Tender For Repairs / Maintenance Of Various Chiller Units Of Centralised Ac Plants Of Make Voltas In Naval Station, Bheemunipatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
22 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
15 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs / Maintenance Of Various Chiller Units Of Centralised Ac Plants Of Make Voltas In Naval Station, Bheemunipatnam

BOQ

Name of Work:- REPAIRS / MAINTENANCE OF VARIOUS CHILLER UNITS OF CENTRALISED AC PLANTS OF MAKE VOLTAS IN NAVAL STATION, BHEEMUNIPATNAM
Sl. No. Item Description
1M&L for carrying out complete the rectification of compressors, condensers and evaporator system of capacity 15 TR (2 x 7.5 TR) AC plant and panel. Make : Voltas AWS NAD including panel, compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming including gas filling etc, in serviceable and operational condition complete all as manufacturers instruction with following items as given below and directed.
2Note: (i) The rate quoted shall be deemed to include for necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets drier core filter etc to put into AC Plant and panels in serviceable condition, testing and commissioning complete all as directed by the Engr-in-charge.(ii) New spare parts required for replacing old parts shall be measured and paid separately against ‘Supply only’ under item No 1.03 to 1.07 here-in-after, labour rate quoted shall be deemed to have been inclusive of such items.
3(iii) Any minor spares/parts/accessories not covered in the Schedule \\"A\\" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Servicing of control wiring in the system/panel operating parameter microprocessor, motherboard communication, control board, transducers etc, is deemed to be included in the rate.(v) Servicing shall be carried out through OEM /authorised Agency only and test report shall be submitted in duplicate.
4Supply only Package Unit machine monitoring display complete set Unit Model : DPUWSC55 or equivalent
5Supply only MPD, PMN, and controller. Unit Model : APUWSC55.
6Supply only Refrigerants gas R-22
7Supply only pressure switch
8Supply only Expansion valve existing model.
9M&L for carrying out complete the rectification of compressors, condensers and evaporator system capacity of 3 x 25 TR AC Plant Make: Voltas Model no WCDSO24DMN P 206 NAD including panel, condenser, evaporator recommissioning re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including brazing of liquid and discharge line, leak test, pressure test, nitrogen test, Vacuuming, gas filling etc, in serviceable and operational condition complete all as manufacturers instruction with following items as given below all as directed by Engr-in-charge.
10Note: (i) The rate quoted shall be deemed to include for necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets drier core filter etc to put into AC Plant and panels in serviceable condition, testing and commissioning complete all as directed by the Engr-in-charge.(ii) New spare parts required for replacing old parts shall be measured and paid separately against ‘Supply only’ under item No 2.03 to 2.10 here-in-after, labour rate quoted shall be deemed to have been inclusive of such items.
11(iii) Any minor spares/parts/accessories not covered in the Schedule \\"A\\" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Servicing of control wiring in the system/ panel operating parameter microprocesor, motherboard communication, control board, transducers etc, is deemed to be included in the rate.(v) Servicing shall be carried out through OEM/authorised Agency only and test report shall be submitted in duplicate.
12Supply only Compressor Model : SM18534RC in cluding brazing.
13Supply only presssure switch
14Supply only of Contractor set for 3 pole contyractor AC3, 32 Amps as existing
15Supply only MVPD & Temperatue sensor
16Supply only MCCB 3 pole, 35KA 100 Amp from the existing pannel, adjustable type.
17Supply only PCB Board Sr No D.F. 3C-15116-59 complete with all accessory and suitable fixing in existing
18Supply Expansion valve existing model .
19Supply only Refrigerants gas R-407
20M&L for carrying out complete the rectification of compressors, condensers and evaportor system capacity of 3 x 39 TR. Make : Voltas Model no WCUR0400MNT in MARCOS including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming, gas filling etc, in serviceable and operational condition complete all as manufacturers instruction and as directed by Engr-in- charge.
21Note: (i) The rate quoted shall be deemed to include for necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets drier core filter etc to put into AC Plant and Panels in serviceable condition, testing and commissioning complete all as directed by the Engr-in-charge.(ii) New spare parts required for replacing old parts shall be measured and paid separately against ‘Supply only’ under item No 3.03 to 3.07 here-in-after, labour rate quoted shall be deemed to have been inclusive of such items.
22(iii) Any minor spares / parts /accessories not covered in the Schedule \\"A\\" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM /authorised Agency only and test report shall be submitted in duplicate.
23Supply only Compressor Model : SM18554RC and MPD incl copper brazining. Model : WCUR0400MNT
24Supply only MPD supply 230 VAC. Model: WCUR0400MNT
25Supply only Expansion valve existing model.
26Supply only Refrigerants gas R-407
27Supply only PCB Board Sr No D.F. 3C-15116-59 complete with all accessory and suitable fixing in existing
28M&L for carrying out complete the rectification of compressors, condensers and evaportor system capacity of 3 x 50 TR Hanger 11 Make : Voltas including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming, gas filling etc, in serviceable and operational condition complete all as per manufacturers instruction and with following items as given below complete all as directed by Engr-in-charge.
29Note: (i) The rate quoted shall be deemed to include for necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets drier core filter etc to put into AC Plant and panels in serviceable condition, testing and commissioning complete all as directed by the Engr-in-charge.(ii) New spare parts required for replacing old parts shall be measured and paid separately against ‘Supply only’ under item No 4.03 to 4.10 here-in-after, labour rate quoted shall be deemed to have been inclusive of such items.
30(iii) Any minor spares/parts/accessories not covered in the Schedule \\"A\\" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Servicing of control wiring in the system/panel operating parameter microprocessor, motherboard communication, control board, transducers etc, is deemed to be included in the rate.(v) Servicing shall be carried out through OEM /authorised Agency only and test report shall be submitted in duplicate.
31Supply only pressure switch.
32Supply only Contactor Set for 3 pole contactor AC3, 32Amps as existing.
33Supply only MVPD & Temperature sensor.
34Supply only Refrigerants gas R-407
35Supply only Compressor Model : SM18554RC and MPD incl copper brazining. Model : WCUR0400MNT
36Supply only MCCB 3 pole, 35 KA 100 Amp from the existing pannel, adjustable type.
37Supply only expansion valve
38Supply only PCB Board Sr No D.F. 3C-15116-59 complete with all accessory and suitable fixing in existing
39M&L for carrying out attending to break down of central type AC plant of capacity upto 60 TR by only auth OEM (M/S VOLTAS) rep/team for fault finding incl attending repairs as and when required such as no start condition of AC plant and repairing, starting, the operating parameter of the chillers checking any vibration, functioning microprocessor, flow swich calibration, HP/LP cut out swich, oil pump and oil heater the AC plant till smooth running and setting up the alignment required parameter of all major/minor parts such as compressor microprocessor based central AC plant, general repair smooth and trouble free operation of plant to the entire satisfaction of user /dep. Attending break down inspection service report duly mentioning the date of inspection signature of service engineer, Engineer -in- Charge shall be submitted for claming payment, as required in ground as ordered by Engr-in-charge.
40M&L for carrying out the descaling of the shell & Tube condensers by isolation of each condenser by providing of dummy plate for inlet & outlet connection and separation of condenser from water circulation without disturbing the operation of the AC plant, carrying out the descaling by circulation of the diluted scale removing agent organic compound type chemical of RA III / chemtex Brand at the appropriate ratio depend upon as recommended by manufacturer and the scale deposit inside copper tube by forced circulation and opening the end covers, mechanical brushing the copper tubes with nylon brushes of various size to remove complete scale, de-greasing with caustic soda solution and flushing out with fresh water, refixing all disconnected pipes lines, end covers with new rubber gasket and opening water line valves and checking of water leakages and pressure testing, apply grease to all M.S. Bolts & Nuts and put the condensers of the following capacities in operational complete all as specified and directed by Engineer - in - Charge:-
4115 TR Capacity
4225 TR Capacity
4330 TR Capacity
4439 TR Capacity
4550 TR Capacity
4660 TR Capacity Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57999741
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs / Maintenance Of Various Chiller Units Of Centralised Ac Plants Of Make Voltas In Naval Station, Bheemunipatnam
Basic Detail
Tender No 82787
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 12 Oct 2026
Submission Date 02 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 22 Lakhs
Tender Fee 500
EMD 44000
Exemption Available
Document List
82787Tender.pdf
BOQ_889865.xls
fd31dfe7-8208-4f2b-8be1-911ab88a656d.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.