Tender For Additional Alteration Of House No. 3403 Judge House Sector 24, Chandigarh
Tender Value
12.37 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
4 days left
EMD
24755
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Additional Alteration Of House No. 3403 Judge House Sector 24, Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of ceramic tiles or vitrified and plaster to making the surface clean for refixing the glazed tiles including removing of malba complete in all respect and to the entire satisfaction of the Engineer in charge. |
| 2 | Providing and laying 1st quality ceramic glazed wall tiles of size 300x450 mm conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make, in all colours, shades as approved by Engineer-in-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand). The tiles are to be fixed by provding 2 mm thick spacer. The area of spacer is to be filled by using cement based grout of approved shade. The grooves are to be filled with cemenitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material complete in all respect and to entire statisfaction of Engineer-in-Charge. |
| 3 | Providing and fixing wooden cabinet of 13½” deep and 2’-0\\" height with open able shutter at wall above 4’-9\\" height consisting of 19mm thick with commercial board (ISI marked) lipped with teak wood lipping of 19mm x 6mm on exposed edges include cost of nail, screws, auto hinges, synthetic adhesive etc. The front shutter and sides are to be furnished with 1mm thick ISI marked superior quality mica of approved shade and inner side of the cabinet with 0.8mm thick mica of approved shade fixed in position with help of wooden gutties at wall complete in al respect to the entire satisfaction of Engineer in charge. |
| 4 | Providing & fixing P.O.P. false ceiling at all heights including poroviding & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sq, (both side inclusive) as per IS 277 and consisting of angle cleat of size 25mm wide x 1.6 mm thick with flanges of 27mm and 37mm, at 1200mm clc, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers or 25 x 10 x 0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c'c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mn each having lips of 10.5mm, at 450mm cIc, shall be fixed in a direction perpendicular to G.I ntermediate channel with connecting cip made out of 2.64mm dia x 230mm long G.I wire at every junction, including perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws 230mm interval, including laying of P.O.P. ceiling of average thickness 12 to 14mm reinforced with chicken mesh with ceiling sections including the cost of making opening for light fittings/concealed lighting, sound speakers, making suspended acoustical clouds, space for Curtains/ blinds, grills, diffusers, cut outs made with frame of perimeter channels etc suitably fixed by giving required offsets, excluding the cost of painting all complete as per and direction of the Engineer in charge |
| 5 | Providing plaster of paris (minimum 2mm thick) punning over walls with after scraping old white wash / distemper from the existing surface including chipping of surface and cost of scaffolding etc. to prepare smooth and even surface complete in all respect and to the entire satisfaction of the Engineer in charge. |
| 6 | Providing and fixing 2'-0” deep cupboard /cabinet consisting of 19mm thick commercial board and 6mm thick ply on back side, 4mm thick teak ply pasted on the exposed surface and making shelves in cabinet 0.8mm mica inside canbinet . The rate further includes the cost of lipping, piano hinges, cupboard lock, screws, nails, 2 nos. fancy s.s. handles, 2 nos. magnetic catchers, fevicol and painting two coats over one priming coat and preparation of surface on board and ply surface and spirit polishing on teak ply complete in position as per entire satisfaction of Engineer-in-charge. |
| 7 | Providing and Fixing wall paper on the existing surface wall selected by the client complete in all respect to the entire satisfactor of the Engineer in charge. |
| 8 | Providing and fixing 8mm thick herring bone wooden laminated floor (Action tessa and others) class of use 31/23 having wear resistance level of AC-4 as per EN-13329 with a direct pressure laminate surface including profile, treated with aluminium side, flooring of approved colour and shade complete in all respects and to the entire satisfaction of the Engineer in charge. |
| 9 | Providing and fixing Ist quality glazed ceramic wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand). The tiles are to be fixed by provding 3 mm thick spacer. The grooves are to be filled with cemenitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material complete in all respect and to entire statisfaction of Engineer-in-Charge. Size of tile 600 x 1200 mm |
| 10 | Providing and laying antiskid full body parking floor tiles of size 600 x 600 mm (thickness to be specified by the manufacturer is 16mm) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shape of any size as approved by Engineer-in-charge, over 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand). The tiles are to be fixed with 2 mm grove using spacers. The grove are to be filled with cementitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material complete in all respect and to entire statisfaction of Engineer in Charge. |
| 11 | Steel work in built up frame made of / M.S. flat / M.S. pipe / M.S. angles of various sections including cutting, hoisting fixing in position and applying a priming coat of approved steel primer and two coats of snthetic enmael paint, welded and bolted including special shaped washers etc.. The work is required for making security wall jaffery/ ladder/grills/ frame work for shed or sunshade / other mis work.The steel work is to be provided at the site of the building complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 12 | Providing and fixing main entry gate 5'-11\\" high (paint finish) consisting of shesham wood battens of size 5'-11\\" x 6\\" x 3/4\\" vertically, including making grooves for interlocking, with the help of M.S. nuts and bolts including paintng two coats of synthetic enamel paint over one coat of wooden primer, on the existing M.S. frame completely fixed in position in all respect to the entire satisfaction of Engineer-in-charge. |
| 13 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 14 | Providing and fixing 60 mm thick high density rubber moulded precast cement concrete paver block grey/ colored/ polished/ designer (manufactured by vibro hydraulic pressure process) consisting of design mix of cement, sand and fine aggregate having designation M35 ISI marked including the cost of good quality color and hardening agents. The paver should be compiled with tensile strength and breaking load as per BIS 6717-1993 and shall be tested against resistance to bear as per IS 1237-1980 (specification for cement concrete floor tiles). The paver should be laid over layer of 25 mm average thick screened coarse sand to the required slope and filling the joints with fine sand complete in all respects and to the entire satisfaction of Engineer in charge. |
| 15 | Providing and laying double charged vitrified floor tiles of size 600 x 1200 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade. The tiles are to be fixed with 3mm grove using spacers. The tiles are to be laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm The grove are to be filled with cementitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material. |
| 16 | Providing and laying double charged vitrified floor tiles of size 600 x 1200 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade. The tiles are to be fixed with 3mm grove using spacers. The tiles are to be laid on 12 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm The grove are to be filled with cementitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material. |
| 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender