Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #57999708

Tender For special Repair To Tss Office And Mt Office Bldg No T-19 And T-57 (Mt Line) At Lkg Under Ge 881 Ews

Issued by Statutory Bodies & Commissions/Committees · Poonch, Jammu and Kashmir
Tender Value
22.11 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
0 days left
EMD
44220
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Tss Office And Mt Office Bldg No T-19 And T-57 (Mt Line) At Lkg Under Ge 881 Ews

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Oct-2026 CORRIGENDUM BOQ 04-Nov-2026

BOQ

Name of Work:- SPL REPAIR TO TSS OFFICE AND MT OFFICE BLDG NO T-19 AND T-57 (MT LINE) AT LKG UNDER GE 881 EWS
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: SPL REPAIR TO TSS OFFICE AND MT OFFICE BLDG NO T-19 AND T-57 (MT LINE) AT LKG UNDER GE 881 EWS Contract No : GE/PNH-71/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2B/R Portion:-Demolition of cement concrete (unreinforced) as in ground floor and pavings n.exc 15cm thickness below or above ground level complete all as specified and directed.
3Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
4Taking down cement plaster from brick or stone walls & scrubbing down with water including raking out joints and hacking for key etc as in patches complete all as specified and directed.
5Taking down chowkhats or frames with shutters n. exc 1.5 Sqm (without taking off shutters from frame) complete all as specified and directed.
6Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed.
750 mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
8Rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
9Rendering 10mm thick on fair faces of brick or concrete wall surfaces in cement mortar 1:6 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
10Preparation of newly plastered or unplastered surface of wall and applying two coats of cement base paint in camouflage pattern over a coat of Primer complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge.
11Preparation of newly plastered or unplastered surface of wall and applying two coats of Oil Bound Distemper (any tint) over a coat of primer including 2mm thick wall care putty complete all as specified and directed
12Factory made pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fasts complete all as specified & directed.
1335mm thick 2nd class hard wood (Sal/Hollock) plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified & directed.
14Factory made steel windows/ventilators double shutter box type outer frame made of ERW tube ‘P’ section (65 x 45 x 25mm) and shutters of ERW tube ‘P’ (50 x 35 x 20mm) openable shutters side hung including pintol hinges with two Nos of MS tower bolts 150mm size on each shutter steel handle and stopper of ‘Z’ section as specified complete with sash bars dovetailed or welded ready for glass fixing and wire gauge fixing. Steel windows will be double shutter external glazed and internal wire gauged, complete all as specified, as shown in Drg No. CEPZ/TD-324/07 Sheet 1/3 to 3/3 and as directed by Engr-In-Charge. Notes : The quoted rate shall also include :- (i) Provision of one shop coat of red oxide zinc chrome primer on all exposed steel surfaces and one coat of tar coal on the ends of steel frame in contract with brick / concrete surface. (ii) 04 Nos MS steel lugs 20x5mm MS flat 20cm long over all welded to frame (iii) PCC block for embedding lugs all as directed.
15Preparation of new wooden surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer,complete all as specified & directed.
16Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide zinc chrome primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
17Plain cement Concrete 1:3:6 type-C1 (using 20mm graded crushed stone aggregate) as in copings, holdfast, plinth band, bed blocks, benching and like, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed.
18Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
19Extruded aluminium alloy handles, fabricated type, anodised of size 150 mm and fixed, complete all as specified and directed.
20250mm long aluminium alloy anodized sliding door with haps, staple (bolt type) and fixing clips of sheets, cast or extrusted sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
21Sheet glass ordinary quality, 3mm thick, glazing with rubber neoprene packing to aluminium frame in squares not exceeding 0.50 Sqm in each pane fixed in repairs, complete all as specified.
2275 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor and finished the surface even and fair, complete all as specified and directed.
23Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed in white or coloured cement mixed with pigments to match with the colour of tiles, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
24Vitrified Ceramic tiles 10 mm thick area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4,complete all as specified and as directed by Engr-in-Charge
25Description all as per item No 23 above but as in vertical surface in skirtings,dados including 10 mm thick back coat in CM 1:4, complete all as specified and as directed by Engr-in-Charge
26Dismantling of wall/ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
27False ceiling calcium silicate fissured pattern semi perforated butt edge ceiling tiles , of size 600mm x 600mm x 4mm thick having thermal conductivity K=0.15 W/mOK, having fire performance (BS-476) fixed with and including grid system hot dipped galvanised steel section, exposed surface with pre-coated capping, main tee of size 24 x 38 mm, having 0.25mm gauge at every 1200 mm centre to centre maximum and rotary stitched cross tee of size 24 x 38 mm having 0.25 mm gauge at every 600mm c/c and sub cross tee of size 24 x 38mm, having 0.25 mm gauge at 1200 mm c/c and wall angle of size 19 x 19mm, having 0.35mm gauge fixed to the periphery of the wall and suspended with hangers at every 1200 mm c/c in both directions using 4.0mm dia pre-straightened GI wire fixed with suitable cleats and fastners complete all as specified and directed..
28Taking down exsting roof tratment of any description in any condition including removing of cement plaster of concrete of any description form the roof surfaces and removing all the debris to a distance n exc 100m and roughening surfaces by sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3 kg/sqm over cleaned surfaces and providing 10mm thick cement screed in CM 1:4 mixed with liquid WPC as per instruction, finished surface even and smooth, after that cleaning the entire roof surface thoroughly to remove all loose particles, dust/dirt particles and applying one coat of bituminious primer at the rate of 0.40ltr/sqm over the plastered surfaces of roof and applying a coat of binding material hot blown bitumen of grade 85/25 heating to working temperature of 180degree celcius @ 1.2 kg/sqm then applying APP based polymeric membrane minimum weighing 3.60 kg/sqm and minimum 3mm thick reinforced with polyster non wave fabric (wt not less than 150 gm/sqm) laid with 75mm side overlap and 150mm overlap and 150mm overlap primed surfaces by forced application as per manufactures instructions and over APP membrane applying semi hot blown bitumen 85/25 grade @ 1.20 Kg/sqm blinded with dry fine sand @ 0.5Kg/sqm and finally testing the roof treatment by ponding test for 72 hrs complete all all as specified and directed. Note:- Payment shall be made after successfull ponding test and no leakage observed duly certified by EIC.
29Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified and directed.
30Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed by Engineer- in Charge.
31Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws asspecified complete all as specified and directed.
32Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
33Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, all as specified and directed.
34Walling of random rubble stone masonry, brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
35Description all as per item no. 33 above but except stone (using old serviceable stone after cleaning) complete all as specified and directed.
36Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face (granite,trap and basalt stone) and dressing of face beds and joints, complete all as specified and directed..
37Rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:6 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
3825 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor finish and finished with surface even and fair, complete all as specified and directed.
39Non skid coloured ceramic tiles 7-8 mm thick area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6,complete all as specified and as directed by Engr-in-Charge
40Glazed ceramic coloured tiles of size 300x200mm/450x350mm x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge.
41Factory made pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fasts complete all as specified & directed.
4235mm thick 2nd class hard wood (Sal/Hollock) glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified & directed.
43Extruded aluminium alloy handles, fabricated type, anodised of size 100 mm and fixed, complete all as specified and directed.
44Stainless steel wire cloth 0.36 nominal dia of wire and average width of aparture 1.40mm and fixed with tinned tacks or galvanised wire staples, complete all as specified & directed.
45Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
46Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
47100 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor,surface finished even and fair, complete all as specified and directed.
48Dismantling of timber scantling 40sqcm and over in section unframed work,as in any position, complete all as specified and directed.
49E/M PORTION:-Taking down carefully copper/ aluminium unserviceable/ perished point wiring with casing caping (light, fan, socket or power complete) including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site and making good disturbed surfaces of wall, floors, complete all as specified and directed.
50Taking down unserviceable sub main wiring including earth continuity any type/size with surface casing/caping/TW batten/PVC conduit surface or recess and making good disturbed surfaces to match with the existing finishes complete all as specified and directed.
51Dismantling and taking down unserviceable main switches, DB etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and directed.
52Point wiring with 2 x 1.5 sqmm (as phase and neutral) and 1 x 1.5 sqmm (as earth continuity conductor) multistranded copper conductor cable connected to common earth dolly,1100 volts grade , FRLS, PVC insulated and including PVC concealled PVC conduit of suitable size with accessories and PVC boards of appropriate sizes and all requisite accessories complete for the followings:-
53One light/fan point (Ceiling and Exhaust) controlled by one switch complete all as specified and directed.
54One 5 Pin switch socket combination 6 Amp on independent board complete all as specified and directed.
55One 5 Pin switch socket combination 6 Amp on same board complete all as specified and directed.
56All as per item No.59 above but with two 2.5 sqmm size cable as phase and neutral and one 1.5 sqmm size cable as earth continuity for 15 amp multipurpose socket outlet on independent board complete all as specified and directed.
57S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
58S&F in repair Switch piano flush type 16 Amp single pole one way, (ISI marked), complete all as specified and directed.
59Socket outlet multipurpose combination 2 in 1, 3 pin, 6 Amp flush type universal,complete all as specifed and directed.
60Socket outlet multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal,complete all as specifed and directed.
61S&F in repair step type fan regulator electronic flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
62Switch socket multipurpose combination 2 in 1, 5 pin, 6 and 16 Amp flush type universal,complete all as specifed and directed.
63Ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed.
64S&F in repair LED Lamp, CDL, 12 watt, B22 base all as specified and as directed.
65Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
66LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed.
67Submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 6 Sqmm (nominal area) each and one single core 6 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping, incl taking down old u/s complete all as specified and directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate. (ii) Two run of 6 Sqmm and one run of 6 Sqmm copper cable shall be measured as one length.
68Supply and fixing ceiling fans complete with blades, down rods, electronicregulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC complete and as directed by engineer-in-charge.
69S&F in Replacement of old U/S DB's with wooden board / boxes S&F distribution board , IP 43 in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN (08 Way double door) Make: Legrand or equivalent in ABB/Schneider and making good the disturbed surface all as directed by Engg-in-charge.
70S&F in repair MCB SPN 40 Amps 240V, \\"C' series complete all as specified and directed.
71S&F MCB single pole 6 to 32 Amps, 10 KA, \\"C' series complete all as specified and directed.
72Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core stranded core nominal cross section in service connections complete all as specified and directed.
73Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I including providing alternate layers of common salt and charcoal arround earth plate, connected to earth test point all as specified or indicated including excavation and connected earth work in any of soil, P.C.C 1:3:6 type C-1 as in pit, 15mm dia GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, testing on completion including dismantling unserviceable earthing complete all as specified and directed.
74S&F in repair building security light fittings, 35 watt LED,230v, AC out door type pre-wired, IP-65/66 protection, with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket complete all as directed.
75Street light bracket made out of GI tubing 40mm bore, light grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of F.I. 50 x 6mm with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete all as specified and directed.
76S&F in repair Tubes, 40 MM 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
77Socket outlet multipurpose combination 2 in 1, 3 pin, 6/16 Amp flush type universal,complete all as specifed and directed.
78S&F in repair ceiling mounting LED light fittings luminaire 600mmx600mm, 35/36 watt, 220 v, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver , holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
79Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. and getting out in any type of soil, complete all as specified and directed.
80Removing excavated material (soil) exceeding 50m and depositing where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
81Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, in any type of soil, complete all as specified and directed.
82Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sqmm 2 core stranded core nominal cross section in service connections complete all as specified and directed.
83Supply and fixing high density poly ethylene pipes (HDPE) of pressure rating 6kgf/cm2 laid in trenches for protection of cables complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57999708
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.11 Lakhs
LAST DATE 04-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Tss Office And Mt Office Bldg No T-19 And T-57 (Mt Line) At Lkg Under Ge 881 Ews
Basic Detail
Tender No GE/PNH-71/2026-27
Bidding Type Tender
Location
City Poonch
State Jammu and Kashmir
Key Dates
Publish Date 21 Oct 2026
Submission Date 04 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 22.11 Lakhs
Tender Fee 500
EMD 44220
Exemption Available
Document List
BOQ_889853.xls
ce0bd154-ae5a-4c98-a417-588c309533bd.html
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
xls

BOQ_889853.xls

html

ce0bd154-ae5a-4c98-a417-588c309533bd.html

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender