Tender For special Repair To Bldg No P-19 (1) & (2) (Storage Accn) & special Rep Of Interlocking Tiles Near Mf Hanger Of 207 Army Avn Sqn (Uh) At Manasbal, Provn Of Main Gate At 254 Transit C And Provn Of Drinking Water Connected Through Hdpe Pipe To
Tender Overview
Project Description
Tender for special Repair To Bldg No P-19 (1) & (2) (Storage Accn) & special Rep Of Interlocking Tiles Near Mf Hanger Of 207 Army Avn Sqn (Uh) At Manasbal, Provn Of Main Gate At 254 Transit C And Provn Of Drinking Water Connected Through Hdpe Pipe To D Coy Ex 115 Inf Bn (Ta) Mahar At Sonamarg Under Ge 970 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 2 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws upto the height of 15 m complete all as specified and directed. |
| 3 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding, to wall, eaves board and roof bottom , fixed with self tapping screws upto the height of 15 m complete all as specified and directed. |
| 4 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, Eaves board and roof chajja and similar work conforming to Fe.290.Gde-E-165 upto the height of 15 m complete all as specified and directed. |
| 5 | Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 6 | S&F Anodised aluminium snap grid frame work 605 x 605mm for false ceiling complete all as specified and directed. |
| 7 | S&F Providing and fixing Gypsum Board 12 mm thick decorative type in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed. |
| 8 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with water proofing compound @2% by weight of cement and finished surface even and smooth without using extra cement including necessary scaffolding etc. Note : WPC shall be measured & paid saperatly here in under. |
| 10 | Supply only WPC complete all as specified and directed. |
| 11 | M&L 15mm thick rendering in cement mortor 1:6 on fair faces of brick work and finishing surface even and smooth without using extra cement complete all as specified and directed. |
| 12 | M&L Applying two coats of Distemper oil emulsion, white or tinted over 1 mm thick wall care putty on new wall surface including preparation of surface all complete and as specified. |
| 13 | M&L for complete removal of existing treatment and applying two coat of oil bound distemper over 1mm thick birla white putty including preparation of surface complete all as specified and directed. |
| 14 | M&L for complete removal of existing treatment and applying two coat of exterior emulsion weather proof paint over one coat of exterior wall primer incl. preparation of surface of old decorated walls etc , properly making of v shape cracks and filling of all cracks with cracks seal of walls complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for applying two coat of exterior emulsion weather proof paint over one coat of exterior wall primer incl. preparation of surface of new plastered surface of walls complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L Applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface, complete all as specified and directed. |
| 17 | M&L Applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface, complete all as specified and directed. |
| 18 | M&L Applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of pink primer, complete all as specified and directed. |
| 19 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 20 | Taking down chowkat or frames exc 1.5 Sqm but n exc 4.0 Sqm each with shutter (without taking off shutters from the frame), complete all as specified and as directed. |
| 21 | S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 22 | S&F 30mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats complete all as specified and directed. |
| 23 | S&F 30 mm thick Flush shutters, solid core construction, with particle board core & plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified. |
| 24 | S&F in stainless steel Butt hinges 125mm size, medium weight, complete all as specified and as directed. |
| 25 | S&F in extruded Aluminium alloy handles 150mm size, cast type, anodised complete all as specified and as directed. |
| 26 | S&F in Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and as directed. |
| 27 | Dismantling of Stone slabs and tile laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and as directed. |
| 28 | M&L Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and as directed. |
| 29 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado & pillar over 15mm thick plater in CM (1:6) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and as directed. |
| 30 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 31 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm,in skirting including backing coat of 10 mm thick CM 1:6 on fair faces of brickwork or concrete surface complete all as specified and as directed. |
| 32 | Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed. |
| 33 | M&L 75 mm thick Cement concrete type C2 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 34 | Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles, complete all as specified and directed. |
| 35 | M&L for Old size brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed. |
| 36 | S&F 200 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 37 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified by Engr in Charge. |
| 38 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified and directed. |
| 39 | Taking down copper / alluminium point wiring (light, fan, socket or power) complete by removing all switches, socket, ceilling rose, pendent etc., excluding light fitting and making good the distributed surfaces as existing surfaces, complete all as specified and directed. |
| 40 | Taking down old and UNSV submain wiring any size of two core including earthwire complete including batten/ conduit and making good the distributed surfaces to match the existing surfaces, complete all as specified and directed. |
