Tender For Requirement Of Different Proposed Renovation Of Infrastructural Developmental Works At The Premises Of The Adm(Mv) Bungalow, Barasat, North 24 Parganas. -- Internal Electrical Installation Works Of Inside Building Including Supply And Fixi
Tender Overview
Project Description
Tender for Requirement Of Different Proposed Renovation Of Infrastructural Developmental Works At The Premises Of The Adm(Mv) Bungalow, Barasat, North 24 Parganas. -- Internal Electrical Installation Works Of Inside Building Including Supply And Fixing Of New Plug Boards, Mcb Boxes Etc. Including New Wiring.
BOQ
| Sl. No. | Item Description |
| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [ for ceiling portion only ] and in19mm bore, 3mm thick polythene pipe [for horizontal & vertical runembedded inwall], with1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/callbell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph&N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages tooriginal finish. [ only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 2 | Average Run -- 6 Mtr. |
| 3 | Average Run -- 8 Mtr. |
| 4 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light point swith 2no. 2 way Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2no. suitable size “Ph&N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish |
| 5 | Average run 11 mtr |
| 6 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make), with1.1KV grade 1x22/0.3(1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. |
| 7 | On Board |
| 8 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. -- 19 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 9 | Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works -- 25 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 10 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. [Make- Gloster/RR Kabel/ Polycab/Finolex or Brand approved by EIC] |
| 11 | 3 x 1.5 sq. mm [ For 6A S.P, S.P.B. & Run. Mtr. ] |
| 12 | 3 x 2.5 sq. mm [ For 16A P.P, 2X16A P.P.B. & Run Mtr. ] |
| 13 | 3 x 4 sq. mm [ For Gyser & Run Mtr. ] |
| 14 | 3 x 6 sq. mm [ For SPNDB & Run Mtr. ] |
| 15 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 16 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 17 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 18 | (i) 1.5 sq mm |
| 19 | (ii) 2.5 sq mm |
| 20 | (iii) 4 sq mm |
| 21 | (iv) 6 sq mm |
| 22 | (iv) 16 sq mm |
| 23 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 24 | 1 or 2 Module (75mmX75mm) [ For Call Bell S/W Board, Gyser Pt. & Roof Top light ] |
| 25 | 4 Module (125mmX75mm) |
| 26 | 6 Module ( 200 mm X 75 mm ) [ For 2X6A S.P.B, 2X16A P.P.B & 1X6A +1X16A P.P.B. ] |
| 27 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. [ Make - Legrand Myrius/ Honeywell Wraparound MK/ Anchor ROMA Urban ] |
| 28 | 5/6 A switch |
| 29 | 3 pin 5/6 A socket outlet |
| 30 | 15/16 A switch |
| 31 | 6 pin 15/16 A socket outlet |
| 32 | Bell push |
| 33 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 34 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. [ For 1 X 6A S.P. ] |
| 35 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. [ For 1 X 16A P.P. ] |
| 36 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 37 | 12 Way, Double door |
| 38 | 16 Way, Double door |
| 39 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator). |
| 40 | 6 way (4 + 18), Double door |
| 41 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 42 | 4 way (4 + 12), Double door |
| 43 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 44 | Single pole |
| 45 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs as per GS. -- 63 A TP MCB [ Make - Legrand ] |
| 46 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 47 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required. |
| 48 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.- 100 A,30KA,FPMCCB |
| 49 | Dismantling of the existing old unusable electrical installtaion incl. electrical wiring, switch board, fittings-fixtures & other materials by Co's own tools & tackels and shifting & relocate the same at suitable place & mending good the damages by necy. plaster works to these all damaged areas as per the requirement of site situation as per the direction of EIC with 1 no. Semi- skilled and 1 no. Unskilled labour for 3 day. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender