Youth Affairs and Sports and Culture Government Departments Closing in 9 days TDR #57991364

Tender For Renovation Of Office Space For National Sports Federations (Nsfs) In Cycling Velodrome At Indira Gandhi Stadium- Phase 1, New Delhi.

Issued by Government Departments · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Nov 2026
9 days left
EMD
13.60 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Office Space For National Sports Federations (Nsfs) In Cycling Velodrome At Indira Gandhi Stadium- Phase 1, New Delhi.

BOQ

Name of Work:- Renovation of Office Space for National Sports Federations (NSFs) in Cycling Velodrome at Indira Gandhi Stadium- Phase 1, New Delhi.
Sl. No. Item Description
1Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
2Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20%
3Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
4Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
5Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
6Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby redArea of slab over 0.50 Sqm
7Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
8Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels ete. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5/ MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
9Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
10Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
11Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):Rectangular or square
12Providing and fixing bright finished brass handles with screws etc.complete:125 mm
13Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with Si, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
14Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
15Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm
16Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm
17Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
18Providing and fixing partition upto ceiling height consistingof G.I. frame and required board, including providing and fixing of frame work made of special section power pressed! roll form G.I. sheet with zinc coating of 120 gms/sgm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete.66 mm overall thickness Partition with 8 mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./ sq.cm
19Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
20Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick
21Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
22Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
23Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates efc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
24Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of sizeSize of Tile 600 x 600 mm
25Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of sizeSize of Tile 800 x 800 mm
26Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes,finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
27Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
28Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth)
2912 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
30Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
31Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
32Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
33Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
34Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge.(Final coat to be done in 1 or 2 layers without gap of time.)
35Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-chargeIn cement mortar
36Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Metres lead :Of area 3 sq. Metres and below
37Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
38Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
39Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
40Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
41Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) For fixed portion - Powder coated aluminium (minimum thickness of powder coating 50 micron)
42For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
43Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/Sqm)
44Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
45Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
46Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles.
47Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
48Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @0gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60)
49Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.50 mm average thickness
50Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.25 mm average thickness
51Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter
52Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter
53Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12 mm dia
54Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
55Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.
56Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers
57Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
58Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
59Providing and fixing aluminium sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).
60Providing and fixing 8 mm thick fibre cement board, Type-B, Category-III conforming to IS 14862:2000, reinforced with cellulose fibres and manufactured through autoclaving process (high-pressure steam cured), on existing M.S. framework in double skin configuration, fixed with approved self-drilling/self-tapping fibre cement screws, including jointing, cutting, finishing and all incidental works complete as per manufacturer's specifications and directions of Engineer-in-Charge.
61Total Cost Including GST factor of 0.973
62Total Cost Less Cost Index of 9%
63Providing and fixing HDF wooden laminated flooring 12mm thick of AC-5 HDF grade of \\"Action Tesa\\" or equivalent brand with 0.20 mm thick Polyurethane Sheet and 2mm thick PU foam as per approved colour, shade and design complete as per direction of Engineer-in-Charge.
64Providing and fixing 100mm skirting made of 12mm thick wooden laminated flooring of \\"Action Tesa\\" or equivalent and fixed with all necessary etc complete as per dirction of Engineer-in-Charge.
65Providing and fixing Stainless Steel Glass Door Handle (H-Shape) of size 32x600 of make Hardyen Cat No. HPH-141 or equivalent) i/c necessary screws etc. all complete as approved by Engineer-in-charge.
66Providing and fixing WPC Louvers wall lining of Ventura/ In Clad make 24 mm thickness of approved make colour as per architectural drawing with necessary screws/nuts & bolts/nails, complete as per direction of Engineer-in-charge.
67Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). 3mm thick plain HDHMR board of Action Tesa or equivalent make.
68Providing & fixing wallpaper of reputed brand like Gloob Decor, Ultrawalls, Elmentoo, Marshalls, The art of wallpaper, wall Decor or of such similarly reputed brand of 300 to 400 gsm approximately approved brand on existing smooth surface of wall/panelling or ceiling i/c applying of adhesive & powder, fixing on wall and matching the joints/ design pattern as per the approval of the engineer in charge complete and nothing will be paid extra for execution of the item. This job includes all leads, lifts for all floor, material & labour complete and nothing will be paid extra for execution of the item. All work is to be executed as per the design approval and direction. Surface area will be measured for payment.
69Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). 12mm thick plain HDHMR board of Action Tesa or equivalent make.
70P/F sun control film on windows of make Garware or equivalent brand of approved quality etc. complete as per direction of Engineer-in-charge.
71Providing and fixing of Zebra Blinds with Headrail of reputed make Vista (Premium Series) or equivalent & specification of under the make in India project with environment Certification of Green Guard. The system operation shall be mooth & free movement roller. The fabric shall comprise of 75% PVC ,25% polyester fabric with openness of 5% ensure adequate light & darkening with privacy ,Thickness : 0.63mm (+5%) : Weight of fabric : 465 GSM (+5%) Fire Resistance NFPA 701, BS 5867 Part-2 Type-A: Colour fasteness of light (8) grade : Hardware of ROLLER TUBE of High Strength extruded Aluminium alloy anodized 32mm OD with a minimum wall thickness of 1.00 mm duly. IDLER shall be of high strength fiberglass reinforced polyster consisting of an outside sleeve and centre shaft. Sleeve shall provide bearing surface of roller tube and rotate freely on centre shaft, The tube shall be closed from sides with end caps to give a neat look. The BALLCHAIN shall be 2mm diameter cord with 4.5mm diameter acetal balls moulded co-axially to it on 6mm pitch to form an endless ball chain.(All the MTC and warranty certificate of the company shall be provided by the contractor providing smooth, quiet and long wearing operation. Fixing BRACKETS & CLAMPS: bracket is made of mild steel and zinc plate ,clamp shall be of spring steel of thickness 0.7mm and zinc plated. BOTTOM RAIL: Extruded aluminium section in a colour matching to the fabric. The fabric shall be enclosed in the suitably created pocket along with the tube.
72Providing & fixing of GI U baffle ceiling (Burma Teak Finish) of make Armstrong, Hunter Douglas, Durlam, Hi-Steel or equivalent, consisting of panel size 50 mm (Width) X 150 mm deep minimum 0.6 mm thick GI. length up to 3000 mm. The system comprises baffles 50 mm wide. The baffle height shall be 150 mm. The baffle ceiling shall be installed at 150 mm C/C distance. Individual baffle lengths between 300 and 3000 mm can be selected. The baffle ceiling shall be supplied with the end cap matching the similar finish of baffle. Tolerances according to TAIM, DIN EN 13964 and quality controlled to ISO 9001:2008 approved by TUV. The baffle shall be electrostatically powder coated with minimum 60 micron coating thickness. Substructure for baffle system consisting of L shaped galvanized slotted carriers 1.2 mm Thick installed perpendicularly to C profiles (30 x 40 x 30 mm) of 1.2 mm thick at maximum 1200 mm centers using cross connectors. The primary profiles must be connected to one another with longitudinal splice connectors. The entire ceiling module shall be suspended with 6 mm diameter galvanized steel threaded rods from the true ceiling officially approved anchor fasteners maximum at 1200 mm centers as per the requirements of DIN EN 13964 and the statics of the system. The spacing of the grid angles is according to the requirements of DIN 18168 and DIN EN 13964 and quality controlled to ISO 9001:2008. The designs, colour finishes will be decided as per the engineer-in-charge.
73Providing and fixing fabric-faced acoustic cladding system to wall/column/partition surfaces, consisting of stretched fabric finish over an acoustic infill mounted on a rigid framework, as per drawings and manufacturer’s specifications. Framework: 48 mm GI C-Studs (0.55 mm thick, flanges 34 mm & 36 mm) fixed at spacing not exceeding 600 mm c/c, with 50 mm floor and ceiling channels (0.55 mm thick, flanges 32 mm each), and 99 mm fixing channel (0.9 mm thick with two flanges of 9.5 mm each) at horizontal joints. Framework securely anchored to wall/column/partition/floor/ceiling using galvanized screws and plugs. Base Layer: 12 mm thick BWR grade plywood fixed on outer face of framework to receive acoustic infill. Acoustic Infill: 25–50 mm thick resin-bonded glass wool / mineral wool / PET wool (density 48–64 kg/m³), NRC ≥ 0.80, fitted tightly within framework cavities. Fabric Finish: Approved make, colour, shade and texture of acoustic stretch fabric (fire-retardant, fade-resistant, acoustically transparent), stretched taut over proprietary track system or adhesive fixing method, ensuring wrinkle-free surface and neat alignment at edges and corners. Joints & Detailing: All fabric edges tucked into track channels or neatly overlapped, with provision for cut-outs for electrical/network points, switches, light fixtures, skirting, and other services as shown in drawings. The work shall be executed complete in all respects including all materials, labour, adhesives, screws, framework, fabric, infill, polishing/finishing, scaffolding, and surface protection till handover, as per approved samples and instructions of Architect/Engineer-in-charge. Performance Requirement: NRC ≥ 0.80 (lab test certificate to be submitted).
74Providing and fixing of 6mm thick annealed SGG Planilaque Evolution (premium GRIHA rated lacquered glass from Saint-Gobain, AIS Glass, MODI Glass) of approved color by Architect/ Client /Customer, fixed with SGG ULTRAFIX (compatible neutral core silicon/ double sided tape) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. Lacquered glass must be made industrially (via curtain coating process); opaque (if viewed against a support wall), coated with PU lacquer (50 micron thick); color consistency (measured by Minolta spectrophotometer CM5081); highly durable (passes PERSOZ hardness test for minimum 220 oscillatios); humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial/ 6% post consumer); compressive strenght (1000 MPa) & tensile strength (40 MPa), same as float glass;
75CURVILINEAR WORKSTATIONS 1500mm x 1500mm SINGLE SEATER.Curvilinear workstation 1500x1500x600 : Top made up of 25 mm thick pre laminated Particle Board finished with 2 mm thick PVC edging.Metal legs 50x50mm. 50-60mm Partition with double raceway and with cpu trolley and keyboard tray. Race way for wiring will be provided below the table top with provision for fixing switches. A 3 drawer metal pedestal in .8mm CRCA sheet of size 400x450x680 will be provided for each workstation.
76LINEAR WORKSTATIONS 1200mm x 600mm SINGLE SEATERLinear workstation 1200x600 : Top made up of 25 mm thick pre laminated Particle Board finished with 2 mm thick PVC edging.Metal legs 50x50mm. 50-60mm Partition with double raceway and with cpu trolley and keyboard tray. Race way for wiring will be provided below the table top with provision for fixing switches. A 3 drawer metal pedestal in .8mm CRCA sheet of size 400x450x680 will be provided for each workstation.
77CABIN TABLES L TYPE 1800mm X 750mm and Side unit.Providing , Supplying & Installing Executive table in Semi-knock down conditions with an overall size W1800mm X D750mm X H750mm. The Working top shall have the size 1800mm X 750mm made up of 25mm thick Pre-laminated particle board with 2mm thick PVC Edge bending. A full height modesty panel of 18mm thick Pre-laminated particle board with appropriate PVC edge banding is used to provide structural support for the table. The side unit for with an size 1000mm X 450mm X 625mm shall be made up of Pre-laminated particle board with top and side in 45mm thick, drawer base in 9mm & rest structure in 18mm. This unit shall have storage of 2 drawer at top and 2 hinged shutter below drawers. The handles will be in SS as per approved design. A mobile 3 Drawer Pedestal unit (2D+1F) of size 455mm X 685mm X 625mm is provided in the main table. This should be made up of Pre laminated particle board of 18mm for side, back and facia & 9mm board is used for drawer base. The drawers shall have central locking feature and use the roller and ball bearing channel to enable smooth operation. The manufacturer shall have quality and safety assurance ISO standards. The boards used will conform to the Indian standards. Design will be completely in all respect as per the image. The installation, placement, and finishing will be executed as per the directives of the Engineer-in-Charge.
78CONFERENCE TABLE 6000mm X 600mm.Supplying, Installing, Providing Conclave-02 Conference Table with an Overall Size of W6000 x D3000 x H750mm. U-shape conf table topshall be Made of 36 mm thick Prelaminated Particle Board with 2mm thick PVC edgebending pressed on edges. There shall be 2 nos Round Corner Top of radius 600mm are connected through a rectangular top of 900 x 600mm to form the U-Shape of conference table.Each rectangular tops of size 1050/1200/1350/1400/1500 x 600mm shall be provided in accordance to customer requirement and approved layout. Each top shall feature pvc wire manager for access to power supply and data cables as per seating capacity.Wire carrier raceway shall be provided below the table top for power connection ..The understructure shall consists of Gable Ends in 25mm thick prelaminated particle board and Modesty Panels in 18mm thick prelaminated particle board of approved shade, edge banded with matching 2mm thick PVC lipping.Conference Table corners shall be supported on round hollow CRCA pipe of size Dia 50 x 1.2mm, provided with PPCP cap at the bottom to avoid scratch on the floor. The product has a knock-down construction. there shall be buffers provided to avoid scratches on the floor.All Wooden Panels should use Prime Quality Board With ISI Mark. Design and Material should be as per the direction of engineer-in-charge. The product should be GreenGuard, IAQ Gold, GreenPro, GRIHA Certified.
79MEETING TABLE 3150mm X 1000mmSupplying, providing, and installing Conclave-05 Conference Table having an overall size of W3150 x D1000 x H750 mm. The worktop shall be of overall 50 mm thickness, made of pre-laminated particle board, duly edge-banded with 2 mm thick PVC lipping on all edges. The tabletop shall be designed in dual shades — with a white matching laminate board provided below the top surface to enhance aesthetics. The center portion of the table shall include a matching laminate shade panel (as per reference image) for an elegant appearance. The table shall be equipped with a flip-up box for convenient access to power and data points, and a wire carrier raceway shall be provided below the tabletop to manage cable routing neatly. The understructure shall consist of gable ends and modesty panels made from 18 mm thick pre-laminated particle board of approved shade, with matching 2 mm PVC edge banding. Gable ends shall be designed in a box structure (100–150 mm width) to enhance support and stability. The product shall have a semi knock-down construction for ease of transportation and installation. Floor buffers shall be provided at the base to prevent scratches. All wooden components shall be made from prime quality ISI-marked boards. The overall design, materials, and finish shall be as per the direction and approval of the Engineer-in-Charge.
80MEETING TABLE 2400mm X 1000mmSupplying, providing, and installing Conclave-05 Conference Table having an overall size of W2400 x D1000 x H750 mm. The worktop shall be of overall 50 mm thickness, made of pre-laminated particle board, duly edge-banded with 2 mm thick PVC lipping on all edges. The tabletop shall be designed in dual shades — with a white matching laminate board provided below the top surface to enhance aesthetics. The center portion of the table shall include a matching laminate shade panel (as per reference image) for an elegant appearance. The table shall be equipped with a flip-up box for convenient access to power and data points, and a wire carrier raceway shall be provided below the tabletop to manage cable routing neatly. The understructure shall consist of gable ends and modesty panels made from 18 mm thick pre-laminated particle board of approved shade, with matching 2 mm PVC edge banding. Gable ends shall be designed in a box structure (100–150 mm width) to enhance support and stability. The product shall have a semi knock-down construction for ease of transportation and installation. Floor buffers shall be provided at the base to prevent scratches. All wooden components shall be made from prime quality ISI-marked boards. The overall design, materials, and finish shall be as per the direction and approval of the Engineer-in-Charge.
81HIGH BACK CHAIRSSupplying, providing and installing Premium High Back Mesh Chair, ergonomically designed executive-type model, conforming to the attached image and approved by the Engineer-in-Charge. The seat assembly shall be made of 14 ±1 mm thick hot-pressed plywood, upholstered with premium fabric and moulded polyurethane foam to ensure superior comfort, resilience, and durability. The backrest shall be constructed from a high-quality injection moulded polypropylene frame with a breathable mesh tapestry, designed to follow the natural curvature of the spine and provided with an adjustable lumbar support mechanism operated through dual side knobs for customized comfort. The back design shall feature a contoured ergonomic frame with an additional polypropylene (PP) rear accent panel in a matching same/contrasting shade, enhancing both the aesthetic appeal and structural strength. The headrest shall be mesh type and enclosed with PP panels for a refined appearance and long-lasting durability. The chair shall be fitted with 1-way adjustable armrests, integrally connected with the seat structure for enhanced support and flexibility. The mechanism shall be of 360° revolving type, equipped with a synchro tilt mechanism with multi-position locking for ergonomic seating flexibility and user comfort. The chair shall also be provided with a pneumatic height adjustment system for smooth and efficient seat height movement. Seat size will be 490mm W x 480 mm D. The overall back size shall be approximately 490W x 720H mm, including the headrest.Overall dimensions of the chair will be 700W*700D*1180 mm. The pedestal shall be a five-star Nylon base, fitted with five twin-wheel castors injection moulded in black polyamide, each of 60 ±1 mm diameter, suitable for stable and smooth movement on both hard and carpeted surfaces. The finish, colour tone, and upholstery texture shall be finalized as per the approval of the Engineer-in-Charge. The complete chair shall be supplied, installed, and finished in all respects to the full satisfaction and direction of the Engineer-in-Charge.
82MID BACK CHAIRSSupplying, providing and installing Premium Mid Back Mesh Chair, ergonomically designed executive-type model, conforming to the attached image and approved by the Engineer-in-Charge. The seat assembly shall be made of 14 ±1 mm thick hot-pressed plywood, upholstered with premium fabric and moulded polyurethane foam to ensure superior comfort, resilience, and durability. The backrest shall be constructed from a high-quality injection moulded polypropylene frame with a breathable mesh tapestry, designed to follow the natural curvature of the spine and provided with an adjustable lumbar support mechanism operated through dual side knobs for customized comfort. The back design shall feature a contoured ergonomic frame with an additional polypropylene (PP) rear accent panel in a matching same/contrasting shade, enhancing both the aesthetic appeal and structural strength. The chair shall be fitted with 1-way adjustable armrests, integrally connected with the seat structure for enhanced support and flexibility.The mechanism shall be of 360° revolving type, equipped with a synchro tilt mechanism with multi-position locking for ergonomic seating flexibility and user comfort. The chair shall also be provided with a pneumatic height adjustment system for smooth and efficient seat height movement. Seat size will be 490mm W x 480 mm D. The overall back size shall be approximately 490W x 580H mm.Overall dimensions of the chair will be 700W*700D*1090mm. The pedestal shall be a five-star Nylon base, fitted with five twin-wheel castors injection moulded in black polyamide, each of 60 ±1 mm diameter, suitable for stable and smooth movement on both hard and carpeted surfaces. The finish, colour tone, and upholstery texture shall be finalized as per the approval of the Engineer-in-Charge. The complete chair shall be supplied, installed, and finished in all respects to the full satisfaction and direction of the Engineer-in-Charge.
83STORAGE / CREDENZASupply, Installation and Placement of Wooden Storage WST-15 with an overall Size :- (L)1800mm X (D)450mm X (H)750mm. The modular storage unit top shall be made from 18 mm thick pre-laminated particle board, rest panels shall be made in 18mm thick Pre-laminated particle board while back to be made of 9 mm thick pre-laminated particle board. All edges to be provided with 2 mm thick PVC lipping. The Unit features Double two door storage of width 900mm with shelf in each stoargae. Unit top and shutter should in contrast shade of rest carcass. Handles with approved design of approved design to be fixed on each door. Skirting of 50mm is provided to support the unit. All the Wooden panels should be of premium quality and hardware used to be of approved make as per the direction of engineer-in-charge.
842 SEATER SOFA Supplying and installing a customized 2-Seater Sofa of size 1395W*810Dx840H mm (as approved by the Engineer-in-Charge), having the following specifications: The understructure shall be made using seasoned natural hardwood battens along with 12 mm thick commercial plywood to ensure structural strength and durability. The frame shall be padded with high resilience polyurethane foam, having a density of 32–40 Kg/m³ in the seat and 28–32 Kg/m³ in the backrest. Cushioned armrests shall be provided, also padded with high resilience polyurethane foam for enhanced comfort. The sofa shall be supported on two stainless steel loop legs, with a height of 50–75 mm, and fitted with polypropylene (PP) buffers at the bottom to prevent floor scratches and ensure stability. The backrest and seat shall be upholstered in high-quality leatherette fabric, neatly stitched and finished as per the approval of the Engineer-in-Charge. All materials, finishes, and workmanship shall be subject to approval and conform to standard industry practices. The item shall be completed in all respects as directed by the Engineer-in-Charge.
85SIDE TABLESSupply, installation, and providing of corner Table glass top with an overall size of W600 x D600 mm. The tabletop shall be made using good quality solid wood with glass duly polished with proper surface treatment to ensure a smooth and durable finish. A glass top shall be fitted on the table, properly grooved into the edges of the top boards to ensure a secure and seamless integration .The frame structure of the table shall be made of Sheesham/teak wood for strength and longevity. The table shall feature a 4-leg structure with cross-connecting wooden support on the width side for added stability. A bottom shelf made of wooden strips at equal intervals shall be provided in the approved finish for utility and aesthetics. All materials, finishes, and workmanship shall be subject to approval and shall conform to standard industry practices. The item shall be completed in all respects as directed by the Engineer-in-Charge.
86Supplying and placing in potision of presley solid wood coffee table in dark oak finish size :- (w)1200mm x (d)600mm x (h)460mm. Table top thickness 25mm. Presley blends mid-century sleekness with quiet craftsmanship. This solid wood coffee table features gently tapered legs, a recessed apron, and softly rounded corners that create a floating effect. The dark oak finish highlights the grain beautifully, while subtle chamfers lend depth—making it a timeless piece that feels refined, grounded, and effortlessly light. A modern blend of good quality and thoughtful design, pure by durian is a label that is created to bring new-age furniture pieces that enhance your lifestyle and align with your values. Masterfully crafted from kiln-dried solid wood in danish oak finish. Tapered legs and a recessed apron create a signature mid‑century “floating” tabletop effect. Softly rounded corners and subtle chamfers add elegant depth and mid‑century charm. Buffers ensure smooth, easy mobility while protecting floors from scratches. This product is a part of the presley collection. The Seller / Company should be NABCB CERTIFIED ISO-9001:2008, ISO-9001:2015, ISO-14001:2015, OHSAS-18001:2007. OTHER CERTIFICATIONS : Green pro, Indian Design Mark, AIOTA, FSC & PEFC certified. The Bidder should also be a member of BIFMA and One or more products of the OEM should be certified as BIFMA LEVEL 1 compliant and an official link/screenshot of the product listing must be provided from www.bifma.org”
87HIGH BACKSupplying, providing and installing Premium High Back Chair: The chair shall be an ergonomically designed executive-type model, conforming to the attached image and as approved by the Engineer-in-Charge. The seat and back shall be made of 15 ±1 mm thick hot-pressed plywood, upholstered with premium leatherette and moulded polyurethane foam, ensuring superior comfort, resilience, and durability. The back shall ergonomically contoured to provide optimal posture support and long-term comfort. The foam used for both seat and back shall be of high-resilience quality, ensuring excellent shape retention and comfort during prolonged use. The chair shall be provided with fixed PP armrests,with top handrest upholstered with leatherrite over moulded PU foam for comfortable resting. The chair shall have a 360° revolving-type torsion bar single-point control mechanism allowing synchronized seat and back tilt with upright locking and tilt tension adjustment as per user weight. . The overall dimensions of the chair shall be approximately -720W*720D*1125H mm, seat size of 540W*490D*100mm Thickness , and back size of 540 W × 710 H × 100 T mm. pedestal Assembly: The pedestal shall be a five-star aluminium base fitted with 5 Nos. twin-wheel castors injection moulded in black polyamide, having a wheel diameter of 50 ± 1 mm, suitable for smooth movement on hard and carpeted surfaces. The upholstery finish and colour shall be finalized as per the approval of the Engineer-in-Charge.
88MID BACKSupplying, providing and installing Premium Mid Back Chair: The chair shall be an ergonomically designed executive-type model, conforming to the attached image and as approved by the Engineer-in-Charge. The seat and back shall be made of 15 ±1 mm thick hot-pressed plywood, upholstered with premium leatherette and moulded polyurethane foam, ensuring superior comfort, resilience, and durability. The back shall ergonomically contoured to provide optimal posture support and long-term comfort. The foam used for both seat and back shall be of high-resilience quality, ensuring excellent shape retention and comfort during prolonged use. The chair shall be provided with fixed PP armrests,with top handrest upholstered with leatherrite over moulded PU foam for comfortable resting. The chair shall have a 360° revolving-type torsion bar single-point control mechanism allowing synchronized seat and back tilt with upright locking and tilt tension adjustment as per user weight. The overall dimensions of the chair shall be approximately -720W*720D*940H mm, seat size of 520W*490D*100mm Thickness , and back size of 540 W × 590 H × 100 T mm. pedestal Assembly: The pedestal shall be a five-star aluminium base fitted with 5 Nos. twin-wheel castors injection moulded in black polyamide, having a wheel diameter of 50 ± 1 mm, suitable for smooth movement on hard and carpeted surfaces. The upholstery finish and colour shall be finalized as per the approval of the Engineer-in-Charge.
89VISITORSupplying, providing, and installing Premium Visitor Chair, ergonomically designed as an executive-type model conforming to the approved image and specifications, and as directed by the Engineer-in-Charge. The seat and back shall be made of 15 ± 1 mm thick hot-pressed plywood, upholstered with premium leatherette and moulded high-resilience polyurethane foam to ensure superior comfort, resilience, and long-term durability. The back shall be ergonomically contoured to provide optimal posture support and maintain comfort during extended sitting periods. The foam used for both seat and back shall be of high-resilience quality, ensuring excellent shape retention and consistent comfort. The chair shall be provided with fixed PP armrests, with the top handrest upholstered in leatherette over moulded PU foam for comfortable resting. The base frame shall be of cantilever type, fabricated from 25 mm diameter, 14-gauge MS round tube, duly welded and finished with durable epoxy powder coating in approved shade to provide strength, stability, and corrosion resistance. The overall dimensions of the chair shall be approximately 650 W × 670 D × 990 H mm, seat size of 520 W × 490 D × 100 T mm, and back size of 540 W × 590 H × 100 T mm. The upholstery material, finish, and colour shall be finalized as per the approval of the Engineer-in-Charge, ensuring a premium aesthetic and a professional appearance suitable for executive and visitor seating applications.
90Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
91Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
92Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
93Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Meter 652
94Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire Meter 1001
95Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire Meter
96Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as Group C
97Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
98Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
99Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm
100Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
101Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
102Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
103Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.1 run of cable
104Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.2 run of cable
105Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.3 run of cable
106Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Internet Socket
107Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
108Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm
109Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
110Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
111Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
112Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
113Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm)
114Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
115Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
116Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)
117Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
118Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
119Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
120Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
121Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
122Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
123Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
124Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
125Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
126Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
127Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
128Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push
129Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
130Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
131Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
132Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
133Supplying and fixing heavy gause GI flexible conduit of following sizes on surface/ vertical run, fixing on surface shall be done with GI saddles etc. as required and as per direction of E-in-C.20mm
134Supplying and fixing heavy gause GI flexible conduit of following sizes on surface/ vertical run, fixing on surface shall be done with GI saddles etc. as required and as per direction of E-in-C.25mm
135Supplying & laying of following size of XLPE insulated and PVC sheathed Aluminium conductor steel armoured cable of 1.1 KV grade as required.3½ X 35 sq. mm
136Supplying & laying of following size of XLPE insulated and PVC sheathed Aluminium conductor steel armoured cable of 1.1 KV grade as required.4 X 25 sq. mm.
137Supplying & laying of following size of XLPE insulated and PVC sheathed Aluminium conductor steel armoured cable of 1.1 KV grade as required.4 X 10 sq. mm.
138Supplying & laying of following size of XLPE insulated and PVC sheathed Aluminium conductor steel armoured cable of 1.1 KV grade as required.2 X 6 sq. mm.
139Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 4 sq. mm.
140Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm
141Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm.
142Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm.
143Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm.
144Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 4 sq. mm.
145Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
146Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
147Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
148Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
149Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
150Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
151Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
152Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
153Supplying, Installation, Testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 meter and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
154LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 12 -15 watt
155LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 18 watt
156LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/ HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector.5-7 watt
157LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/ HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector.8-10 watt
158LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm).36 watt
159Supply of 8ft IP20 linear suspended standalone fitting made of extruded aluminium housing with white powder coating and is should have Microstructured antiglare optical lens. Fixture should have minimum efficacy at System level (Not Chip Level) >108lumens/watt(SDCM<3) and a minimum system lumen output of 2160 (downlight) lumens/1.2mtr (±10%) and maximum system wattage of 20W/1.2mtr and Beam angle 60-65deg, sheilding angle should be greater than 65deg. Fixture should have office complaince i.e UGR<16. Luminaire should have Life of 50000hrs@L70B0 Lumen maintenance at 45deg C ambient temperature, CCT up to 4000K, CRI >90, PF >0.95, THD<5% at full load, EMC/EMI compliance and an operating Voltage Range of 150 - 270V AC & Internal Surge Protection 3KV. The fixture should comply with the parameters as per IS10322. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Including 3 core 1.5 sq.mm. Dimension-2204X85X53 mm (±2mm). Approved Model: Wipro LM65B or equivalent in LT/Regent/Phillips
160Supply of 600mm dia Pendent Mounted Ring LED. Fixture to be made of extrusion Aluminum housing in white finish with HET plastic diffuser. LED Used shall be SMD type with Minimum system Lumens 2100 @30W & efficacy 70lm/W, Life of fixture : 50000 burning Hrs. @ L70 Lumen maintenance, CCT of 4000/5700K (SDCM<=3), CRI Ra >=90, PF >0.95, THD<10% operating Voltage Range of 150-270 V AC. Minimum Internal Surge Protection 2.0KV. LED driver should have CISPR 15 / EN 55015 compliance to limit for radio disturbance characteristics. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. Approved Model: Wipro LM23OR G2 or equivalent in LT/Regent/Phillips
161Supplying, Installation testing and commissioning of 250 mm Fresh Air Fan with louvers of Plastic body, Water Resistant and Waterproof, having power consumption of 60 W suitable for single phase AC, 220-240 volts 50 Hz, supply with 3 x 1.5 Sq.mm. FR PVC insulated copper conductor, single core cable etc. complete as reqd.Make: Havells,Bajaj,Usha.
162Supply ITC fixing of 400mm wall mounted fan working on 230v, 50 Hz AC power supply, along with inbuilt regulator, swing , motor, blade, cage and connecting lead wire with 5A plug top etc. as required. Make: Havells,Bajaj,Usha.
163Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
164Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
165Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
166Supplying, installation, testing & commissioning of fault isolator complete with base as required.
167Supplying, installation, testing & commissioning of addressable manual call point complete as required.
168Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories :Pendent Sprinkler
169Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories :Upright Sprinkler
170Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000mm
171Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200mm
172Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500mm
173Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both14 HP to 22 HP
174Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)3.6 TR
175Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only2.0 TR with 5 Star BEE Rating
176Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
177Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
178Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
179Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
180Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
181Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
182Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
183SITC of Rigid PVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thickness of closed cell nitrile rubber.32 mm dia
184SITC of Rigid PVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thickness of closed cell nitrile rubber.40 mm dia
185Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs Indoor Units
186SITC of copper control cable between indoor & outdoor Unit and remote control cabling of 2 Core x 1 sqmm. in PVC conduit complete with all respect.
187Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet
188Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet
189Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required.
190Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required.
191Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc.as required.
192Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
193Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
194Supplying, Fixing, installation, testing and commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc. as required.200 mm dia.
195Supply, Installation, Testing & Commissioning of 4K IP Based Video Conference System suitable for a conference hall accommodating approx. 35 persons (17 around main table + 8 each on sides), comprising a Software based VC solution for Teams, Zoom, Webex, supporting H.323/SIP protocols, having interfaces including 1× HDMI/HDCI/USB for 1 main PTZ camera and 1 side PTZ cameras, 1× HDMI for content sharing, minimum 3× HDMI/USB for future expansion, and 2× HDMI outputs for dual display support, along with USB BYOD functionality enabling single-cable connectivity with laptops supporting Microsoft Teams/ Zoom/ Webex/ Google Meet up to 1080p30 USB pass-through mode.The system shall include Full HD 1080p PTZ Cameras (12X optical zoom, ±100° pan, +20°/-30° tilt, minimum 10 presets suitable for complete hall coverage, automatic switching with solution. Make: QSC/ Lumens/ Crestron for PTZ camera. The audio system shall be designed for full 35-person room coverage and shall include minimum 2 digital ceiling microphones, supporting ≥20 ft pickup range per mic, with mute/unmute functionality and DSP-based echo cancellation. Make: Sennhieser/ Shure/ Cisco for miscrofone. QCS/ Bose/ Shure for DSP.The system shall further include ceiling-mounted speaker system comprising minimum 4 nos ceiling speakers (8Ω, 30W each) with compatible audio amplifier/DSP unit to ensure uniform audio distribution across the entire hall without dead zones. Make: QSC/ Sonos/ Luise Martin/ Bose. CAble cubby total 3 no.s recessed inside table, each comprising 2 Nos. 6A/16A universal power sockets, 1 No. HDMI port, 1 No. USB Type-C port (data/video charging compatible), and 1 No. USB Type-A port, in table. Make: Magnum/ MTC/ Crestron With compatible AV Switch (Make: Cisco/ Juniper/ Netgear) and AV Control System with touch screen. (Make: Crestron, Kramer, Extron) All required cables, mounts, connectors and installation accessories for complete commissioning.
196Providing, supplying, installing, testing and commissioning of 98-inch Professional 4K UHD Display, 3840×2160 resolution, HDR10/Dolby Vision support, minimum 440 nits brightness, Android TV operating system, built-in Wi-Fi and Bluetooth, 24×7 operation capability, integrated speakers, HDMI, USB, LAN and RS-232C connectivity, wall mounting arrangement with heavy-duty mounting bracket, complete with all accessories, cabling, connectors, fixing hardware, power cord, commissioning and demonstration as required, complete in all respects.MAKE: Sony / LG/ Samsung.
197Providing, supplying, installing, testing and commissioning of 75-inch Professional 4K UHD Display, 3840×2160 resolution, HDR10/Dolby Vision support, minimum 440 nits brightness, Android TV operating system, built-in Wi-Fi and Bluetooth, 24×7 operation capability, integrated speakers, HDMI, USB, LAN and RS-232C connectivity, wall mounting arrangement with heavy-duty mounting bracket, complete with all accessories, cabling, connectors, fixing hardware, power cord, commissioning and demonstration as required, complete in all respects.MAKE: Sony / LG/ Samsung.
198Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Switches
199Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Sockets
200Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.old MCB
201Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the sameElectrical DBs
202Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Old Ducting
203Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Copper wires
204Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Switchboards, power points
205Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Switchboards, power points2X2 Fittings
206Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Downlight
207Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.Batten light
208Credit for old non-functional dismentalled material,on as it is and where it is basis.No extra will be paid for dismmantalling the same.MS Conduit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57991364
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 02-11-2026
Authority
Authority Name Sports Authority Of India
Work Description Tender for Renovation Of Office Space For National Sports Federations (Nsfs) In Cycling Velodrome At Indira Gandhi Stadium- Phase 1, New Delhi.
Basic Detail
Tender No 01-11028/24/2026-HO - Infra Division (I)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 12 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 13.60 Lakhs
Exemption Not Available
Document List
BOQ_977255.xls
f6963ad3-a4de-4d7d-a2ed-d57622dd6262.html
Tendernotice2.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_977255.xls

html

f6963ad3-a4de-4d7d-a2ed-d57622dd6262.html

pdf

Tendernotice2.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender