| Sl. No. | Item Description |
| 1 | Supplying, installation, testing and Commissioning of Full Bore Carbon Steel Flanged ends Electromagnetic Flow Meter, for Raw/ treated water with accuracy+/-0.5% and sensor of protection of IP 68 Grade for pressure rating PN 16 including sensor coil housed in SS 304 with coating suitable for buried application; Co-axial signal sensor/ transmitter & power cable. Hard Rubber Liner material. The output showing volumetric flow rate and totalized flow with other details shall be on remote mounted LCD display screen with upto 20 m length transmitter / sensor cabling with power supply 80-300 V AC/ 24 V DC etc. & its integration with PLC/RTU system as per technical specifications |
| 2 | Flow meter 80 mm |
| 3 | Flow meter 100 mm |
| 4 | Flow meter 150 mm |
| 5 | Flow meter 200 mm |
| 6 | Flow meter 250 mm |
| 7 | Flow meter 300 mm |
| 8 | Flow meter 350 mm |
| 9 | Supplying, installation, testing and Commissioning of Full Bore Carbon Steel Flanged ends Electromagnetic Flow Meter, for Raw/ treated water with accuracy+/-0.5% and sensor of protection of IP 68 Grade for pressure rating PN 25 including sensor coil housed in SS 304 with coating suitable for buried application; Co-axial signal sensor/ transmitter & power cable. Hard Rubber Liner material. The output showing volumetric flow rate and totalized flow with other details shall be on remote mounted LCD display screen with upto 20 m length transmitter / sensor cabling with power supply 80-300 V AC/ 24 V DC etc. & its integration with PLC/RTU system as per technical specifications |
| 10 | Flow meter 200 mm |
| 11 | Flow meter 250 mm |
| 12 | Flow meter 300 mm |
| 13 | Flow meter 350 mm |
| 14 | Supply, installation, testing & Commissioning of Local Control PLC system with software development of PLC Control Panel with front door opening cabinet for Pumping System, WTP, fitted with Power buses, MCBs & GPRS/GSM modem along with its integration with existing electromechanical system. All electrical fittings Shall be industrial type with modular controller PLC. Suitable 24-48 V DC power supply to power up PLC panel, including suitable switch mode power supply (SMPS) with UPS for Power back up of minimum 2 hours, 7” or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, for various pump combinations at various locations |
| 15 | Supply, installation, testing & Commissioning of Energy meters for tube wells & pumping stations including all accessories, cabling and integration with Automation system as per technical specifications. |
| 16 | Supply, installation testing & Commissioning of GSM/GPRS Transmitter (SIM Based) 25-Nodes over MODBUS RTU Isolated RS-485 Input Modbus /MQTT/TCP-IP Protocol Settable Alarm Trigger Network Failure Logging, weather Protection: IP-65 Certification : CE/FCC/CISPER & its data integration with SCADA system as per technical specifications |
| 17 | Supply, installation & commissioning of Instrument Protection Canopy: Instrumentation Canopy IP55 with 2mm thick CRCA sheet (700 mm X 700mm X 350mm) with 2 inch GI pipe support - 4 feet & Clamp arrangement for installation of GPRS modem, Flow transmitter, Solar charge controller & Batteries etc |
| 18 | Supply, installation & commissioning of Pressure Transmitters, making proper socket in pipe & two-way gauge cock in SS 316 for isolation of PT for installation of pressure transmitter including cabling and conduiting wiring etc. complete as per as per technical specifications. |
| 19 | Supply, installation, testing and commissioning of minimum 330 W mono crystalline solar panel module, charger controller with mains and solar compatibility, external batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to instruments with at least 48 Hrs back up for flow monitoring & control stations at GLRs. OHSRs and Distribution network as per technical specifications. |
| 20 | Design, Supply, installation, testing & commissioning of Loss of Head measurement skid for automatic backwashing of filter units by using Hydrostatic Pressure transmitters (0-3m) ( 2no. per filter) , digital indicator & transmitter, ball valves, equalizing valves, manometer type indicating tube with junction box and 10-meter signal cable and necessary accessories, complete as per the technical specifications for each filter unit. |
| 21 | Supply, installation, testing and commissioning of Ultrasonic Level transmitter with flow integrator & rectangular weir plate/ Parshall flume for open channel flow measurement and rate of flow measurement at filter outlet including erection hardware such as flanges, SS nut bolt, cantilever for mounting, wiring and associated civil works of complete system. As per technical specifications |
| 22 | Supply, installation, testing & commissioning of PH & Turbidity Analyzer along with sampling system, tubings and necessary accessories enclosed is IP54 CRCA panel of 1.5 mm thick sheet, including cabling and integration with PLC system as per technical specifications. |
| 23 | Supply, installation, testing & commissioning of PH & Residual Chlorine transmitter along with sampling system and necessary accessories including cabling and integration with PLC system as per technical specifications. |
| 24 | Supply, laying and installation of Analog shielded signal cable & power Cable with flexible GI conduits for integration of various instruments with PLC/RTU & GPRS modem as per technical specifications. |
| 25 | Supply, installation , testing and commissioning of non contact RADAR Level transmitter (0-10/20m) with display in WTP, Sumps, GLR , Overhead tanks & Pumping stations as per technical specifications complete. |
| 26 | Supply, erection, testing and commissioning of maintenance free earth station for Main LT Panel, RTU/PLC Panel consisting of 40 X3 mm dia with 5 m long GI strip with earth enhancing compound sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site with brass bolt at the top end with nuts & washers including masonry enclosure, CI cover with frame and interconnection along with earth pit identification MS board and as required spreading of earth enhancing chemical compound etc. complete . Scope also includes excavation in all type of soil, back filling and making the area neat etc. complete. |
| 27 | Supply, erection, testing and commissioning of Lighting arrestor and maintenance free earth station for transformer consisting of 40 X3 mm dia with 3m long Copper electrode capsule for transformer neutral & GI strip of 40 X3mm dia 5m long for Transformer body & Lighting arrestor , with earth enhancing compound sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site with brass bolt at the top end with nuts & washers including masonry enclosure, CI cover with frame and interconnection along with earth pit identification MS board and as required spreading of earth enhancing chemical compound etc. complete . Scope also includes excavation in all type of soil, back filling and making the area neat etc. complete. |
| 28 | Supplying and laying 25mm X 5mm G.I strip at 0.50 meter below ground as strip for earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc as required. (Jointing shall be done by overlapping and with 2 sets of G.I nut bolt & spring washer spaced at 50 mm) |
| 29 | Construction of Reinforcement cement concrete chamber 150x150x200cm inside with 30 cms wall thickness in Cement Concrete 1:2:4 (1cement: 2coarse sand:4 graded granitic or basaltic stone aggrt. 20mm. nominal size) including centering/shuttering and TMT steel not less than 70kg/cu.m,for sluice valves or equivalent main valves of suitable diameter, with necessary excavation, 15cms thick rubble packing and 10cms thick foundation concrete 1:3:6 ( 1 cement : 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 40 mm nominal size) and inside plastered with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and as per standard drawing (rate is inclusive of earthwork excavation, and all other materials and labour as per details above ,including the Prefabricated concrete chamber cover as directed by the Engineer in charge.For 200/250 Dia |
| 30 | Construction of Reinforcement cement concrete chamber 200x200x200cm inside with 30 cms wall thickness in Cement Concrete 1:2:4 (1cement: 2coarse sand:4 graded granitic or basaltic stone aggrt. 20mm. nominal size) including centering/shuttering and TMT steel not less than 70kg/cu.m,for sluice valves or equivalent main valves of suitable diameter, with necessary excavation, 15cms thick rubble packing and 10cms thick foundation concrete 1:3:6 ( 1 cement : 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 40 mm nominal size) and inside plastered with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and as per standard drawing (rate is inclusive of earthwork excavation, and all other materials and labour as per details above ,including the Prefabricated concrete chamber cover as directed by the Engineer in charge.For 300/350/400 Dia |
| 31 | Cutting of cast iron / ductile iron pipes by mechanical grinder working on electricity, including the cost of hire charges of mechanical grinder, diesel operated electrical generator set, suitable for supplying power for the grinder for cutting, cost of grinding blades , skilled work force, fuel.etc. required for completion of job as per the direction of Engineer- in -charge |
| 32 | Flow meter 80 mm |
| 33 | Flow meter 100 mm |
| 34 | Flow meter 150 mm |
| 35 | Flow meter 200 mm |
| 36 | Flow meter 250 mm |
| 37 | Flow meter 300 mm |
| 38 | Flow meter 350 mm |
| 39 | Supplying stacking at site and conveying hoisting, laying in position to correct line and level and linking joints of MS specials. fabricated from MS plate including cutting, bending, welding, procurement of plates, gas cutting to required size, rolling, tack welding, assembling in suitable length to form special, welding on automatic machine and forming V edge on both ends of special as required, hydraulic pressure test at factory to the required test pressure conforming to IS : 3589-1991 including freight etc. complete |
| 40 | M.S.spigot tail piece suitable for connecting M.S pipeline with C.I./D.I pipeline |
| 41 | With 25mm thick flanges |
| 42 | Supplying & installation of cast iron fittings as per IS : 1538 -1993 including sealing rubber gasket (NR) CI Compression glands and coated MS Nuts bolts.Flanged Socket Tail piece ( Flanged Adaptors) |
| 43 | 200 mm |
| 44 | 250 mm |
| 45 | 300 mm |
| 46 | 350 mm |
| 47 | Supplying & installation of cast iron fittings as per IS : 1538 -1993 including sealing rubber gasket (NR) CI Compression glands and coated MS Nuts bolts.Dismantling Joint |
| 48 | 250 mm |
| 49 | 300 mm |
| 50 | 350 mm |
| 51 | Making joints to D.I/ C.I pipes with mechanical joints by nut bolts rubber rings that are provided with the joints, for push on tight joints including the cost of work force, tools, hydraulic testing of joints, etc. complete as per the direction of the engineer in-charge.Double socket specials such as bends, collar couplings, etc. |
| 52 | 200 mm |
| 53 | 250 mm |
| 54 | 300 mm |
| 55 | 350 mm |
| 56 | Making joints to D.I/ C.I pipes with mechanical joints by nut bolts rubber rings that are provided with the joints, for push on tight joints, and including the cost of rubber ring, nut bolts, for flanged joint, including the cost of work force, tools, hydraulic testing of joints, etc. complete as per the direction of the engineer in-charge.Flanged Socket/Adaptor |
| 57 | 200 mm |
| 58 | 250 mm |
| 59 | 300 mm |
| 60 | 350 mm |
| 61 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. generally conforming to BS EN 593, cone sphere eccentric design, double flanged butterfly valve having body, disc and end cover in graded cast iron to IS:210 Gr. FG 260, synthetic rubber face ring secured on disc by a SS retaining ring with stainless steel screws, the rubber ring seating on a corresponding integral Model 60 / SS316 seat in body, stub shaft of AISI 431 riding in Teflon bearings, flanges drilled to IS:1538 Table 4 & 6. TYPE P.N. 1.0 (Class A) |
| 62 | Valve PN 10- 80 mm |
| 63 | Valve PN 10- 300 mm |
| 64 | Providing and fixing Electrical Actuator suitable for sluice valve & Butterfly valve for on/off duty for Sluice valve of electrical actuator to operate Sluice Valve. rate inclusive of necessary cables & fitting |
| 65 | Valve PN 10- 80 mm |
| 66 | Valve PN 10- 300 mm |
| 67 | A . Work Station Console Supply, installation testing of Server as Workstation with 32” LED Monitors with necessary software Processor: i7 10th gen & above; OS: Win 10 professional 64 Bit. • RAM: 16 GB; • HDD 1TB or higher. • DVD-RW drive• 32” LED colour monitors, Aspect ratio 16:9 • Dual Redundant Power supply, 100-220V AC, 50/60 Hz DC 80-300V DC. • Dot Pitch 0.294 mm. Resolution: 1280x1024 minimum. • Anti-glare & Anti-static.• Keyboard & Mouse. • Speakers for audible alarms. • 10/100/1000Mbps dual Ethernet ports.• USB Port. |
| 68 | B. Maintenance Laptop • 8 GB Main memory • 1 TB Auxiliary memory • Processor: i7 8th gen & above; OS: Win 10 professional 64 Bit • 15 inch colour monitor • Wireless Keyboard • Wireless Mouse • Serial port for connecting to consoles ports • 10/100/1000 Mbps dual Ethernet ports • USB port. • HDMI port. |
| 69 | c. Microsoft Office, Home & Business 2019 Std. |
| 70 | Router with Firewall • Shall support MPLS requirements for customer edge equipment • Shall support the OSI and TCP/IP protocols • Shall Support both IPv4 and IPv6 simultaneously.• Shall support static routes and dynamic discovery of routes like RIP, IGRP, OSPF & BGP• Shall have built-in 10/100/1000 Mbps Mbps interfaces with at least 1 fiber port for interfacing with LAN as well as communication equipment which support L2 & L3 service simultaneously. • Shall support services that can recognize, classify and prioritize network traffic, optimize routing and additionally support voice & video • Shall have data forwarding at the backplane/switch fabric and line card modules which is non-blocking and will have no performance degradation at maximum traffic load even with QoS, ACL, and Multicast enabled simultaneously on the platform. • Shall have inbuilt software firewall. • Shall support secure SNMP and RMON • Shall support unicast as well as multicast IP traffic. |
| 71 | Supply, installation, testing of 110\\" LED display video Wall with latest configurations configured as a seamless rectangular wall formed using modules in a straight or curved arrangements along with all allied accessories and integration with SCADA system |
| 72 | Development and deployment of Customized Centralized IOT Platform with 10,000 tags & upgradable in future based on the requirement including mobile application. Protocols – Unlimited Integrations – Users – minimum 20 & extendable. Other 3rd party interface necessary software & Web based access. |
| 73 | Supply, Installation, testing and commissioning Power back up system 10 KVA Low frequency 3 phase type UPS with 12 volt, 150AH SMF batteries for 4 hours backup including battery Rack. |
| 74 | Renovation of SCADA control room comprising of Site preparation work including interior civil work , raised floor ceiling ducting access doors , painting partitioning , network cabling, electrical works etc. with furniture comprising of 1 Five seater Sofa , 8 Chairs & 2 tables, 2 no. 5 star Air conditioning system for IT hardware and various work stations for ( 1000 Sq ft. room) |
| 75 | Supply of Project Manager for O&M of water supply management system of control room as per technical specifications. |
| 76 | Supply of SCADA operator for O&M of water supply management system of control room as per technical specifications. |
| 77 | Five Years Operation & Maintenance and Comprehensive Warranty for SCADA Based Water Supply system as per Price schedule after final acceptance of system. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GPRS/GSM & SIM charges for data transmission, calibration and maintenance charges at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender