Tender For Addn/Altn Of Oh Line To Ug Cable And Connected Items For Otm & Md Accn For Sikh Regt Under Ge Dipatoli
Tender Value
43.69 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
5 days left
EMD
87380
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn/Altn Of Oh Line To Ug Cable And Connected Items For Otm & Md Accn For Sikh Regt Under Ge Dipatoli
BOQ
| Sl. No. | Item Description |
| 1 | Supply,laying,jointing and testing commissioning XLPE insulated,armoured,heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 185 sqmm 3.5 core connected with aluminium lugs connected by crimping tools complete all as specified and directed at site by Engr-in-charge.Note:- Excavation and earth work will be measured and paid separately. |
| 2 | All as per Srl items No.1 here-in-before but of size 95 sqmm x 3.5 core |
| 3 | All as per Srl items No. 1 here-in-before but of size 70 sqmm x 3.5 core |
| 4 | All as per Srl items No. 1 here-in-before but of size 50 sqmm x 3.5 core |
| 5 | All as per Srl items No. 1 here-in-before but of size 25 sqmm x 4 core |
| 6 | All as per Srl items No. 1 here-in-before but of size 16 sqmm x 4 core |
| 7 | Excavation of soft/loose soil in trenches not exc. 1.5 m wide and not exec 1.5 mtr in deep for foundation etc.or for shafts,wells,cesspits,mainholes,pierholes etc.in any type of soil for foundation and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in- Charge. |
| 8 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 9 | Supply and laying unreinforced precast cement concrete cable covers, Class LV, Type-1, with peak, size 250 mm x 150 mm x 40 mm in trenches for cable protection complete all as specified and as directed by the Engineer - in -Charge. |
| 10 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. |
| 11 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as directed. |
| 12 | Taking down/dismantling LT PCC/steel tubular poles ,studs,insulator including V clamp,cross arms , earth wire support etc and removing from site complete all as specified and directed at site by Engr-in-charge. |
| 13 | M&L in replacement Steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-31 ( 9.00 Meters long) including earth work and PCC complete including shifting of street light, junction box, cable, channels, conductor connections from old pole to new pole all as specified and directed by Engr-in-Charge. Note : Any materials replaced will be measured in individual items respectively. |
| 14 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and filling including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed at site. |
| 15 | Supply and fix in replacement of 80 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site. |
| 16 | Supply and fix in replacement of 50 mm bore GI pipe light grade fixed on pole /trenches/wall/road crossing etc complete with clamp nut bolt etc all as specified and directed at site. |
| 17 | M&L for trenchless boring 100 mm dia under road crossings/foot paths by manual / Boring machine complete all as specified and directed at site. |
| 18 | Taking down outdoor type LT Panel with by disconnecting all connections very carefully with necessary switchgear complete all as specified and directed at site by Engr-in-charge. |
| 19 | Supply and installation testing and commissioning LT Panel out door type, water and vermin proof protection of minimum size 1500mm x 1400mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories and also including removing old exisisting one complete all as specified and as directed.(a) Copper strip busbar of 500 amps rated capacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB TPN, 415 volt adjustable thermal magnetic release type with rotary handle, 400 Amps with breaking capacity 25 KA- 01 No (Incoming )(c) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 200 Amps with breaking capacity 25 KA-02Nos (outgoing)(d) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 125 Amps wirh breaking capacity 25 KA-04Nos (outgoing) (e) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 63 Amps wirh breaking capacity 25 KA-02Nos (outgoing)(f) MCB TPN 63 Amps Outgoing -01 Nos |
| 20 | Supply and installation testing and commissioning LT Panel out door type, water and vermin proof protection of minimum size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories and also including removing old exisisting one complete all as specified and as directed.(a) Copper strip busbar of 250 amps rated capacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB TPN, 415 volt adjustable thermal magnetic release type with rotary handle, 160 Amps with breaking capacity 25 KA- 01 No (Incoming )(c) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 80 Amps wirh breaking capacity 25 KA-04Nos (outgoing)(d) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 63 Amps wirh breaking capacity 25 KA-04Nos (outgoing)(e) MCB TPN 63 Amps Outgoing -01 Nos |
| 21 | Supply and installation testing and commissioning LT Panel out door type, water and vermin proof protection of minimum size 1400mm x 1000mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment supplied fitted and connected internally complete with bus bar with other accessories and also including removing old exisisting one complete all as specified and as directed.(a) Copper strip busbar of 200 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos with compatible CTs, Digital ammeter and volt meter with selector switches , set of LED type, indicating lamps R,Y,B on incoming side.(b) MCCB TPN, 415 volt adjustable thermal magnetic release type with rotary handle, 80 Amps with breaking capacity 25 KA- 01 No (Incoming )(c) MCCB TPN 415 volt adjustable thermal magnetic release type with rotary handle 63 Amps wirh breaking capacity 25 KA-06Nos (outgoing)(d) MCB TPN 63 Amps Outgoing -01 Nos |
| 22 | Supply and installation in replacement for outdoor type CPRI approved loop in loop out junction box totally enclosed double door weather and vermin proof, suitably ventilated, 440 Volts, 50 HZ,AC supply, fully compartamentalised cubical type made out of 3 mm thick CRCA sheet steel and powder coating including suitable angle iron/flat iron frame work/supports, excavation and earth work, PCC foundation etc, including 4 Nos copper bus bar of 200 Amps with indicating lamps of R,Y,B and MCCB TPN, 415 volt adjustable type, 63 Amps with breaking capacity 25 KA- 01 No at incoming side complete all as directed and specified by Engr-in-charge. Contractor will submit junction box drawing, CPRI approval certificate of manufacturer before procurement. |
| 23 | S and F in repair polycarbonate junction loop in / loop out box of internal size 230x170x105 mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole including 25 x 3 mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed. |
| 24 | Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through heavy duty PVC conduit medium grade for street light pole including connection from kiosk box to street light fittings complete all as specified and directed. Please Enable Macros to View BoQ information |
| 25 | Supply and fix 1.5 Sqmm, single core Two runs PVC insulated and unsheathed FR cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through heavy duty PVC conduit medium grade for street light pole including connection from kiosk box to street light fittings complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer