Tender For special Repair Of Bldg No Np-1 (04 X Qtr) & Np-16 (04 X Qtr) At Karam Sngh Enclave Of Asc Bn, Provn Of Addn/ Altn Of Service Wire (External Main) Bldg No P-56 & P-57, Reqmt Of Rewiring At Otm H-Block Of Engr Regt And Addn/ Altn Of Rewiring
Tender Overview
Project Description
Tender for special Repair Of Bldg No Np-1 (04 X Qtr) & Np-16 (04 X Qtr) At Karam Sngh Enclave Of Asc Bn, Provn Of Addn/ Altn Of Service Wire (External Main) Bldg No P-56 & P-57, Reqmt Of Rewiring At Otm H-Block Of Engr Regt And Addn/ Altn Of Rewiring Of Bn Quarter Guard And Aii Coy Kote In Otm Accn Under Ge (East) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of brick tiles single layer laid on roof jointed & pointed in cement mortar complete all as specified and as directed by Engineer-in-charge. |
| 2 | Demolition mud in roofs, any thickness, including plastering and leaping etc including removing rubbish upto 500 mtr from the site complete all as specified and as directed by Engineer-in-charge |
| 3 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in roof padding complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for Rendering 10 mm thick cement mortar 1:4 mixed with integral water proofing compound as per manufacturer instruction over the padding concrete while still the concrete is still green,complete all as specified and as directed by Engineer-in-charge |
| 5 | M&L for water proofing treatment to roof surface including parapet wall comprising with the following course of treatment/Specifications from bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25@ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including prepration of roof surfaces complete all as specifiedand as directed by Engineer-in-Charge.(b) One layer of APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) land on primed surface by torched application.Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside groove of parapet walls and shall be finised by a membrane flashing.Note:- (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions. (ii) A minimum overlap shall be 75 mm length wise and 100 mm width wise of polymeric membranes repectively ansd sealed all overlaps and joints as manufacturer's instructions.(iii) The whole works shall be executed by the authorised company applicator. |
| 6 | M&L for two coat of aluminium paint over APP membrane complete all as specified and as directed by Engineer-in-charge |
| 7 | Demolition of brick work or stone/ boulder masonary built in cement mortor including all quoins, arches, pillars etc, complete all as specified and directed. |
| 8 | M&L brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in c:m 1:6, complete all as specified and directed. |
| 9 | All as per srl item No 08 here-in-before but using old bricks retrieved from dismantling under ser item 7 here-in-before including cleaning and removal of mortar from old bricks etc, complete all as specified and directed. |
| 10 | M&L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in roof kerbs or mud stops, bed blocks,back filling in chowkhats, benching etc including necessary form work, complete all as specified and directed. |
| 11 | Taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 12 | M&L for Rendering 15mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 13 | M&L for Rendering 12 mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 14 | M&L for Rendering 5 mm thick cement plaster on ceiling surfaces in cement mortar 1:3 finished fair and even without using extra cement, complete all as specified and directed. |
| 15 | M&L for Cement base paint in three coats over a coat of cement wash on newly plastered surfaces of walls including preparation of surfaces, complete all as specified & directed. |
| 16 | M & L for applying two coat of Cement base paint over old surface of walls including preparation of surfaces, complete all as specified & directed. |
| 17 | M&L for preparing newly plastered surfaces of wall and applying 2 coats of distemper oil emulsion over 2mm thick wall care putty complete all as directed of any shade on walls surfaces, complete all as specified and directed. |
| 18 | M&L for complete removal of old existing treatment over wall and applying two coats of distemper oil emulsion over 2mm thick wall care putty complete all as specified and directed. |
| 19 | M & L for White wash in three coats on newly plastered surfaces of wall including preparation of surfaces, complete all as specified & directed. |
| 20 | M & L for applying two coat of white wash over old surface of walls including preparation of surfaces complete all as specified & directed. |
| 21 | M & L for complete removal of old existing treatment over Celling and applying two coats of distemper oil emulsion over 2mm thick wall care putty complete all as directed., complete all as specified and directed. |
| 22 | M & L for applying two coats of white wash on old Ceiling surface including preparation of surface complete all as specified and directed. |
| 23 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts and removing from site to store or otherwise, complete all as specified and directed. |
| 24 | All as per srl item No 23 here-in-before but size exceeding 1.5 Sqm and not exceeding 4 Sqm each, complete all as specified and directed. |
| 25 | Taking down shutters only of any description exc 1 sqm and not exc 2 sqm each including removing from site to store or otherwise, complete all as specified and directed. |
| 26 | S&F Pressed steel frames (1.25mm sheet thickness) for doors with one or more rebates including necessary fixing lugs , hinges, lock plate, etc., size of frame 125mm x 60 mm including one shop coat of red oxide, complete all as specified and directed. |
| 27 | S&F for Pressed steel frames (1.25mm sheet thickness) for doors with one or more rebates including necessary fixing lugs , hinges, lock plate, etc., size of frame 105mm x 60 mm including one shop coat of red oxide primer, complete all as specified and directed. |
| 28 | S&F 30mm thick, Flush shutters, solid core construction, with block board core, commercial type with one face is covered with deco rative face veneer with lipping/frame to match complete all as specified & directed. |
| 29 | S&F 35 mm thick, 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed. |
| 30 | S&F Aluminium powder coated (minimum thickness of powder coating 50 micron) as in frame for doors, windows, ventilators with one or more rebates including joining cleats/aluminium beading for fixing etc. complete all as specified and directed. |
| 31 | S & F Aluminium powder coated (minimum thickness of powder coating 50 micron) for shutters of doors, window and ventilator including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (fiitings shall be paid for seperately) with extruded built up standard tubular sectios/appropriate Z section and other section of approved make conforming to IS:733 and IS:1285, fixing with dash dasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc aluminium section shall be smooth, rust free, straight, mitred and joined mechanically whenever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screw all complete as per architectural drawing and the direction of Engr-in-chief. Anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (2 no.),Note:- (i) Aluminium chowkhat /frame, glass,wiremess shall be measured and paid separately. |
| 32 | M&L for Mild steel framed work of E-165 (Fe 290) as in grills/guard bars shouldered with steel window/ ventilator frames including red oxide primer coat, complete all as specified and directed. |
| 33 | S&F sheet glass, ordinary quantity,in squares exc 0.5 sqm each pane 5.5mm thick, complete all as specified and directed. |
| 34 | S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube, complete all as specified and directed. |
| 35 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC \\"C\\"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the styles & rails with suitable PVC sheet beading and jointed togeather with solvent cement, complete all as specified and directed. |
| 36 | S&F 18mm thick Celuka PVC Board of grade 1 quality, one side prelaminated plain plain and other side plain white colour fixed with screws, solvent cement/adhesive to make cupborad shutters /shelves including dismatnling of boarding, any description, fixed inany position with nails, complete all as specified and directed. |
| 37 | Dismantling timber scantling unframed work as in fillets, rails, posts, rafters, purlins,etc under 40 Sq.cm in section, complete all as specified and directed. |
| 38 | M&L in repair for Plain fillets of 2nd class hard wood, square or rectangular or triangular in section, clean sawn, secured with nails and brads area n exc 3 Sq cm, complete all as specified and directed. |
| 39 | S & F Aluminium tower bolts, 150 mm long and fixed with steel screws complete all as specified & directed. |
| 40 | S & F butt hinges, 100 mm long of mild steel, medium weight, cold rolled complete all as specified & directed. |
| 41 | S & F Aluminium handle 125mm long fixed with steel screws complete all as specified & directed. |
| 42 | S & F Sliding door bolts 150 mm of Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed. |
| 43 | S&F in repair 100mm long hasp and staple, safety type, aluminium anodised including bolt to hinge plate and fixed with screws and fixed, complete all as specified and directed. |
| 44 | S&F 150 mm Floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring complete all as specified and as directed. |
| 45 | S&F 300 mm mild steel ordinary rat tail spring including roller and roller plate, complete all as specified and directed. |
| 46 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed. |
| 47 | M&L for Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed. |
| 48 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 49 | S&F Mild steel framed work of Fe-410-0 or Fe-310-0 (Fe-290 Gde-E-165) as in doors or gate of angle or other section with gusset plates,rails, braces etc and fixing, complete all as specified and directed. |
| 50 | M&L for Preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 51 | S&F Continous (piano) hinges of mild steel bright finish or electro galvanised with flap (when open) 30mm,fixed with steel screw, complete all as specified and directed. |
| 52 | S&F Mild steel curtain rod powder coated with fixing side brackets,end cups,rings @ 10 Nos per running metre and fixed with PVC rawl plugs & steel screws as in repairs, complete all as specified and directed. |
| 53 | Demolition of un reinforced cement concrete of any description and in any position not otherwise specially provided for, complete all as specified and directed. |
| 54 | M & L Cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in bed blocks of hold fasts, coping etc including necessary form work, complete all as specified & directed. |
| 55 | M&L for Cement concrete (1:3:6) type C-2 using 50 mm graded stone aggregate as in plinth protection, 50mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints, complete all as specified and directed. |
| 56 | M&L 40 mm thick cement concrete (1:2:4) type B-1 using (20 mm graded crushed stone aggregate) as in sub base of flooring,surface finished rough to receive floor topping, complete all as specified and directed. |
| 57 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons laid bedded , dry and pointed, complete all as specified and directed. |
| 58 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level), complete all as specified and directed. |
| 59 | M & L sand filling under floors or in foundations including watering and consolidation, complete all as directed by Engineer-in-charge . |
| 60 | Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor topping, 75 mm thick, complete all as specified and directed. |
| 61 | M & L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, jointed and pointed with gray cement and pigment over sand cushioning, complete all as specified and directed. Note :- The colour of tiles Red/Yellow approve by Engr -in -charge. |
| 62 | M&L for Machine cut kota stone slab 18 to 20 mm thick as in flooring of size not less than 0.25 Square metre each, set and jointed in cement slurry over& including screed bed of 20 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and polishing, complete all as specified and directed. |
| 63 | M&L for Granite (holes for gas pipe) tiles18- 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick plaster as in back coat CM 1:4 complete including making circular gas pipe hole, moulding at corners and polishing type, complete all as specified and directed. |
| 64 | Dismantling floor hearth or wall/stone tiling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 65 | M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular),primium quality area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and incl screed bedding 15mm thick in cm(1:6), complete all as specified and directed. |
| 66 | M & L for joint less coloured Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular), primium quality area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and incl screed bedding 15mm thick in cm(1:6), complete all as specified and directed. |
| 67 | M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular), primium quality on vertical surfaces such as in skirting /dado etc area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10 mm thick rendering in cement mortar (1:4), complete all as specified and directed. |
| 68 | Glazeded ceramic coloured (colour & shade as approved) tile 350x250x6 to 7 mm/ 450x300x6to7mm thick on vertical surface such as skirting / dados set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles, complete all as specified and directed. |
| 69 | Taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation, complete all as specified and directed. |
| 70 | All as per item No 69 here-in-before but 20 mm bore tubing, complete all as specified and directed. |
| 71 | M&L for GI steel water tubing, 15mm bore medium grade galvanized with all fittings and fixed to walls and celling or laid in floor, complete all as specified and directed. |
| 72 | All as per item No 71 here-in-before but 20 mm bore tubing, complete all as specified and directed. |
| 73 | S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 74 | S&F in repair stop valves, fancy type, CP with long shank and cup ( concealed type ), screwed both ends for 15mm bore of iron pipe or for union and fixed, complete all as specified and directed. |
| 75 | S&F in repair piller taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed, complete all as specified and directed. |
| 76 | S&F in repair stop valves/angle cock,fancy type cast copper alloy,screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. |
| 77 | S & F CI in repair Gate valve, 15mm bore, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union fixed, complete all as specified and directed. |
| 78 | S&F in repair gunmetal gate valve of 20mm dia with iron wheel head screwed both ends for iron pipe, complete all as specified and directed. |
| 79 | S&F PVC waste pipe 32 mm bore suitable to waste coupling pipe attach with rubber ring joints fixed to waste coupling of sinks / WHBs, complete all as specified and directed. |
| 80 | S&F Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm, 450 mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe as in repair, complete all as specified and directed. |
| 81 | S&F in repair 125 mm chromium plated shower rose with or without swivel joints any size including fixing to steel pipe or union, complete all as specified and directed. |
| 82 | S&F 600x450mm looking mirror of selected quality mounted on 6mm thick commercial plywood and fixed to wall with plug and screws etc, complete all as specified and directed. |
| 83 | S&F Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed to walls with steel screws and wooden/rawl plugs as in repairs, complete all as specified and directed. |
| 84 | S & F corner glass shelves 300 mm radius 8 mm thick as per sample radius for bathroom, fixed on suitable support of brass chromium plated clips complete all as specified and directed. (Make: Prayag, Somany, Cera). |
| 85 | S&F Stainless steel soap dish (not less than 1mm thick) of type as directed,fixed to walls with chromium plated brass screws with wooden/rawl plugs, in repair, complete all as specified and directed. |
| 86 | S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and astes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed |
| 87 | S&F in repair 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I, complete all as specified and directed. |
| 88 | Supply & Fix in repairs Squatting pan orrissa pattern vitreous china white of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore sand cast cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints etc, complete all as specified & directed. |
| 89 | S & F Low level flushing cistern, PVC (white), 10 liters capacity, with inlet ball float valve, PVC flush pipe and necessary fixing accessories and connecting to water pipe and EWC etc and fixed in repairs, complete all as specified & directed. |
| 90 | S&F Vitreous china wash basin, white/ coloured, flat back, size 550x400mm including PTMT waste coupling fittings, 32mm bore size, waste pipe pvc 32mm bore and angle iron brackets of required size and length etc. and making good disturbed surfaces to match with the existing, complete all as specified and directed. |
| 91 | Taking down eaves gutter and rain water pipes any size or pattern including all fitting heads shoes bends swan - necks, complete all as specified and directed. |
| 92 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches, complete all as specified and directed. |
| 93 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches, complete all as specified and directed. |
| 94 | S&F 110 mm dia PVC ( rain water ) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified & directed. |
| 95 | S&F 75mm dia PVC (SWR) bends any radius, complete all as specified and directed. |
| 96 | S&F 110 mm dia PVC (SWR) bends any radius, complete all as specified and directed. |
| 97 | S&F 75mm dia Junction single (Single or double T) equal or unequal, complete all as specified and directed. |
| 98 | S&F 110 mm dia junction single 9 Single or double T) or unequal, complete all as specified and directed. |
| 99 | M&L PVC (SWR) floor trap 75 mm, plain with PVC grating including jointing with solvent cement etc., complete all as specified and directed. |
| 100 | Dismantling asbestos cement/GI (Corrugated, semi corrugated, etc) sheets in on roof coverings, complete all as specified and directed. |
| 101 | M & L prepainted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 102 | S & F rolled mild steel channnel, angle as in purline ,rafter & vertical type etc on roof cutting to dead length where required and welding to each other, complete all as specified and directed. |
| 103 | Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed. |
| 104 | Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity, complete all as specified and directed. |
| 105 | Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing, complete all as specified and directed. |
| 106 | S&F Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specified and directed for following : (a) One light/fan/bell/Bldg security light point controlled by one single pole one way switch. |
| 107 | All as per item No. 106 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board, complete all as specified and directed. |
| 108 | All as per item No. 106 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on same board, complete all as specified and directed. |
| 109 | All as per item No. 106 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC FRLS insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed. |
| 110 | All as per item No. 106 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC FRLS insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed. |
| 111 | S&F 6 amps, switch 240V, 50Hz, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 112 | S&F 6 Amps Socket 2 in 1, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 113 | S&F Switch 16 amps, single pole one way, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 114 | S&F Socket 16 Amps, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 115 | S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 116 | S&F batten holder, 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 117 | S&F LED bulb of 9/10 watts B-22 CDL 3 star 6500K, complete all as specified and directed. |
| 118 | S&F rotary stepped type electronic fan regulator compatible for BLDC ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, deluxe, white in colour, duly ISI marked, complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 119 | Fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core FR PVC Insulated & overall round sheathed flexible with PVC, colour of cores are Red, Black & Yellow/ Green is for earthing. Sheath colour is Black of cable size 23/0.0076, complete all as specified and directed. Note : Ceiling fans obtained/ taking down from item Sr No.103 as above |
| 120 | Supply and fixing LED light fitting 1 x 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 121 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection, complete all as specified and directed. |
| 122 | S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, partly immersed in wall, including of MCCB 4 pole adjustable thermal & fixed magnetic type 100 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 123 | S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 124 | S&F MCB SPN, 40A - 63Amps, 240 volts, \\"C\\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning, complete all as specified and directed. |
| 125 | S&F MCB SP, 6A-32 Amps, 240 volts, \\"B\\" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning, complete all as specified and directed. |
| 126 | M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length). |
| 127 | S&F exhaust fan heavy duty with louvers complete of sweep size 300mm, 1400 RPM,1710 CMH single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection, complete all as specified and directed. |
| 128 | Cutting holes making good the distributed surface, grouting nuts for fixing of Exhaust fans complete all as specified and directed. |
| 129 | Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to sxposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009). |
| 130 | Material & Labour for concealed point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified and directed by Engg-in-Charge. |
| 131 | Supply and fixing LED light fitting 1x16 Watt flameproof, CMRI certified recommended for gas/ vaporgroup of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed. |
| 132 | S&F XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 50 Sqmm nominal cross section, 3.5core, flat or circular, PVC FRLS insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC FRLS sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified and directed. |
| 133 | S&F XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 50 Sqmm nominal cross section, 4core, flat or circular, PVC FRLS insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC FRLS sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified and directed. |
| 134 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan, for laying of cable and getting out, complete all as specified and directed. |
| 135 | S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable, complete all as specified and directed. (Excavation and earth work measured separately, . |
| 136 | Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified and directed. |
| 137 | Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point, complete all as specified and directed. |
| 138 | S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc including taking down, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender