Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #57994012

Tender For Special Repair To Sainik Saloon And Boundary Wall Of Jcos Mess At Nda Khadakwasla

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
22.87 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
15 days left
EMD
45740
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Sainik Saloon And Boundary Wall Of Jcos Mess At Nda Khadakwasla

BOQ

Name of Work:- SPECIAL REAPIR TO SAINIK SALOON AND BOUNDARY WALL OF JCOs MESS AT NDA KHADAKWASLA
Sl. No. Item Description
1Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for taking out/laying of pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / disintegrated soil etc complete all as specified and as directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Soft/disintegrated loose soil etc complete all as specified and as directed.
3Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and as directed.
4M & L for plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) in roof kerbs, rounded or chamfered on haunching in chajjas to prevent water seepage into brick walls, including necessory formwork (upto height of 8 mtr) rounded or chamfered on edges complete all as specified and directed.
5M&L for precast cement concrete block masonry with solid blocks 1:3:6 type C-1 (using 20 mm graded stone aggregate), of size 300mm x 100mm x 200mm and setting in cement mortar 1:4, complete all as specified and directed.
6M&L for precast cement concrete block masonry with solid blocks 1:3:6 type C-1 (using 20 mm graded stone aggregate), and setting in cement mortar 1:6, complete all as specified and directed.
7M&L cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in window cills, lintels, copings, pier caps, columns, posts, boundary pillars set in cement mortar 1:4 complete all as specified and as directed.
8M&L for Precast Reinforced Cement concrete 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) in 35 mm thick (measured solid) Jallies or louvers including all mouldings set jointed in CM 1:4 but excluding frame including demolition of existing cement concrete complete all as specified and directed.
9M & L for providing Reinforced cement concrete (1:2:4) type B-1 Nominal Mix using 20 mm graded stone aggregate as in slab supported on walls ,beams and columns in floors,roofs,landings, kitchen slabs etc complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately.)
10Supply only liquid water proofing compound complete all as specified.
11M&L Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. Complete all as specified and directed.
12M&L 20 mm thick granite (jet Black) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, counter basins and like laid over and including screed bed 15 mm thick in CM 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and complete all as specified and directed. (Note:- Granite to be used in treads shall be one piece with nosing at front and cutting two grooves alongwith nosing.)
13M&L for rough finished flat formwork to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc. 200 mm thick (horizontal or sloping) work as rough finished surfaces of concrete complete all as specified and directed.
14Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs Exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc
15M&L for rough finished flat Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work work exc 10cm but n exc 20cm Wide rough finished surface of concrete complete all as specified and directed.
16M& L for clean sawn second class hard wood in scantling exc 40 Sq cm in area or over in section to replace old and decayed timber (including piercing, scarfing etc of old and new timbers if required) and removing defective portion to store complete all as specified and directed.
17S & F Second class hard wood cover fillets, bull nosed, splayed or rounded on one edge or face, wrought, secured with fevicol, nails, cross sectional area exceeding 6 Sq. cm and not exceeding 13 Sq. Cm complete all as specified and directed.
18Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
19S&F 40 mm continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed.
20S&F 40 mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, brass polished complete all as specified or as directed.
21S&F Hasp and staple 125 mm safety type mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screw complete all as specified and as directed.
22S&F in replacement of 10mm thick bevelled edge mirror of selected quality glass circular or rectangular shape with inbuilt and hidden profile LED lightening ,white strip of any size covering edge all around glass and suitable electric connection operated by switch control and mounted on 6mm thick commercial plywood and fixed to stainless steel plugs/bracket with chromium plated brass screws and cup washers with edge mounting all around complete all as specified and directed.
23S&F MS powder coated curtain rod 20mm dia including wooden polished brackets and wooden polished end caps-02 No for each rod including 6 hooks for minimum 1 mtr length of rod complete all as specified and as directed.
24S&F CP towel rail 600 mm long of brass chromium plated with lower hanger fixed with and including chromium plated brass screws and wooden / plastic cleat complete all as specified and directed.
25S&F in repairs Aluminium (Die cast) body Door closer hydraulically regulated, designation No 2, universal type, suitable for door shutters of 701 to 850 mm in width of and of weight between 36 to 60 Kg. (extruded section) complete all as specified and directed.
26M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
27S&F aluminium powder coated three track sliding window with mosquito net two track for glass leaf sliding and one track for mesh leaf sliding outer frame weighing 0.699 Kg/m, 75x26 mm size equivalent Jindal model 20671, shutter plain of size 37.5x15mm weighing 0.366 Kg/m, Section No 20690 Jindal), with powder coating of min thickness 50 micron with one or more rebates, sliding type without sash bars, 5mm thickness double tampered clear glass , rubber packing, snap beading screws,with horizontal sliding type with stainless steel mesh, frame, powder coated aluminium grill type AL 925 or equvalent grill, cutting in suitable size and fitting with screws and suitable beedings to aluminum window frame complete etc. complete all as specified.
28S&F aluminium frame work (minimum thickness of powder coating 50 micron) for doors, sliding window three track, ventilators with one or more rebates and including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc, complete all as specified and directed.
29S&F for Aluminium powder coated door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges anodised alumnium snap beading, screws etc complete all as specified and directed.
30Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
31M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions false ceiling including sunk or raised moulding pattern approved by GE fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish including necessary supporting hanger with 4.0 mm dia GI wire and 'J' bolts washer nuts for securing frame work to Gl frame work for (605 mm x 605 mm) seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl thin layer of putty with gypsum binder, sanding the sufrace till smooth surface is obtained and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
32M&L in replacement of APP based modified pre fabricated five layer 3 mm thick and weighing not less than 3.6 Kg/Sqm water proofing membrane reinforced with polyester non woven fabric mat with 150 gm/Sqm black finished with compatible primer conforming to IS 3488 @ 0.30 Lit/ Sqm and bonding material 85/25 bitumen 1.2 Kg/Sqm before and after laying membrane laid by torch application side overlap of 75 mm and over lap of 100 mm longtitudinally, At the junction of roof and parapet wall a grove of 20mm wide and 20mm deep shall be made at the height of 100 mm and membrane shall be inserted and sealed with bituminious mastic joints/overlap shall be sealed with hot bitumen 85/25 including two coats of water proofing aluminium paint on top of APP membrane shall be applied complete all as specified and completed
33M&L for 4mm thick veneered 3 ply decorative plywood, Grade-I (with BWR resin) with decorative face veneers on both face fixed with screws to timber frame work etc complete all as specified and directed.
34M & L 18/19 mm thick exterior grade Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and as directed.
35M & L 25 mm thick Block boards, grade 2 quality, interior grade, decorative type, with decorative face veneer on both face fixed with screws to cupboard shutters and shelves complete all as specified and directed.
36M&L 100mm thick, PCC 1:3:6, type C-2 (using 20 mm graded crushed stone aggregate) finished even and smooth without using extra cement as in plinth protection/path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 including forming joints 10 mm wide and upto full depth of PCC and filled with bitumenous mastic 1:3 ( one part bitumen 85/25 grade and three part sand)to be given at every 3M interval and corners of buildings complete all as specified and directed.
37M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, paving, path etc including formwork complete all as specified and directed.
38M&L 10 mm thick Double charge premium quality coloured vitrified ceramic tiles (square / rectangular) polished, area of each tiles exc 0.42 sqm but n. Exc. 1 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
39M&L 10 mm thick Double charge premium quality coloured vitrified ceramic tiles (square / rectangular) polished, area of each tiles exc. 0.42 sqm but n.exc 1 Sqm in skirting/dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick backing in CM 1:4 complete all as specified and directed.
40Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
41M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed.
42M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
43M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth including floating coat using WPC compound complete all as specified and directed. Note:- WPC shall be measured and paid separatley.
44M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement complete all as specified and directed.
45M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface finishing the surface even and smooth without using extra cement complete all as specified and directed.

AI Tender Summary

OUR REF NO 57994012
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.87 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Sainik Saloon And Boundary Wall Of Jcos Mess At Nda Khadakwasla
Basic Detail
Tender No 8136/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 12 Oct 2026
Submission Date 02 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 22.87 Lakhs
Tender Fee 500
EMD 45740
Exemption Available
Document List
629e9f58-5437-48aa-9008-8c24d81fb5e4.html
8136.pdf
BOQ_889765.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

629e9f58-5437-48aa-9008-8c24d81fb5e4.html

pdf

8136.pdf

xls

BOQ_889765.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender