUS BAR CHAMBER AND PANELS 3.6. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 200 amp 4 bars of 100 cm each (cross section 38 mm x 6mm) chamber over all size 1.10 m x 45 cm x 18cm [Through Rate] |
| 146 | [23.24.4.1]MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. [Through Rate] |
| 147 | [23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate] |
| 148 | [23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate] |
| 149 | [23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate] |
| 150 | [23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 151 | [23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] |
| 152 | [23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 153 | [23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate] |
| 154 | [23.3.6.6]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 155 | [23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate] |
| 156 | [23.4.2.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate] |
| 157 | [23.4.3.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C [Through Rate] |
| 158 | [23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C [Through Rate] |
| 159 | [23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C [Through Rate] |
| 160 | [23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate] |
| 161 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 162 | [23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate] |
| 163 | [23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate] |
| 164 | [23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. [Through Rate] |
| 165 | [23.8.1.5]FITTING AND ACCESSORIES 1.5. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type [Through Rate] |
| 166 | [23.8.1.6]FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type [Through Rate] |
| 167 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] |
| 168 | [23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate] |
| 169 | [23.8.10.3]FITTING AND ACCESSORIES 10.3. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 4 Modules [Through Rate] |
| 170 | [23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules [Through Rate] |
| 171 | [23.8.10.5]FITTING AND ACCESSORIES 10.5. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 8 Modules [Through Rate] |
| 172 | [23.8.10.6]FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules [Through Rate] |
| 173 | [23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate] |
| 174 | [23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate] |
| 175 | [23.8.11.2]FITTING AND ACCESSORIES 11.2. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 2 way switch [Through Rate] |
| 176 | [23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate] |
| 177 | [23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate] |
| 178 | [23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate] |
| 179 | [23.8.11.6]FITTING AND ACCESSORIES 11.6. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Bell Push [Through Rate] |
| 180 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 181 | [23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate] |
| 182 | [23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type [Through Rate] |
| 183 | [23.8.3.1]FITTING AND ACCESSORIES 3.1. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 75 mm x 75 mm x 60 mm deep M.S. box [Through Rate] |
| 184 | [23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate] |
| 185 | [23.9]Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. [Through Rate] |
| 186 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 187 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 188 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 189 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] |
| 190 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 191 | [24.11.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITH SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 70. 120 Sq mm 3.5 core (Arm.) [Through Rate] |
| 192 | [24.14.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate] |
| 193 | [24.14.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.) [Through Rate] |
| 194 | [24.14.76]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 76. 150 Sq mm 3.5 core (Arm.) [Through Rate] |
| 195 | [24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate] |
| 196 | [24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate] |
| 197 | [24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate] |
| 198 | [24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm [Through Rate] |
| 199 | [24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm [Through Rate] |
| 200 | [24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate] |
| 201 | [24.4.3]STREET LIGHT 3. Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. [Through Rate] |
| 202 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 203 | [24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate] |
| 204 | [28.16]Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. [Through Rate] |
| 205 | [30.16.1]Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 1. With cement mortar 1:4 (1 cement : 4 fine sand) [Through Rate] |
| 206 | [30.22]Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. [Through Rate] |
| 207 | [30.37.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. Old work (Two or more coat applied @ 1.67 litre/ 10 sqm) on existing cement paint surface [Through Rate] |
| 208 | [30.88.1]Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1. For pipes 100 to 250 mm diameter [Through Rate] |
| 209 | [31.14.1]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 1. 8mm dia (hole size 12 mm dia & depth up to 80 mm) [Through Rate] |
| 210 | [31.14.2]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 2. 10 mm dia (hole size 14 mm.& hole depth up to 100 mm) 0 0 [Through Rate] |
| 211 | [31.14.3]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 3. 12mm dia (hole size 16mm.& hole depth up to 120 mm) 0 0 [Through Rate] |
| 212 | [31.14.4]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 4. 16mm dia (hole size 20 mm dia & depth up to 200mm) 0 0 [Through Rate] |
| 213 | [31.14.5]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 5. 20mm dia (hole size 24 mm dia & depth up to 240mm) 0 0 [Through Rate] |
| 214 | [31.2.3]Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 3. 25 mm average thickness [Through Rate] |
| 215 | [31.4.2]Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. 2. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make [Through Rate] |
| 216 | [36.11.2]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 2. 50 mm dia [THROUGH RATE] |
| 217 | [36.11.4]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 4. 80 mm dia [THROUGH RATE] |
| 218 | [36.11.5]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 5. 100 mm dia [THROUGH RATE] |
| 219 | [36.13]Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to thelevel of 3.5 kg/cm2 complete as required. [THROUGH RATE] |
| 220 | [36.14.5]Providing, installation, testing and commissioning of nonreturn valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washersnetc.as required: 5. 100 mm dia [THROUGH RATE] |
| 221 | [36.16.2]Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: 2. Stainless Steel (Grade 304) [THROUGH RATE] |
| 222 | [36.17.1]Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type 2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve and nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 1. 30m [THROUGH RATE] |
| 223 | [36.18.2]Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required: 2. Stainless Steel (Grade 304) [THROUGH RATE] |
| 224 | [36.19.1]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 1. 2 way-100 mm dia M.S. Pipe [THROUGH RATE] |
| 225 | [36.20]Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve withrequired accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. [THROUGH RATE] |
| 226 | [36.22.1]Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. 1. 100mm dia [THROUGH RATE] |
| 227 | [36.23.1]Providing and fixing flow switch in following sizes M.S. pipe including connection etc as required. 1. 100mm dia [THROUGH RATE] |
| 228 | [36.30]Providing, fixing, testing and commissioning of ISI marked (ISI MARK 15683) portable CO2 fire extinguisher of capacity 4.5 kg including valve,horn,suitable handle, discharge hose of one meter long complete in all respect with explosive certificate . [THROUGH RATE] |
| 229 | [36.4.1](a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation,conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 1. 900 lpm at 35 M Head [THROUGH RATE] |
| 230 | [36.41]Providing, fixing, testing and commissioning of dial type Stainless Steel Pressure Gauge with brass isolation valve and steel/cooper pipe complete in all respect. [THROUGH RATE] |
| 231 | [36.46]Providing, fixing, testing and commissioning of gun metal ball valve suitable for pressure 15 kg/Cm2 and confirming to IS: 778 of the following size including union/ flange complete in all respect. Size 25 MM DIA [THROUGH RATE] |
| 232 | [36.49]Supply, Insallation, testing and commissioning of Electrical fire pump panel for terrace fabricated with 2mm thick Ms sheet with hinged lockable doors, powder coated of approved shade including all accessories complete in all respect. 900 LPM [THROUGH RATE] |
| 233 | [36.52]Providing, fixing, testing and commissioning of Wall Mounted or Free Standing Type , Weather proof hose cabinet of size 750 x 600 x 250mm with glazed double door fabricated with MS sheet of 16 gauge to accumulate 2 nos. Delivery Hoses of 15m lenght and Branch Pipe complete in all respect. [THROUGH RATE] |
| 234 | [36.53]Providing, fixing, testing and commissioning of Wall Mounted or Free Standing Type , Weather proof hose cabinet of size 350x 300 x 250mm with glazed single door fabricated with MS sheet of 16 gauge to accumulate 1 no. Delivery Hose of 15m length and Branch Pipe complete in all respect. [THROUGH RATE] |
| 235 | [36.7.1]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 1. 25 mm dia [THROUGH RATE] |
| 236 | [36.7.6]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 6. 80 mm dia [THROUGH RATE] |
| 237 | [36.7.7]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 7. 100 mm dia [THROUGH RATE] |
| 238 | [36.8.4]Providing, laying, testing and commissioning of `B` class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceilingwith suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 4. 50 mm dia [THROUGH RATE] |
| 239 | [36.9.1]Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steelcap and chain as required. 1. Single headed Stainless steel [THROUGH RATE] |
| 240 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate] |
| 241 | [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate] |
| 242 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 243 | [5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate] |
| 244 | [5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate] |
| 245 | [5.27]Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. [Through Rate] |
| 246 | [5.29.1]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1. Of area 3 sq. metres and below [Through Rate] |
| 247 | [5.29.2]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2. Of area beyond 3 sq. metres [Through Rate] |
| 248 | [5.42]Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. [Through Rate] |
| 249 | [5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. [Through Rate] |
| 250 | [5.49]Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. [Through Rate] |
| 251 | [5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate] |
| 252 | [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 253 | [6.1.7A]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7A. 1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size including Recycled Aggregate (RA)) [Rate] |
| 254 | [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 255 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 256 | [6.30.16.1]Centering and shuttering including strutting, propping etc. and removal of form for 16.1. Edges of slabs and breaks in floors and walls Under 20 cm wide [Through Rate] |
| 257 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 258 | [6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) [Through Rate] |
| 259 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 260 | [6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate] |
| 261 | [7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 262 | [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 263 | [7.83.1]Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with : 1. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 264 | [7.84.1]Random rubble masonry with hard stone in superstructure above plinth level and up to floor four level, including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. 1. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 265 | [7.85.1]Extra for random rubble masonry with hard stone in : 1. Square or rectangular pillars [Through Rate] |
| 266 | [7.86]Extra for random rubble masonry with hard stone curved on plan for a mean radius not exceeding 6 m. [Through Rate] |
| 267 | [8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shade Area of slab up to 0.50 sqm [Through Rate] |
| 268 | [8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm [Through Rate] |
| 269 | [8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate] |
| 270 | [8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate] |
| 271 | [8.5]Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete. [Through Rate] |
| 272 | [9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 [Through Rate] |
| 273 | [9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate] |
| 274 | [9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate] |
| 275 | [9.46.4]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 4. Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer s specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 [Through Rate] |
| 276 | [9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate] |
| 277 | [9.58.1.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm [Through Rate] |
| 278 | [9.58.1.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm [Through Rate] |
| 279 | [9.58.4.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.2. Single tee without door 110x110x110 mm [Through Rate] |
| 280 | [9.58.5.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.1. Bend 87.5° 75 mm bend [Through Rate] |
| 281 | [9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate] |
| 282 | [9.62.1]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 1. 100 mm diameter [Through Rate] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer