Housing Urban and Rular Development Government Departments Closing in 8 days TDR #57993206

Tender For Requirement Of Different Proposed Renovation Of Infrastructural Developmental Works At The Premises Of The Adm(Mv) Bungalow, Barasat, North 24 Parganas. -- Internal Electrical Installation Works Of Inside Building Including Supply And Fixi

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Oct 2026
8 days left
EMD
9997
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Requirement Of Different Proposed Renovation Of Infrastructural Developmental Works At The Premises Of The Adm(Mv) Bungalow, Barasat, North 24 Parganas. -- Internal Electrical Installation Works Of Inside Building Including Supply And Fixing Of New Plug Boards, Mcb Boxes Etc. Including New Wiring.

BOQ

Name of Work:- Requirement of Different proposed Renovation of Infrastructural Developmental works at the premises of the ADM(MV) Bungalow, Barasat, North 24 Parganas. -- Internal Electrical Installation works of inside building including Supply and Fixing of new plug boards, MCB Boxes etc. including new wiring.
Sl. No. Item Description
1Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [ for ceiling portion only ] and in19mm bore, 3mm thick polythene pipe [for horizontal & vertical runembedded inwall], with1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/callbell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph&N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages tooriginal finish. [ only PVC Rigid Conduit on ceiling and remaining portion concealed]
2Average Run -- 6 Mtr.
3Average Run -- 8 Mtr.
4Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light point swith 2no. 2 way Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2no. suitable size “Ph&N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish
5Average run 11 mtr
6Distribution wiring in 1.1 KV grade 22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make), with1.1KV grade 1x22/0.3(1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.
7On Board
8Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. -- 19 mm dia 3 mm thick polythene pipe without earth continuity wire
9Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works -- 25 mm dia 3 mm thick polythene pipe without earth continuity wire
10Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. [Make- Gloster/RR Kabel/ Polycab/Finolex or Brand approved by EIC]
113 x 1.5 sq. mm [ For 6A S.P, S.P.B. & Run. Mtr. ]
123 x 2.5 sq. mm [ For 16A P.P, 2X16A P.P.B. & Run Mtr. ]
133 x 4 sq. mm [ For Gyser & Run Mtr. ]
143 x 6 sq. mm [ For SPNDB & Run Mtr. ]
15Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
164 X 16 sq. mm + 2 X 6 sq. mm earth wire
17Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
18(i) 1.5 sq mm
19(ii) 2.5 sq mm
20(iii) 4 sq mm
21(iv) 6 sq mm
22(iv) 16 sq mm
23Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
241 or 2 Module (75mmX75mm) [ For Call Bell S/W Board, Gyser Pt. & Roof Top light ]
254 Module (125mmX75mm)
266 Module ( 200 mm X 75 mm ) [ For 2X6A S.P.B, 2X16A P.P.B & 1X6A +1X16A P.P.B. ]
27Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. [ Make - Legrand Myrius/ Honeywell Wraparound MK/ Anchor ROMA Urban ]
285/6 A switch
293 pin 5/6 A socket outlet
3015/16 A switch
316 pin 15/16 A socket outlet
32Bell push
33Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
34Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. [ For 1 X 6A S.P. ]
35Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. [ For 1 X 16A P.P. ]
36Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3712 Way, Double door
3816 Way, Double door
39Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator).
406 way (4 + 18), Double door
41Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
424 way (4 + 12), Double door
43Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
44Single pole
45Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs as per GS. -- 63 A TP MCB [ Make - Legrand ]
46Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
47Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required.
48Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.- 100 A,30KA,FPMCCB
49Dismantling of the existing old unusable electrical installtaion incl. electrical wiring, switch board, fittings-fixtures & other materials by Co's own tools & tackels and shifting & relocate the same at suitable place & mending good the damages by necy. plaster works to these all damaged areas as per the requirement of site situation as per the direction of EIC with 1 no. Semi- skilled and 1 no. Unskilled labour for 3 day. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57993206
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Requirement Of Different Proposed Renovation Of Infrastructural Developmental Works At The Premises Of The Adm(Mv) Bungalow, Barasat, North 24 Parganas. -- Internal Electrical Installation Works Of Inside Building Including Supply And Fixing Of New Plug Boards, Mcb Boxes Etc. Including New Wiring.
Basic Detail
Tender No 53/T of 26-27 of AE/BESD
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 12 Oct 2026
Submission Date 27 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 9997
Exemption Not Available
Document List
2911.pdf
827fed85-1af8-4161-9c86-4187885d1dd8.html
BOQ_5181969.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

html

827fed85-1af8-4161-9c86-4187885d1dd8.html

xls

BOQ_5181969.xls

pdf

Tendernotice_1.pdf

Disclaimer