| 41 | Taking down old and UNSV, DB any type including changeover, fuses, MCBs etc., after removing all connection and making good the distributed surfaces to match the existing surfaces, complete all as specified and directed. |
| 42 | Material and Labour for concealed point wiring using FRLSH PVC Insulated, unsheathed, multi stranded copper conductor cable 1.5 Sqmm, drawn through medium grade rigid PVC conduits of 19/20 mm diameter. This includes all conduit fittings such as tees, bands, sockets and junction boxes, along with a 1.5 sq mm FRLSH PVC insulated, unsheathed copper conductor for Earth continuity. Provide necessary arrangements to accomodate Modular flush boxes, complete all work as specified and directed. |
| 43 | All as per the item No 42 above but 5 Amp socket outlet on independant board all as specified and directed by Engr-in-charge. |
| 44 | All as per the item No 42 above but for one socket outlet 15 Amps on Independent board using cable (2.5 Sq mm for Phase & neutral and 2.5 Sq mm for Earthing) complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F of DBs double door SPN-8 way, 230 volts, AC supply, with 100 Amp rated Bus Bar, Earth Bar & Neutral Bar, IP 54, IS-8623, sheet metal enclosure complete all as specified and directed. |
| 46 | S&F of SPN 32 Amperes, 240V, 10 kA, AC supply, 'C' curve miniature circuit breaker (MCB) all as specified and as directed. |
| 47 | S&F of MCB SP 6 to 32 Amperes, 240V, 10 kA, 'C' curve, AC supply all as specified and as directed. |
| 48 | S&F for switch Modular type single pole one way 5 amps 240 volts, with one module, including suitable for cover plate and connected accessories complete all as specified and directed. |
| 49 | S&F for Modular switch socket combination 2 in 1, 5 pin, 6 amp flush type with 3 Module including suitable for cover plate and connected accessories complete all as specified and directed. |
| 50 | S&F LED street light fitting 60 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete |
| 51 | S&F for Modular switch socket combination 2 in 1, 5 pin, 15 amp flush type with 3 Module including suitable for cover plate and connected accessories complete all as specified and directed. |
| 52 | S&F for White cover plate with frame of 1 Module complete all as specified and directed. |
| 53 | S&F for White cover plate with frame of 3 Module complete all as specified and directed. |
| 54 | S&F Metal Flush box for 1 Module complete all as specified and directed. |
| 55 | S&F Metal Flush box for 3 Module complete all as specified and directed. |
| 56 | S&F ceiling rose 3 terminal size 50x 65 mm surface type complete all as specified and directed. |
| 57 | S&F of 1x20 Watts LED 6500K (4 ft) decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded aluminium body heat shrink, provided for efficient dissipation and integrated electronic driver complete with lamp. |
| 58 | M&L of Sub main wiring complete, two run of 6 Sqmm and one run of 1.5 Sqmm with copper conductor, multi stranded, FRLSH, PVC insulated and sheathed, 1100 Volts grade, incl drawn through PVC suitable size conduit. |
| 59 | Demolition of interlocking tiles ,Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) incl PCC and removal complete all as specified and directed by Engr-In-Charge. |
| 60 | M&L for 100mm PCC 1:4:8 type D2 (40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 61 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as per IS-15658-2006 as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. |
| 62 | M&L Providing, cement concrete (1:2:4) type B-1(using 20 mm graded agg) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 63 | Earth work in excavation (any type of soil) by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 64 | M&L PCC (1:5:10) type E2 using 40mm graded aggregate in foundation & mass concrete all as specified and directed. |
| 65 | M&L Providing and laying in position reinforced cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified & directed. |
| 66 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1½:3 (1 Cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified & directed. |
| 67 | M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 68 | M&L Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders complete all as specified and directed. |
| 69 | Use & Waste for Formwork to sides of concrete foundations, footings, bases of columns, columns up to PB and plinth beams; and similar work; vertical or to batter Fair finished surfaces complete all as specified and directed. |
| 70 | Use & Waste for Formwork to sides of pillars, posts, struts, piers, columns etc fair finished surface complete all as specified and directed. |
| 71 | S&F Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation including Base frame work for ACP cladding The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in Sqm. up to two decimal places. |
| 72 | S&F Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates , rolling track including all necessary fixtings and similar works complete all as specified and directed. |
| 73 | M&L Mild steel plates of any size and thickness, complete all as specified and directed. |
| 74 | Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed. |
| 75 | Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point complete all as specified and directed. |
| 76 | M&L Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work, complete all as specified and directed. |
| 77 | S&F Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including as elbows, tees, reducers, sockets, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge, Exterrnal work : PN - 10 Pipe, 50 mm Outer Diameter (SDR-11) |
| 78 | S&F of monoblock pumpset, 3 phase system, 415 volts, capacity 2 HP, size 65 mm x 50 mm complete fittings with DOL (Direct On Line) starter installation. |
| 79 | S&F Providing and fixing PPR Unions of 50 mm complete, all as specified and directed by Engr-in-Charge. |
| 80 | S&F Providing and fixing gun metal non- return valve of approved quality (screwed end) of 50 mm nominal bore vertical complete, all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender