Tender For Provision Of Deficient Married Accommodation For Officers (Lt Cdrs And Above) At installation Rajali, Arakkonam
Tender Overview
Project Description
Tender for Provision Of Deficient Married Accommodation For Officers (Lt Cdrs And Above) At installation Rajali, Arakkonam
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Oct-2026 | DRAWINGS | Other | 19-Nov-2026 |
| 2 | 30-Oct-2026 | corrigendum_1 | Other | 19-Nov-2026 |
| 3 | 07-Nov-2026 | Corrigendum_3 | Date | 28-Nov-2026 |
| 4 | 02-Nov-2026 | DRAWINGS_2 | Other | 28-Nov-2026 |
| 5 | 02-Nov-2026 | corrigendum_2 | Other | 28-Nov-2026 |
| 6 | 30-Oct-2026 | DRAWINGS | Other | 28-Nov-2026 |
| 7 | 30-Oct-2026 | corrigendum_1 | Other | 28-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XVIINote: Schedule 'A' Part-I to Part-XVII are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only. |
| 2 | Lump Sum price worked out by the contractor for (BUILDINGS & STRUCTURES), as listed in SCHEDULE 'A' PART-I |
| 3 | Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II |
| 4 | Lump Sum price worked out by the contractor for 'INTERNAL WATER SUPPLY', as listed in Schedule 'A' Part-III |
| 5 | Lump Sum price worked out by the contractor for 'ROAD, PATH, HARDSTANDING AND CULVERT', as listed in Schedule 'A' Part-IV |
| 6 | Lump Sum price worked out by the contractor for 'SEWAGE DISPOSAL', as listed in Schedule 'A' Part-V |
| 7 | Lumpsum price worked out by the contractor for 'AREA DRAINAGE', as listed in Schedule 'A' Part-VI |
| 8 | Lump Sum price worked out by the contractor for 'FENCING, GATE AND COMPOUND WALL', as listed in Schedule 'A' Part-VII |
| 9 | Lump Sum price worked out by the contractor for 'RAIN WATER HARVESTING', as listed in Schedule 'A' Part-VIII |
| 10 | Lump Sum price worked out by the contractor for 'ARBORICULTURE', as listed in Schedule 'A' Part-IX |
| 11 | Lump Sum price worked out by the contractor for 'EXTERNAL WATER SUPPLY', as listed in Schedule 'A' Part-X |
| 12 | Lump Sum price worked out by the contractor for 'INTERNAL ELECTRIFICATION', as listed in Schedule 'A' Part-XI |
| 13 | Lump Sum price worked out by the contractor for 'EXTERNAL ELECTRIC SUPPLY', as listed in Schedule 'A' Part-XII |
| 14 | Lump Sum price worked out by the contractor for 'LIGHTENING PROTECTION', as listed in Schedule 'A' Part-XIII |
| 15 | Lump Sum price worked out by the contractor for 'FIRE FIGHTING SYSTEM', as listed in Schedule 'A' Part-XIV |
| 16 | Lump Sum price worked out by the contractor for 'DG SET', as listed in Schedule 'A' Part-XV |
| 17 | Lump Sum price worked out by the contractor for 'LIFT', as listed in Schedule 'A' Part-XVI |
| 18 | Lump Sum price worked out by the contractor for 'DEMOLITION/ DISMANTLING', as listed in Schedule 'A' Part-XVII |
| 19 | SCHEDULE 'A' PART-XVIII: (MISCELLANEOUS ITEMS): |
| 20 | INTERNAL WATER SUPPLY |
| 21 | S&F fancy type chromium plated bib cock long body 15mm size with wall flange, complete all as specified and directed |
| 22 | S&F fancy type brass chromium plated center hole basin mixer 15mm size for mixing Hot and Cold Water screwed down for CPVC pipe and fixed complete all as specified and directed. |
| 23 | S&F fancy type brass chromium plated wall mixer \\"L\\" bend 15mm size with wall flange with provision for overhead shower for mixing Hot and Cold Water screwed down for CPVC pipe and fixed complete all as specified and directed. |
| 24 | S&F ABS Round shower with SS Arm and Flange complete all as specified and directed . |
| 25 | S&F Liquid soap Dispenser 400ml of ABS Body fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) complete all as specified and directed. |
| 26 | S&F Tubular towel rail, Brass chromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 27 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 28 | S&F Angle stop valve of chromium plated 15mm with flange and fixed complete all as specified and directed. |
| 29 | Sewage Disposal |
| 30 | M&L for precast cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in cover slabs with frame (factory made SFRC) (for man holes etc) chullah hoods, chajjas, water trough, managers, shelves & similar articles with plain faces set in Cement mortar 1:4 complete all as specified and direcetd |
| 31 | M&L for Construction of RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 type D2 using 40 mm graded stone aggregate below foundation, Stone masonry walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 200 Users complete all as shown in drawings.(Ref Drg No. CEDD/86/TD/13B sheet 1/4 to 4/4 dated 01.05.86) |
| 32 | M&L for Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, type C2 using 40 mm graded strone aggregate walls of honey combed masonry with top ring of M-30 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats, complete of size 3.60 m Dia x 3.00 m Deep complete all as specified and directed.shown in drawings(Ref Dwg No. TD-318 (S), Sheet No. 1/1 dated 10 Mar 2006) |
| 33 | ARBORICULTURE |
| 34 | M&L for Poyta soil (garden soil) mixed with requisite quantity of pesticides and fertilizers while filling (stack measurements shall be considered for payment) complete all as directed |
| 35 | M&L for dry Gober manure mixed with requisite quantity of pesticides and filled along with the garden soil in alternate layers (stack measurements shall be considered for payment) complete all as specified and directed |
| 36 | Supply and planting dry American/ Korean grass in mud patches and watering including 2 years maintenance complete all as specified and as directed. |
| 37 | Supply and Planting of hedges like Aakalita Aspar/Duranta varigated by digging in trenches of size 300mm wide and 300mm deep and filling soil obtained from same location upto 200mm height and balance 100mm depth filled with garden soil and manure mixed in the required proportion and planting hedges of height 300mm above GL and removal of soil, debris, weeds to a distance exc 250m and n.exc 500m and watering etc complete incl 2 years maintenance complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | Supply and Planting Semi studded plants like Golden Tum/Mananta varieties as per argus/mery aglonima draft varieties by digging in trenches of size 300mm wide and 300mm deep and filling garden soil and manure mixed in the required proportion and watering etc incl 2 years maintenance complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | EXTERNAL WATER SUPPLY |
| 40 | Supply and lay 100 mm diameter ductile iron (DI) pipes, Class K-7, with spigot ends, centrifugally cast and suitable for rubber ring joints, including all specials (fittings). jointing, laying, testing, and commissioning, complete as specified and as directed by the Engineer-in-Charge. |
| 41 | M&L for brick masonry Valve chamber of size 1200mm x 12000mm x 1000mm (internal size) by providing PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation 100 mm thick brick work in CM 1:4 plastering 15mm thick in CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover complete with locking arrangement and handle including painting steel surfaces with two coats of enamel paint over a coat of red oxide primer including dismantling the existing damaged valve chamber and removing debris away from the premises etc,. complete all as specified and directed |
| 42 | Supply, Install, test and commissioning horizontal type open well submersible pump with cast iron impeller, stainless steel shaft having capable of pumping 10.97 LPS at 30 mtr head, induction motor AC 415 Volt 3 phase 50 Hz of suitable HP erected in UG sump connecting delivery pipes complete including required fittings all as specified and directed |
| 43 | Supply and lay/ lowering PVC insulated stranded copper conductor cable flat type water proof 1100 voltage with multi stranded copper conductors from starter to pump set of size 3 core, 6 sqmm suitable for submersible pump set complete all as specified and directed |
| 44 | Supply, Install, Testing and commissioning indoor type cubical panel board self supporting totally enclosed CPRI certified factory fabricated starter panel board, made out of 2 mm thick CRCA sheet steel, dust and vermin proof, hinged front opening double door shutters with neoprene rubber gasket, powder coated including danger plate, Provn of connection of GI earth strip 32x6mm size 02 Nos, ventilation louvers, bottom detachable gland plate complete cubicle panel board suitable for 3 phase 4 wire , 415 volts 50 Hz, with locking arrangement fixed to wall with all consumables in and including the following and necessary internal wiring and connections from bus bar to switch gear complete all as specified and directed :(a) MCCB, 4 pole, 25 Amps 16 KA -01 No (b) MCB, 3 pole, 16 Amps 'C' series- 02 Nos (c) Auto Star Delta starter suitable for 7.5/10 HP submersible pump along with single phase preventer-2 Nos (d) LED Phase Indication Lamp - set of three (e) Voltmeter digital Type: 0-500 Volt (f) Ammeter digital Type: 0 - 200 Amps, with CT and selector switch |
| 45 | Supply and fix cast iron NON RETURN VALVE of size 80 mm, ISI Marked, with flanged ends and suitable holes drilled including rubber gasket 3 mm thick MS bolts, nuts, and washers, necessary machining works as required at site complete all as specified and as directed |
| 46 | Internal Electrification |
| 47 | M&L for Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed cable for earth continuity green in colour, connected to earth duly complete all as specified and directed for the following:- |
| 48 | All as per Srl Item No. 40.00 here-in-before but for One light point controlled by one switch |
| 49 | All as per Srl Item No. 40.00 here-in-before but for One bell point controlled by one bell push |
| 50 | All as per Srl Item No. 40.00 here-in-before but for One Ceiling fan point controlled by one switch |
| 51 | All as per Srl Item No. 40.00 here-in-before but for One Exhaust fan point controlled by one switch |
| 52 | All as per Srl Item No. 40.00 here-in-before but for One 3 Pin socket outlet 6 amps socket on same board with other switches |
| 53 | All as per Srl Item No. 40.00 here-in-before but for One 3 Pin socket outlet 6 amps socket on independent board |
| 54 | All as per Srl Item No. 40.00 here-in-before but for One light point controlled by two number of, 2 way switches |
| 55 | All as per Srl Item No. 40.00 here-in-before but for 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board |
| 56 | Supply and fixing LED adore lamp for AC 230 Volt supply, B22 type, CDS five star, 07 watts of five star rated complete all as specified and as directed |
| 57 | Supply and fixing ceiling fan, AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, wit brushless direct current motor (BLDC) including making necessary electric connection from ceiling rose to fan connected with twin core flexible copper wire all as specified and directed. |
| 58 | S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the disturbed surfaces etc complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed. |
| 59 | S&F Exhaust fan 300 mm sweep, (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of necessary opening fixing and making good the disturbed surfaces etc complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed. |
| 60 | Supply and fixing Energy efficient LED tube light fitting with tube 1 X 36 watts 4 feet, 240V, 50 Hz surface/wall mounted, decorative LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 61 | Supply and fixing Energy efficient LED tube light fitting with tube 1X20 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 62 | S&F Energy efficient LED tube light fitting with tube 10 watts or nearest size, 240V, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 63 | Supply and fixing Energy efficient LED tube light fitting with tube 5 watts or nearest size,240V, 50hz surface mounted, mirror light decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed |
| 64 | S&F LED Security light fitting 35W outdoor type with high pressure die cast aluminium housing and heat resistant luminaire complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics of IP 65/ 66 pre wired with 1.5 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade 32 mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified and as directed |
| 65 | Supply and fixing electric Water Heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litres, BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, PVC connections etc complete all as specified and directed |
| 66 | S&F rigid non-metallic 20 mm dia PVC conduit concealed in walls/floors all as directed inclusive of all accessories like tees, bends etc complete all as specified and directed |
| 67 | S&F PVC junction box complete of 1 to 4 way of 25 mm dia all as specified and as directed |
| 68 | Supply and Fix Modular white cover plate with base frame suitable for 2 modules complete all as specified and directed |
| 69 | S&F TV Socket outlet 1 module of suitable type as required at site complete all as specified and directed |
| 70 | S&F RJ 11 Telephone Jack single with shutter 1 module of suitable type as required at site complete all as specified and directed |
| 71 | Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed . Note :Three runs of cable along with PVC conduit shall be measured as one RM |
| 72 | Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed. Note: Three runs of cable along with PVC conduit shall be measured as one RM |
| 73 | Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x6 sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed. Note: Three runs of cable along with PVC conduit shall be measured as one RM |
| 74 | Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed. Note: Five runs of cable along with PVC conduit shall be measured as one RM |
| 75 | Supply and fixing concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz, IP 54 protection, including provision for fixing MCCB TP as incomer and outgoing circuits MCB SP/DP/TP complete, fill empty way with blanking plates complete all as specified and directed. |
| 76 | Supply and fixing concealed in wall MCB DB double door type, TPN 6 way (8+18) 415V, 50Hz, IP 43 protection, including provision for fixing MCCB FP as incomer and outgoing circuits MCB SP/DP/TP complete, fill empty way with blanking plates complete all as specified and directed |
| 77 | S&F MCB TPN 415V, 50Hz, 10KA of capacity 40 Amp all as specified and directed. |
| 78 | S&F MCB SPN, 20 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed. |
| 79 | Supply, install, testing and commissioning integrity of Smart Meter three phase as per BIS 16444 with communication technology including (Cellular +RF) AC whole current, Smart Energy Meter of rating 10-60 Amps complete as per specifications, meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/ Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM / SIM of any service provider, the Smart Meter shall have a dedicated sealable slot for accommodating plug-in type, bi-directional communication module which shall integrate the respective communication technology (RF/PLC/Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WN/NAN), the Plug-In module shall be field swappable / replaceable complete all as specified and directed |
| 80 | Note :(i) Meter Specification may please be read in co-junction with PS clause. (ii) 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for cumulative energy and max demand of software. (iii) Meter should have connect / disconnect functionality operable from MDM/ billing software and prepaid features would be configured in MDM/billing end as per prevalent IS and applicable tariff plan. (iv) Meter should support communication protocol through RF (4G/5G/NB/IOT) with the software all as required at site and directed (cost of 4G/5G/NB IOT SIM, mapping vending portal charges etc. deemed to be included the unit rate quoted for meter). (v) Two way communication with DCU/HES. |
| 81 | (vi) Clock synchronisation facility with HES (Head end system). (vii) In case of RF, communication including different makes of meter shall be such that it should communicate with same DCU directly via mesh network. (viii) Guarantee of meter shall be 10 years from date of completion. (ix) The cost of meter shall include DCU / repeater cost in case of RF communication meters. (x) The OEM shall need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department. (xi) A training to handle the smart meter to MES tradesmen shall also be given by professionals. (xii) The Contractor / OEM will be held responsible for interface with the existing server of any make of MES at NCB Chennai and testing the system complete all as Specified and directed by Engineer-in-Charge |
| 82 | EXTERNAL ELECTRIC SUPPLY |
| 83 | Supply, Install, testing and commissioning 11 KV, 630 Amp Outdoor type load break switch (LBS) complete unit, extensible 1 way load break switch stand-alone floor mounted, internal copper bus bars not less than 3.15 mm thick having MS Sheet Steel enclosure suitable for IP55 as per IEC 62271-200, LBS should complete with all accessories such as HRC fuse 11 KV- 3 Nos Manual Trip Push Button, terminal boots, Provision for receiving incoming/outgoing Cables through Bottom entry, including termination kit & glands, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, Heater ON / OFF switch with filament type 200Watts space heater & thermostat, single phase switch with socket, Lamp for panel illumination with snap type door limit switch. Surge Arrester (9kV,10kA) including Control Wiring with appropriate size complete all as specified and directed with the following specifications as given :-Note : -(i) Factory inspection of load break switch and its testing shall be done by the representative of the Accepting Officer.(ii) The contractor shall produce drawing of load break switch (LBS) for according approval of GE before the ordering of material to manufacturers. (1 x LBS near Ops gate and 1 x LBS at 4 Hangar Sub Stn) |
| 84 | Supply, Installation, Testing and Commissioning of 315 KVA Compact Substation comprising of the following as per the standard specifications as per IEC 62271/2002 including all sub-clauses with base foundation as per manufacturer recommendation comprising of: |
| 85 | (A) RING MAIN UNITS:Non-extendable 11 KV SF6 insulated circuit breaker compact ring main unit (RMU) 1 way, fully arc-proof metal enclosed, free standing, manually operated type SF-6 insulated VCB 630 Amps, 350 MVA 26.3 KA with manual and mechanical mechanism & degree of protection IP 54 with the following components:(a) self-powered type IDMT based relays and related CT’s complete (b) Manual push button for Emergency Trip.(c) Ring switches and T-OFF SF6 circuit breaker with integrated earthing switches(c) Live cable indicator for ring switches (e) Padlocking facility(f) Shunt trip coil rating 230V AC(g) Numerical 20C+1EF Relay, Micro based Non Directional IDMT, Indication lamps showing VCB off/on/auto trip/Trip circuit healthy / spring charge indication(h) Digital Ammeter(j) Front access & bottom entry of HT cables. |
| 86 | (B) TRANSFORMER:Distribution Transformer step-down Level 3, 11 KV/0.433KV, Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest amendments no.4, Indoor type double copper wound suitable for 50 Hz system of capacity 160 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn-11. provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in step of 2.5%. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100 %) & Half Load (50 %) shall not be exceeded 513W & 1547W respectively and as per GRIHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete and installation of transformer shall be carried out as per IS-10028 and comprising with the following standard fittings/Technical specifications : -The transformer shall be in accordance with IS-1180 Level-2 and shall comprise of following: |
| 87 | (a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device on main transformer tank.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica gel breather(i) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(1) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Air insulated Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge.(r) Breather with silica gel with oil seal and first fill of silica gel(s) Rating diagram and terminal marking plate(t) Oil temp and winding temp indicator with maximum read pointer(u) Marselling Box |
| 88 | (C) LT PANEL:- Panel made out of 2.0mm thick CRCA comprising ACB 500 Amps 4 pole 415 V manual fixed type with thermal based release with O/L & S/C protection,m RYB indication, Ammeter, 500A/5A LT CT Cl:10, voltmeter complete.(D) ENCLOSURE:- (CRCA) powder coated with accessories like lamp, limit switches, wiring, MCB, inner connection of aluminium bus bars from transformer to LT panel, ACB etc. The degree of protection of transformer compartment of enclosure shall be minimum IP-23. Structure of the sub station shall be able to withstand the gross weight of all equipment complete. |
| 89 | Supply, lay and testing HT UG cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11 KV grade (heavy duty) suitable for earthed system with aluminium conductor of size 3 core, 95 sq mm conforming to IS:7098 (Part-II) laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and as directed. (From proposed HT panels to Transformers 3 Nos) |
| 90 | Supply, installation, testing & commissioning of 20 KVAR APFC Panel, indoor type, 6-step automatic power factor correction (5+5+4+3+2+1 KVAR), suitable for 3 phase, 415V, 50 Hz, 4 wire system, comprising MPP-H capacitors, microprocessor-based APFC relay, aluminium busbar of suitable rating, MCB/MCCB incomer, capacitor duty contactors, control MCBs, CTs, multifunction meter, LED indication lamps, push buttons, complete panel wiring, earthing, CPRI approved, factory made, fully compartmentalized, vermin proof, fabricated out of 2 mm thick CRCA sheet, powder coated, including all accessories complete in all respects. |
| 91 | Supply, Install, Testing and commissioning LT distribution board (Indoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 2mm thick CRCA steel sheet, weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items :- |
| 92 | (a) 4 Nos Aluminium Busbars of high conductivity, 3 Nos for phase (R,Y,B) rating 1200 Amps and 1No for neutral rating 1200 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set. |
| 93 | (b) ACB, 4 pole, Adj TM release, 630 Amps, 50 Hz, 415 Volts, 35KA -01 No. (Incomer) |
| 94 | (c) MCCB, 4 pole, Adj TM release, 100 A, 50 Hz, 415 Volt, 16 KA -06 Nos (Outgoing) |
| 95 | (d) Multifunction meter, three phase, digital type, with parameters like voltage, ampere, frequency, PF etc, and with suitable rated CT’s complete including selector switch for three phase etc |
| 96 | (e) Indication Lamp (R,Y,B), LED Type, With toggle switches – 1 Set of Three |
| 97 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor 3.5 core including suitable size of lugs and glands complete all as specified and directed. |
| 98 | All as per item No 78.00 above but of size 240 sq mm 3.5 core |
| 99 | All as per item No 78.00 above but of size 95 Sq mm 3.5 Core |
| 100 | All as per item No 78.00 above but of size 70 Sq mm 3.5 Core |
| 101 | All as per item No 78.00 above but of size 50 Sq mm 3.5 Core |
| 102 | All as per item No 78.00 above but of size 35 Sq mm 3.5 Core |
| 103 | All as per item No 78.00 above but of size 25 Sq mm 4 Core |
| 104 | All as per item No 78.00 above but of size 16 Sq mm 4 Core Please Enable Macros to View BoQ information |
| 105 | All as per item No 78.00 above but of size 16 Sq mm 4 Core Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender