Tender For Construction Of Fountain Near Entrance Area At Fhq Ssb East Block V, R.K. Puram New Delhi.
Tender Value
9.61 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
3 days left
EMD
19231
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Fountain Near Entrance Area At Fhq Ssb East Block V, R.K. Puram New Delhi.
BOQ
| Sl. No. | Item Description |
| 1 | Prunning of big tree mannually using saftey rope, ladder, wheel and removing the branches safely without any damages of existing building and structures ( all tools and equipments arranged by contractor) complete as per direction of Engineer-in-Charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4(1 cement :4 coarse sand) |
| 8 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 10 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 12 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes |
| 14 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall, 25 mm dia nominal bore |
| 15 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 16 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion, Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 17 | Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self- healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer- in-charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 18 | Market/Annalysis Rate at SL No. 18 to 31Suupplying and Fixing MCB 8 ampere to 32 Ampere as per direction of Engineer In Charge. |
| 19 | Providing and fixing high pressure laminated (HPL) sheet 6 mm thickness on aluminium or steel frame for external work as per direction of Engineer-in-charge. |
| 20 | Providing and fixing PVC pipe 100 mm dia for drainage/rain water ISI marked as per direction of Engineer-in-charge. |
| 21 | Provding and fixing water proof LED strip light EvenGlow/ Wipro/ Havells of equivalent |
| 22 | Providing and fixing 25 mm Geyser Jet fountain Nozzle, gun metal with shine chrome as approved by Engineeer-in-charge. |
| 23 | Providing and installation LED light Model No. SWF-1X6 (IP-68 Rating Lights) RGB or warm white to highlight the fountain as approved by Engineeer-in-charge. |
| 24 | Providing and installation Control module for RGB light SWF 1X6 /RGB (up to 10 lights) as approved by Engineeer-in-charge. |
| 25 | Providing and installation submersible pump 2 HP single phase crompton greaves/kirloskar or equivalent as approved by Engineeer-in-charge. |
| 26 | Providing and installation Control panel with starter, single phase prevention, MCB, volt-meter, amp meter, TP MCBs protection circuits etc and given proper space for step down transformer for the lights as approved by Engineeer-in-charge. |
| 27 | Complete electrical wiring work of foundation (5 Nos) with wires, joints, insulation work for Pump, lights, panel and other connection complete as approved by Engineeer-in-charge. |
| 28 | Providing and fixing 10 Sqm armoured cable 2 core copper wire polycab/KEC or equaivalent as per direction of Engineer- in-Charge. |
| 29 | Providing and fixing PVC insulated 6 Sqmm, Two core copper wire ISI marked (Havells/polycab or equivalent) as approved by Engineer-in-charge. |
| 30 | Refixing the old MS angle/tube grill upt to 3.00 Sqm. including welding rebating etc.with all nut & bolt complete as approved by Engineeer-in-charge.(old grill/ frame provided by departmentally at site) |
| 31 | Providing and fixing Stainless steel letter Logo total size 60 \\"x 48\\" with decorative design including acrylic sheet at back with lighting effects including all fastners complete as approved and directed by Engineer-in-charge. |
| 32 | Modified Estimated Cost after using correction factor on DSR 2023 on account of GST @ 0.973 (272507.77 - 265150 = 7357.77) on SL. No. 01 to 17 |
| 33 | Add Cost Index @3% on SR&DR Total 265,150.00 = 7954.50 on SL No. 01 to 17 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender